100% found this document useful (1 vote)
2K views60 pages

Manual Valvula Runxin Editado

This document provides an overview and instructions for the EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE. It can be used for water softening and filtration systems. The valve has simple structure, reliable sealing, and allows for manual or automatic regeneration. It also features long outage indication, button lock function, and interval backwash settings. The document provides details on installation, settings, applications, and troubleshooting of the valve.

Uploaded by

Michelle Subieta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
2K views60 pages

Manual Valvula Runxin Editado

This document provides an overview and instructions for the EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE. It can be used for water softening and filtration systems. The valve has simple structure, reliable sealing, and allows for manual or automatic regeneration. It also features long outage indication, button lock function, and interval backwash settings. The document provides details on installation, settings, applications, and troubleshooting of the valve.

Uploaded by

Michelle Subieta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
  • Product Overview

EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Multi-functional Flow Control Valve


for
Water Treatment Systems
For models:

F63P1, F63P3
F68P1, F68P3
F65P1, F65P3
F69P1, F69P3
F67P1
F71P1

User Manual

Please read this manual in details before using the valve and
keep it properly in order to consult in the future!
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Before the valve put into use, please fill in the below content for future
reference.

The Program Type Setting (Operation by professional)

When all symbols light no, press and hold and buttons for 5
seconds to enter the menu of valve model selection. Please set the
program type in accordance with the product type. (Time clock type
by days or hours or Meter type). For example,F63P1 should be set as
F63B1; F63P3 should be set as F63P3. It should not be set to other
type.)

Softener System Configuration

Parameter Setting

Factory Actual
Parameter Unit
Default Value
Control Mode A-01/02
/ A-01
(P3 meter type available)
Unit Mode HU1/2
/ HU01
(P3 meter type available)
Water Treatment Capacity
m3 10
(P3 meter type available)
Service Days(Time type by day) D. 03
Regeneration Time / 02∶00
Backwash Interval Times
/ F-00
(F68P/F69P have the item)
Rinsing Frequence
/ F-00
(F67P/F71P have the item)
Backwash Time min. 10
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Catalogue

Notice ...........................................................................................................
1. Product Overview .....................................................................................
1.1. Main Application & Applicability .....................................................
1.2. Product Characteristics ..................................................................
1.3. Service Conditions .........................................................................
1.4. Product Structure and Technical Parameters ................................
1.5. Installation ......................................................................................
2. Basic Setting & Usage .............................................................................
2.1. The Function of PC Board .............................................................
2.2. Basic Setting & Usage ...................................................................
3. Applications ..............................................................................................
3.1. Softener and Filter Flow Chart .......................................................
3.2. The Function and Connection of PC Board ...................................
A. Signal Output Connector ...........................................................
B. Interlock .....................................................................................
C. Interlock System........................................................................
3.3. System Configuration and Flow Rate Curve .................................
3.4. Parameter Settlement ....................................................................
3.5. Parameter Enquiry and Setting......................................................
3.6. Trial Running...............................................................................
3.7. Trouble-Shooting............................................................................
3.8. Assembly & Component Codes .....................................................
4. Warranty Card ..........................................................................................
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Notice
 To ensure normal operation of the valve, please consult with
professional installation or maintenance personnel before use it.
 Any pipeline engineering and electric works should be finished by
professional in the time of installation.
 Do not use the control valve with the water of unsafe or unknown
quality.
 Depending on the changes of working environment and water
requirements, softening parameters should be adjusted accordingly.
 When the water treatment capacity is too low, please check the resin. If
the cause is shortage of resin, please add it; if the resin turns reddish,
brown or broken, please replace it.
 Test water periodically to verify that system performs satisfactorily.
 Sodium used in the water softening process should be considered as
part of your overall dietary salt intake. Contact your doctor if you are on a
low sodium diet.
 Ensure that there is solid salt all the time in the brine tank in the course
of using, when this valve is used for softening. The brine tank should be
added by the clean water softening salts only, at least 99.5% pure. It is
forbidden to use fine salt.
 Do not put the valve near heat sources or surroundings with high
humidity, corrosive, intense magnetic field or intense librations
environment. And do not leave it outside.
 Forbidden to carry the injector body. Avoid to use injector body as
support to carry the system.
 Forbidden to use the brine tube or other connectors as support to carry
the system.
 Please use this product at water temperatures between 5~50℃,
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

water pressure 0.15~0.6MPa. Failure to use this product under such


conditions voids the warranty.
 If the water pressure exceeds 0.6Mpa, a pressure-relief valve must
be installed before the water inlet; if the water pressure under 0.15MPa,
a booster pump must be installed before the water inlet.
 It is suggested to install PPR pipe, corrugated pipe or UPVC pipe,
rather than TTLSG pipe.
 Do not let children touch or play, because careless operating may
cause the procedure changed.
 When the attached cables of this product and transformer are changed,
they must be changed to the one that is from our factory.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

1. Product Overview

1.1. Main Application & Applicability

Used for intelligent filtering and softening in the water treatment systems.
Be suitable for
Residential softening system
Residential filtration system
Boiler softening water system
RO pretreatment softening system, etc.

1.2. Product Characteristics

 Simple structure and reliable sealing


It adopts hermetic head faces with high-degree pottery and
corrosion resistance for opening and closing. It combines with Service,
Backwash, Brine & Slow Rinse, Brine Refill and Fast Rinse for softener
or Service, Backwash and Fast Rinse for filter.
 No water pass the valve in regeneration in single tank type.
 Manual function
Realize regeneration immediately by pushing manual button at
any time.
 Long outage indicator
If outage overrides 3 days, the time of day indicator “” will flash to
remind the user to reset new time of day. The other set parameters do
not need to reset. The process will continue to work after power on.
 The valve will automatically rotate for more than ten seconds
after it is electrified
After the valve is electrified, it will automatically rotate for more than
ten seconds to turn back to the position when the electricity is cut off.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

 Buttons lock
No operations to buttons on the controller within 1 minute, button
lock indicator light on which represent buttons are locked. Before
operation press and hold the “ ”and“ ” buttons for 5 seconds to
unlock. This function can avoid incorrect operation.
 Interval backwash times (Suitable for F68P/F69P)
It could set up interval backwash times for F68P/F69P up-flow
regeneration valve which means several times of services but one time
of backwash. The setting of interval backwash time depends on the
local water turbidity. (The lower the turbidity is , the longer of the interval
backwash time can be set)
 It can choose time clock type or meter type by program
selection
When all symbols light no, press and hold and buttons for 5
seconds to enter the menu of valve model selection. Please set the
program type in accordance with the product type. (Tim clock type by
days or hours or meter type) (Notice: The meter type product has one
flow meter and flow meter cable, but the time clock type does not have).
 Two meter types can be selected ( Suitable for F63P3, F65P3,
F68P3, F69P3)

