File 1620307458

This document provides installation and operation instructions for a hybrid inverter. It includes sections on safety, product overview, installation, operation, LCD display icons, operating modes, fault information and technical specifications. The installation section provides detailed instructions on mounting the inverter, making battery, AC and PV connections, and parallel configurations. The document contains important safety warnings and instructions for properly installing and using the hybrid inverter.

Uploaded by

Paulo Sergio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
303 views36 pages

File 1620307458

This document provides installation and operation instructions for a hybrid inverter. It includes sections on safety, product overview, installation, operation, LCD display icons, operating modes, fault information and technical specifications. The installation section provides detailed instructions on mounting the inverter, making battery, AC and PV connections, and parallel configurations. The document contains important safety warnings and instructions for properly installing and using the hybrid inverter.

Uploaded by

Paulo Sergio
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

R

Hybrid Inverter

User Manual
Contents
1. Safety Introductions ……………………………………………… 01
2. Product instructions ……………………………………………… 01-04
2.1 Product Overview
2.2 Product Features
2.3 Basic System Architecture
3. Installation …………………………………………………………… 04-16
3.1 Parts list
3.2 Mounting instructions
3.3 Battery connection
3.4 AC Input/Output Connection
3.5 PV Connection
3.6 CT Connection
3.7 Earth Connection(mandatory)
3.8 WIFI Connection
3.9 Wiring System for Inverter
3.10 Single phase parallel connection diagram
3.11 Three phase Parallel Inverter
4. OPERATION …………………………………………………………… 17
4.1 Power ON/OFF
4.2 Operation and Display Panel
5. LCD Display Icons …………………………………………………… 18-27
5.1 Main Screen
5.2 Solar Power Curve
5.3 Curve Page-Solar & Load & Grid
5.4 System Setup Menu
5.5 Basic Setup Menu
5.6 Battery Setup Menu
5.7 System Work Mode Setup Menu
5.8 Grid Setup Menu
5.9 Generator Port Use Setup Menu
5.10 Advanced Function Setup Menu
5.11 Device Info Setup Menu
6. Mode …………………………………………………………………… 27-29
7. Fault information and processing ………………………………… 29-31
8. Limitation of Liability ………………………………………………… 32
9. Datasheet ……………………………………………………………… 32-33
1. Safety Introductions

・This chapter contains important safety and operating instructions. Read and keep this
manual for future reference.
・Before using the inverter, please read the instructions and warning signs of the battery
and corresponding sections in the instruction manual.
・Do not disassemble the inverter. If you need maintenance or repair, take it to a
professional service center.
・Improper reassembly may result in electric shock or fire.
・To reduce risk of electric shock, disconnect all wires before attempting any maintenance
or cleaning. Turning off the unit will not reduce this risk.
・Caution: Only qualified personnel can install this device with battery.
・Never charge a frozen battery.
・For optimum operation of this inverter, please follow required specification to select
appropriate cable [Link] is very important to correctly operate this inverter.
・Be very cautious when working with metal tools on or around batteries. Dropping a
tool may cause a spark or short circuit in batteries or other electrical parts,even cause
an explosion.
・Please strictly follow installation procedure when you want to disconnect AC or DC
terminals. Please refer to ”Installation” section of this manual for the details.
・Grounding instructions - this inverter should be connected to a permanent grounded
wiring system. Be sure to comply with local requirements and regulation to install this
inverter.
・Never cause AC output and DC input short circuited. Do not connect to the mains
when DC input short circuits.

2. Product Introduction
This is a multifunctional inverter,combining functions of inverter, solar charger and
battery charger to offer uninterruptible power support with portable size. Its comprehensive
LCD display offers user configurable and easy accessible button operation such as battery
charging ,AC/solar charging, and acceptable input voltage based on different applications.

- 01 -
2.1 Product Overview

1
2
3

6
4 7
5
8
9

10
11
12
13
14
15

16
1: Inverter Indicators 7: DRMs Port 13: Power on/off button
2: LCD display 8: Parallel port 14: DC Switch
3: Function Buttons 9: Function Port 15: PV input with two MPPT
4: Battery input connectors 10: Generator input 16: WiFi Interface
5: RS 485 Port 11: Load
6: CAN Port 12: Grid

- 02 -
2.2 Product Features
・ -220V Single phase Pure sine wave inverter.
・ - Self-consumption and feed-in to the grid.
・ - Auto restart while AC is recovering.
・ - Programmable supply priority for battery or grid.
・ - Programmable multiple operation modes:On grid,off grid and UPS.
・ - Configurable battery charging current/voltage based on applications by LCD setting.
・ - Configurable AC/Solar/Generator Charger priority by LCD setting.
・ - Compatible with mains voltage or generator power.
・ - Overload/over temperature/short circuit protection.
・ - Smart battery charger design for optimized battery performance
・ - With limit function,prevent excess power overflow to the grid.
・ - Supporting WIFI monitoring and build-in 2 strings of MPP trackers
・ -Smart settable three stages MPPT charging for optimized battery performance.
・ -Time of use function.
・ -Smart Load Function.
・ -Parallel function On-Grid&Off-Grid.

