0% found this document useful (0 votes)
205 views3 pages

5 & 10 KV DC Insulation Resistance Testers: MIT515, MIT525 and MIT1025

This document describes three insulation resistance testers - the MIT515, MIT525, and MIT1025. These testers can measure up to 10 teraohms (MIT515/525) or 20 teraohms (MIT1025). They feature timed insulation resistance tests, battery operation with a dead battery when connected to power, rapid battery charging, and data logging/download capabilities. The MIT525/1025 models add additional diagnostic test functions and an advanced memory with time/date stamping. The testers are used to test insulation on electrical equipment by performing insulation resistance tests.

Uploaded by

triyan saefudin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
205 views3 pages

5 & 10 KV DC Insulation Resistance Testers: MIT515, MIT525 and MIT1025

This document describes three insulation resistance testers - the MIT515, MIT525, and MIT1025. These testers can measure up to 10 teraohms (MIT515/525) or 20 teraohms (MIT1025). They feature timed insulation resistance tests, battery operation with a dead battery when connected to power, rapid battery charging, and data logging/download capabilities. The MIT525/1025 models add additional diagnostic test functions and an advanced memory with time/date stamping. The testers are used to test insulation on electrical equipment by performing insulation resistance tests.

Uploaded by

triyan saefudin
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

MIT515, MIT525 and MIT1025

5 & 10 kV DC Insulation Resistance Testers

MIT515, MIT525 and MIT1025


5 & 10 kV DC Insulation Resistance Testers
■■ Measures up to 10 TΩ or 20 TΩ (MIT1025)
■■ PI, DAR, DD, SV and ramp test
■■ Improved productivity – operate from line
power/mains if battery dead
■■ Li ion battery - extended capacity, rapid
charge
■■ Advanced memory with time/date stamp
■■ CATIV 600 V safety rating

DESCRIPTION FEATURES AND BENEFITS


The new range of insulation resistance testers (IRTs) are ■ 10 TΩ (5 kV) / 20 TΩ (10 kV) max. insulation resistance
smaller and lighter than previous models yet offer advanced
■ Timed IR plus PI and DAR diagnostic tests
features and rapid charge capability. The range consists of
three models; an entry level 5 kV and two fully featured units, ■ Operate with dead battery when on line power/mains
one 5 kV the other 10 kV. Resistance measurement up to
■ Rapid charge Li-ion battery – up to 6 hrs continuous testing
10 TΩ for the 5 kV models and 20 TΩ for the 10 kV model.
(5 kV)
A key productivity feature is the ability to take measurements
■ Dedicated voltmeter function (30 V to 660 V)
when connected to line power/mains with a dead battery.
Intelligent battery charging ensures the optimum charge rate ■ CATIV 600 V safety rating
as a function of battery level, resulting in minimum charge
■ Large LCD display with automatic backlight
times.
■ Noise filter – rejects up to 3 mA noise
The rugged case provides ultimate protection for a portable
instrument and a clip-on lead pouch ensures that leads ■ High altitude operation up to 3000 m
remain with the instrument at all times. The case lid is
removable for improved terminal access. IP rating is IP65 with
the case closed preventing water/dust ingress. High reliability MIT525/1025 ADDITIONAL FEATURES
and safety are built in; all models are safety rated to CATIV ■ Dielectric Discharge (DD), Step Voltage (SV) and ramp test
600 V and are double insulated. functions
Five preset voltage ranges are provided in insulation test ■ Advanced memory with time/date stamp, on screen recall
mode, plus a user settable lock voltage range. Preconfigured
■ Real time clock
diagnostic tests include Polarisation Index (PI), Dielectric
Absorption Ratio (DAR), dielectric discharge (DD), Stepped ■ Download of memory via isolated USB (type B) interface
Voltage (SV) and ramp test. (USB cable to PC)
Simplicity of operation is achieved with two rotary switches ■ PowerDB Lite asset management software
and the large backlight display enables multiple results to be
displayed simultaneously. APPLICATION
Advanced memory storage includes time/date stamping of The Insulation Resistance (IR) test is a qualitative test that
results, logging of data and recall of results to screen. A fully indicates the effectiveness of a product’s electrical insulation.
isolated USB device interface (type B) is used for safe transfer Applications include cables, transformers, motors/generators,
of data to Megger’s PowerDB / Pro, Advanced and Lite asset circuit breakers and bushings. The IR test is ideal for measuring
management software. and recording long term stability of insulation over time, a
process known as trending. IR tests are temperature dependent
and require adjustment to a reference temperature. Storage
models offer a temperature recording option.
MIT515, MIT525 and MIT1025
5 & 10 kV DC Insulation Resistance Testers
ELECTRICAL SPECIFICATIONS
Capacitance range 10 nF to 25 μF (dependant on
Voltage input range: 85-265 V rms, 50/60 Hz, 60 VA
(above 500 V): measurement voltage)