Model Name Instruction


Regenerate on the day although the available volume
Meter
A-01 of treated water drops to zero (0). Regeneration starts
Delayed
at the regeneration time.
Meter Regenerate immediately when the available volume of
A-02
Immediate treated water drops to zero(0).
 Interlock function
It has a function of interlock to realize only one valve in regeneration
but the other valves are in service while several valves parallel in system.
In multi-steps treatment systems such as RO pre-treatment, when
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

several valves are in series, there is only one valve in regeneration or


washing to ensure pass water all the times while different valves in
regeneration or washing.(Application refer to Figure 3-9)
 Control Signal Output (F63P as example)
There is a signal output connector on the main control board. It is for
controlling external wiring (Refer to Figure from Figure3-1 to Figure
3-8).
There are two kinds of output modes:
b-01 Mode: Turn on start of regeneration and shut off end of
regeneration; b-02 Mode: Signal available only at intervals of
regeneration cycles and In service.

b-01 b-02

 User can set the maximum interval regeneration days (Only for
F63P3/F65P3/F68P3/F69P3)
In the situation of service reaching the setting days but the volume
not yet, it could enter into regeneration process forcibly when current
time is the same as regeneration time.
 All parameters can be modified
According to the water quality and usage, the parameters in the
process can be adjusted.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

1.3. Service Condition

Runxin Valve should be used under the below conditions:

Items Requirement
Working Water pressure 0.15MPa~0.6MPa
Conditions Water temperature 5℃~50℃
Environment
5℃~50℃
temperature
Working
≤95% ( When temperature is
Environment Relative humidity
25℃)
Electrical facility AC100~240V/50~60Hz
Down-flow regeneration<5FTU;
Water turbidity
Up-flow regeneration<2FTU
First Grade Na+<6.5mmol/L;
Inlet Water Water hardness
Second Grade Na+<10mmol/L
Quality Free chlorine <0.1mg/L
Iron2+ <0.3mg/L
CODMn <2mg/L(O2)
Inlet Water
Turbidity <20FTU
Filter

In the above table, First Grade Na+ represents First Grade Na+
Exchanger. Second Grade Na+ represents Second Grade Na+
Exchanger.
 When the water turbidity exceeds the conditions, a filter should be
installed on the inlet of control valve.
 When the water hardness is more than the conditions allow, the outlet
water hardness will hardly reach the requirement of boiler feed water
(0.03 mmol/L). It is suggested to adopt second grade softener.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

1.4. Product Structure and Technical Parameters

The appearance is just for reference. It is subject to the real product.


A.F63P1/F63P3/F68P1/F68P3

进水口 Inlet 出水口 Outlet 吸盐口 Brine Line Connector 排水口 Drain
基座 Base 中心管 Riser Piper

Flow Rate Regenerati


A(mm) B(mm) H(mm)
Model m3/h on
max max max
@0.3MPa Mode
F63P1/F63P3 282 198 177 4.0 Down-flow
F68P1/F68P3 282 198 176.5 4.0 Up-flow
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

B. F65P1/F65P3/F69P1/F69P3

Water
H(mm Regeneratio
Product A(mm) B(mm) Treatment
) n
Model max max Capacity
max Type
m3/h @0.3MPa
F65P1/F65 187.3 187.8 142.8 2.0 Down-flow
P3
F69P1/F69 196.4 187.8 152.8 2.0 Up-flow
P3
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

C. F71P1

D. F67P1

Notice: OD-Diameter
Control Valve Transformer Output: DC12V, 1.5A.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

1.5. Installation

A. Installation notice
Before installation, read all those instructions completely. Then
obtain all materials and tools needed for installation.
The installation of product, pipes and circuits should be
accomplished by professional to ensure that the product can operate
normally.
Perform installation according to relevant pipeline regulations and
the specifications of Water Inlet, Water Outlet, Drain Outlet, Brine Line
Connector.
B. Device location
①The filter or softener should be located as close as to the drain.
②Ensure the device is installed in enough space for operating and
maintenance.
③Brine tank needs to be close to softener.
④The device should be kept off the heater, and not be exposed outdoor.
Sunshine or rain will cause damage to the system.
⑤Please avoid to install the system in one Acid/Alkaline, Magnetic or
strong vibration circumstance, because such factors will cause the
system disorder.
⑥Do not install the filter or softener, drain pipeline in circumstance which
temperature may drop below 5℃, or above 50℃.
⑦The system should be installed in a place where there will be the
minimum loss in case of water leakage.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

C. Pipeline installation (F63P3 as example)


① Install control valve
a. As the Figure 1-1 shows, select the riser pipe with 26.7mm OD, glue
the riser pipe to the bottom strainer and put it into the resin tank, cut off
the exceeding tube out of tank top opening and make the tube exterior
rounded.
b. Fill a stipulated amount of resin to the tank.
c. Screw the top strainer into the control valve.
d. Insert the riser tube into control valve and screw tight control valve.
Notice:
● The length of riser tube should be neither higher 2mm nor 5mm lower
than the tank top opening, and its top end should be rounded to avoid
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

damage of O-ring inside the valve.

● Avoid floccules substance together with resin to fill in the mineral tank.
● Avoid O-ring inside control valve falling out while rotating it on the tank.
② Install animated connector
As Figure1-2 shows, put the sealing ring into nut of animated
connector, and screw in water inlet.
③ Install flow meter
As Figure1-2 shows, put the seal ring into nut of flow meter, screw in
water outlet; insert the sensor into flow meter.
④ Pipeline connection
a. As Figure1-3 shows, install a pressure gauge in water inlet.
b. Install valve A, B, C and D in the intermediate pipeline, inlet and outlet
valve D is a sampling valve. (Or adopt F70A/F70C bypass valve).
[Link] pipeline should be in parallel with outlet pipeline. Support inlet and
outlet pipeline with fixed holder.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Note:
●If the water outlet or water tank is installed higher than control valve or
parallel interlock system with multi-outlets, a liquid level controller must
be installed in brine tank. Or else, the water in water outlet or water
tank will flow backwards into brine tank when backwash.
●If making a soldered copper installation, do all sweat soldering before
connecting pipes to the valve. Torch heat will damage plastic parts.
●When turning threaded pipe fittings onto plastic fitting, use care not to
cross thread or broken valve.
●If the valve belongs to time clock type, there are no step ② and ③
⑤ Install drain pipeline
[Link] the Figure 1-4 shows, slide the drain hose connector into drain
outlet.
[Link] drain line flow control into drain outlet
[Link] drain hose connector into drain outlet, and lock it.
[Link] the drain hose well as the Figure1-4 show.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Note:
● Be sure not to connect drain with sewer, and leave a certain space
between them, avoid wastewater be absorbed to the water treatment
equipment, such as showed in the Figure1-4.

⑥ Connect brine tube


[Link] Figure1-5 shows, slide 3/8″brine tube hose connector over end of
brine tube.
[Link] tube bushing into the end of brine tube.
[Link] the red brine line flow control into valve brine line
connector(Attention: cone side of control should face into valve)
[Link] brine draw hose connector onto brine line connector.
[Link] the other end of brine tube with the brine tank. ( The liquid
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

level controller and air-blocker should be installed in the brine tank.)


