Drive Down Operating Costs,: With The Leader in HVAC Efficiency
Drive Down Operating Costs,: With The Leader in HVAC Efficiency
98%
Energy efficiency
Save energy and
money with HVAC-
optimized drives
drives.danfoss.com
Content
The best in HVAC is now better than ever.......................................... 4 Flexible, modular and adaptable ............................................................. 16
Nothing beats know how and experience........................................ 5 Modular simplicity – A, B and C enclosures....................................... 18
Savings throughout your entire lifecycle............................................ 6 High-power modularity – D, E and F enclosures............................ 20
Guaranteed operation in your application......................................... 7 Engineered for cost savings via intelligent heat
An unsurpassed fit............................................................................................. 8 management, c ompactness and protection.................................... 22
Dedicated fan functionality......................................................................... 9 Optimize performance and grid protection...................................... 24
Air Handling Units.............................................................................................. 9 Connection example........................................................................................ 26
Dedicated pump functionality.................................................................. 10 Technical data....................................................................................................... 27
Your purpose. Your drive. Your way......................................................... 11 Electrical data – A, B, and C enclosures................................................. 28
Free to connect.................................................................................................... 12 Dimensions enclosure sizes A, B and C................................................. 30
Free to equip......................................................................................................... 13 Ordering typecode for A, B and C enclosures.................................. 31
Personalize your drive...................................................................................... 14 Electrical data – D, E and F enclosures.................................................. 32
Integrate safely..................................................................................................... 15 Dimensions enclosure sizes D, E and F................................................. 33
IPM SynRM
Line-start PM motor Synchronous
with buried magnets reluctance motor
and rotor cage
Go outdoors with
extreme-climate
performance from
+50 °C down to
-25°C
Electricity costs
95%
Purchase price
plus installation,
maintenance and
other costs
5%
Total HVAC
cost of Reliabilty expertise
ownership
5
Total cost of ownership
reasons to choose
the VLT® HVAC Drive
1. Energy efficiency
2. Optimal motor control
3. User friendliness
4. Personalize your drive
5. Fieldbus availability
5
Reliability
reasons to choose
the VLT® HVAC Drive
1. Quality
2. Environment
3. Uptime
4. Electrical immunity
5. Global 24/7 support
Quality derating and options for conformal, even when there are spikes and dips in
Our goal has always been to provide harsh environment coating to 3C3, voltage, that the drive will continue to
you with products and systems of the further improves the VLT® HVAC Drive’s operate as expected. Occasionally, an
best possible quality, functionality ability to work in the most demanding AC drive may be connected to a
and efficiency. To improve our environments. system that experiences a short circuit
service to you even further, we have which could potentially destroy the
implemented the ISO/TS 16949 Uptime connected drive. To ensure reliable
standard. This standard builds on the With billions of people all around the operation, the VLT® HVAC Drive is
previous ISO 9001 guidelines but is far world relying on HVAC systems for designed to be short-circuit-proof
more ambitious in scope, addressing comfort and safety, one of the key with a 100 kA prospective short circuit
not just what we should do but how focuses is selecting an AC drive that can current capability.
we should do it. The TS 16949 standard withstand unforseen grid fluctuations
is about understanding your needs that would otherwise interrupt Global 24/7 support
and meeting them with products, operations. To improve ride-through, Should you need any kind of support,
solutions and services that match your the VLT® HVAC Drive relies on a robust any time, at any location, we will be
expectations overvoltage controller, kinetic backup there for you. We understand that your
and an improved flying start which uptime is critical, and we react fast.
Environment ensures reliable operation when it’s
With a wide operating temperature needed most.
down to -25 °C and up to 50 °C and an
availability of enclosure classes up to Electrical immunity
IP66/UL Type 4X, the VLT® HVAC Drive AC drives often require connections
can operate almost anywhere without to grids that are far from perfect. Here
derating. The addition of seismic a host of electrical events can cause
certification, the ability to install to serious issues with drives. Algorithms
altitudes of 2000m/6500ft without in the VLT® HVAC Drive ensure that
When searching for the best AC drive for your application, you want to
find a partner that understands your needs and challenges. With over
30 years dedicated to HVAC applications, we’ve heard your comments
and continually added the most requested features. As a result of your
close cooperation, the VLT® HVAC Drive is a drive that speaks your
language, is reliable enough to be installed where you need it, and
saves you time and money throughout its lifetime.
5
HVAC expertise
reasons to choose
the VLT® HVAC Drive
1. Safety
2. EMC and harmonics
3. Documented savings
4. Efficiency classification
5. Dedicated HVAC functionality
Safety motor cable. These filters are also To support this, our VLT® Energy Box
HVAC applications require a wide and designed to minimize radio-frequency tool can be used to calculate the
varying consideration for safety in order interference (RFI) to even further potential energy savings, based on
to protect both the people around protect sensitive equipment from logged real-life operation data. The VLT®
the equipment and the equipment radiated emissions. HVAC Drive features a built-in energy
itself. To aid this, the VLT® HVAC Drive meter which can be used to see how
features a series of options for basic When AC drives are used, the pulse much energy has been consumed by
and advanced functional safety, ATEX width modulated output waveform each drive in your application.