2.3 Basic System Architecture

The following illustration shows basic application of this inverter.


It also includes following devices to have a Complete running system.
- Generator or Utility
- PV modules
Consult with your system integrator for other possible system architectures depending on your
requirements.
This inverter can power all kinds of appliances in home or office environment, including motor
type appliances such as refrigerator and air conditioner.

- 03 -
AC cable DC cable

WiFI
GPRS

Cloud services phone

Wind Solar Backup Load On-Grid Home Load Grid

CT

Battery Smart Load Grid-connected Inverter Generator


CT ATS

3. Installation
3.1 Parts List
Check the equipment before installation. Please make sure nothing is damaged in the
package. You should have received the items in the following package:

1 2 3 4 5

6 7 8 9
No Description Qty
1 SUN-3.6K/5K-SG01/03LP1-EU hybrid inverter 1
2 Stainless steel mounting screws M6*12 2
3 Stainless steel expansion bolts M8*80 4
4 User manual 1
5 WiFi plug 1

- 04 -
6 Current transformer (Optional) 1
7 Battery sensor 1
8 L-type Hexagon wrench 1
9 Wall mounting bracket 1
Chart 3-1 Parts List
3.2 Mounting instructions
Installation Precaution
This Hybrid inverter is designed for outdoor use(IP65),Please make sure the installation
site meets below conditions:
・ Not in direct sunlight
・ Not in areas where highly flammable materials are stored.
・ Not in potential explosive areas.
・ Not in the cool air directly.
・ Not near the television Antenna or antenna cable.
・ Not higher than altitude of about 2000 meters above sea level.
・ Not in environment of precipitation or humidity(>95%)
Please AVOID direct sunlight, rain exposure, snow laying up during installation and
operation. Before connecting all wires,please take off the metal cover by removing
screws as shown below:

Considering the following points before selecting where to install:


・ Please select a vertical wall with load-bearing capacity for installation, suitable for
installation on concrete or other non-flammable surfaces,installation is shown below.
・ Install this inverter at eye level in order to allow the LCD display to be read at all times.

- 05 -
・ The ambient temperature should be between -25~60℃ to ensure optimal operation.
・ Be sure to keep other objects and surfaces as shown in the diagram to guarantee
sufficient heat dissipation and have enough space for removing wires.
≥500mm

≥500mm

For proper air circulation to dissipate heat, allow a clearance of approx. 50cm to the side
and approx.50cm above and below the [Link] 100cm to the front.

Mounting the inverter


Inverter should vertically installed, as shown,installation procedure show below:
1. Position the bolts on the appropriate wall according to the bolt positions on the
mounting shelves and mark the holes. On the brick wall, the installation must be
suitable for the expansion bolt installation.

[Link] that the position of the installation holes on the wall (A, B, C, D) are the same
position of the install plate, and the mounting level is guaranteed.

3. Hang the inverter to the top of the mounting rack and then use the M4 screw in the
accessory to lock E and F to ensure that the inverter does not move.

- 06 -
Inverter hanging plate installation

3.3 Battery connection


For safe operation and compliance, a separate DC over-current protector or disconnect
device is required between the battery and the inverter. In some applications, switching
devices may not be required but over-current protectors are still required. Refer to the
typical amperage in the table below for the required fuse or circuit breaker size.

Model Wire Size Cable(mm 2 ) Torque value(max)


3.6/5KW 3AWG 25 5.2Nm

Chart 3-2 Cable size

- 07 -
All wiring must be performed by a professional person.

Connecting the battery with a suitable cable is important for safe and
efficient operation of the system. To reduce the risk of injury, refer to
Chart 3-2 for recommended cables.

Please follow below steps to implement battery connection:


1. Please choose a suitable battery cable with correct connector which can well fit into the
battery terminals. 2. Use a suitable screwdriver to unscrew the bolts and fit the battery
connectors in,then fasten the bolt by the screwdriver,make sure the bolts are tightened
with torque of 5.2 N.M.
2. Nm in clockwise direction,make sure polarity at both the battery and inverter is correctly
connected.

3. In case of children touch or insects go into the inverter,Please make sure the inverter
connector is fasten to waterproof position by twist it clockwise.

Installation must be performed with care.

Before making the final DC connection or closing DC breaker/


disconnect,be sure positive(+) must be connect to positive(+)
and negative(-) must be connected to negative(-). Reverse polarity
connection on battery will damage the inverter.

- 08 -
3.3.2 Battery temperature connection

1 2

Temp. CT

- 09 -
3.4 AC Input/Output Connection
・ Before connecting to AC input power source,please install a separate AC breaker
between inverter and AC input power [Link] will ensure the inverter can be securely
disconnected during maintenance and fully protected from over current of AC [Link]
recommended of AC breaker is 25A for 3.6kw and 32A for 5KW.
・ There are three terminal blocks with “Grid”“Load”and “GEN”markings.
Please do not misconnect input and output connectors.

All wiring must be performed by a qualified [Link] is very important


for system safety and efficient operation to use appropriate cable for AC
input connection. To reduce risk of injury,please use the proper
recommended cable as below.