Notice: The brine tube and drain pipeline should not be bended or
plugged.

2. Basic Setting & Usage

2.1. The Function of PC Board

四 位 数 码 显 示区 Four Digital Area 反 洗 图 标 Backwash 运 行 图标


Service 正洗图标 Fast Rinse 时钟图标 Time of Day 天图标 Day 立方图
标 CBM 立方/小时图标 Cubic Meter per Hour 分钟图标 Minute 吸盐图标
Brine & Slow Rinse 补 水 图 标 Brine Refill 查 询 与 设 置 图 标
Enquiry/Setting 键锁图标 Button Lock
A.
 Light on,display the time of day.
B.
 Light on, indicate the buttons are locked. At this moment, pressing
any single button will not work (No operation in one minute, will
light on and lock the buttons.)
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

 Unlocking:Press and hold both and for 5 seconds until the


light off.
C.
 Light on,enter program display mode. Use or to view all
values.
 Flash, enter program set mode. Press or to adjust values.
D. Button
 Press , light on, enter program display mode and use or to
view all values.
 In program display mode, press , flash, enter program set mode,
press or and adjust values.
 Press after all program are set, and then the voice “Di” means all
settings are successful and return to program display mode.
E. Button
 Press in any status, it can proceed to next step.(Example: If outlet
water is unqualified, press in Service status, it will start
regeneration cycle instantly; Press while it is in Backwash status,
it will end backwash and go to Brine & Slow Rinse at once.)
 Press in program display mode, and it will return in Service; Press
in program set mode, and it will return program display mode.
 Press while adjusting the value, then it will return to program
display mode directly without saving values.
F. ▼ Button and ▲ Button
 In program display mode, press ▲or▼ to view all values.
 In program set mode, press ▲or▼ to adjust values.
 Press and hold both ▲and ▼for 5 seconds to lift the Button Lock
status.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

2.2. Basic Setting & Usage

A. Parameter specifications
Indicat Factory Parameter
Function Instruction
or Default set range
Rando 00:00~ Set the time of day when use;“:”
Time of Day
m 23:59 flash.
Meter Delayed: Regenerate on
the day although the available
A-01 volume of treated water drops to
zero (0). Regeneration starts at
Control Mode A-01 A-01 the regeneration time.
Meter Immediate: Regenerate
immediately when the available
A-02
volume of treated water drops to
zero(0).
Unit Mode HU-01 HU-01 1, 2 1-m3;2-gal
Only for Time Clock Type,
Service Days 1-03D 0~99 Days
regeneration by days.
Regeneration 00:00~
02:00 02:00 Regeneration time;“:” light on.
Time 23:59
Interval For example, F-01 indicate
Backwash F-00 00 0~20 service 2 times, backwash 1
Times time.(Only for F68P, F69P)
For example, F-01 indicate rinse
Rinsing
F-00 00 0~20 2 times, service 1 time.(Only for
Frequence
F67P, F71P)
Water Treatment 0~99.99 Water treatment capacity in one
10m3
Capacity m3 circle (m3)
Backwash time(Minute)
Backwash 10min. 0~99
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Brine & Slow


Rinse Time 60min. 0~99 Brine & Slow rinse time(Minute)

Brine Refill
5min. 0~99 Brine refill time(Minute)
Time
Fast Rinse Fast rinse time(Minute)
10min. 0~99
Time
Maximum Regenerate on the day even
Interval through the available volume of
H-30 30 0~40
Regeneration treated water do not drop to zero
Days (0).
Output Mode 01: Signal turn on start of
Control Mode regeneration and shut off end of
regeneration. (Connection refer
b-01 01 01 or 02 to the Figure P3)
Mode 02: Signal available only
intervals of regeneration cycles
and in service. (Connection refer
to the Figure P4)

B. Process Display

Figure A Figure B Figure C Figure D

Figure E Figure F Figure G Figure H


EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Illustration:
 In Service status, the figure shows A/B/C/D; In Backwash status, it
shows figure E/C; In Brine& Slow Rinse status, it shows F/C; In Brine
Refill status, it shows figure G/C; In Fast Rinse status, it shows figure
H/C. In each status, every figure shows 15 seconds.
 The above displays take the Meter Type for example. For the Time
Clock Type, it shows the rest days or hours, such as 1-03D.
 The display screen will only show “-00-” when the electrical motor is
running.
 The time of day figure“” flash continuously, such as “12:12” flash,
indicates long outage of power. It reminds resetting the time of day.
 When the system malfunctions, the display will show error code, such
as “-E1-”.
 F63P/F65P/F68P/69P working process: Service→ Backwash→ Brine
& Slow Rinse→ Brine Refill→ Fast Rinse.
 F67P/F71P working process: Service→ Backwash→ Fast Rinse.

C. Usage

After the accomplishment of installation, parameter setting and trial


running by the professional, the valve can be put into use. In order to
ensure that the quality of outlet water can reach the requirements, the
user should complete the below work:
① Ensure that there is solid salt all the time in the brine tank in the
course of use when this valve is used for softening. Only clean softening
salt can be added to the brine tank, at least 99.5% pure. It is forbidden to
use fine salt and iodized salt.
② Test the outlet water and raw water hardness on a regular basis.
When the outlet water hardness is unqualified, please press the and
the valve will temporarily regenerate again( It will not affect the original
set operation cycle)
③ When the feed water hardness changes a lot, you can adjust the
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

water treatment capacity as below:


Press and hold both and for 5 seconds to lift the lock status.
Press , and the light on, then press to choose the water
treatment capacity. The digital area will show the given water treatment
capacity, such as 10.00m3. Press again, the water treatment capacity
“10.00” flash, then press to reset the value. Press twice and
hear a sound “Di”, then finish the adjustment. Press exit and turn
back to the service status.
④ For A-01 control mode (Delayed regeneration type), please pay
attention whether the time is current or not. If the time is not right, you
can adjust as below: After lifting the lock status, press , the and
light on. Then press , the and hour value flash. Press or
continuously to reset the hour value; Press again, and minute
value flash. Press or continuously, reset the minute value;
Press and hear a sound “Di”, then finish the adjustment. Press
exit and turn back to the service status.
The regeneration parameters have been set when control valve left
the factory. Generally, it does not need resetting. If you want to inquire
and modify the settings, you can refer to the professional application
specifications.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

3. Applications
3.1. Softener Flow Chart

B. Filter Flow Chart


EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

3.2. The Function and Connection of PC Board

Opening the front cover of control valve, you will see the main control
board and connection port as below:

DC12V 接口 DC12V Connector 电机接口 Motor Connector 信号输出接


线座 Signal Output Connector 流量计接口 Flow Meter Connector 互锁接
口 Interlock Connector 定位板接口 Locating Board Connector
The main functions on main control board:
Function Application Explanation
If system strictly requires no hard water to
Outlet solenoid
flow from outlet or controlling the liquid level
valve
Signal output in water tank.
connector Increase pressure for regeneration or
b-01 washing.
Inlet pump
Use the liquid level controller to control inlet
pump to ensure there is water in tank.

