TD8620
Handheld Digital TeslaMeter
USER’S MANUAL
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
CONTENT
CONTENT..................................................................................................
1. GENERAL DESCRIPTION...............................................................
2. SPECIFICATIONS..............................................................................
2.1. TD8620-5.......................................................................................
3. INTRODUCTION................................................................................
4. AXIAL AND TRANSVERSE PROBES............................................
5. INITIAL SETUP.................................................................................
5.1. Install Batteries...........................................................................
5.2. Select probe................................................................................
5.3. Connect the Hall probe..............................................................
5.4. Turn on apparatus......................................................................
5.5. Null Probe....................................................................................
6. OPERATION......................................................................................
6.1. Turn on meter..............................................................................
6.2. Gauss/mT....................................................................................
6.3. Handing probe............................................................................
6.4. Probe operation..........................................................................
6.5. Hold...............................................................................................
7. IN CASE OF TROUBLE..................................................................
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
1. GENERAL DESCRIPTION
The TD8620 Handheld Digital Teslameter is a field-portable unit
that measures DC magnetic fields with direct digital readout in mT
or Gs. The unit is designed for wide range, auto-range, high
accuracy, and ease of use .
2. SPECIFICATIONS
2.1. TD8620-5
Range 200 mT 2000 mT
Scope Maximum calibration field 2400 mT, 24 kiloguass
Resolution 10 μT
0~1000 mT:±2%
Accuracy
1000 mT ~ 2400 mT:±5%
Display 4 digit(in Decimal)
Power Stud-snap Battery Operated ;one section of 9 V battery
Operating environment 0℃ ~ 50℃
Storage temperature -20℃ ~ 50℃
Dimensions 160 mm × 80 mm × 32 mm
Weight 260 g(include battery and cable)
Hall probe Transverse probe , with 1 m cable
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
3. INTRODUCTION
TD8620 Handheld Digital Teslameter front panel is shown in Fig1.
Hall Probe interface
LCD
On/Off mT/Gs
Hold Null
Backlight
Fig 1 Front Panel
TD 8620 front panel key are defined as follows.
1) ON/OFF: Turns power to the unit on/off.
2) Hold: Turn Max Hold feature on and off. Max Hold captures and
displays the highest field reading.
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
3) : Turn backlight feature on and off. Backlight lighten up the
LCD for reading.
4) NULL: Used to zero or null effects of ambient low level fields
from the probe. When user pushes the NULL key ,”0.000 GS/
(mT)”displayed. The unit then automatically accepts whatever
residual field it reads as a zero offset .
5) mT/Gs: Changes units from mT to gauss .Gauss is used in the
cgs system :1 Gs=0.1 mT,mT is used in the SI system :1 mT
=10 G s
Fig 2 LCD Display
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
screw hole
One 9V stud-snap ba ery
Ba ery door
Fig 3 Rear Panel
When the stud-snap battery is used up, you should take the follow
steps to replace it. Firstly, use a long-stemmed driver to remove off
the screw which on the hole shown in the fig 3. Secondly, unfasten
the snap of the battery, then take a new battery replace of the
old ,fasten the snap , screw on. Finally replace the battery door.
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
4. AXIAL AND TRANSVERSE PROBES
TD8620 can use either the axial or transverse probe shown in Fig
4.
Fig 4 Transverse and axial probe
CAUTION :Care must be taken when handing the probe .The tip of
the probe is very fragile .Pressure the Hall sensor can alter its
calibration. Don’t apply more force than is required to hold probe in
place. So there is no excessive pressure which will tend to bend or
depress the sensor substrate and will destroy the Hall element inside.
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
5. INITIAL SETUP
5.1. Install Ba eries
When the stud-snap battery is used up, you should take the follow
steps to replace it. Secondly, unfasten the snap of the battery, then
take a new battery replace of the old ,fasten the snap ,screw on.
Finally replace the battery door.
5.2. Select probe
You can select the axial or transverse probe.
5.3. Connect the Hall probe
Plug the probe into the male connector at the top of the teslameter.
Make sure that the groove of female connector with the probe and
bump of the male connector be matched shown in Fig 5 . However,
it is most important that certain precautions be taken when handing
and installing probes so that they are not damage or destroyed ,and
to preserve their accurate calibration.
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
groove
female connector
bump
male connector
Fig 5 connectors
5.4. Turn on apparatus
Push the ON/OFF key on. The LCD displays like Fig 2.
5.5. Null Probe
It is good practice to zero the instrument immediately prior to
making critical field measurements. For absolute zeroing ,place the
probe in a zero-field region, either in a zero field chamber or inside
a suitable , magnetic field , so that the probe is shielded from the
earth’s magnetic field and other stray fields.
If desired ,a relative zero setting may be done; the instrument is
zeroed after the probe is placed in its measurement position .Thus
any ambient field is automatically subtracted from subsequent
measurement. The probe should not be moved once zeroing is
complete.
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
6. OPERATION
6.1. Turn on meter
Push the On/Off key. The LCD displays parameters as range,
polarity, value, unit ,battery indicator, percent of range and so on.
6.2. Gauss/mT
Press the Gauss/mT key to toggles the display between the two
units.
6.3. Handing probe
The tip of the probe is very fragile. Stressing the Hall senor alter its
calibration. Any excess force can easily break the sensor. Broken
sensor are not repairable. The axial sensor is exposed on the end
of the probe. A collision with a hard surface can damage the sensor
or wear away its protective coating. The transverse sensor is
somewhat susceptible to bending stress and erosion of the
protective coating.
When the meter is not in use, the probe should be mounted by
cover.
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
6.4. Probe operation
For best results , the instrument and probe should warm up for at
least 10 minutes before operation.
When magnetic field forward vertical cross the Hall sensor ,the
polarity is positive(+)see Fig 6,or is negative (-)
Fig 6 positive(+) measurement
Probe readings are dependent on the angle of the sensor in relation
to the magnetic field. The magnetic field should Vertical cross the
sensor. Maximum output occurs when the flux vector is
perpendicular to the plane of the sensor. The greater the deviation
from Vertical orientation ,the larger error of reading.
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
Fig 7 Effect of Angle on Measurement
6.5. Hold
The Hold function display the largest field magnitude
measured .When the Hold key is pressed, the maximum value is
captured and shown in the display. The “Hold” is displayed in the
LCD like in Fig 2. Press the Hold key again, Hold function will be
turn off ,the “Hold” is disappear .The meter is real-time
measurement of magnetic field.
Marketed in India by ACUTEK
TD8620 Handheld Digital Gauss Meter
7. IN CASE OF TROUBLE
1. Can’t turn on the power or automatic shut off. The
solution :check the battery install correctly and the power is
sufficient .If not please take the steps like the section “INITIAL
SETUP” to change a new battery or fasten the snap.
2. The LCD can’t light up . Check the female connector of probe
and the male connector at the top of TD8620 tighten or connected
correctly.
Marketed in India by ACUTEK