Battery: 11.1 V, 5.2 A hour, meets IEC


Capacitance accuracy (23 °C): ±10% ±5 nF
62133:2003
Voltage output accuracy +4%, -0%, ±10 V nominal test voltage
Battery life
(0 °C to 30 °C): at 1 GΩ
MIT515, MIT525: Typical capacity 6 hours continuous

at 5 kV with a 100 MΩ load
Current measurement range: 0.01 nA to 6 mA

MIT1025: Typical capacity 4.5 hours


Current measurement
continuous at 10 kV with a 100 MΩ
accuracy (23 °C): ±5% ±0.2 nA at all voltages
load
Interference (noise) rejection:
Battery charge time: 2.5 hours from deep discharge,
MIT515, MIT525 1 mA per 250 V up to a maximum of
2 hours normal discharge
3 mA
30 min. quick charge: 1 hour operation at 5 kV, 100 MΩ
MIT1025 1 mA per 600 V up a maximum of
3 mA
Test voltages
MIT515, MIT525: 250 V, 500 V, 1000 V, 2500 V,
Voltmeter range: 30 V to 660 V ac or dc, 50/60 Hz
5000 V
Voltmeter accuracy: ±3%, ±3 V
MIT1025: 500 V, 1000 V, 2500 V, 5000 V,
10000 V
Timer range: Up to 99 minutes, 15 second
minimum setting
User defined test voltage:
MIT515, MIT525 100 V to 1 kV in 10 V steps,
Memory capacity: 5½ hours continuous logging every 5 s.
1 kV to 5 kV in 25 V steps,
or 33 logged PI tests
or 350 logged IR tests
MIT1025 5 kV to 10 kV in 25 V steps
Test regimes:
Accuracy (23 °C):
MIT515 IR, IR(t), DAR, PI
MIT515, MIT525 ±5% to 1 TΩ, ±20% to 10 TΩ
MIT525, MIT1025 IR, IR(t), DAR, PI, SV, DD, ramp test

MIT1025 ±5% to 2 TΩ, ±20% to 20 TΩ


Interface: USB type B (device)

Guard : 2% error guarding 500 kΩ leakage


Real time output: USB, 1 reading/second (voltage,
with 100 MΩ load
current and resistance)

Display range analogue: 100 kΩ to 10 TΩ


ENVIROMENTAL CONDITIONS
Altitude: 3000 m, CAT rating maintained
Display range digital:
>2000 m*
MIT515, MIT525 10 kΩ to 10 TΩ
* Test leads connected

MIT1025 10 kΩ to 20 TΩ
Operating temperature -20 °C to 50 °C

Short circuit current: 3 mA nominal, max. power on all


Storage temperature: -25 °C to 65 °C
loads outperforming many 5 mA
testers
Humidity: 90% RH non-condensing at 40 °C

Insulation alarm: 10 kΩ to 1 TΩ
Ingress protection: IP65 (lid closed), IP40 (lid open)

Capacitor charge:
GENERAL SPECIFICATION
MIT515, MIT525 <3 s/μF at 3 mA to 5 kV
Safety: Meets the requirements of
IEC 61010-1, CATIV 600 V
MIT1025 <5 s/μF at 3 mA to 10 kV
EMC: Meets the requirements of
Capacitor discharge:
IEC61326-1
MIT515, MIT525 <250 ms/μF to discharge from
5000 V to 50 V
Dimensions: L 315 mm x W 285 mm x H 181 mm
Weight: 4.5 kg
MIT1025 <500 ms/μF to discharge from
10000 V to 50 V
MIT515, MIT525 and MIT1025
5 & 10 kV DC Insulation Resistance Testers

ORDERING INFORMATION
Item (Qty) Cat. No. Item (Qty) Cat. No.
MIT515-UK 1001-935 Optional Accessories
MIT515-US 1001-936 HV test lead sets
MIT515-EU 1001-937 3 m leadset x 3, medium insulated clips 1002-531
MIT515-AU 1001-938 10 m leadset x 3, medium insulated clips 1002-532
MIT525-UK 1001-939 15 m leadset x 3, medium insulated clips 1002-533
MIT525-US 1001-940 3 m leadset x 3, large insulated clips 1002-534
MIT525-EU 1001-941 10 m leadset x 3, large insulated clips 1002-535
MIT525-AU 1001-942 15 m leadset x 3, large insulated clips 1002-536
MIT1025-UK 1001-943 3 m leadset x 3, bare clips 8101-181
MIT1025-US 1001-944 8 m leadset x 3, bare clips 8101-182
MIT1025-EU 1001-945 15 m leadset x 3, bare clips 8101-183
MIT1025-AU 1001-946 Screened HV test lead sets
3 m, 5 kV screened un-insulated small clips 6220-835
Included Accessories 15 m, 5 kV screened un-insulated small clips 6311-080
User guide CD 3 m, 10 kV screened un-insulated small clips 6220-834
Power lead 10 m, 10 kV screened un-insulated small clips 6220-861
3 m leadset x 3, medium insulated clips 1002-531 15 m, 10 kV screened un-insulated small clips 6220-833
3 m leadset x 3, large insulated clips (MIT1025 only) 1002-534
Included Accessories (MIT525, MIT1025) Other
USB cable 25970-041 CB101, 5 kV Calibration Box 6311-077
PowerDB Lite software Calibration Certificate - CB101 1000-113
UKAS calibration Certificate CB101 1000-047

UK UNITED STATES OTHER TECHNICAL SALES OFFICES CERTIFICATION ISO


Archcliffe Road Dover 4271 Bronze Way Valley Forge USA, College Station USA, Registered to ISO 9001:2008 Cert. no. Q 09250
CT17 9EN England Dallas TX 75237-1019 USA Sydney AUSTRALIA, Täby SWEDEN, Ontario Registered to ISO 14001-2004 Cert. no. EMS 61597
T +44 (0) 1304 502101 T 800 723 2861 (USA only) CANADA, Trappes FRANCE, Oberursel
F +44 (0) 1304 207342 T +1 214 333 3201 GERMANY, Aargau SWITZERLAND, Dubai MIT515_525_1025_DS_en_V01
[email protected] F +1 214 331 7399 UEA, Mumbai INDIA, Durban SOUTH AFRICA, www.megger.com
[email protected] Chonburi THAILAND Megger is a registered trademark