Signal output Inlet solenoid When inlet pressure is high, it needs to close
connector valve or inlet water inlet when valve is rotating to protect
b-02 pump motor.

To ensure only
Use in RO Pre-treatment, water supply
one control valve
Interlock together but regeneration in turn. Second
in regeneration or
connector grade ion exchange equipment, etc.
washing in
system.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

A. Signal Output Connector


1) Control Solenoid Valve(Set as b-01)
①Solenoid Valve on Outlet Controls Water Level in Brine Tank.
Instruction: If system strictly require no hard water to flow from outlet in
regeneration cycle( Mainly for no hard water flow out when valve is
switching or valve in backwash or brine drawing positions), a solenoid
valve could be installed on outlet, the wiring refer to Figure 3-1.

Function:
When valve in service status, if soft water tank is short of water,
solenoid valve is open to supply soft water, but if water tank has enough
water, solenoid valve is closed, so no soft water will be supplied.
When the valve in backwash status, there is no signal output. So,
solenoid valve is closed, and now water flows into soft water tank.
②Solenoid Valve on Inlet( Set as b-02)
Instruction: When inlet pressure exceeds 0.6MPa, install a solenoid
valve on inlet. Control mode is b-02. Pressure will be relieved when
valve is switching, the wiring refer to Figure 3-2. As Figure 3-3 shows, it
also can use the pressure relief port to work.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Function:
When inlet pressure is high, install a solenoid valve on inlet to
ensure valve switching properly. When valve is exactly in position of
Service, Backwash, Brine& Slow Rinse, Brine Refill and Fast Rinse,
solenoid valve is open. When valve is switching, solenoid valve is closed,
no water flow into valve to ensure valve switching properly. It could
prevent the problem of mix water and water hammer.
Use interlock cable to realize valves in parallel and series in same
system which is suited for RO pretreatment system or second grade Na+
system. The Wiring refers to Figure 3-4:

2) Liquid Level Controller controls Inlet Pump( Two-phase motor)( Set


as b-01)
Instruction: For the system using well or middle-tank supplying water,
switch of liquid level controller and valve together control pump opening or
closing. The wiring refer to Figure 3-5:
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Function:
When valve in service status, if water tank is short of water, start up
pump, but if water tank has enough water, the switch of liquid level
controller is closed, so pump does not work.
When valve in regeneration cycle, inlet always has water no matter
what is water condition in water tank. As Runxin valve no water pass
outlet in regeneration cycle, it ensures no water fill into brine tank.
A liquid switch at the top opening O well or in middle water tank in
RO system protect pump from working without water in case of out of
raw water.

3) Liquid Level Switch in Water Tank Controls Inlet pump (Three-phase)


(Set as b-01)
The principle is the same as for two-phase's, only change
single-phase into three-phase motor, and use an AC contactor ( Refer to
Figure 3-6)
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

4) Control Inlet Booster Pump( Set as b-01 or as b-02)


Instruction: If inlet water pressure is less than 0.15MPa, which makes
rinse drawing difficult, a booster pump is suggested to be installed on
inlet. Set Control mode as b-01. When system in regeneration cycle,
booster pump is open, the wiring refer to Figure 3-7. If the booster pump
current is bigger than 5A, system need to install a contactor, the wiring
refer to Figure3-8

交流水泵 AC Pump 交流接触器 AC Contactor


EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

B. Interlock

Instruction:
In the parallel water treatment system, it ensures only one valve in
regeneration or washing cycle and (n-1) valves in service, that is,
realizing the function of supplying water simultaneously and
regenerating individually, the wiring refer to Figure3-9.
In the series and parallel water treatment system(Second grade Na+
Exchanger or RO pre-treatment system), it ensure only one valve in
regeneration or washing cycle and there is/are water(s) in service.

互锁线 Interlock Cable 互锁线插头。。。一直相连接 Plug Cable in Socket of


Same Color
Note: Use Interlock Cable to connect CN8 to CN7 on next valve in the
loop.
One system with several valves, if interlock cable is disconnected,
the system is divided into two individual system.

C. Interlock System

It only needs to connect the 2 or more valve by interlock cable to


realize simultaneous water supply and independent regeneration. The
wiring refer to Figure3-12.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Figure 3-12 Interlock System

3.3. System Configuration and Flow Rate Curve


A. Product Configuration
Product configuration with tank, resin volume, brine tank and injector
Minimum Salt
Resin Flow Consumption
Item Tank Size Brine Tank Injector
Volume Rate for
No. (mm) Size (mm) Model
(L) (t/h) Regeneration
(Kg)
1 φ180×1130 16 0.5 φ200×500 2.40 6302
2 φ205×1300 25 0.7 Φ250×520 4.00 6303
3 φ255×1390 40 1.2 Φ250×520 6.00 6305
4 φ300×1650 60 1.8 φ400×800 9.00 6306
5 φ355×1650 100 2.5 Φ450×940 15.00 6308
6 φ400×1650 120 3.5 Φ450×940 18.00 6309
7 φ450×1650 150 4.5 φ500×1060 22.50 6310
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Attention: The tank size and brine tank configuration should comply with
the technical requirements of softener valves.

Item 4 should be selected for the softener valve of 2m3/h water treatment
capacity.

B. Flow Rate characteristic


1) Pressure-flow rate curve
F63P1/F63P3/F68P1/F68P3

F65P1/F65P3/F69P1/F69P1

Flow Rate
压差 Pressure Drop 反洗流速 Backwash flow rate 运行流速 Service flow
rate
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Remark: The above data for the product configuration and relevant
characteristics are only for reference. When put in practice, it is subject
to the different requirements of raw water hardness and application.

Item 6 should be selected for the softener valve of 2m3/h water treatment
capacity.

3.4. Parameter settlement

①Service timeT1
Water treatment capacity:
Q=VR×K÷YD(m3)
Hardness of Inlet Water (mmol/L)
Exchange factor (mmol/L) 400 ~
1000. Down-flow regeneration, take
400 ~ 750. Up-flow regeneration,
take 450~1000. If the inlet water
hardness is higher, the factor is
smaller.
Resin volume( m3)
By hours: T1=Q÷Qh(Hour)
3
Water treatment capacity per hour (m /h)
Water treatment capacity(m3)
By days:T1=Q÷Qd(Day )
3
Water treatment capacity per day (m /d)
Water treatment capacity (m3)
②Backwash time T2
It is subject to the turbidity of inlet water. Generally, It is suggested
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