certified inputs and a lockable mains injects harmonics onto the grid. To help
disconnect as part of the enclosure. mitigate this, VLT® Advanced Harmonic Efficiency classification
This ensures that your AC drive is Filters can be used to guarantee a THDi Using the Danfoss ecoSmart tool, you
suitable for the level of safety that your below 5% from the drive. can enter information about your
application requires. selected motor, load points and the
Documented savings specific VLT® HVAC Drive in order to
EMC and harmonics Almost all owners and operators of AC calculate and document the efficiency
The VLT® HVAC Drive is often drives aim to reduce the amount of of both the drive being used and the
installed in applications alongside energy used in their applications. system efficiency class according to
other highly sensitive electronic Understanding how adding an AC drive EN 50598-2.
equipment. Therefore special care is benefits your particular application and
required to minimize electromagnetic saves energy is extremely useful when Dedicated HVAC functionality
interference. To accomplish this, we’ve engineering a solution. Additionally, the Dedicated fan and pump applications
added EMC filters guaranteed to levels ability to see how much energy is being ensure that the VLT® HVAC Drive always
of Residential Category C1 (up to 50 m used by your drive is extremely valuable meets your needs.
length) for screened motor cable; and to ensuring that your application runs
to levels of Residential Category C2 as efficiently as planned.
(up to 150 m length) for screened
Meet the unique requirements of your applications
Operate at peak performance
Optimize system efficiency
When you have the freedom to select the optimal components for
your system, a potential energy saving of up to 60% is possible.
Fresh air in
Speed
Differential pressure
8
2
7
8
5
3
2
9
10
12
Efficiency is vital
for high-power drives
Efficiency is essential in the design 4
of the high-power VLT® drive series.
Innovative design and exceptionally 5 10
high-quality components have resulted
in unsurpassed energy efficiency. 14
6
VLT® drives pass more than 98% of 7
the supplied electrical energy on to 11
13
the motor. Only 2% or less is left in
the power electronics as heat to be
removed.
Safety
Please see chapter “Integrate Safely”.
15
The AC drives are available in a broad and reduce faults related to high Coated circuit boards
range of enclosure sizes and protection temperatures. The AC drive conforms as standard to
ratings from IP20 to IP54 to enable class 3C3 (IEC 60721-3-3) to ensure long
easy installation in all environments: For example, by exhausting heat lifetime even in harsh environments.
mounted in panels, switch rooms or directly outside, it is possible to reduce
as stand-alone units in the production the size of the cooling system in the
area. panel or switch room. This can be Ruggedized for
achieved with Danfoss’ extremely extra protection
efficient back-channel cooling concept, The AC drive in enclosure size D is
Cost saving heat management allowing heat to be vented outside the available in a ‘ruggedized’ version that
In AC drives there is total separation control room. ensures the components remain firmly
between the back-channel cooling in place in environments characterized
air and the internal electronics. In daily use the benefits are equally by high degrees of vibration, such as
This separation greatly reduces the clear as the energy consumption marine and mobile equipment.
airflow over the sensitive electronics, related to cooling can be reduced
minimizing the exposure to significantly. This means that designers
contaminants. At the same time it can reduce the size of the air
removes heat efficiently which helps conditioning system, or even eliminate
to prolong product life, increase it entirely.
the overall availability of the system
3C3
Coated PCBs as
standard in all high-
power drives
90%
reduction
in investment for air
cooling systems
VLT® Advanced Active Filter AAF allows the drive to be installed in a
VLT® Low Harmonic Drives central control room, away from the -300
VLT® 12-pulse Drives application without affecting motor
8 16 24 32 [ms]
performance.
Provide extra motor protection with:
Harmonic distortion
VLT® Sine-wave Filter Electrical interference reduces e fficiency and risks
VLT® dU/dt Filter harming equipment.
VLT® Common Mode Filters
0
[V]
EMC Standards Conducted emission
-150
EN 55011 Class B Class A Group 1 Class A Group 2
Facility operators must Housing Industrial Industrial
comply with EN 55011 and light industries environment environment
Standards and -300
requirements Category C1 Category C2 Category C3
EN/IEC 61800-3 First First Second
Converter manufacturers 8 16 24 32 [ms]
must conform to EN 61800-3 environment, home environment, home environment
and office and office
Compliance 1) n n n Optimized harmonic performance
Compliance to mentioned EMC classes depends on the selected filter.
1) Efficient harmonic mitigation protects electronics
For further details see the design guides. and increases efficiency.
You’re covered
with DrivePro® Life Cycle service products
Get the most out of your systems, with the help of DrivePro® services
for Danfoss VLT® and VACON® drives. You get services that go beyond
simple t roubleshooting, maintenance, repairs and replacements. DrivePro® app
They also proactively improve productivity, performance and uptime. Use the DrivePro app for fast
access to the DrivePro® services,
for improved productivity,
DrivePro® Retrofit DrivePro® Start-up
performance and uptime of
your systems. Find your closest
DrivePro® Spare Parts DrivePro® Extended Warranty service partner, place a service
request, and register your VLT®
DrivePro® Exchange DrivePro® Remote Expert Support
and VACON® drives. You can also
DrivePro® Upgrade DrivePro® Preventive Maintenance
look up product information,
DrivePro® Life Cycle specifications and manuals for
your specific VLT® or VACON® drive
DrivePro®
Higher performance based on the nameplate product
Pre-sales
support
Training Services
code, or the product name.
