HEADQUARTER

Cemp srl
Via Piemonte 16
20030 Senago (Milano) - Italy
Phone: +39 0294435401
[email protected]

OFFICES
Germany
Dr. Atzinger-Strasse 5
94036 Passau - Germany
Phone: +49 (0)8519662320

France
14 rue des Cours Neuves,
77135 Pontcarré - France
Phone: +33 (0)164668736

Cemp S.r.l.
Via Piemonte, 16
20030 Senago (Milan) - Italy

CERTIFICATES
Phone: +39 02 94435401
Technical Service: 800-626-2093
www.regalbeloit.com

AT E X , I E C E x , C U - T R , A E x , U L , C SA a n d m o r e
APPLICATION CONSIDERATIONS
The proper selection and application of power transmission products and components, including the related area of product safety,
is the responsibility of the customer. Operating and performance requirements and potential associated issues will vary appreciably
depending upon the use and application of such products and components. The scope of the technical and application information
included in this publication is necessarily limited. Unusual operating environments and conditions, lubrication requirements, loading
supports, and other factors can materially affect the application and operating results of the products and components and the custom-
er should carefully review its requirements. Any technical advice or review furnished by Regal Beloit America, Inc. and/or its affiliates
(“Regal”) with respect to the use of products and components is given in good faith and without charge, and Regal assumes no obliga-
tion or liability for the advice given, or results obtained, all such advice and review being given and accepted at customer’s risk.
For a copy of our Standard Terms and Conditions of Sale, please visit http://www.regalbeloit.com (please see link at bottom of page
to “Standard Terms and Conditions of Sale”). These terms and conditions of sale, disclaimers and limitations of liability apply to any
person who may buy, acquire or use a Regal product referred to herein, including any person who buys from a licensed distributor of
these branded products.

All brands and trademarks are the property of their respective companies and are protected by trademark or copyright law. Regal and Cemp are trademarks of Regal Beloit Corporation or one of its affiliated companies.
©2017, 2018 Regal Beloit Corporation, All Rights Reserved. MCB18014E • Form# 10210E
QUALITY SYSTEM
QUALITY AND ASSURANCE NOTIFICATION
PRODUCTS CERTIFICATION
FIDUCIARY TEST ROOM

ATEX IECEx WHO WE WORK WITH


CERTIFICATE EFFICIENCY ATEX AMBIENT ACCORDING TO CERTIFICATE EFFICIENCY AMBIENT ACCORDING TO
SERIES PROTECTION TYPE SERIES PROTECTION TYPE
NUMBER LEVEL CAT. TEMPERATURE STANDARDS NUMBER LEVEL TEMPERATURE STANDARDS