to be set 10 ~ 15 minutes. The higher the turbidity is, the longer


backwash time can be set. However, if the turbidity is more than 5FTU, it
should be better to install a filter in front of the exchanger.
③Brine & slow rinse time T3
T3=(40~50)×HR(min.)
Generally, T3=45HR(min.)
In this formula, HR——The height of resin in exchange tank (m.)
④Brine refill timeT4
Down-flow regeneration:T4=0.45×VR÷Brine refill speed (min.)
Up-flow regeneration:T4=0.34×VR÷Brine refill speed (min.)
In this formula, VR—— Resin volume (m3)
The Brine refill speed is related to inlet water pressure. It is
suggested to lengthen 1~2 minutes of calculated brine refilling time to
make sure there is enough water in tank. (The condition is that the there
is a level controller installed in the brine tank)
⑤Fast rinse time T5
T5=12×HR(min.)
Generally, the water for fast rinse is 3~6 times of resin volume. It is
suggested to be set 10~16 minutes, but subject to the outlet water
reaching the requirement.
⑥Exchange factor
Exchange factor =E/ (k×1000)
In this formula, E——Resin working exchange capability(mol/m3) ,
it is related to the quality of resin. Down-flow regeneration, take 800~
900. Up-flow regeneration, take 900~1200.
K——Security factor, always take 1.2 ~ 2. it is related to the
hardness of inlet water: the higher the hardness is, the bigger the K
is.
⑦Set up interval backwash times(Only for F68 P/F69P)
When the turbidity of raw water is higher, the interval backwash time
could be set F-00. That is, backwash in each regeneration; when the
turbidity is lower, the interval backwash time could be set F-01(or other
number value), it is to say that backwash in every two regeneration.
Thus, Service→Brine& slow rinse→Brine refill→ Fast rinse→ Service→
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Backwash →Brine& slow rinse →Brine refill →Fast rinse.


⑧Regeneration time
The whole cycle for generation needs approximately two hours.
According to the actual situation, please try to set up the regeneration
time in the period when you don’t need to use water.
The calculation of parameters for each step is only for reference, the
actual proper time will be determined after adjusting by water exchanger
supplier. This calculation procedure of softener is only for industrial
application; it is not suitable for small softener in residential application.

3.5. Parameter Enquiry and Setting

3.5.1. Parameter Enquiry


When light on, press and hold both and for 5 seconds to
lift the button lock status; then press and light on, enter the
program display mode; press or to view each value according to
below process.(Press exit and turn back to service status)
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

当前时间 The Time of Day 再生时间 Regeneration Time 运行天数


Service Days 反洗时间 Backwash Time 吸盐时间 Brine Draw Time
补水时间 Brine Refill Time 正洗时间 Fast Rinse Time 信号输出方式
Signal Output Control Mode
冲洗增加次数 Backwash Frequence
反洗间隔次数 Interval Backwash Times
水量单位 Unit 最大再生天数 Maximum Interval Regeneration Days
工作模式 Work Mode

3.5.2. Parameter Setting


In program display mode, press and enter the program set mode.
Press or to adjust the value.

3.5.3. The steps of parameter setting (Take F63P3 A-01 as an


example)
Items Process steps Symbol
When time of day “12:12” continuously flash, it
reminds to reset;
1. Press to enter into program display mode;
both and symbol light on,“:”flash; Press
, both and hour value flash, through
Time of Day
or to adjust the hour value;
2. Press again, both and hour value flash,
through or to adjust the minute value;3
3. Press and finish the adjustment, press
to turn back.
[Link] unit mode display status, press and
enter into program set mode, and 1value flash;
[Link] or ,and choose from the m3/gal;
Unit Mode
3. Press and finish adjustment, press to
turn back.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

1. In regeneration time display status, press


and enter into program set mode. and 02
flash;
Regeneratio 2. Press or to adjust the hour value;
n Time 3. Press again, and 00 flash, press or
to adjust the minute value;
Press and hear a sound “Di”, then finish
adjustment, press to turn back.
1. In control mode display status, press and
enter into program set mode, and 01 value
Control flash;
Mode 2. Press or ,set the value as A-01 or A-02,
3. Press and then finish adjustment, press
to turn back.
1. In water treatment capacity display status, it
shows and 10.00. Press and enter into
Water program set mode. and 10.00 flash
Treatment 2. Press or to adjust the water treatment
Capacity capacity value(m3)

3. Press and finish the adjustment, press
to turn back.
1. In backwash time display status, it shows
and 2-10. Press and enter into program set
Backwash mode. and 10 flash;
Time 2. Press or to adjust the backwash time;
3. Press and finish the adjustment, press
to turn back.
1. In brine& slow rinse time display status, it
shows and 3-60. Press and enter into
Brine & Slow
program set mode. and 60 flash;
Rinse Time
2. Press or to adjust the brine &slow rinse
time;.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

3. Press and hear a sound “Di”, then finish


adjustment, press to turn back.

1. In brine refill time display status, it shows


and 4-05. Press and enter into program set
Brine Refill mode. and 05 flash;
Time 2. Press or to modify the brine refill time;
3. Press and finish the adjustment, press
to turn back.
1. In fast rinse time display status, it shows and
5-10. Press and enter into program set
mode. and 10 flash;
Fast Rinse
2. Press or to adjust the fast rinse
Time
time(minute);
3. Press and finish the adjustment, press
to turn back.
1. In maximum Interval regeneration days display
status, it shows H-30. Press and enter into
Maximum
program set mode. and 30 flash;
Interval
2. Press or to adjust the Interval
Regenerati
regeneration days;
on Days
3. Press and finish the adjustment, press
to turn back.
1. In signal output mode display status, it shows
b-01. Press and enter into program set
Signal mode. and 01flash;
Output Mode 2. Press or to adjust the b-02;
3. Press and finish the adjustment, press
to turn back.

For example,the fast rinse time of a softener is 12 minutes. After


regenerating, the chloridion in the outlet water is always higher than
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

normal, indicating that there is not enough time for fast rinse. If you
want the time to set to 15 minutes, the modification steps as follows:
① Press and hold both and to lift the button lock status(
light off);
② Press ,and light on;
③ Press or continuously until light on. Then the digital
area shows: 5-12M;
④ Press , and 12 flash;
⑤ Press continuously until 12 changes to 15;
⑥ Press , there is a sound “Di” and the figure stop flashing;
the program back to enquiry status
⑦ If you want to adjust other parameters, you can repeat the
steps from ②to ⑤; If you don’t, press and quit from the enquiry stat,
the display will show the current service status.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