More uptime
130BC931.10
91 (L1) (U) 96
3 Phase 92 (L2) (V) 97
power
input 93 (L3) (W) 98
95 PE (PE) 99
Motor
ON
+10Vdc relay1
ON=0/4-20mA
0/4-20 mA S202 03
OFF=0/-10Vdc -
1 2
0/-10Vdc - +10Vdc
ON
54 (A IN) 240Vac, 2A
+10Vdc 02
0/4-20 mA
55 (COM A IN) 01
* relay2
12 (+24V OUT) 06
240Vac, 2A
13 (+24V OUT) P 5-00 05
400Vac, 2A
24V (NPN)
18 (D IN) 04
0V (PNP)
24V (NPN)
19 (D IN) 0V (PNP) (COM A OUT) 39 Analog Output
0/4-20 mA
(A OUT) 42
20 (COM D IN)
24V (NPN)
27 (D IN/OUT) 0V (PNP) S801
24V ON=Terminated
1 2
ON
OFF=Open
0V 5V
* 24V (NPN)
29 (D IN/OUT) 0V (PNP)
24V
S801 0V
0V
RS-485 RS-485
(N RS-485) 69
24V (NPN) Interface
32 (D IN) 0V (PNP) (P RS-485) 68
24V (NPN) **
33 (D IN) 0V (PNP) (COM RS-485) 61
: Chassis
* : Earth
37 (D IN)
This diagram shows a typical These inputs can be set up as either On the 68 (P+) and 69 (N-) terminals’
installation of the VLT® HVAC Drive. reference, feedback or thermistor RS 485 interface, the drive can be
Power is connected to the terminals inputs. controlled and monitored via serial
91 (L1), 92 (L2) and 93 (L3) and the communication.
motor is connected to 96 (U), 97 (V) There are 6 digital inputs to be
and 98 (W). connected to terminals 18, 19, 27, 29,
32, and 33. Two digital input/output
Terminals 88 and 89 are used for load terminals (27 and 29) can be set up
sharing between drives. as digital outputs to show an actual
Analogue inputs can be connected to status or warning or can be used as
the 53 (V or mA), and for 54 (V or mA) pulse reference signal. The terminal 42
terminals. analogue output can show process
values such as 0 - Imax.
Agency approvals
FC-102 Con. IN Inter. IMAX kW @ Hp @ [A] [W] Chassis Type 1 Type 12 Type 4X
(60 s) 208 V 230 V
P1K1 6.6 7.3 1.1 1.5 6.5 63 A2 A2 A4/A5 A4/A5
P1K5 7.5 8.3 1.5 2 7.5 82 A2 A2 A4/A5 A4/A5
P2K2 10.6 11.7 2.2 3 10.5 116 A2 A2 A4/A5 A4/A5
P3K0 12.5 13.8 3 4 12.4 155 A3 A3 A5 A5
P3K7 16.7 18.4 3.7 5 16.5 185 A3 A3 A5 A5
P5K5 24.2 26.6 5.5 7.5 24.2 310 B3 B1 B1 B1
P7K5 30.8 33.9 7.5 10 30.8 310 B3 B1 B1 B1
P11K 46.2 50.8 11 15 46.2 514 B3 B1 B1 B1
P15K 59.4 65.3 15 20 59.4 602 B4 B2 B2 B2
P18K 74.8 82.3 18.5 25 74.8 737 B4 C1 C1 C1
P22K 88 96.8 22 30 88 845 C3 C1 C1 C1
P30K 115 127 30 40 114 1140 C3 C1 C1 C1
P37K 143 157 37 50 143 1353 C4 C2 C2 C2
P45K 170 187 45 60 169 1636 C4 C2 C2 C2
[T4] 3 x 380-480 V AC
Normal overload (110% 1 min/10 min) Enclosure size
Output current Conti Esti- Protection rating [IEC/UL]
Type Typical shaft nuous mated
code (3 x 380-440 V) (3 x 441-480 V) output power input power IP20 IP21 IP55 IP66
current loss
FC-102 Con. IN Inter. IMAX kW @ Hp @ [A] [W] Chassis Type 1 Type 12 Type 4X
(60 s) 575 V 575 V
PK75 1.7 1.9 0.75 1 1.9 35 A3 A3 A5 A5
P1K1 2.4 2.6 1.1 1.5 2.6 50 A3 A3 A5 A5
P1K5 2.7 3 1.5 2 3 65 A3 A3 A5 A5
P2K2 3.9 4.3 2.2 3 4.5 92 A3 A3 A5 A5
P3K0 4.9 5.4 3 4 5.7 122 A2 A2 A5 A5
P4K0 6.1 6.7 4 5 6.4 145 A2 A2 A5 A5
P5K5 9 9.9 5.5 7.5 9.5 195 A3 A3 A5 A5
P7K5 11 12.1 7.5 10 11.4 261 A3 A3 A5 A5
P11K 18 20 11 15 19 300 B3 B1 B1 B1
P15K 22 24 15 20 23 300 B3 B1 B1 B1
P18K 27 30 18.5 25 28 370 B3 B1 B1 B1
P22K 34 37 22 30 36 440 B4 B2 B2 B2
P30K 41 45 30 40 43 600 B4 B2 B2 B2
P37K 52 57 37 50 54 740 B4 C1 C1 C1
P45K 62 68 45 60 65 900 C3 C1 C1 C1
P55K 83 91 55 75 87 1100 C3 C1 C1 C1
P75K 100 110 75 100 105 1500 C4 C2 C2 C2
P90K 131 144 90 125 137 1800 C4 C2 C2 C2
[T7] 3 x 525-690 V AC
Normal overload (110% 1 min/10 min) Enclosure size
Type Output current Typical shaft Continuous Estimated Protection rating [IEC/UL]
code (3 x 525-550 V) (3 x 551-690 V) output power input current power loss IP20 IP21 IP55
Height 10.6 14.8 10.6 14.8 15.4 16.6 18.9 25.6 15.8 20.5 26.8 30.4 21.7 26
Height with decoupling plate 14.8 – 14.8 – – – – – 16.6 23.5 – – 24.8 31.5
Width 3.6 3.6 5.2 5.2 7.9 9.6 9.6 9.6 6.5 9.1 12.2 14.6 12.2 14.6
Width with one C option 5.2 5.2 6.7 6.7 – 9.6 9.6 9.6 8.1 9.1 12.2 14.6 12.2 14.6
[in]
Width with two C options 6 6 7.5 7.5 – 9.6 9.6 9.6 8.9 9.1 12.2 14.6 12.2 14.6
Depth 8.1 18.2 8.1 8.2 6.9 7.9 10.3 10.3 9.8 9.6 12.3 13.2 13 13
Depth with mains disconnect – – – – 8.2 8.9 11.4 11.5 – – 13.6 14.9 – –
