Yutaki Catalogue
Yutaki Catalogue
air to water
heat pumps
Yutaki range
2
–
Welcome
to Hitachi Cooling & Heating,
climate control solutions
Introduction
Contents
Heating and DHW 5
Selection guide 7
Benefits 8
Yutaki S 18
Yutaki S Combi 24
Yutaki S80 30
Yutaki M 36
*Depends on model
5
Heating
and DHW
New Yutaki indoor unit
Selection guide
Yutaki S Yutaki S Combi Yutaki S80 Yutaki M
Applications Low temperature radiators, under-floor Low temperature radiators, under-floor Low and/or high temperature Low temperature radiators, under-floor
heating/cooling, fan convectors, DHW, heating/cooling, fan convectors, built- radiators, under-floor heating, fan heating/cooling, fan convectors, DHW,
and pool heating. Ideal for new housing in DHW, and pool heating. Ideal for convectors (heating only), and pool and pool heating. Compact unit perfect
and for replacing wall-mounted boilers. homes with little space, thanks to the heating. Ideal for facilities requiring for facilities with less inside space.
built-in DHW tank. high temperatures, such as replacing
oil-fired boilers.
EER
4 4 - 3.54
35°C outside/7 - 12°C water
DHW temperature
- +75 - -
Max. °C
Compressor
Scroll & Rotary DC Inverter Scroll & Rotary DC Inverter Scroll DC Inverter Scroll & Rotary DC Inverter
Pipe adapter
Benefits
Yutaki air to water heat pumps
3 Hitachi have the widest range of capacities available for the domestic
air source heat pump market. From 4.3 kW units ideal for new builds
up to 24 kW units perfect for larger properties and retrofits.
Min - Max
RAS-2WHVRP1 1.85 - 7.0 RAS-2WHVRP1
Heating capacity range under the conditions: water input/output: 30/35 ºC; outside temperature: 7/6 ºC (WB/DB).
Nom-Max
RAS-2WHVRP1 3.8 - 4.9 RAS-2WHVRP1
RAS-2.5WHVRP1 5.0 - 5.8 RAS-2.5WHVRP1
RAS-3WHVRP1 6.0 - 7.0 RAS-3WHVRP1
RAS-4WH(V)NPE 7.2 - 11.8 RAS-4WH(V)NPE
RAS-5WH(V)NPE 9.5 - 12.6 RAS-5WH(V)NPE
RAS-6WH(V)NPE 10.5 - 13.7 RAS-6WH(V)NPE
RAS-8WHNPE 14.0 - 16.4 RAS-8WHNPE
RAS-10WHNPE 17.5 - 20.6 RAS-10WHNPE
Cooling capacity range under the conditions: water input/output: 23/18 ºC; outside temperature: 35 ºC (DB).
9
45 Hitachi high-efficiency
Scroll Compressor
Hitachi’s Scroll & Rotary DC Inverter compressor was The compressor is particularly effective in between
designed to increase seasonal efficiency and reliability seasons, offering high efficiency under low partial loads.
by reducing energy consumption.
5 Proven quality
SG Ready
Hitachi heat pumps can be integrated into the smart energy grids of
the future to help provide the low cost heating systems required to
meet carbon reduction targets.
Proven quality
All heat pumps and water heaters in the European market are
continuously tested by various certification schemes. These are usually
the basis for qualifying for state subsidies. Hitachi heat pumps meet
the high standards of the following quality accreditation schemes:
MCS, Keymark and KIWA.
10
Benefits
Yutaki air to water heat pumps
6Performance (%)
Savings from the
very first bill
Conventional gas
boiler
92%
Condensation
gas boiler
109%
Diesel boiler
89%
Electricity
(radiators)
100%
Heat pump
(Yutaki S 6 HP)
457%
Energy consumption (kWh/year) 21,042.39 17,760.55 21,751.69 19,359.00 4,236.11
7 Hitachi
Experience
manufacturing heating equipment, with over 4.5 The Yutaki range can provide heat with outside
million ASHP systems produced and in excess temperatures down to -25, uniquely to the market.
of 400,000 customers throughout Europe. Our It can also produce hot water up to 60º C without
European factory produces the entire Yutaki ASHP the need for a backup heater.
range, designing it to meet the needs of the local Yutaki systems are designed to work without
European market. Its nearby location means we can backup electrical heaters but some have them
control the whole design and manufacture process, factory fitted and for others they are an optional
thus guaranteeing the highest levels of quality, extra. Even when fitted the user can use the simple
reliability and durability in all our equipment. control systems to disable them.
11
9 Simple installation with Unlike other models on the market, all Yutaki
systems are designed for easy access to the
easy maintenance components, thus allowing straightforward
maintenance and ensuring cost savings.