Model Wire Size Cable(mm 2 ) Torque value


3.6KW 12AWG 4 1.2Nm
5KW 10AWG 6 1.2Nm

Chart 3-3 Recommended Size for AC wires


Please follow below steps to implement AC input/output connection:
1. Before making AC input/output connection,be sure to open DC protector or
disconnector first.
2. Remove insulation sleeve 10mm length,unscrew the bolts,insert the AC input wires
according to polarities indicated on the terminal block and tighten the terminal screws.
Make sure the connection is complete.

GEN PORT

Load
PE
L Grid
N
- 10 -
Be sure that AC power source is disconnected before attempting to wire it to
the unit.

3. Then,insert AC output wires according to polarities indicated on the terminal block and
tighten terminal. Be sure to connect corresponding N wires and PE wires to related
terminals as well.
4. Make sure the wires are securely connected.
5. Appliances such as air conditioner are required at least 2-3 minutes to restart because it
is required to have enough time to balance refrigerant gas inside of [Link] a power
shortage occurs and recovers in short time,it will cause damage to your connected
[Link] prevent this kind of damage,please check manufacturer of air conditioner
if it is equipped with time-delay function before [Link],this inverter will
trigger overload fault and cut off output to protect your appliance but sometimes it still
causes internal damage to the air conditioner.

3.5 PV Connection
Before connecting to PV modules,please install a separately DC circuit breaker between
inverter and PV [Link] is very important for system safety and efficient operation to
use appropriate cable for PV module [Link] reduce risk of injury,please use the
proper recommended cable size as below.

Model Wire Size Cable(mm 2 )


3.6/5KW 12AWG 4

Chart 3-4 Cable size

To avoid any malfunction, do not connect any PV modules with possible


current leakage to the inverter. For example, grounded PV modules will
cause current leakage to the inverter. When using PV modules, please be
sure NO grounding.

- 11 -
It is requested to use PV junction box with surge protection. Otherwise,it
will cause damage on inverter when lightning occurs on PV modules.

3.5.1 PV Module Selection:


When selecting proper PV modules, please be sure to consider below parameters:
1) Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit
voltage of inverter.
2) Open circuit Voltage (Voc) of PV modules should be higher than min. start voltage.

Inverter Model 3.6KW 5KW


PV Input Voltage (V) 370V(100V~500V)
PV Array MPPT Voltage Range 125Vdc-425Vdc
No. of MPP Trackers 2
No. of Strings per MPP Tracker 1+1

Chart 3-5

- 12 -
3.6 CT Connection

Inverter

White wire Black wire N L PE


3 4

3
4

CT
L
Grid

3.7 Earth Connection(mandatory)


Ground cable shall be connected to ground plate on grid side this prevents electric shock.
if the original protective conductor fails.

3.8 WIFI Connection


For the configuration of Wi-Fi Plug,please refer to illustrations of the Wi-Fi Plug.

- 13 -
Earth-BAR
Inverter

Ground
PE
N
3.9 Wiring System for Inverter

L
Breaker
CAN Grid

- 14 -
3 Breaker
Solar Battery 4 CT

Breaker
Breaker
Generator
Arrow pointing
or
to grid

Microinverter
or
Loads

Smart Load Loads


3.10 Single phase parallel connection diagram

Inverter
No.3
DSM 485 DSM CAN DRMs (slave)

Parallel A Parallel B
Ground

Inverter
Inverter
No.2
(slave)
PE wire

Inverter
No.1
N wire

(master)
L wire

L
N
+ - PE
CAN

Battery pack

Grid

Master inverter Slave Inverter Slave Inverter


Advanced Function Advanced Function Advanced Function
Parallel Modbus SN A Phase Parallel Modbus SN A Phase Parallel Modbus SN A Phase

Master 01 B Phase Master 02 B Phase Master 03 B Phase


Paral. Paral. Paral.
Slave C Phase Set3 Slave C Phase Set3 Slave C Phase Set3

Load

- 15 -
CAN L wire N wire PE wire
DSM 485 DSM CAN DRMs

Inverter No.1(master) Inverter No.2(slave) Inverter No.3(slave)


Parallel A Parallel B

GEN Load Grid GEN Load Grid GEN Load Grid

CAN

L3
3.11 Three phase Parallel Inverter

L2
L1
+ - N
PE

- 16 -
Battery pack

L1
L2
L3
N
PE

A Phase Master inverter B Phase Master inverter C Phase Master inverter


Advanced Function Advanced Function Advanced Function
Load Parallel Modbus SN A Phase Parallel Modbus SN A Phase Parallel Modbus SN A Phase

Master 01 B Phase Master 02 B Phase Master 03 B Phase


Paral. Paral. Paral.
Slave C Phase Set3 Slave C Phase Set3 Slave C Phase Set3

Grid
4. OPERATION
4.1 Power ON/OFF
Once the unit has been properly installed and the batteries are connected well,simply press
On/Off button(located on the left side of the case) to turn on the [Link] system without
battery connected,but connect with either PV or grid,and ON/OFF button is switched off,
LCD will still light up(Display will show OFF),In this condition,when switch on ON/OFF
button and select NO battery,system can still working.

4.2 Operation and Display Panel


The operation and display panel,shown in below chart,is on the front panel of the inverter.
It includes four indicators,four function keys and a LCD display,indicating the operating
status and input/output power information.