II 2G Ex db - Ex db eb IIB-IIC T3- T6 Gb NOTIFIED BODIES MAIN CERTIFICATES NOTIFIED BODIES MAIN


E3AC-E3AB- E3AM Ex db - Ex db eb IIB-IIC T3- T6 Gb -20°C +80°C / E3AC- E3AB- E3AM -20°C +80°C /
E4AC-E4AB-E4AM TÜV CY 17ATEX 0205845 X
IE1, IE2, IE3, II 2D
Ex tb IIIC - IIIB T 150-85 °C Db -60°C +80°C IECEx CML 17.0019X IE3, IE4 Ex tb/tc IIIB - IIIC T 150-85 °C Db/Dc CERTIFICATES
IE4 II 2GD E4AC- E4AB- E4AM 80-315L -60°C +80°C
80-315L Ex db I Mb Ex db eb I Mb Ex db I Mb - Ex db eb I Mb
I M2 Pro d u c t Q u a lit y As s u ra n c e , Na n io « C C VE» I n te rte k C UT R
Cesi
-20°C +60°C / I EC Ex Q u a lit y As s e s s m e n t
ACr 63-315L TÜV IT 14 ATEX 050 X ACr 63-315L C ML I EC Ex Pe s o CCOE
Ex d - de IIC T3- T6 Gb -50°C +60°C
IE1, IE2
Ex db - Ex db eb IIC T3 - T6 Gb -20°C +60°C / Ex tb/tc IIIC - IIIB T 150-85 °C Db/Dc C SA C a n a d a & USA A Ex T ÜV R h e in la n d I t a lia I n m e tro
DCr-HCr 63-315M DCr-HCr 63-315L DC-HC 315L -20°C +60°C
TÜV IT 14 ATEX 050 X Ex tb IIIC - IIIB T 150-85 °C Db -50°C +60°C Ex- Ag e n c ija A tex , I EC Ex
IECEx EXA 16.0006X IEC 60079-0:2011 T ÜV Sü d I t a lia A tex , I EC Ex
DC-HC 315L -20°C +80°C /
ABr 63-315L IEC 60079-1:2014 I n te rte k A tex , I EC Ex
IE1, IE2 Ex d - de IIB T3- T6 Gb -50°C +80°C T ÜV No rd I t a lia A tex , I EC Ex
ABr 63-315L TÜV IT 14 ATEX 065 X IE1, IE2 IEC 60079-7:2015 I Q Ne t - C I SQ - Q u a lit y m a n a g e m e n t s ys te m
Ex tb/tc IIIC - IIIB T 150-85 °C Db/Dc EN 60079-15:2010 Ha za rd o u s a n d
Ex db - Ex db eb IIB T3 - T6 Gb -20°C +80°C / DBr-HBr 63-315L DB-HB 315L -20°C +80°C UL
DBr-HBr 63-315M
IEC 60079-31:2013 o rd in a r y lo c a tio n
TÜV IT 14 ATEX 065 X Ex tb IIIC - IIIB T 150-85 °C Db -50°C +80°C AC 355 Ex db - Ex db eb IIB-IIC T3- T6 Gb -20°C +80°C /
DB-HB 315L II 2G IECEx EXA 15.0006X IE3, IE4
AB 355 Ex tb IIIC - T 150-85 °C Db -55°C +80°C
II 2GD
II 2D E3AN- E3AD- E3AQ Ex ec IIC - IIB T3 Gc
Ex db - Ex db eb IIC T3 - T6 Gb -20°C +60°C / IECEx EXA IE3, IE4 - 60°C +80°C
AC 355 TÜV IT 15 ATEX 023 X EN 60079-0:2012/ E4AN- E4AD- E4AQ 80-355 Ex tb IIIC - IIIB T 150-85 °C Db
Ex tb IIIC - IIIB T 150-85 °C Db -55°C +60°C
A11:2013
IE1, IE2, IE3, EN 60079-1:2014 TCN-TCT 80-355 IECEx UL 17.0104X IE3, IE4
Ex nA IIC T3 Gc
-20°C +50°C QUALITY SYSTEM PRODUCTION QUALITY PRODUCTS
IE4 EN 60079-7:2015 Ex tb IIIC T 150-85 °C Db ISO 9001.2015 ASSURANCE NOTIFICATION CERTIFICATION
EN 60079-15:2010 TCN-TCT-TCE IECEx EXA IE3, IE4 Ex eb-Ex ec/Ex tb-Ex tc -60°C +60°C
Ex db - Ex db eb IIB T3 - T6 Gb -20°C +80°C / C SQ - I Q Ne t - C I SQ A tex
AB 355 TÜV IT 15 ATEX 040 X EN 60079-31:2014 A tex UE UL USA
Ex tb IIIC - IIIB T 150-85 °C Db -55°C +80°C
I EC Ex C C O E I n d ia C SA C a n a d a + USA
certificates available at: http://iecex.iec.ch/
UL C UT R Ru s s ia
C SA I EC Ex
E3AN- E3AD- E3AQ
IE1, IE2, IE3, Ex ec IIC T3 Gc I n m e tro B ra zil
OTHER CERTIFICATIONS
E4AN- E4AD- E4AQ TÜV CY 17 ATEX 0205949 X -60°C +80°C
IE4 Ex tb IIIC T 150-85 °C Db KC S Ko re a n C e rtific a tio n
80-355
II 3G
II 2D EFFICIENCY AMBIENT ACCORDING TO
CERTIFICATION COUNTRY DESCRIPTION
II 3D LEVEL TEMPERATURE STANDARDS
Ex nA IIC - IIB T3 Gc
AN-AD-AQ-DD-HD Ex db IIC/IIB T4 Gb
TÜV IT 13 ATEX 006 X IE1, IE2 Ex tb IIIC - IIIB T 150-85 °C Db -50°C +80°C -20°C + 80°C /
63-315L AEx USA & Canada IE3, IE4 Class I Zone 1 AEx db IIC/IIB T4 Gb CSA 60079.1
Ex tc IIIC - IIIB T 150-85 °C Dc -60°C + 80°C
AB-AC
Standard,
SHIPPING CLASSIFICATION SOCIETIES FIDUCIARY
UL, CSA USA & Canada High Efficiency EPAct,
Division 1 - Explosion Proof - -25°C + 40°C NEMA MG1-2006, TEST ROOM
II 2D Ex nA IIC T3 Gc Class I & II, Group C, D, F, G and above Part 31, Section 4.4.2
TCN-TCT 80-355 DEMKO 17 ATEX 1952 X IE3, IE4 -20°C +50°C Premium Efficiency
II 3G Ex tb IIIC T 150-85 °C Db A m e ric a n B u re a u o f Sh ip p in g Ko re a n Re g is te r o f Sh ip p in g B u re a u Ve rit a s
-20°C + 60°C / B u re a u Ve rit a s L loyd Re g is te r Ko re a n Re g is te r o f Sh ip p in g
CCOE India ABr 63-315M; ACr 63-315M IS / IEC
-50°C + 60°C
De t No rs ke Ve rit a s Nip p o n Ka iji Kyo k a i Tüv Sü d I t a lia
Russia, Kazakhstan, AB-AC-AM-AN-AD-AQ 63-355; -20°C + 80°C / Ge rm a n is ch e r L loyd R . I . Na . Tüv No rd I t a lia
CUT R IE1, IE2, IE3, IE4 TP TC 012/2011
TCN-TCT-TCE II 2GD Belarus DB-DC-HB-HC 63-160; DB-DC 180-315 -60°C + 80°C
TÜV IT 18 ATEX IE3, IE4 Ex eb-Ex ec/Ex tb-Ex tc -60°C +80°C Ex- Ag e n c ija
80-355 II 3GD
AB-AC 63-315M; DB-DC-HB-HC 63- -20°C + 60°C /
IN MET RO Brazil ABNT NBR IEC
160; DB-DC 180-250 -50°C + 60°C