3.6. Trial running


After installing the multi-functional flow control valve on the resin
tank with the connected pipes, as well as setting up the relevant
parameters, please conduct the trial running as follows:
A. Close the inlet valve B & C, and open the by-pass valve A. After
cleaning the foreign materials in the pipe, close the by-pass valve A. (as
Figure [Link])
B. Fill the brine tank with the planned amount of water and adjust the air
check valve. Then add solid salt to the tank and dissolve the salt as
much as possible.
C. Switch on power. Press and go to the Backwash position; when
light on, slowly open the inlet valve B to 1/4 position, making the
water flow into the resin tank; you can hear the sound of air-out from the
drain pipeline. After all air is out of pipeline, then open inlet valve B
completely and clean the foreign materials in the resin tank until the
outlet water is clean. It will take 8~10 minutes to finish the whole
process.
D. Press , turning the position from Backwash to Brine& Slow Rinse;
light on and enter in the process of Brine& Slow Rinse. The air check
valve close when control valve finished sucking brine, then slow rinse
start to work. It is about 60~65minutes for whole process.
E. Press to Brine refill position. light on and it indicates the brine
tank is being refilled with water to the required level. It takes about 5~
6minutes, then add solid salt to the brine tank.
F. Press , turning to Fast Rinse position. light on and start to fast
rinse. After 10~15minutes, take our some outlet water for testing: if the
water hardness reach the requirement, and the chloridion in the water is
almost the same compared with the inlet water, then go to the next step.
G. Press , making the control valve return to Service Status; light
on and start to run.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Note:
 If water inflow is too fast, the media in tank will be damaged. When
water inflow slowly, there is a sound of air emptying from drain pipeline.
 After changing the resin, please empty air in the resin according to the
above Step 2.
 In the process of trial running, please check the water situation in all
position, ensuring there are no resin leakage.
 The time for Backwash, Brine& Slow Rinse, Brine Refill and Fast Rinse
position can be set and executed according to the calculation in the
formula or suggestions from the control valve suppliers.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

3.7. Trouble-Shooting

A. Control Valve Fault

Problem Cause Correction


A. Assure permanent electrical
A. Interruption of electricity
service(Check fuse, plug, pull
B. Regeneration cycles set
[Link] fails chain or switch).
incorrect.
to regenerate. B. Reset regeneration cycles.
C. Controller is defective.
C. Replace controller.
D. Motor fails to work.
D. Replace motor.
A. Time of Day is not set
2. Incorrect Check program and reset time of
correctly.
Regeneration day.
B. Power failure more than
Time
3 days.
A. Close or repair bypass valve.
A. Bypass valve is open or B. Add salt to brine tank and
leaking. maintain salt level above water
B. No salt in brine tank. level.
C. Injector plugged. C. Change or clean injector.
D. Insufficient water D. Check brine tank refill time.
flowing into brine tank. E. Make sure riser pipe is not
[Link]
E. Leak at O-ring on riser cracked. Check o-ring and tube
supply hard
pipe. pilot.
water.
F. Internal valve leak. F. Change valve body.
G. Regeneration cycles not G. Set correct regeneration cycles
correct. in the program.
H. Shortage of resin. H. Add resin to mineral tank and
I. Bad quality of feed water check whether resin leaks.
or turbine blocked. I. Reduce the inlet turbidity, clean
or replace turbine.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

A. Line pressure is too low. A. Increase line pressure.


B. Brine line is plugged. B. Clean brine line.
C. Brine line is leaking. C. Replace brine line.
D. Injector is plugged. D. Clean or replace new parts.
[Link] fails
E. Internal control leak. E. Replace valve body.
to draw brine.
F. Drain line is plugged. F. Clean drain line flow control.
G. Sizes of injector and G. Select correct injector size and
DLFC does not match with DLFC according to the P20
tank. requirements.
A. Improper salt setting. A. Check salt usage and salt
[Link] uses
B. Excessive water in setting.
too much salt.
brine tank. B. See problem no.6.
A. Overlong refilling time.
B. Foreign material in brine A. Reset correct refilling time.
line. B. Clean brine line.
C. Foreign material in C. Clean brine valve and brine
[Link] brine valve and plug drain line.
water in brine line flow control. D. Stop water supplying and
tank. D. Not install safety brine restart pr install safety brine valve
valve but power failure in salt tank.
whiling salting. E. Repair or replace safety brine
E. Safety brine valve valve.
breakdown.
A. Clean the water supply pipe.
B. Clean valve and add resin
A. Iron in the water supply cleaning chemical, increase
pipe. frequency of regeneration.
[Link] lost
B. Iron mass in the C. Check backwash, brine draw
or iron in
softener. and brine tank refill. Increase
conditioned
C. Fouled resin bed. frequency of regeneration and
water.
D. Too much iron in the backwash time.
raw water. D. Iron removal equipment is
required to install before
softening.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

A. Air in water system. A. Assure that well system has


[Link] of resin
B. Bottom strainer broken. proper air eliminator control.
through drain
C. Improperly sized drain B. Replace the bottom strainer.
line.
line control. C. Check for proper drain rate.
A. Controller is faulty.
[Link] cycle B. Some parameter is set A. Replace the controller.
continuously. as 0 in program. B. Check and reset the program.

A. Check and repair valve body or


A. Internal valve leak.
replace it.
B. When electricity fails to
B. Adjust valve to service position
supply, valve stops
or turn off bypass valve and
[Link] flows backwash or fast rinse
restart when electricity supply.
continuously. position.
C. When F63, F65, F68, F69
C. Control valve is in
control valve is in Backwash
Backwash status.
status, the outlet is connected
with drain port.
A. Foreign material in
injector pr injector fails to
work. A. Clean and repair injector.
[Link] water in
B. Brine valve cannot be B. Repair brine valve and clean it.
soften water.
shut-off. C. Extend rapid rinse time.
C. Time of rapid rinse too
short.
A. Water pressure too low
A. Increase water pressure.
or not stable.
B. Clean or replace injector.
[Link] B. Injector is plugged or
C. Check and find the reason.
or irregular faulty.
D. Clean the floccules in resin
brine. C. Air in resin tank.
tank.
D. Floccules in resin tank
during backwash.
[Link] flow A. Foreign material in A. Clean foreign material in valve
out from drain valve which makes valve body.
or brine pipe can’t be closed B. Change valve core or sealing
after completely. ring.
regeneration. B. Hard water mixed in C. Reduce water pressure or use
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

valve body. pressure release function.


C. Water pressure is too
high which result in valve
doesn’t get the right
position.
A. Regenerate according to the
A. Unit fails to regenerate correct operation requirement.
or regenerate not properly. B. Increase backwash flow rate
B. Fouled resin bed. and time, clean or change resin.
C. Salt setting not proper. C. Readjust brine drawing time.
[Link] water D. Softener setting not D. According to the test of outlet
treat capacity proper. water, recount and reset.
decreases. E. Raw water quality E. Regenerate unit by
deterioration. manual temporary, then
F. Turbine of flow meter is reset regeneration cycle.
stuck. F. Disassemble flow meter and
clean it or replace it with a new
turbine.