LED Indicator Messages


DC Green led solid light PV Connection normal
AC Green led solid light Grid Connection normal
Normal Green led solid light Inverter operating normal
Alarm Red led solid light Malfunction or warning

Chart 4-1 LED indicators

Function Key Description


Esc To exit setting mode
Up To go to previous selection
Down To go to next selection
Enter To confirm the selection

Chart 4-2 Function Buttons

- 17 -
5. LCD Display Icons
5.1 Main Screen
The LCD is touchscreen,below screen shows the overall information of the inverter.

05/28/2019 [Link]

0 4.50 5 0 -1.54 5
KW KW
ON

25%

0 -1.40
KW
5 0 1.46
KW
5

[Link] icon in the center of the home screen indicates that the system is Normal operation.
If it turns into “comm./F01~F64” ,it means the inverter has communication errors or
other errors,the error message will display under this icon(F01-F64 errors,detail error info
can be viewed in the System Alarms menu).
[Link] the top of the screen is the time.
[Link] Setup Icon,Press this set button,you can enter into the system setup screen which
including Basic Setup,Battery Setup,Grid Setup,System Work Mode,Generator port use,
Advanced function and Li-Batt info.
[Link] main screen showing the info including Solar,Grid,Load and [Link] also
displaying the energy flow direction by [Link] the power is approximate to high
level,the color on the panels will changing from green to red so system info showing
vividly on the main screen.
・ PV power and Load power always keep positive.
・ Grid power negative means sell to grid,positive means get from grid.
・ Battery power negative means charge,positive means discharge.

- 18 -
5.1.1 LCD operation flow chart

Solar Page Solar Graph

Grid Page Grid Graph

Inverter Page
Main Screen
Battery Page BMS Page

Load Page Load Graph

Battery Setting

System Work Mode

Grid Setting

System Setup
Gen Port Use

Basic Setting

Advanced Function

Device info

- 19 -
5.2 Solar Power Curve

Solar This is Solar Panel detail page.


Power: 1560W ① Today=8.0 KWH ① Solar Panel Generation.

PV1-V: 286V PV2-V: 45V Total =12.00 KWH ② Voltage,Current,Power for each MPPT.
PV1-|: 5.5A PV2-|: 0.0A ② ③ Solar Panel energy for Day and Total.
P1: 1559W P2: 1W

Press the “Energy “button will enter into the power


Energy curve page.

Inverter This is Inverter detail page.


Power: 44W ① DC-T:52.6C ③
① Inverter Generation.
② Voltage,Current,Power for each Phase.
L1: 240V L2: 0V AC-T:41.0C
② ③ DC-T:mean DC-DC temperature,
l1:0.6A l2:0.0A
AC-T:mean Heat-sink temperature.
Power1: 0W

Power2: 0W

Load This is Back-up Load detail page.


Power: 42W ① Today=0.0 KWH ① Back-up Power.

L1: 240V L2: 0V Total =0.80 KWH
② Voltage,Power for each Phase.
② ③ Back-up consumption for Day and Total.
P1: 0W P2: 0W

Press the “Energy “button will enter into the power


curve page.
Press the “Forced “button will forced open the smart-
Forced Energy load(While GEN PORT utilized as Smart-load output).

Grid This is Grid detail page.


Stand-by ① BUY ③ ① Status,Power,Frequency.
Power: 0W Today=2.2KWH ② L1&L2:Voltage for each Phase
Total =11.60 KWH
0.0Hz
CT1&CT2:External Current Sensor Power
SELL
LD1&LD2:Internal Current Sensor Power.
L1: 0V L2: 0V ② Today=0.0KWH
CT1: 0W CT2: 0W Total =8.60 KWH
③ BUY:Energy from Grid to Inverter,
SELL:Energy from Inverter to Load.
LD1: 0W LD2: 0W
Press the “Energy “button will enter into the power
Energy
curve page.

- 20 -
Li-BMS

Mean Voltage:50.34V Charging Voltage :53.2V


Batt Total Current:55.00A Discharging Voltage :47.0V Sum
Mean Temp :23.5C Charging current :50A Data

Stand-by Total SOC :38% Discharging current :25A


Dump Energy:57Ah
SOC: 36% Details
Data

U:50.50V

I:-58.02A
Li-BMS
Power: -2930W Volt Curr Temp SOC Energy Charge Fault
Volt Curr
1 50.38V 19.70A 30.6C 52.0% 26.0Ah 0.0V 0.0A 0|0|0
Temp:30.0C
Li-BMS 2
3
50.33V
50.30V
19.10A
16.90A
31.0C
30.2C
51.0%
12.0%
25.5Ah
6.0Ah
53.2V
53.2V
25.0A
25.0A
0|0|0
0|0|0
Sum
4 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0 Data
5 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
6 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
7 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
8 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
This is Battery detail page. 9 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
Details
10 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
11 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0 Data
if you use Lithium Battery,you can enter BMS page. 12
13
0.00V
0.00V
0.00A
0.00A
0.0C
0.0C
0.0%
0.0%
0.0Ah
0.0Ah
0.0V
0.0V
0.0A
0.0A
0|0|0
0|0|0
14 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
15 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0

