Table of Contents/Introduction Index
Traction Control Catalog
X05-FD10 Traction Manifold
OPERATION This valve provides electrically actuated Schematic
traction control for hydrostatic systems
with one pump and two motors in
parallel. In normal operation, fluid
passes freely through the valve. When
the solenoid is energized, fluid is forced
through the flow divider/combiner,
preventing wheel spin or motor over
speed.
PERFORMANCE Performance curve
Pressure drop
psi bar 33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
500 35
400 28
11
33
Specifications
66
Rated pressure 207 bar [3000 psi]
300 21
Rated flow at 7 bar 45 l/min
200 14
[100 psi] [12 US gal/min]
X05-FD10 Traction Manifold
100 7 BYPASS Weight 2.79 kg [6.15 lb]
Bypass Cracking Pressure 3.1 bar [45 psi]
TR - Traction Control
Flow
0
0 9 19 28 38 50 L/min
0 2.4 4.8 7.2 9.6 12 US gal/min
DIMENSIONS
167.4 [6.59]
mm [in] Approx.
107 [4.25]
69.9 [2.75]
50.8 [2.00] 50.8 [2.00] 50.8 [2.00]
22.4 [0.88]
12.7 [0.50]
0.0 0.0 0.0
12.7 [0.50]
31.8 [1.25]
44.5 [1.75]
63.5 [2.50]
76.2 [3.00]
88.9 [3.50]
63.5 [2.50]
88.9 [3.50]
63.5 [2.50]
0.0
0.0
0.0
8.74 [0.344]
Thru - 2 Plcs.
ORDERING
INFORMATION
TR- 2 11141723 • Rev CB • March 2018
Table of Contents/Introduction Index
Traction Control Catalog
X05-FD16 Traction Manifold
OPERATION This valve provides electrically actuated Schematic
traction control for hydrostatic systems
with one pump and two motors in
parallel. In normal operation, fluid
passes freely through the valve. When
the solenoid is energized, fluid is forced
through the flow divider/combiner,
preventing wheel spin or motor over
speed.
PERFORMANCE Performance curve
Pressure drop
psi bar 33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
500 35
1212 1515
400 28
0909 Specifications
300 21 Rated pressure 350 bar [5075 psi]
2020
Rated flow at 7 bar 150 l/min
200 14
[100 psi] [40 US gal/min]
X05-FD16 Traction Manifold
100 7 BYPASS Weight 4.48 kg [9.88 lb]
Flow
Bypass cracking pressure 3.8 bar [55 psi]
TR - Traction Control
0
0 34 68 102 136 170 L/min
0 8 16 24 32 40 US gal/min
DIMENSIONS
mm [in]
ORDERING
INFORMATION
11141723 • Rev CB • March 2018 TR- 3
Table of Contents/Introduction Index
Traction Control Catalog
X05-FD104 Traction Manifold
OPERATION This valve provides electrically actuated Schematic
traction control for hydrostatic systems
with one pump and four motors in
parallel. In normal operation, fluid
passes freely through the valve. When
the solenoid is energized, fluid is forced
through the flow divider/combiners. The
result is equal flow to all four motors,
preventing wheel spin or motor over
speed.
PERFORMANCE Performance curve
Pressure drop
psi bar 33 cSt [154 SUS] hyd.oil at 38°C [100 °F]
1000 70
0606 33 1212 66
800 56
600 42
X05-FD104 Traction Manifold
400 28
TR - Traction Control
200 14 BYPASS
Flow
0
0 25 50 75 100 125 L/min
0 6 12 18 24 30 US gal/min
Specifications
Rated pressure 207 bar [3000 psi]
Rated flow at 7 bar 45 l/min
[100 psi] [12 US gal/min]
Weight 8.74 kg [19.74 lb]
Bypass cracking pressure 3.1 bar [45 psi]
ORDERING
INFORMATION
DIMENSIONS See next page.
TR- 4 11141723 • Rev CB • March 2018
Table of Contents/Introduction Index
Traction Control Catalog
X05-FD104 Traction Manifold (continued)
DIMENSIONS
mm [in]
X05-FD104 Traction Manifold
1/2-13 UNC-2B
TR - Traction Control
25.4 [1.00] MIN GD THD
2 PLCS
11141723 • Rev CB • March 2018 TR- 5
Table of Contents/Introduction Index
Traction Control Catalog
LFB12
OPERATION & The Loop Flushing Block allows oil to Specifications
APPLICATION drain from the power transmission loop Rated pressure 350 bar [5075 psi]
to other oil treatment components. Rated flow See performance chart
The low pressure side of the circuit is Weight 3.4 kg [7.5 lb]
directed to the relief valve, which is then Valves CP721-3 [Shuttle]
drained out of the transmission loop. CP210-1 [Relief ]
M12 orifice plug
This HIC is typically used in closed Material Ductile Iron
loop circuits to assist in the process of
removing contamination and cooling Schematic
oil. Hydrostatic systems with sustained Closed Center Open Center
DR DR
operation and continuous pressure
will benefit from a loop flushing circuit.
To configure the LFB12, determine the
charge pump pressure and desired
flushing flow. Working up from the
desired flow, select the orifice size
with a pressure rise that, when added
to one of the available relief settings
(in the ordering information section),
TR - Traction Control
A B A B
meets the charge pump pressure.
GA GB GA GB
LFB12
PERFORMANCE Pressure rise per orifice option
CHART psi bar
33 cSt [154 SUS] hyd. oil at 38°C [100°F]
20
2.5mm 3.0mm 3.5mm 4.0mm 4.5mm 5.0mm
250
15
Charge pressure minus relief setting
200
150
10
None
100
50
0 0
0 10 20 30 40 50 lpm
0 2 4 6 8 10 12 gpm
Flow
TR- 6 11141723 • Rev CB • March 2018
Table of Contents/Introduction Index
Traction Control Catalog
LFB12
DIMENSIONS
mm [in]
TR - Traction Control
LFB12
ORDERING
INFORMATION
LFB12 - C - 17 - 3.0 - B - S8S
Spool Center Port Sizes
C = Closed S8S = 8S SAE [A, B, & DR]
6S SAE [GA & GB]
O = Open
S4B = ½ BSP [A, B, & DR]
Relief Setting ¼ BSP [GA & GB]
07 = 07 bar [100 psi]
10 = 10 bar [150 psi]
14 = 14 bar [200 psi] Seal Material
17 = 17 bar [250 psi] B = Buna
21 = 21 bar [300 psi] Orifice Option
24 = 24 bar [350 psi] V = Viton
28 = 28 bar [400 psi] 00 = None
2.5 = ø2.5mm
3.0 = ø3.0mm
3.5 = ø3.5mm
4.0 = ø4.0mm
4.5 = ø4.5mm
5.0 = ø5.0mm
11141723 • Rev CB • March 2018 TR- 7