B. Controller Fault
Problem Cause Correction

A. Control board is faulty.


A. Replace control board.
1. All indictors B. Transformer dampened
B. Check and replace transformer.
display on or damaged.
[Link] and adjust electrical
front panel. C. Electrical service not
service.
stable.
A. Wiring of front panel with
A. Check and replace wiring.
controller fails to work.
2. No display B. Replace front panel.
B. Control board damaged.
on front panel. C. Replace transformer.
C. Transformer damaged
D. Check electricity supply.
D. Electricity is interrupted.
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

A. Wiring of locating board


with controller fails to work.
B. Locating board A. Replace wiring.
damaged. B. Replace locating board.
C. Mechanical drive C. Check and repair mechanical
failure. part.
3. E1 Flash
D. Faulty control board. D. Replace control board.
E. Wiring of motor with E. Replace wiring.
controller is fault. F. Replace motor.
F. Motor damaged. [Link] the system to reset it.
G. The set mode does not
match with the valve body.
4. E3 or E4
A. Control board is faulty. A. Replace control board.
Flash
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

3.8. Assembly & Parts

Flow Meter Connector & Animated Connector

5447001 Flow Meter 5457002 Animated Connector

5447001 Flow Meter 5457002 Animated Connector

Item Item
Description Part No. Quantity Description Part No. Quantity
No. No.

1 Animated nut 8945001 1 1 Animated nut 8945001 1

2 O-ring 28X2.65 8378081 1 2 Ferrule 8270002 1

3 Clip 8270001 1 3 Clip 8270001 1

4 Ferrule 8270002 1 4 O-ring 28X2.65 8378081 1

Impeller
5 5115001 1 5 Connector 8458038 1
supporter

6 Impeller 5436001 1

7 Rotating core 8211001 1

8 Bushing 8210001 1

Spring Check
9 8945005 1
Ring

10 Shell 8002001 1
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

F63P3 and F68P3 Exploited Drawing


EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

F63P1/F63P3 Component Name and Codes (Item No. 19, 33 34 only for F63P3)
Item Quan Item Quantit
Description Part No. Description Part No.
No. tity No. y
1 O-ring 73×5.3 8378143 1 25 O-ring 73X3.55 8378128 2
2 O-ring 25.8×2.65 8378078 1 26 O-ring 37.7X3.55 8378118 2
Anti-friction
5022033 27 8216004 1
3 Valve Body 1 Washer
5022034 28 Shaft 8258004 1
Screw, Cross Moving Seal
4 8902016 4 29 8370001 1
ST3.9X16 Ring
Screw, Cross
5 8909009 4 30 Moving Disk 8459001 1
M4X30
6 Gear Motor 6158011 1 31 Fixed Disk 8469001 1
Small Gear,
7 8241003 1 32 Seal Ring 8370002 1
Motor
Animated
8 Pin 8993001 1 33 5457002 1
Connector
9 Power Cable 5513001 1 34 Flow Meter 5447001 1
10 Label 8865057 1 35 Seal Ring 8371001 1
11 Front Cover 8300038 1 36 Plug 8323002 1
12 Control Board 6382056 1 37 Seal Ring 8370003 1
Wire for Locating
13 5511017 1 38 Hexagonal Nut 8940001 1
Board
Screw,Cross,
14 8909004 5 39 Tube 8457004 1
ST2.2X6.5
Brine Line Flow
15 Wire Clip 8126004 2 40 8468002 1
Control
Wire-pressing
16 8005044 1 41 Joint 8458017 1
Plate
Drain Line Flow
17 Dustproof Cover 8005006 1 42 8468007 1
Control
Screw,Cross, Screw,Cross
18 8909010 4 43 8902017 2
ST2.9X16 M5X35
19 Probe Cable 6386001 1 44 Injector Injector 8315001 1
Screw,Cross,
20 8909013 1 45 O-ring 30X1.8 8378025 1
ST3.9X13
21 Big Gear, Driven 8241033 1 46 Nozzle, Injector 8454009 1
22 Locating Board 6380032 1 47 Throat, Injector 8467009 1
Screw,Cross,
23 8909008 4 48 Injector Body 8008001 1
ST2.9X9.5
O-ring
24 Fitting Nut 8092004 1 49 8378012 1
10.82X1.78
50 O-ring 7.5X1.8 8378016 2
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

F68P1/F68P3 Component Name and Codes (Item No. 19, 33, 34 only for F68P3)
Item Quan Item Quantit
Description Part No. Description Part No.
No. tity No. y
1 O-ring 73×5.3 8378143 1 25 O-ring 73X3.55 8378128 2
2 O-ring25.8×2.65 8378078 1 26 O-ring 37.7X3.55 8378118 2
Valve Anti-friction
5022022 27 8216004 1
Body(ABS+GF10) Washer
3 1
Valve
5022023 28 Shaft 8258004 1
Body(PPO+GF20)
Screw,Cross, Moving Seal
4 8909016 4 29 8370001 1
ST3.9X16 Ring
Screw, Cross
5 8902009 4 30 Moving Disk 8459015 1
M4X30
6 Motor 6158011 1 31 Fixed Disk 8469014 1
7 Small Gear, Motor 8241003 1 32 Seal Ring 8370029 1
Animated
8 Pin 8993001 1 33 5457002 1
Connector
9 Power Cable 5513001 1 34 Flow Meter 5447001 1
10 Label 8865057 1 35 Seal Ring 8371001 1
11 Front Cover 8300038 1 36 Plug 8323002 1
12 Control Board 6382056 1 37 Seal Ring 8370003 1
Wire for Locating
13 5511017 1 38 Hexagonal Nut 8940001 1
Board
Screw,Cross,
14 8909004 5 39 Tube 8457004 1
ST2.2X6.5
Brine Line Flow
15 Wire Clip 8126004 2 40 8468002 1
Control
16 Wire-pressing Plate 8005044 1 41 Joint 8458017 1
Drain Line Flow
17 Dustproof Cover 8005006 1 42 8468007 1
Control
Screw,Cross, Screw, Cross
18 8909010 4 43 8902017 2
ST2.9X16 M5X35
19 Probe Cable 6386001 1 44 Injector Cover 8315001 1
Screw,Cross,
20 8909013 1 45 O-ring 30X1.8 8378025 1
ST3.9X13
21 Big Gear 8241035 1 46 Injector Nozzle 8454009 1
22 Locating Board 6380032 1 47 Injector Throat 8467009 1
23 Screw,Cross 8909008 4 48 Injector Body 8008001 1
O-ring
24 Fitting Nut 8092004 1 49 8378012 1
10.82X1.78
25 Locating Board 8380006 1 50 O-ring 7.5X1.8 8378016 2
26 Fitting Nut 8092004 1
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