Depth with A, B option 8.7 8.8 8.7 8.8 6.9 7.9 10.3 10.3 10.4 9.6 12.3 13.2 13 13
[lb] Weight 10.8 11.7 14.6 15.5 21.5 31.5 50.7 59.6 26.5 52 99.3 143.3 77.2 110.2
FC- – – – – – – – – – – – – – – – CX – – XX –
[T7] 3 x 525-690 V AC
Normal overload (110% 1 min/10 min) Enclosure size
Output current Conti Esti- Protection rating [IEC/UL]
Type Typical shaft nuous mated
code (3 x 525-550 V) (3 x 551-690 V) output power input power IP20 IP21 IP54
current loss
Height 35.5 41.8 25.8 39.6 44.2 50.0 52.2 65.5 77.9 90.0
[in] Width 12.8 16.6 9.9 9.9 13.8 13.8 12.8 12.8 16.6 16.6
Depth 14.9 14.9 14.8 14.8 14.8 14.8 15.0 15.0 15.2 16.0
[lb] Weight 216.1 361.6 216.1 238.1 216.1 394.7 255.8 284.4 441.0 496.1
(1)
dimensions with regeneration or load share terminals
(2)
D5h is used with disconnect and/or brake chopper options
(3)
D6h is used with contactor and/or circuit breaker options
(4)
D7h is used with disconnect and/or brake chopper options
(5)
D8h is used with contactor and/or circuit breaker options
D3h/D4h E1h F
[T7] 3 x 525-690 V AC
Normal overload (110% 1 min/10 min) Enclosure size
Output current Conti Esti- Protection rating [IEC/UL]
Type Typical shaft nuous mated
code (3 x 525-550 V) (3 x 551-690 V) output power input power IP21/Type 1 IP54/Type 12
current loss
VLT® 12-pulse
FC- – – – – – – – – – – – – – – – CX – – XX –
[1] Application (character 4-6) IP21 / Type 1 – Stainless steel back channel RCD for TN/TT mains with Class A2 RFI
C2H HE
102 VLT® HVAC Drive + space heater (Enclosure sizes F1, F2, F3, F4)
[2] Power size (character 7-10) IP21 / Type 1 + cabinet light HX No RFI filter
L2A + 115 V power outlet
N75K 75 kW / 100 Hp RCD for TN/TT mains and Class A1 RFI
HF
IP21 / Type 1 + cabinet light (Enclosure sizes F1, F2, F3, F4)
N90K 90 kW / 125 Hp L2X + 230 V power outlet
IRM for IT mains and Class A1 RFI
N110 110 kW / 150 Hp HH
IP21 / Type 1 + space heater + cabinet light (Enclosure sizes F1, F2, F3, F4)
R2A
N132 132 kW / 200 Hp + 115 V power outlet
VLT® Low Harmonic Drive
N160 160 kW / 250 Hp IP21 / Type 1 + space heater + cabinet light
R2X VLT® Low Harmonic Drive, active filter
+ 230 V power outlet N2
N200 200 kW / 300 Hp based with Class A2 RFI
N250 250 kW / 350 Hp IP21 / Type 1 – Stainless steel back channel VLT® Low Harmonic Drive, active filter
C2E N4
+ Cooling out the back based with Class A1 RFI
N315 315 kW / 450 Hp
IP21 / Type 1 – Stainless steel back channel VLT® 12-Pulse, encl. sizes F8, F9, F10, F11, F12, F13
P315 315 kW / 450 Hp C2J + cooling out the back + space heater
N355 355 kW / 500 Hp B2 12-Pulse with Class A2 RFI
E2E IP21 / Type 1 – cooling out the back
P355 355 kW / 500 Hp B4 12-Pulse with Class A1 RFI
IP21 / Type 1 – cooling out the back
E2J BE 12-Pulse with RCD / A2 RFI
N400 400 kW / 550 Hp + space heater
P400 400 kW / 550 Hp IP54 / UL Type 12 enclosures BF 12-Pulse with RCD / A1 RFI
N450 450 kW / 600 Hp E54 IP54 / Type 12 BG 12-Pulse with IRM / A2 RFI
P450 450 kW / 600 Hp E5D IP54 / Type 12 (D1, D1h, D5h, D6h frames) BH 12-Pulse with IRM / A1 RFI
N500 500 kW / 650 Hp E5M IP54 / Type 12 + mains shield [6] Braking and safety (character 18)
P500 500 kW / 650 Hp H54 IP54 / Type 12 + space heater + thermostat X No brake IGBT
N560 560 kW / 750 Hp C54 IP54 / Type 12 – Stainless steel back channel B Brake IGBT
P560 560 kW / 750 Hp IP54 / Type 12 – Stainless steel back channel Safe Torque Off with Pilz Safety Relay
C5M C
+ mains shield (enclosure sizes F1, F2, F3, F4)
N630 630 kW / 900 Hp
IP54 / Type 12 – Stainless steel back channel Safe Torque Off with Pilz Safety Relay
P630 630 kW / 900 Hp C5H D and brake IGBT
+ space heater
N710 710 kW / 1000 Hp (enclosure sizes F1, F2, F3, F4)
IP54 / Type 12 + cabinet light
P710 710 kW / 1000 Hp L5A Safe Torque Off with Pilz Safety Relay and
+ 115 V power outlet
N800 800 kW / 1200 Hp E regeneration terminals
IP54 / Type 12 + cabinet light (enclosure sizes F1, F2, F3, F4)
L5X
P800 800 kW / 1200 Hp + 230 V power outlet
T Safe Torque Off without brake
P900 900 kW / 1250 Hp IP54 / Type 12 + space heater + cabinet light
R5A R Regeneration terminals (enclosure sizes D & F)
P1M0 1.0 MW / 1350 Hp + 115 V power outlet