5.3 Curve Page-Solar & Load & Grid

Solar Power Production:Day System Solar Power:Month


3000W 2019-5-28 2000Wh 5-2019
100% 2000
80% 1600
60% 1200
40% 800
20% 400
0
1 3 5 7 9 11 13 15 17 19 21 23 05 10 15 20 25 30

CANCEL Day Month Year Total CANCEL Day Month Year Total

System Solar Power:Year System Grid Power:Total


KWh 2019 2000KWh Total
200 2000
160 1600
120 1200
80 800
40 400
0
1 2 3 4 5 6 7 8 9 10 11 12 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20 20
16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48

CANCEL Day Month Year Total CANCEL Day Month Year Total

Solar power curve for daily,monthly,yearly and total can be roughly checked on the LCD,
For more accuracy power generation,pls check on the monitoring [Link] the up and
down arrow to check power curve of different period.

- 21 -
5.4 System Setup Menu

System Setup
This is System Setup page.
System Work Mode
Battery
Setting Gen Port
Grid Setting Use

Basic Advanced
Setting Function Device Info.

5.5 Basic Setup Menu

Basic Setting
This is Basic Setup page.
Time Syncs Beep Auto Dim

Year Month Day Basic


2019 03 17
Set

Hour Minute
24-Hour 09 15

Factory Reset Lock out all changes

5.6 Battery Setup Menu

Battery Setting Lithium Battery


Batt Mode
Batt Mode-------- Lithium
Lithium Batt Capacity 400Ah
Batt
Mode
Max A charge-------- 0-120A
Use Batt V Max A Charge 40A
Max A Discharge-----0-120A
Use Batt % Max A Discharge 40A Activate Battery------Enable
No Batt
Activate Battery
AGM Battery
Batt Mode-------- Use Batt V or Use Batt V%
Batt Capacity-------- 50-2000Ah
Max A charge-------- 0-120A
Max A Discharge-----0-120A
Activate Battery ------Enable
No Batt --- No need to set other parameters,
keep the default value.

- 22 -
Battery Setting This is Battery Setup page. ① ③
Start 30% 30% ② Start =30%---It indicates that the Generator will start when
the Battery capacity is less than 30% in Off-grid mode.
A
① 40A 40A
Batt
Set2 A = 40A---It indicates the Current that the Generator
Gen Charge Grid Charge charges the Battery after starting.

Gen Signal Grid Signal


Gen Charge---It indicates the Switch that the Generator
charges the Battery。
Gen Max Run Time 0.0 hours
③ Gen Signal ---It indicates whether the Generator's ATS
Gen Down Time 0.5 hours signal is on or off.
Gen Max RunTime ---It indicates the longest time
Generator can run in one day,when time is up, the
Generator will be turned off. 24H means that it does
not shut down all the time.
Gen DownTime ---It indicates the delay time of the
Generator to shut down after it has reached the running
time.

This is Grid Charge, you need select. ②


Start =30%---No use,Just for customization.
A = 40A--- It indicates the Current that the Grid
charges the Battery.
Grid Charge---It indicates that the grid charges the battery.
Grid Signal ---Disable.

Battery Setting
Lithium Mode--This is BMS [Link] reference the
document(Approved Battery).
Lithium Mode 00
Shutdown 10%--It indicates the inverter will shutdown if
Batt
Shutdown 10% Set3 the SOC below this value.
Low Batt 20% --It indicates the inverter will alarm if the
Low Batt 30%
SOC below this value.
Restart 80% Restart 40% --It indicates the restart level when inverter
shutdown.

- 23 -
Battery Setting There are 4 stages of charging the Battery . ①
Float V ① 55.2V Shutdown ③ 41.0V
This is for professional installers,you can keep it if you
Absorption V 57.6V
Low Batt 45.0V
Batt do not know. ②
Restart 52.0V Set3

Equalization V 58.8V TEMPCO(mV/C/Cell)


Shutdown 41V--The inverter will shutdown if the Voltage
Equalization Days 90 days
② -5
below this value.
Batt Resistance Low Batt 45V --The inverter will alarm if the Voltage
Equalization Hours 2.0 hours
25mOhms below this value. ③
Restart 52V --Restart level when inverter shutdown.

5.7 System Work Mode Setup Menu


System Work Mode Work Mode
Selling First :It means that the excess energy has
Work Mode priority in grid connection.
Selling First Work
Zero Export To Load:It means output power according
Mode1 to it consumed by the load.
Zero Export To Load Solar Sell Zero Export To CT :It means output power according
to the CT position.
Zero Export To CT Solar Sell Solar Sell :It means that the excess solar energy
can be integrated into the grid.
Max Sell Power 5000 Zero-export Power 500
Max Sell Power 0-8000W
Energy pattern BattFirst LoadFirst Zero-export Power: the output power of grid when in
zero-export mode.
Energy Pattern
BattFirst--- It means solar power will charge battery first,
when battery is full then feed-out power to the
Load or Grid.
LoadFirst-- The solar energy will be used to supply the
local load first,then to charge the [Link]
redundant power will export to the public grid.