F65P3 and F69P3 Exploited Drawing


EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

F65P3/F65P1 Component Name and Codes (Item No.20, 33, 39 only for F65P1)
Item Item
Description Part No. Quantity Description Part No. Quantity
No. No.
Moving Seal
1 O-ring73X5.3 8378143 1 29 8370053 1
Ring
2 O-ring 25.8X2.65 8378078 1 30 Moving Disc 8459013 1
Valve Body
5022018
(ABS+GF10)
3 1 31 Fixed Disc 8469012 1
Valve Body
5022019
(PPO+GF20)
Screw, Cross
4 8902008 4 32 Seal Ring 8370025 1
M4X25
Hexagonal Screw,
Animated
5 Cross, Flange 8909016 4 33 5757003 1
Connector
Head, ST3.9X16
6 Seal Ring 8371019 3 34 Plug 8323002 1
7 Plug 8323005 1 35 Flow Meter 5447002 1
8 Gear Motor 6158006 1 36 Seal Ring 830003 1
Brine Line Flow
9 Small Gear 8241010 1 37 8468002 2
Control
10 Pin 8993001 1 38 Tube 8457004 1
11 Label 8865057 1 39 Hexagonal Nut 8940001 1
12 Front Panel 8300039 1 40 Joint 8458017 1
Drain Line Flow
13 Control Board 6382056 1 41 8468007 1
Control
Screw, Cross
14 Screw, Cross 8909004 5 42 8902017 2
M5X35
Wire for Locating
15 5511017 1 43 Injector Cover 8315001 1
Board
Wire-pressing
16 8005044 1 44 O-ring 30X1.8 8378025 1
Plate
17 Dustproof Cover 8005005 1 45 Injector Nozzle 8454009 1
18 Wire Clip 8126004 2 46 Injector Throat 8467009 1
19 Power Cable 5513001 1 47 Injector Body 8008001 1
O-ring
20 Probe Cable 6386001 1 48 8378012 1
10.82X1.78
21 Screw, Cross 8909013 1 49 O-ring 7.5X1.8 8378016 2
22 Big Gear 8241036 1
23 Screw, Cross 8909008 1
24 Locating Board 6380033 1
25 Fitting Nut 8092007 2
26 O-ring 50.39X3.53 8378107 1
Anti-friction
27 8216010 1
Washer
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

F69P3/F69P1 Component Name and Codes (Item No. 20, 33, 35 only for F69P3)
Item Item
Description Part No. Quantity Description Part No. Quantity
No. No.
O-ring
1 O-ring73X5.3 8378143 1 26 8378107 1
50.39X3.53
Anti-friction
2 O-ring 25.8X2.65 8378073 1 27 8216010 1
Washer
Valve Body
5022018
(ABS+GF10)
3 1 28 Shaft 8258009 1
Valve Body
5022019
(PPO+GF20)
Screw, Cross Moving Seal
4 8902008 4 29 8370053 1
M4X25 Ring
Hexagonal
Screw,Cross
5 8909016 4 30 Moving Disc 8459016 1
Flanged Head,
ST3.9X16
Screw, Cross
6 8902005 4 31 Fixed Disc 8469015 1
M4X1
7 Plug 8323005 1 32 Seal Ring 8370034 1
Animated
8 Gear Motor 6158006 1 33 5457003 1
Connector
9 Small Gear 8421010 1 34 Plug 8323002 1
10 Pin 8993001 1 35 Flow Meter 5447002 1
11 Label 8865057 1 36 Seal Ring 8370003 1
Brine Line Flow
12 Front Panel 8300039 1 37 8468002 1
Control
13 Control Board 6382056 1 38 Tube 8457004 1
Screw, Cross
14 8909004 1 39 Hexagonal Nut 8940001 1
ST2.2X6.5
Wire for Locating
15 5511017 1 40 Joint 8458017 1
Board
Wire-pressing Drain Line Flow
16 8005044 1 41 8468007 1
Plate Control
Screw, Cross
17 Dustproof Cover 8005005 2 42 8902017 2
M5X35
18 Wire Clip 8125004 2 43 Injector Cover 8315001 1
19 Power Cable 5513001 1 44 O-ring 30X18 8378025 1
20 Probe Cable 6386001 1 45 Injector Nozzle 8454009 1
Screw, Cross
21 8909013 1 46 Injector Throat 8467009 1
ST3.9X13
22 Gear 8241037 1 47 Injector Body 8008001 1
Screw, Cross O-ring
23 8909008 4 48 8378012 1
ST2.9X9.5 10.82X1.78
24 Locating Board 6380033 1 49 O-ring 7.5X1.8 8378016 1
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

F71P1 Exploited Drawing


EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

Item Item
Description Part No. Quantity Description Part No. Quantity
No. No.
Screw, Cross
1 O-ring 73X5.3 8378143 1 15 8909013 1
ST3.9X13
2 O-ring 25.8X2.65 8378078 1 16 Power Cable 5513001 1
Valve Body
8022048 1 17 Wire Clip 8126004 1
(ABS+GF10)
3
Valve Body
8022049 1 18 Dustproof Cover 8005005 1
(PPO+GF20)
Hexagonal
Screw,Cross Screw, Cross
4 8909016 1 19 8909004 1
Flanged Head ST2.2X6.5
ST3.9X16
Screw, Cross Wire-pressing
5 8909008 1 20 8005044 1
ST2.9X9.5 Plate
Wire for
6 Seal Ring 8370038 1 21 5511017 1
Locating Board
7 Fixed Disc 8469018 1 22 Control Board 6382056 1
8 Moving Disc 8459019 1 23 Front Panel 8300039 1
9 Shaft 8258009 1 24 Label 8865057 1
Anti-friction
10 8216010 1 25 Pin, Φ2.5X12 8993003 1
Washer
11 O-ring 50.39X3.53 8378107 1 26 Small Gear 8241010 1
12 Fitting Nut 8092007 1 27 Gear Motor 6158006 1
Screw, Cross
13 Locating Board 6380033 1 28 Triple Assembly 8902008 1
M4X25
14 Big Gear 8241036 1
EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

F67P1 Exploited Drawing


EURO-CLEAR P SERIES MULTI-FUNCTIONAL FLOW CONTROL VALVE

F67P1(53604P) Component Name and Codes


Item Item
Description Part No. Quantity Description Part No. Quantity
No. No.
Screw, Cross
1 O-ring 73X5.3 8378143 1 16 8909013 1
ST3.9X13
Screw, Cross
2 O-ring 25.8X2.65 8378078 1 17 8909010 4
ST2.9X16
Valve Body
8022039 1 18 Dustproof Cover 8005006 1
(ABS+GF10)
3
Valve Body Screw, Cross
8022040 1 19 8909004 5
(PPO+GF20) ST2.2X6.5
Hexagonal
Screw,Cross Wire-pressing
4 8909016 1 20 8005044 1
Flanged Head Plate
ST3.9X16
Screw, Cross Wire for
5 8909008 1 21 5511017 1
ST2.9X9.5 Locating Board
6 Seal Ring 8370027 1 22 Control Board 6382056 1
7 Fixed Disc 8469013 1 23 Front Panel 6300038 1
8 Moving Disc 8459014 1 24 Label 8865057 1
9 Shaft 8258004 1 25 Wire Clip 8126004 1
Anti-friction
10 8216004 1 26 Power Cable 5513001 1
Washer
11 O-ring 37.7X3.55 8378119 2 27 Pin, Φ2.5X12 8993003 1
12 O-ring 73X3.55 8378128 2 28 Small Gear 8241003 1
13 Fitting Nut 8092004 1 29 Gear Motor 6158021 1
Screw, Cross
14 Locating Board 6382032 1 30 Triple Assembly 8902009 1
M4X30
15 Big Gear 8241034 1

You might also like