S Regeneration terminals and brake chopper
P1M2 1.2 MW / 1600 Hp IP54 / Type 12 + space heater + cabinet light
R5X + 230 V power outlet U Brake IGBT plus Safe Torque Off
P1M4 1.4 MW / 1900 Hp
E5E IP54 / Type 12 – cooling out the back Enclosure sizes F3, F4
[3] AC mains voltage (character 11-12)
IP54 / Type 12 – Stainless steel back channel IEC Emergency Stop Pushbutton
T4 3 x 380-480 V AC C5E M
+ cooling out the back (includes Pilz Relay)
3 x 525-690 V AC IP54 / Type 12 – Stainless steel back channel
T7 C5J IEC Emergency Stop Pushbutton with brake
690 V kW. See manuals for 575 V Hp + cooling out the back + space heater N IGBT and brake terminals
[4] IP/UL protection ratings (character 13-15) (includes Pilz Safety Relay)
IP54 / Type 12 – cooling out the back
E5J
IP00 / Chassis enclosures + space heater IEC Emergency Stop Pushbutton with
E00 IP00 / Chassis (D4, E2 enclosures) IP66 / UL Type 4X enclosures P regeneration terminals
(includes Pilz Safety Relay)
C00 IP00 / Chassis – Stainless steel back channel E66 IP66 / Type 4X
[7] LCP display (character 19)
IP20 / Chassis enclosures Y66 IP66 / Type 4X + backplate (no C-options)
X Blank faceplate, no LCP installed
E21 IP21 / Type 1 Z66 IP66 / Type 4X (no C-options)
N Numerical Local Control Panel (LCP 101)
E2M IP21 / Type 1 + mains shield [5] R
FI filter, terminal and monitoring options
– EN/IEC 61800-3 (character 16-17) G Graphical Local Control Panel (LCP 102)
E2D IP21 / Type 1 (D1h, D5h, D6h enclosures)
H2 RFI filter, Class A2 (C3) Enclosure size D and E, IP21/IP54 only
H21 IP21 / Type 1 + space heater
J No Local Control Panel + USB through door
C21 IP21 / Type 1 – Stainless steel back channel RFI filter, Class A1 (C2)
H4 (Enclosure sizes D and F only) Graphical Local Control Panel (LCP 102)
IP21 / Type 1 – Stainless steel back channel L
C2M + USB through door
+ mains shield RFI filter, Class A2 (C3)
H5 Marine ruggedized Numerical Local Control Panel (LCP 101)
IP21 / Type 1 – Stainless steel back channel K
C2D + USB through door
(D1h, D5h, D6h enclosures) IRM for IT mains with Class A2 RFI
HG (Enclosure sizes F1, F2, F3, F4)
FC- – – – – – – – – – – – – – – – CX – – XX –
[8] PCB coating – IEC 721-3-3 (character 20) [10] Hardware option A (character 22) [13] LCP language (character 28)
X Standard coated PCB Class 3C2 X Standard cable entries Standard language package including
C Coated PCB Class 3C3 Enclosure sizes F1, F2, F3, F4, F10, F11, F12, F13, F18 X English, German, French, Spanish, Danish,
Italian, Finnish and others
R Coated PCB Class 3C3 + ruggedized E 30 A fuse protected power terminals
Contact factory for other language options
[9] Mains input (character 21) 30 A fuse protected power terminals and
F [14] A-options: Fieldbus (character 29-30)
X No mains option 2.5-4 A manual motor starter
AX No option
7 Fuses 30 A fuse protected power terminals and
G 4-6.3 A manual motor starter A0 VLT® PROFIBUS DP MCA 101
Fuses and load sharing terminals
A (enclosure sizes D/IP20 and F3, F4, F9, F11, 30 A fuse protected power terminals and A4 VLT® DeviceNet MCA 104
H
F14, F18 only) 6.3-10 A manual motor starter
AG VLT® LonWorks MCA 108
30 A fuse protected power terminals and AJ VLT® BACnet MCA 109
Load sharing terminals J 10-16 A manual motor starter
D (enclosure sizes D/IP20 and F3, F4, F9, F11, F14, AL VLT® PROFINET MCA 120
F18 only) K Two 2.5-4 A manual motor starters
AN VLT® EtherNet/IP MCA 121
Mains disconnect + fuse L Two 4-6.3 A manual motor starters
3 AQ VLT® Modbus TCP MCA 122
(enclosure sizes D, E and F3, F4, F9, F11, F14, F18)
M Two 6.3-10 A manual motor starters
4 Mains contactor + fuse (enclosure size D) AK VLT® BACnet/IP MCA 125
N Two 10-16 A manual motor starters
[15] B-options (character 31-32)
Mains disconnect, fuse and load sharing [11] H
ardware option B (character 23)
5 (Not available for enclosure size F18) BX No application option
X No adaptation
Mains disconnect + contactor + fuse BK VLT® General Purpose MCB 101
E Heat sink access panel
(enclosure sizes D, E and F3, F4, F9, F11, F14, F18) Q (enclosure size D and E only) BP VLT® Relay Option MCB 105