System Work Mode


Time of use
Grid Time Of Use Grid Charge : Switch for Grid charging the battery.
Charge Gen Time Power Batt
Work
01:00 5:00 5000 49.0V Mode2
Gen : Switch for Gen charging the battery.
05:00 9:00 5000 50.2V Time & Batt : There are six time period can be set,
09:00 13:00 5000 50.9V
each period must from small to large.
13:00 17:00 5000 51.4V Power : Max. discharge power of battery allowed.
17:00 21:00 5000 47.1V
21:00 01:00 5000 49.0V

- 24 -
5.8 Grid Setup Menu
Grid Setting
Please select the correct Grid Mode in your local area. If
Grid Mode General Standard
you are not sure, please choose General Standard.
UL1741& IEEE1547
Grid
CPUC RULE21 Set1 Please select the correct Grid Type in your local area,
SRD-UL-1741 otherwise the machine will not work or be damaged.
Grid Type 220V Single Phase
120/240V Split Phase
120/208V 3 Phase
120V Single Phase

Grid Setting UL1741&IEEE1547,CPUC RULE21,SRD-UL-1741


Grid Frequency 50HZ No need to set the function of this interface.
60HZ Grid General Standard
Set2
Reconnection Time 60S PF 1.000
Please select the correct Grid Frequency in your local area.
You can hole this in default value。
Grid HZ High 60.5Hz Grid Vol High 265.0V

Grid HZ Low 59.3Hz Grid Vol Low 185.0V

Grid Setting
For California only.
Q(V) FW VW

V1:0.0V Q1:0.00 Fstart:0.00Hz Vstart:0.0V Grid


Set3
V2:0.0V Q2:0.00 Fstop:0.00Hz Vstop:0.0V

Normal Ramp rate


V3:0.0V Q3:0.00
0.0%/s
V4:0.0V Q4:0.00 Soft Start Ramp rate
0.0%/s

Grid Setting
For California only.
L/HVRT L/HFRT

HV2:0.0V 0.16S Grid


Set4
HV1:0.0V 0.16S HF2:0.00HZ 0.16S

LV1:0.0V 0.16S HF1:0.00HZ 0.16S

LV2:0.0V 0.16S LF1:0.00HZ 0.16S

LV3:0.0V 0.16S LF2:0.00HZ 0.16S

- 25 -
5.9 Generator Port Use Setup Menu
GEN PORT USE Generator Input: use Generator
SmartLoad Output: if the SOC is up than “ON”and solar power
Mode is high than 1000W. the inverter will open smartload.
Generator Input On Grid always on: mean when have Grid, the smartload will always on.
Rated Power PORT Micro Inv Input: Inverter will open Microinverter. if the SOC is
8000W Set1
below the“ON”and close if the SOC is up than the“OFF”.
SmartLoad Output On Grid always on
AC Couple Fre High: If choosing“Micro Inv input”, as the
Power AC Couple Fre High
battery SOC reaches gradually setting value (OFF), During the
process, the microinverter output power will decrease linear. When
500W 52.00Hz
OFF 95% the battery SOC equals to the setting value (OFF), the system
Micro Inv Input ON 100%
frequency will become the setting value (AC couple Fre high)
and the Microinverter will stop working.
Ml export to Grid cutoff
MI export to grid cutsoff: stop exporting power produced by the
microinverter to the grid.

5.10 Advanced Function Setup Menu

Advanced Function Solar Arc Fault ON---This is only for US.


Solar Arc Fault ON Backup Delay System selfcheck---Disable. this is only for factory.
0S
Clear Arc_Fault Func Gen Peak-shaving---Enable When the power of the
Set1 generator exceeds the rated value of it, the inverter will
System selfcheck Gen peak-shaving
provide the redundant part to ensure that the generator
DRM Grid peak-shaving
will not overload.
Power 1000W Grid Peak-shaving---Enable When the power of the grid
Signal ISLAND MODE
exceeds the set value, the inverter will provide the
BMS_Err_Stop redundant part to ensure that the grid power does not
exceed the set value.
DRM---For AS4777 standard
Inverter
Backup Delay---Reserved
load port
shell BMS_Err_Stop---When the battery BMS failed to
L N ATS communicate with inverter, the inverter will stop working.
Ground cable Signal island mode---when the inverter connects grid,
230V
the ATS port will output 230Vac and it is used to cuts off
Earth-Neutral(load port N line) bond via connect external
relay. When the inverter disconnects from the grid, ATS
port voltage will be 0 and the Earth-Neutral bond keeps
external relay on. More details, please refer to left picture.
coil
closed
contact

Advanced Function
This is for Wind Turbine
DC1 for WindTurbine DC2 for WindTurbine

V1 0V 0.0A V7 0V 0.0A
Wind
Set2
V2 0V 0.0A V8 0V 0.0A

V3 0V 0.0A V9 0V 0.0A

V4 0V 0.0A V10 0V 0.0A

V5 0V 0.0A V11 0V 0.0A

V6 0V 0.0A V12 0V 0.0A

- 26 -
PassWord
Factory Reset: 9999
X--X--X--X DEL Lock out all changes:7777
1 2 3

