Ordering number : EN4549A
Thick Film Hybrid IC
[Link] STK4026 II
AF Power Amplifier (Split Power Supply)
(25 W min, THD = 0.4 %)
Features • The pulse noises associated with turning the power on
and off have been reduced by the adoption of fixed
• Compact packaging supports slimmer set designs
current circuits
• Series designed for 20 up to 200 W and pin-
• Supports addition of electronic circuits for thermal
compatibility
shutdown and load-short protection circuit as well as
• Simpler heat sink design facilitates thermal design of
pop noise muting which occurs when the power
slim stereo sets
supply switch is turned on and off
Specifications
Maximum Ratings at Ta = 25°C
Parameter Symbol Conditions Ratings Unit
Maximum supply voltage VCC max ±38 V
Thermal resistance θj-c 2.4 °C/W
Junction temperature Tj 150 °C
Operating substrate temperature Tc 125 °C
Storage temperature Tstg –30 to +125 °C
Available time for load shorted tS*1 VCC = ±26 V, RL = 8 Ω, f = 50 Hz, PO = 25 W 2 s
Recommended Operating Conditions Ta = 25°C
Parameter Symbol Conditions Ratings Unit
Recommended supply voltage VCC ±26 V
Load resistance RL 8 Ω
Operating Characteristics at Ta = 25°C, VCC = ±26 V, RL = 8 Ω, VG = 40 dB, Rg = 600 Ω, RL (noninductive)
Ratings
Parameter Symbol Conditions Unit
min typ max
Quiescent current ICCO VCC = ±30 V 10 20 50 mA
PO (1) THD = 0.4%, f = 20 Hz to 20 kHz 25 W
Output power
PO (2) VCC = ±22 V, THD = 1.0%, RL = 4 Ω, f = 1 kHz 25 W
Total harmonic distortion THD PO = 1.0 W, f = 1kHz 0.3 %
Frequency response fL, fH PO = 1.0 W, +0 dB 20 to 50k Hz
–3
Input resistance ri PO = 1.0 W, f = 1kHz 55 kΩ
Output noise voltage VNO *2 VCC = ±30 V, Rg = 10 kΩ 1.2 mVrms
Neutral voltage VN VCC = ±30 V –70 0 +70 mV
Note: Use rated power supply for test unless otherwise specified.
1. Use the transformer power supply shown on the next page when measuring the available time for load shorted and the output noise voltage.
2. Output noise voltage represents the peak value on the rms scale (VTVM). The noise voltage waveform does not include the pulse noise.
Any and all SANYO products described or contained herein do not have specifications that can handle
applications that require extremely high levels of reliability, such as life-support systems, aircraft’s
control systems, or other applications whose failure can be reasonably expected to result in serious
physical and/or material damage. Consult with your SANYO representative nearest you before using
any SANYO products described or contained herein in such applications.
SANYO assumes no responsibility for equipment failures that result from using products at values that
exceed, even momentarily, rated values (such as maximum ratings, operating condition ranges, or other
parameters) listed in products specifications of any and all SANYO products described or contained
herein.
SANYO Electric Co.,Ltd. Semiconductor Bussiness Headquarters
TOKYO OFFICE Tokyo Bldg., 1-10, 1 Chome, Ueno, Taito-ku, TOKYO, 110-8534 JAPAN
O3098HA (OT)/62095HA (OT)/83093YO 5-2405 No. 4549-1/4
STK4026II
[Link]
Package Dimensions
unit: mm
4033
[STK4026 II]
Unit (resistance: Ω, capacitance: F)
Specified Transformer Power Supply
(RP-25 equivalent)
Equivalent Circuit
Sample Application Circuit: 25 W min AF Power Amplifier
Unit (resistance: Ω, capacitance: F)
No. 4549-2/4
STK4026II
[Link]
No. 4549-3/4
STK4026II
[Link]
Specifications of any and all SANYO products described or contained herein stipulate the performance,
characteristics, and functions of the described products in the independent state, and are not guarantees
of the performance, characteristics, and functions of the described products as mounted in the customer’s
products or equipment. To verify symptoms and states that cannot be evaluated in an independent device,
the customer should always evaluate and test devices mounted in the customer’s products or equipment.
SANYO Electric Co., Ltd. strives to supply high-quality high-reliability products. However, any and all
semiconductor products fail with some probability. It is possible that these probabilistic failures could
give rise to accidents or events that could endanger human lives, that could give rise to smoke or fire,
or that could cause damage to other property. When designing equipment, adopt safety measures so
that these kinds of accidents or events cannot occur. Such measures include but are not limited to protective
circuits and error prevention circuits for safe design, redundant design, and structural design.
In the event that any or all SANYO products (including technical data, services) described or contained
herein are controlled under any of applicable local export control laws and regulations, such products must
not be exported without obtaining the export license from the authorities concerned in accordance with the
above law.
No part of this publication may be reproduced or transmitted in any form or by any means, electronic or
mechanical, including photocopying and recording, or any information storage or retrieval system,
or otherwise, without the prior written permission of SANYO Electric Co., Ltd.
Any and all information described or contained herein are subject to change without notice due to
product/technology improvement, etc. When designing equipment, refer to the “Delivery Specification”
for the SANYO product that you intend to use.
Information (including circuit diagrams and circuit parameters) herein is for example only; it is not
guaranteed for volume production. SANYO believes information herein is accurate and reliable, but
no guarantees are made or implied regarding its use or any infringements of intellectual property rights
or other rights of third parties.
This catalog provides information as of December, 1998. Specifications and information herein are
subject to change without notice.
PS No. 4549-4/4