Circuit breaker + fuse B0 VLT® Analog I/O Option MCB 109
J Enclosure sizes F1, F2, F3, F4, F10, F11, F12, F13, F18
(enclosure sizes D, E and F3, F4, F9, F11, F14, F18)
5 A 24 V supply (customer use) and B2 VLT® PTC Thermistor Card MCB 112
Mains circuit breaker, contactor and fuses G
F external temperature monitoring B4 VLT® Sensor Input Card MCB 114
(enclosure sizes F3, F4, F9, F11, F14, F18)
H 5 A 24 V supply (customer use) [16] C0-option (character 33-34)
Mains disconnect, contactor, load sharing
G terminals and fuses J External temperature monitoring CX No option
(enclosure sizes F3, F4, F9, F11, F14, F18)
K Common motor terminals [17] Extended relay (character 35)
Mains circuit breaker, contactor, load sharing L 5 A 24 V supply + common motor terminals X No option
H terminals and fuses
(enclosure sizes F3, F4, F9, F11, F14, F18) External temperature monitoring + common R VLT® Extended Relay Card MCB 113
M motor terminals
[18] Motion software (character 35)
Mains circuit breaker, load share and fuses
K 5 A 24 V supply + external temperature
(enclosure sizes F3, F4, F9, F11, F14, F18) N XX No software option
monitoring + common motor terminals
Cable connection cabinet [19] Control Power Back-up Input (character 38-39)
T [12] Special version (character 24-27)
(enclosure size D only) DX No DC input installed
SXXX Latest released standard software
Cable connection cabinet and fuse D0 VLT® 24 V DC Supply Option MCB 107
W (enclosure size D only)
Please beware that not all combinations are possible.
Find help configuring your drive with the online
configurator found under: driveconfig.danfoss.com
Dimensions – VLT® Advanced Active Filter and VLT® Low Harmonic Drive
VLT® Advanced Active Filter VLT® Low Harmonic Drive
Enclosure size D1n D2n E9 D14 E1
IP21 / Type 1 IP21 / Type 1
Protection rating [IEC/UL] IP54 / Type 12 IP54 / Type 12
Height 1915.91 1914.7 2000.7 1780.0 2000.0
[mm] Width 929.2 1024.2 1200.0 600.0 600.0
Depth 418.4 418.4 538.0 418.4 538.0
[kg] Weight 353.0 413.0 676.0 238.0 453.0
VLT® Advanced Active Filter AAF 006 VLT® Low Harmonic Drive
PROFIBUS DP BACnet MS/TP The option offers advanced features such as:
Built-in high performance switch enabling
The BACnet protocol is an international
Operating the AC drive via a fieldbus enables protocol that efficiently integrates all parts line-topology, and eliminating the need for
you to reduce the cost of your system, commu- of building automation equipment from the external switches
nicate faster and more efficiently and benefit actuator level to the building management DLR Ring
from an easier user interface. system. Advanced switch and diagnosis functions
Built-in web server
Other features: Via the BACnet option, it is possible to read all E-mail client for service notification
Wide compatibility, a high level of availabi- analog and digital inputs and control all analog Unicast and Multicast communication
lity, support for all major PLC vendors, and and digital outputs of the VLT® HVAC Drive and
compatibility with future versions VACON® NXS. VLT® EtherNet/IP MCA 121
Fast, efficient communication, transparent
installation, advanced diagnosis and para- All inputs and outputs can be operated Order code
meterization and auto-configuration independently of the functions of the drive, 130B1119 standard, dual-port
of process data via GSD-file and thus work as remote I/O: 130B1219 coated, dual-port
Acyclic parameterization using PROFIBUS
DP-V1, P ROFIdrive or Danfoss FC Other features:
(MCA101 only) profile state machines,
PROFIBUS DP-V1, Master Class 1 and 2
COV (Change of Value) Modbus TCP
Synchronization of RTC from BACnet
Read/write property multiple Modbus TCP is the first industrial Ethernet-
VLT® PROFIBUS DP MCA 101 Alarm/warning handling based protocol for automation. Modbus TCP is
able to handle connection intervals down to 5
Order code VLT® BACnet MCA 109 ms in both directions, positioning it among the
130B1100 standard fastest performing Modbus TCP devices in the
130B1200 coated Order code market. For master redundancy, it features hot
130B1144 standard swapping between two masters.