4 5 6

7 8 9

CANCEL 0 OK

5.11 Device Info Setup Menu

Li-BMS
Device Info.
Volt Inverter
Curr Temp SOCID: 1601012001
Energy Charge Fault
This page show Inverter ID, Inverter version
HMI: Ver0302 MAIN:Ver1400
Volt Curr and alarm codes.
1 50.38V 19.70A 30.6C 52.0% 26.0Ah 0.0V 0.0A 0|0|0
Alarms Code31.0C 51.0% 25.5Ah
Occurred
2 50.33V 19.10A 53.2V 25.0A 0|0|0 Device
Sum
3 F64 Heatsink_HighTemp_Fault
50.30V 16.90A 30.2C 12.0% 6.0Ah2019-03-11 15:56
53.2V 25.0A 0|0|0
4 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
Info
Data
5 F64 Heatsink_HighTemp_Fault
0.00V 0.00A 0.0C 0.0% 0.0Ah2019-03-08
0.0V 0.0A 10:46
0|0|0
0.00V
6 F64 0.00A 0.0C 0.0% 0.0Ah2019-03-08
Heatsink_HighTemp_Fault 0.0V 0.0A 10:45
0|0|0 HMI: LCD version
7 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
8 0.00V 0.00A
9 0.00V 0.00A
0.0C
0.0C
0.0%
0.0%
0.0Ah
0.0Ah
0.0V
0.0V
0.0A 0|0|0
0.0A 0|0|0
MAIN: MCU version
10 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0 Details
11 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0 Data
12 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
13 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
14 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0
15 0.00V 0.00A 0.0C 0.0% 0.0Ah 0.0V 0.0A 0|0|0

6. Mode
Mode I:Basic

AC cable DC cable COM cable

Backup Load On-Grid Home Load

Solar

CT
Battery
Grid

- 27 -
Mode II: With Wind Turbine
AC cable DC cable

Wind

Backup Load On-Grid Home Load


Wind Turbine
Controller

Grid
CT
Battery

Mode III: With Generator

AC cable DC cable

Solar Backup Load On-Grid Home Load

Grid
CT

Battery

Generator

Mode IV: With Smart-Load

AC cable DC cable

Solar Backup Load On-Grid Home Load

Grid
CT

Battery

Smart Load

- 28 -
Mode V: With On-Grid Inverter

On-Grid+AC couple AC cable DC cable

Solar Backup Load On-Grid Home Load

Grid

Battery

Single Phase Inverter

The 1st priority power of the system is always the PV power,then 2nd and
3rd priority power will be the battery bank or grid according to the settings.
The last power backup will be the Generator if it is available.

7. Fault information and processing


The energy storage inverter is designed according to the grid-connected operation
standard and meets the safety requirements and electromagnetic compatibility
requirements. Before leaving the factory, the inverter undergoes several rigorous
tests to ensure that the inverter can operate reliably.

If any of the fault messages listed in Table 6-1 appear on your inverter and
the fault has not been removed after restarting, please contact your local dealer
or service center. You need to have the following information ready.

1. Inverter serial number;


2. Distributor or service center of the inverter ;
3. On-grid power generation date;
4. The problem description (including the fault code and indicator status displayed on the
LCD) is as detailed as possible.
5. Your contact [Link] order to give you a clearer understanding of the inverter's
fault information, we will list all possible fault codes and their descriptions when the
inverter is not working properly.

- 29 -
Error code Description Solutions

Inverter work mode changed


F13 Working mode change 1. wait for a minute and check;
2. Seek help from us, if can't go back to normal state.
AC side over current fault
1. Please check whether the backup load power and common
F18 AC over current fault load power are within the range;
of hardware 2. Restart and check whether it is in normal;
3. Seek help from us, if can not go back to normal state.
DC side over current fault
DC over current fault of 1. Check PV module connect and battery connect;
F20 2. Turn off the DC switch and AC switch and then wait one
the hardware minute,then turn on the DC/AC switch again;
3. Seek help from us, if can not go back to normal state.
Leakage current fault
AC leakage current is 1. Check the cable of PV module and inverter;
F23
transient over current 2. Restart inverter;
3. Seek help from us, if can not go back to normal state.
PV isolation resistance is too low
DC insulation impedance 1. Check the connection of PV panels and inverter is firmly and
F24 correctly;
failure 2. Check whether the PE cable of inverter is connected to ground;
3. Seek help from us, if can not go back to normal state.
1. Please wait for a while and check whether it is normal;
The DC busbar is 2. If still same, and turn off the DC switch and AC switch and
F26 wait for one minute and then turn on the DC/AC switch;
unbalanced
3. Seek help from us, if can not go back to normal state.

No Utility
1. Please confirm grid is lost or not;
F35 No AC grid 2. Check the grid connection is good or not;
3. Check the switch between inverter and grid is on or not;
4. Seek help from us, if can not go back to normal state.

Grid voltage fault


1. Check the AC voltage is in the range of standard voltage in
specification;
F42 AC line low voltage
2. Check whether grid AC cables are firmly and correctly
connected;
3. Seek help from us, if can not go back to normal state.