Connections
– Filter ball shut-off valve: Yutaki units are fitted
with a ball valve containing an interchangeable
cylindrical filter that is easy to inspect and remove
for maintenance work. The individual valve has
two important functions: to perfectly seal the
ball valves and to carefully filter the fluid, with its
high-reliability protecting all the components in
Hitachi's Yutaki systems.
10 Yutaki, configured in
under 5 minutes
Benefits
Yutaki air to water heat pumps
11 Easy,
smart control
All Yutaki models have been designed to ensure space is not a problem.
Their compact size means they can be hidden away in confined spaces, even
inside a kitchen cabinet.
Yutaki models are compact and lightweight, designed for smaller surfaces,
without sacrificing power and efficiency.
13
13 No matter where
you are
Actual defrost
time
lower than
estimated
15 Additional
benefits
Expansion
valve
Jan Feb Mar Apr May Jun Jul Aug Sep Oct Nov Dec
─
0/&$. $)./''/$*)рҝт– .# (/$)ڤр
Cas avec production de chauffage / rafraichissement collective et production d’eau chaude sanitaire collective
─
Type d’application :
Dans le schéma ci-dessous, la production d’eau chaude sanitaire et de chauffage / rafraichissement n’est pas simultanée. Quand l’installation en cascade produit de l’eau
chaude pour le ballon d’ECS, la production d’eau chaude ou froide pour le chauffage ou le rafraichissement est stoppée, jusqu’à ce que la production d’ECS soit terminée.
Information complémentaire :
Dans ce cas de figure, le contrôleur de cascade Yutaki gère le ballon d’ECS ainsi que le chauffage et le rafraichissement de l’habitation. La gestion du circuit 1 et du circuit 2 est
réalisée par le contrôleur de cascade Yutaki, et peut être combinée avec des thermostats sans fil ou filaires ou toutes autres options compatibles. L’installateur doit déterminer
si l’usage de collecteurs hydrauliques est nécessaire et les dimensionner en conséquence.
─
Configuration du contrôleur de cascade
Circuit 1: Activé à loi d’eau par pente / par points / température fixe (option thermostat) ( circuit direct)
Circuit 2: Activé à loi d’eau par pente / par points / température fixe (option thermostat) ( circuit mélangé)
DHW: Activé
─
0/&$. $)./''/$*)сҝт– .# (/$)ڤр
─
0/&$. $)./''/$*)тҝт– .# (/$)ڤр
─
Bornier du Contrôleur de cascade Yutaki
─
Légende
))
)) Ѿ$.*' ( )/ )) )) $-0'/ 0-
(ĝ')" т (*/*-$.ĝ с Ѿĝ,0$'$-" Ѿ$.*' ( )/
1*$ . 1*$ .
*)/-ţ' 0-
ĝ.$./) 1)) .
ĝ' /-$,0 *)Ҋ- 1 -.$' 0/&$
..*$- . $/#$
..*$- .ø+-ĝ1*$-
16
Hi Kumo PRO
The remote maintenance solution for our entire
residential and small commercial buildings range.
Functions
Fast diagnostics to optimise interventions thanks to a
simple and user-friendly interface.
Access to real-time machine operating data* Access to the entire system library:
- Operating status / mode - Map or list view.
- Setpoint and actual Temp°. - Options to save systems as
- Temp° of the gas / discharge / evaporation. favourites.
- Compressor current / frequency.
- Water flow and temperatures.
- Pump speed.
- V3V position.
Remote control:
- Access to the same control functions
as the Hi Kumo solution except weekly
Check the status, reboot and update programming.
Yutaki systems from the interface.
[Link] * For Air / Air products, access restricted to data from the internal unit
17
What are the benefits of the Hi Kumo PRO service?
1 2 3 4 5
The installation/ The end customer The installation/ The end customer That’s it,
maintenance engineer acquires the Hi maintenance engineer accepts the access installation/
or the maintenance company Kumo solution or the maintenance request and the data maintenance engineer
purchases its annual license and its associated company sends an processing policy. or the maintenance
and makes a registration interfaces. The end access request to the company has access to
application to Hi Kumo PRO user does not need end customer via its all the operating data, for
through its Hitachi dealer. to have a license. PRO space* (*Access unrivalled service.
The dealer provides them may expire if the annual
with the documents needed license is not renewed).
for Hitachi to create their
PRO account.
Functions
Range of Air/Water heat pumps
- Start/Stop
- Temperature control
- Fan speed
- Choice of sweeping direction
- Weekly programming
- Error code display
Compatibility interface
Range of AIR/WATER heat pumps
The Hi Kumo solution lets you remotely manage the + storage water heaters
entire range of Hitachi Air/Air or Air/Water heat pumps or AHP-SMB-01 Hi-Box interface
thermodynamic tanks. A simple and user-friendly application +
brings real comfort to the end user. You think you forgot to turn ATW-TAG-02 Hi Kumo interface**
off your air-conditioning when you left? Do you want to cool +
down or heat up a little before you get home? It couldn’t be ATW-HCD-01 H-Link adapter
easier, with the Hi Kumo app!