130B1244 coated
DeviceNet Other features:
Dual Master PLC connection for redundancy
DeviceNet offers robust, efficient data han- in dual port options (MCA 122 only)
dling thanks to advanced Producer/Consumer PROFINET
technology. PROFINET uniquely combines the highest VLT® Modbus TCP MCA 122
performance with the highest degree of
Support of ODVA’s AC drive profile suppor- openness. The option is designed so that many Order code
ted via I/O instance 20/70 and 21/71 secures of the features from the PROFIBUS can be 130B1196 standard, dual-port
compatibility to existing systems reused, minimizing user effort to migrate 130B1296 coated, dual-port
Benefit from ODVA’s strong conformance PROFINET and securing the investment in
testing policies, which ensure that products a PLC program.
are interoperable
BACnet/IP
Same PPO types as PROFIBUS for easy
VLT® DeviceNet MCA 104 migration to PROFINET The BACnet/IP option optimizes the use of VLT®
Support of MRP HVAC Drive together with building manage-
Order code Support of DP-V1 Diagnostic allows easy, ment systems (BMS) using the BACnet/IP proto-
130B1102 standard fast and standardized handling of warning col or running BACnet on Ethernet. BACnet/IP
130B1202 coated and fault information into the PLC, makes it easy to control or to monitor points
improving bandwidth in the system required in typical HVAC applications, reducing
Implementation in accordance with overall cost of ownership.
LonWorks Conformance Class B
Other features:
LonWorks is a fieldbus system developed for VLT® PROFINET MCA 120 COV, Change Of Value
building automation. It enables communi- Read/WritePropertyMultiple
cation between individual units in the same Order code Alarm/Warning notifications
system (peer-to-peer) and thus supports 130B1135 standard, dual-port PID Loop object
decentralizing of control. 130B1235 coated, dual-port Segmented data transfer
Trend Objects
No need for main station (master-follower) Schedule Objects
Supports echelon free-topology interface
Supports embedded I/O and I/O options EtherNet/IP VLT® BACnet/IP MCA 125
Sensor signals can quickly be moved to Ethernet is the future standard for communica-
another controller via bus cables tion at the factory floor. EtherNet/IP is based on Order code
Certified as compliant with LonMark the newest technology available for industrial 134B1586 coated, dual-port
ver. 3.4 specifications use and handles even the most demanding
(VLT® LonWorks MCA 108 only) requirements.
EtherNet/IP™ extends commercial off-the-shelf
VLT® LonWorks MCA 108 Ethernet to the Common Industrial Protocol
(CIP™) – the same upper-layer protocol and
Order code object model found in DeviceNet.
130B1106 standard
130B1206 coated
VLT® General Purpose I/O VLT® Analog I/O Option VLT® Sensor Input Card
MCB 101 MCB 109 MCB 114
This I/O option offers an extended number of This analog input/output option is easily fitted This option protects the motor from being
control inputs and outputs: in the AC drive for upgrading to advanced overheated by monitoring the temperature of
performance and control using the additional bearings and windings in the motor.
3 digital inputs 0-24 V: Logic ‘0’ < 5 V; Logic I/O. This option also upgrades the AC drive with
‘1’ > 10V a battery back-up supply for the AC drive built- Protects the motor from overheating
2 analog inputs 0-10 V: Resolution 10 bit in clock. This provides stable use of all AC drive 3 self-detecting sensor inputs for 2 or 3 wire
plus sign clock functions as timed actions. PT100/PT1000 sensors
2 digital outputs NPN/PNP push pull 1 additional analog input 4-20 mA
1 analog output 0/4-20 mA 3 analog inputs, each configurable as both
Spring-loaded connection voltage and temperature input Ordering number
Connection of 0-10 V analog signals as well 130B1172 standard
Ordering number as Pt1000 and Ni1000 temperature inputs 130B1272 coated (Class 3C3/IEC 60721-3-3)
130B1125 standard 3 analog outputs each configurable as 0-10
130B1212 coated (Class 3C3/IEC 60721-3-3) V outputs
Back-up supply for the standard clock func-
tion in the AC drive VLT® Safety Option
VLT® Relay Card MCB 105 MCB 140 and MCB 141
The back-up battery typically lasts for 10 years,
depending on environment. VLT® Safety Option MCB 140 and MCB 141
Makes it possible to extend relay functions with comprise safety options with Safe Stop 1 (SS1),
3 additional relay outputs.
Ordering number Safely Limited Speed (SLS) and Safe Speed
130B1143 standard Monitor (SSM) functionality.
Max. switch rate at rated
load/min. load ................................ 6 min-1/20 sec-1 130B1243 coated (Class 3C3/IEC 60721-3-3)
The options can be used up to PL e according
Protects control cable connection to ISO 13849-1.
Spring-loaded control wire connection
MCB 140 is a standard B-Option. MCB 141
Max. terminal load: VLT® PTC Thermistor Card offers the same functionality in an external 45
AC-1 Resistive load ............................ 240 V AC 2 A
MCB 112 mm housing. MCB 141 enables the user to use
AC-15 Inductive MCB 140 functionality also if another B-Option
load @cos phi 0.4 ............................240 V AC 0.2 A The VLT® PTC Thermistor Card is used.
DC-1 Resistive load ...............................24 V DC 1 A MCB 112 enables improved surveillance of the
DC-13 Inductive motor c ondition compared to the built-in ETR Different operating modes can be configured
load @cos phi 0.4 .............................. 24 V DC 0.1 A function and thermistor terminal. easily by using the on board display and but-
tons. The options provide only a limited set of
Min. terminal load: Protects the motor from overheating parameters for fast parameterization.