Grid frequency out of range


1. Check the frequency is in the range of specification or not;
F47 AC over frequency
2. Check whether AC cables are firmly and correctly connected;
3. Seek help from us, if can not go back to normal state.

Grid frequency out of range


1. Check the frequency is in the range of specification or not;
F48 AC lower frequency
2. Check whether AC cables are firmly and correctly connected;
3. Seek help from us, if can not go back to normal state.

- 30 -
Error code Description Solutions

Battery voltage low


DC busbar voltage is 1. Check whether battery voltage is too low;
F56 2. If the battery voltage is too low, using PV or grid to charge the
too low battery;
3. Seek help from us, if can not go back to normal state.

1. ARC fault detection is only for US market;


F63 ARC fault 2. Check PV module cable connection and clear the fault;
3. Seek help from us, if can not go back to normal state.
Heat sink temperature is too high
Heat sink high temperature 1. Check whether the work environment temperature is too high;
F64
failure 2. Turn off the inverter for 10mins and restart;
3. Seek help from us, if can not go back to normal state.

Chart 7-1 Fault information

Under the guidance of our company, customers return our products so that our company
can provide service of maintenance or replacement of products of the same value.
Customers need to pay the necessary freight and other related costs.
Any replacement or repair of the product will cover the remaining warranty period of the
product. If any part of the product or product is replaced by the company itself during the
warranty period, all rights and interests of the replacement product or component belong
to the company.
Factory warranty does not include damage due to the following reasons:

・ Damage during transportation of equipment;


・ Damage caused by incorrect installation or commissioning;
・ Damage caused by failure to comply with operation instructions, installation
instructions or maintenance instructions;
・ Damage caused by attempts to modify, alter or repair products;
・ Damage caused by incorrect use or operation;
・ Damage caused by insufficient ventilation of equipment;
・ Damage caused by failure to comply with applicable safety standards or regulations;
・ Damage caused by natural disasters or force majeure (e.g. floods, lightning, overvoltage,
storms, fires, etc.)

In addition, normal wear or any other failure will not affect the basic operation of the
product. Any external scratches, stains or natural mechanical wear does not represent
a defect in the product.

- 31 -
[Link] of Liability
In addition to the product warranty described above, the state and local laws and regulations
provide financial compensation for the product's power connection (including violation of
implied terms and warranties). The company hereby declares that the terms and conditions
of the product and the policy cannot and can only legally exclude all liability within a limited
scope.

9. Datasheet
SUN-3.6K-SG01/03LP1 SUN-5K-SG01/03LP1
Technical Data
-EU -EU
Battery Input Data
Battery Type Lead-acid or lithium-ion
Battery Voltage Range (V) 40V-60V
Max. Charging Current (A) 90A 120A
Max. Discharging Current (A) 90A 120A
Charging Curve 3 Stages/equalization
External Temperature Sensor Optional
Charging Strategy for Li-Ion Battery Self-adaption to BMS
PV String Input Data
Max. DC Input Power (W) 4680W 6500W
PV Input Voltage (V) 370V(100V~500V)
MPPT Range (V) 125~425V
Full Load DC Voltage Range 240V~425V

Start-up Voltage (V) 150V


PV Input Current (A) 11A+11A
No. of MPPT Trackers 2
No. of Strings per MPPT Tracker 1/1
AC Output Data
Rated AC Output and UPS Power (W) 3600W 5000W
Max. AC Output Power (W) 3960W 5500W
Peak Power(off grid) 2 times of rated power, 10 S
AC Output Rated Current(A) 15.7A 21.7A
Max. AC Current(A) 18A 25A

- 32 -
Max Continuous AC Passthrough (A) 35A
Power Factor 0.8 leading to 0.8 lagging
Output Frequency and Voltage 50/60Hz; 220/230/240Vac(single phase)

Grid type Single Phase


Current harmonic distortion THD<3%(Linear load) <1.5%

Efficiency
Max. Efficiency 97.60%
Euro Efficiency 96.50%
MPPT Efficiency 99.90%
Protection
PV Input Lightning Protection Integrated
Anti-islanding Protection Integrated
PV String Input Reverse Polarity Protection Integrated
Insulation Resistor Detection Integrated
Residual Current Monitoring Unit Integrated
Output Over Current Protection Integrated
Output Shorted Protection Integrated
Output Over Voltage Protection Integrated
Certifications and Standards
VDE 0126,AS4777,NRS2017,G98,G99,
Grid Regulation
IEC61683, IEC 62116, IEC 61727

Safety Regulation IEC62109-1, IEC62109-2

EMC EN61000-6-1, EN61000-6-3


General Data
Operating Temperature Range (℃) -25~60℃, >45℃ Derating
Cooling Fan
Noise (dB) <30
Communication with BMS RS485; CAN
Weight (kg) 20.5
Size (Width*Height*Depth mm) 580×330×208
Protection Degree IP65
Installation Style Wall-mounted
Warranty 5 years

- 33 -
Add: No.26-30, South Yongjiang Road, Beilun, 315806, Ningbo, China
Tel: +86 (0) 574 8622 8957
Fax: +86 (0) 574 8622 8852
E-mail: wutz@[Link]
Web: [Link]
Ver: 1.6, 2020-04