Remark:
1) The terminal 24V,COM of the monitoring
board MIB-A is DC24V power supply;
MCB-C2 MCB-C2 MCB-C2 2) J11 is used to connect to PC, it is used
DB9 DB9 DB9 to connect computer serial port in
monitoring room;
3) J12 is used to connect machine room
and monitoring room by the ModBUS
J11 J11 J11
TX RX GND
RJ45
TX RX GND
RJ45
TX RX GND
RJ45 MOD+, MOD- ;
4) J14 and J15 are terminal matching
MIB-A MIB-A MIB-A resistor.
24V MOD+ MOD- COM
J14 24V MOD+ MOD- COM
J14 24V MOD+ MOD- COM
J14 5) RJ45 is used to connect to the
J15 J15 J15
ON OFF ON OFF ON OFF operator;Monitoring board function
J12 J12 J12
parameters: the F0-02 is used to set
301 1# elevator 301 2# elevator 301
N# elevator address code, machine room address is
302 302 302
controller controller controller set to 1 ~ 32 according to the
requirements respectively, monitoring
room is set to 200; F0-06 is used to set
the total of monitoring elevators , the
maximum value is 32.
6) definitions of indicators
Monitor Room
OK: power supply and single board are
AC220V
normal;
user supply
S1: computer communication is normal;
J12
ON OFF
S2:485 network communication is normal;
L N 24V+ 24V- 24V MOD+ MOD- COM
J15 7) 485 communication cable adopts
J14
DC24V Power MIB-A PC RVVSP2* 0.75mm squared twisted-pair
Monitor Power shielded wire.
TX RX GND
RJ45 DB9
J11
Changes DWG
Rev PC Modificator Date The reasons for the change PRODUCT
Rev1
Rev2 CRT
Rev3 WISH8000 DRAW [Link] DATE
Rev4 Control cabinet CHK
APPD
2020-10-30
NOW NEXT
Rev5 AUTH EN20103001 1 2