** 1 max / Hi-Box interface
–
Yutaki S
NEW
Meets every requirement One of the best COPs Exclusive design to work
Wide range of rated power outputs from 4.3 kW to
24.00 kW in heating mode and 4.00 kW to 17.50 kW
on the market in the most extreme
in cooling mode. The Yutaki S range has one of the highest COP
ratings on the market: up to 5.25.
conditions
11 to 24 kW model have a three-phase power Its wide operating range allows the equipment to
supply. work in extreme outdoor conditions: from -25°C
It achieves the maximum energy rating of A+++,
which translates into less energy consumption and to 46°C.
Smaller dimensions bigger savings.
Its compact design and ease of installation make it Less consumption
ideal for small spaces. Models from 4.30 to 8.00 kW
will even fit in a kitchen cupboard.
New remote control A water outlet temperature of up to 60°C even at
included as standard -5°C outside, without the need for an additional
electrical heater, for significant savings.
An intuitive interface that can handle two zones,
and features an ambiance sensor to be
used as a separate modular thermostat.
RAS-4WH(V)NPE
RAS-5WH(V)NPE
RWM-2.0R1E RWM-4.0N1E RAS-2WHVRP1 RAS-6WH(V)NPE
RWM-2.5R1E RWM-5.0N1E RWM-8.0N1E RAS-2.5WHVRP1 RAS-8WHNPE
RWM-3.0R1E RWM-6.0N1E RWM-10.0N1E RAS-3WHVRP1 RAS-10WHNPE * with connections.
19
Yutaki S
Hydraulic features
Expansion vessel L 6 6 10
Water flow (min / rated / max) m3/h 0.5/0.77/1.9 0.6/1.03/2 0.6/1.29/2.1 1/1.89/2.9 1.1/2.41/3 1.2/2.75/3 2/3.44/4.5 2.2/4.13/4.6
Hydraulic heating connections (male/male valves supplied) inches 1” 1” 1/4 1” 1/4
Min. system water capacity L 28 38 46 55 76 79
Electrical features
Power supply - 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz or 400V / 3Ph / 50Hz 400V / 3Ph / 50Hz
Fuse size with backup heater A 16 32 -
SINGLE Cable width (mm²) / max. length (m) (2) - 3 x 2.5 / 14 3 x 6 / 28 -
PHASE
230V Fuse size with backup heater + A 32 50 -
immersion / Yutaki S Optional
Cable width (mm²) / max. length (m) (2) - 3 x 6 / 28 3 x 10 / 30 -
Fuse size with backup heater - - - - 16 16
THREE Cable width (mm²) / max. length (m) (2) - - - - 5 x 2.5 / 20 5 x 5 / 20
PHASE Fuse size with backup heater +
400V immersion/ Yutaki S Optional - - - - 32 32
Cable width (mm²) / max. length (m) (2) - - - - 5 x 6 / 20 5 x 10 / 20
Premium outdoor units RAS- RAS- RAS- RAS- RAS- RAS- RAS-8WHNPE RAS-
2WHVRP1 2.5WHVRP1 3WHVRP1 4WH(V)NPE 5WH(V)NPE 6WH(V)NPE 10WHNPE
Sound pressure level at 1m / Sound power dB(A) 46 / 61 47 / 63 54 / 69 49 / 64 50 / 65 50 / 67 59 / 73 60 / 74
Air flow rate m3/h 2526 2982 4800 5400 6000 7620 8040
Dimensions (H x L x D) mm 629 x 799 x 300 1380 x 950 x 370
Net weight kg 45 44 103 137 139
Operating ranges in Cooling / Heating / DHW mode °C +10~+46DB // -20~+25DB // -20~+35 +10~+46DB // -25~+25DB // -25~+35
Refrigeration characteristics
1/4” - 5/8”
Diameter of refrigerant pipes (Liq - Gas) inches 1/4” - 1/2”* 3 to 27m* 3/8” 5/8” 3/8” 1” 1/2” 1”
3/8” 5/8”
27 to 50m*
Min./max. length / max. level difference m 3 - 50 / 20 5 - 75 / 20 5 - 70 / 20
Initial pre-charged refrigerant / Additional load kg / g 1.2 for 10m 1.3 for 10m 1.3 for 10m 3.3 for 15m 3.4 for 15m / 60 5 for 15m / 65 5.3 for 15m
/m / 15 / 15 / 32 / 60 / 120
Refrigerant - R32 R410A
Compressor - SCROLL ROTARY SCROLL
Electrical features
Power supply - 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz or 400V / 3Ph / 50Hz 400V / 3Ph / 50Hz
SINGLE PHASE Fuse size A 16 16 16 32 - -
230V Cable width (mm²) / max. length (m) (2) - 3 x 2.5 / 28 3 x 2.5 / 24 3 x 4 / 21 3 x 10 / 30 - -
THREE PHASE Fuse size A - - - 16 16 25 25
400V Cable width (mm²) / max. length (m) (2) - - - - 5 x 4 / 16 5 x 4 / 16 5 x 6 / 26
Int./Ext. connection (shielded) mm² 2 x 0.75 2 x 0.75
(1)
Non-regulated seasonal energy efficiency, Keymark-certified. (2) Data given for reference purposes only. Compliant with the applicable electrical standards.
