100% found this document useful (1 vote)
235 views2 pages

Parshall Flume Flow Meter Specifications

The document describes a 19-tube bundle flow conditioner model DH19-TB. It consists of 19 tubes arranged in a cylindrical pattern to straighten flow. Specifications include the maximum diameter of tubes being between 0.95 and 1 times the pipe diameter, tube length between 2 and 3 times the pipe diameter, wall thickness less than 0.025 times the pipe diameter, and its pressure loss coefficient is approximately 0.75 as calculated by the specified equation.

Uploaded by

Andrzej Bąkała
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
235 views2 pages

Parshall Flume Flow Meter Specifications

The document describes a 19-tube bundle flow conditioner model DH19-TB. It consists of 19 tubes arranged in a cylindrical pattern to straighten flow. Specifications include the maximum diameter of tubes being between 0.95 and 1 times the pipe diameter, tube length between 2 and 3 times the pipe diameter, wall thickness less than 0.025 times the pipe diameter, and its pressure loss coefficient is approximately 0.75 as calculated by the specified equation.

Uploaded by

Andrzej Bąkała
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

PARSHALL FLUME FLOW METER �-1

FLOW
CONDITIONER
Model : DH19-TB

[Link]
FLOW CONDITIONER
Model : DH19-TB
■ DESCRIPTION
The 19-tube bundle flow
straightener (1998) shall
consist of 19 tubes arranged
in a cylindrical pattern as on
a picture.

■ SPECIFICATIONS
- The Maximum outside diameter of the flow straightener Df is 0.95D≤Df≤D
- The length, L, of the tubes shall be between 2D and 3D, preferably as close to 2D as
possible
- The wall thickness shall be less than 0.025D
- The pressure loss coefficient, K, for the 19-tube bundle flow straightener is approximately
equal to 0.75, where K is given by the following equation
△pc is the pressure loss across the 19-tube bundle flow straightener
△pc
K = -------- p is the density of the fluid in the pipe
1/2pV2
V is the mean axial velocity of the fluid in the pipe