DC 5 V........................................................................10 mA ATEX-approved for use with Ex d and Ex e
motors (EX e only FC 302) MCB 140 standard B-Option
Ordering number Uses Safe Stop function, which is approved MCB 141 external option
130B1110 standard in accordance with SIL 2 IEC 61508 Single-channel or dual-channel operation
130B1210 coated (Class 3C3/IEC 60721-3-3) possible
Ordering number Proximity switch as speed feedback
NA standard SS1, SLS and SMS functionality
130B1137 coated (Class 3C3/IEC 60721-3-3) Easy and fast parameterization
Ordering number
130B6443 MCB 140, 130B6447 MCB 141
VLT® Sine-wave Filter VLT® Common Mode Filter VLT® Brake Resistor MCE 101
MCC 101 MCC 105 Energy generated during braking is
absorbed by the resistors, protecting
VLT® Sine-wave Filters are positioned bet- Positioned between the AC drive and the electrical components from heating up
ween the AC drive and the motor to provide motor Optimized for the FC-series and general
a sinusoidal phase-to-phase motor voltage They are nano-crystalline cores that mitigate versions for horizontal and vertical motion
Reduces motor insulation stress high frequency noise in the motor cable are available
Reduces acoustic noise from the motor (shielded or unshielded) and reduce bearing Built-in thermo switch
Reduces bearing currents (especially in large currents in the motor Versions for vertical and horizontal
motors) Extends motor bearing lifetime mounting
Reduces losses in the motor Prolongs ser- Can be combined with dU/dt and sine-wave A selection of the vertically mounted units
vice lifetime filters are UL-recognized
VLT® FC series family look Reduces radiated emissions from the motor
cable Power range
Power range Reduces electromagnetic interference Precision electrical match to each individual
3 x 200-500 V, 2.5-800 A Easy to install – no adjustments necessary VLT® drive power size
3 x 525-690 V, 4.5-660 A Oval shaped – allows mounting inside the
frequency converter enclosure or motor Enclosure ratings:
Enclosure ratings terminal box IP20
IP00 and IP20 wall-mounted enclosures IP21
rated up to 75 A (500 V) or 45 A (690 V) Power range IP54
IP23 floor-mounted enclosures rated 115 A 380-415 V AC (50 and 60 Hz) IP65
(500 V) or 76 A (690 V) or more 440-480 V AC (60 Hz)
IP54 both wall-mounted and floor-mounted 600 V AC (60 Hz) Ordering number
enscloures rated up to 4.5 A, 10 A, 500-690 V AC (50 Hz) See relevant Design Guide
22 A (690 V)
Ordering number
Ordering number 130B3257 Enclosure size A and B
See relevant Design Guide 130B7679 Enclosure size C1 VLT® Line Reactor MCC 103
130B3258 Enclosure size C2, C3 and C4
130B3259 Enclosure size D Ensures current balance in load-sharing ap-
130B3260 Enclosure size E and F plications, where the DC-side of the rectifier
VLT® dU/dt Filter MCC 102 of multiple drives is connected together
UL-recognized for applications using load
Reduces the dU/dt values on the motor sharing
terminal phase-to-phase voltage VLT® Advanced Harmonic When planning load-sharing applications,
Positioned between the AC drive and the
Filter AHF 005 and AHF 010 pay special attention to different enclosure
motor to eliminate very fast voltage chan- type combinations and inrush concepts
ges Optimized harmonic performance for For technical advice regarding load-sharing
The motor terminal phase-to-phase voltage VLT® drives rated up to 250 kW applications, contact Danfoss application
is still pulse shaped but its dU/dt values are A patented technique reduces THD levels in support
reduced the mains network to less than 5-10% Compatible with VLT® HVAC Drive
Reduces stress on the motor’s insulation Perfect match for industrial automation, 50 Hz or 60 Hz mains supply
and are recommended in applications with highly dynamic applications and safety
older motors, aggressive environments or installations Ordering number
frequent braking which cause increased DC See relevant Design Guide
link voltage Power range
VLT® FC series family look 380-415 V AC (50 and 60 Hz)
440-480 V AC (60 Hz)
Power range 600 V AC (60 Hz)
3 x 200-690 V (up to 880 A) 500-690 V AC (50 Hz)
Enclosure ratings Enclosure ratings
IP00 and IP20/IP23 enclosure in the entire IP20
power range (An IP21/NEMA 1 upgrade kit is available)
IP54 enclosure available up to 177 A IP00
(Forced cooling is required. There is no fan
Ordering number in the IP00 unit. Separate cooling measures
See relevant Design Guide must be implemented in the cabinet as part
of the installation)
Ordering number
See relevant Design Guide
Fuses 9 – n
NEMA 3R outdoor USB in the door kit Enclosure size F top entry kit
weather shield Available for all enclosure sizes, this USB motor cables
extension cord kit allows access to the drive
Designed to be mounted over the VLT® drive To use this kit, the drive must be ordered with
controls via laptop computer without opening
to protect from direct sun, snow and falling the common motor terminal option. The
the drive.
debris. Drives used with this shield must be kit includes everything to install a top entry
The kits can only be applied to drives manu-
ordered from the factory as “NEMA 3R Ready”. cabinet on the motor side (right side) of an F
factured after a certain date. Drives built prior
This is an enclosure option in the type code size enclosure.
to these dates do not have the provisions to
– E5S. accommodate the kits. Reference the following
table to determine which drives the kits can be Ordering number
Ordering number F1/F3, 400 mm.................................................... 176F1838
applied to.
D1h............................................................................ 176F6302 F1/F3, 600 mm.....................................................176F1839
D2h............................................................................ 176F6303 F2/F4 400 mm.....................................................176F1840
IP20
D1h, D2h, D3h, D4h, D5h, D6h, D7h and D8h. F2/F4, 600 mm.....................................................176F1841
F8, F9, F10, F11, F12, F13.................. Contact factory
IP21/IP54
D1h, D2h, D3h, D4h, D5h, D6h, D7h, D8h and F.
Discover more case stories for the HVAC industry here: http://drives.danfoss.com/industries/hvac/case-stories/#/