(V) = single. * 2/2.5/3HP R32 models have different diameters for the cooling gas pipes, cooler connection groups, and indoor units. For that reason, use the adapters provided with the outdoor unit. Refer to the table page 7.
20
Internal design
Yutaki S
Pressure switch
Air purge valve
Expansion Electric
vessel enclosure
High-efficiency
pump
Expansion
valve
Plate heat
exchanger
D HW
8 8
9 9
7 7
Cold 3
water Cold
water
2
3
5
4 5
4
1 10
9
1
1
8
1
4 6 8
6
1 1 1
Wired remote control Front panel Wired temperature sensor On / Off wireless
PC-ARFH2E Use if moving the remote control in ATW-ITS-01 thermostat
Included. the environment.
ATW-RTU-04
ATW-FCP-01
1 1
Intelligent wireless Intelligent wireless Auxiliary output box Hi-Box: Hi Kumo and
thermostat thermostat 4 ports available: operation, alarm, Hi Kumo PRO home
cooling, heat-OFF.
Circuit 1. Circuit 2.
ATW-AOS-02
automation boxes
ATW-RTU-07 ATW-RTU-06 AHP-SMB-01
(for more, see p.16-17)
10 2
Usage meter (RT2012) Reversible kit Cascade controller 2-zone mixing kit -
Schneider® brand. E quipment required to run in cooling Manage a cascade up to 8 Yutaki wall mounted
Not sold by Hitachi. mode. models from the same range and
This accessory is essential if you want
ATW-CKS-01 (Yutaki S Mini 2 / 2.5 / 3 HP) with the same power output (single/
to maintain 2 distinct temperature
three-phase).
ATW-CKS-02 (Yutaki S Medium 4 / 5 / 6 HP) settings.
ATW-CKS-03 (Yutaki S Power 8 / 10 HP) ATW-YCC-03
ATW-2TK-07
3 4 5 6
7 8 9
–
Yutaki S Combi
Yutaki S Combi
NEW
included as standard
An intuitive interface that can handle two
zones, and features an ambiance sensor to
be used as a separate modular thermostat.
1,788 1,380
(1,889)*
629
598 300 370
RWD-2.0RW1E
RWD-2.5RW1E RAS-2WHVRP1 RAS-4WH(V)NPE
RWD-3.0RW1E RWD-5.0NW1E RAS-2.5WHVRP1 RAS-5WH(V)NPE
RWD-4.0NW1E RWD-6.0NW1E RAS-3WHVRP1 RAS-6WH(V)NPE * with connections.
25
Yutaki S Combi R32 REFRIGERANT R410A REFRIGERANT
Model YUTAKI S COMBI YUTAKI S COMBI YUTAKI S COMBI YUTAKI S COMBI YUTAKI S COMBI YUTAKI S COMBI
4.3kW 6kW 8kW 11kW 14kW 16kW
Performance, heating
Min./rated/max. heating capacity (7°C outside. / 35°C water) kW 1.85 / 4.3 / 6.5 1.85 / 6 / 8.6 2.1 / 8 / 11 4.3 / 11 / 15.2 4.8 / 14 / 16.7 5.5 / 16 / 17.8
Rated/max. power heating (-7°C outside / 35°C water) kW 4.5 / 5.3 5.3 / 6.2 5.8 / 7.5 9.7 / 10.6 11.5 / 12 12 / 13
Rated/max. power heating (-7°C outside / 45°C water) kW -/5 - / 5.8 - / 6.67 10 / 10 11 / 11.6 11.5 / 12.5
Rated/max. power heating (-7°C outside / 55°C water) kW 4 / 4.2 4.7 / 5 5 / 5.5 8.7 / 9.7 9.7 / 11.2 10.5 /12
Rated power input for heating (7°C outside / 35°C water) kW 0.77 1.21 1.6 2.2 2.97 3.5
COP (7°C outside / 35°C water) in accordance with EN14511 - 5.25 4.8 4.6 5 4.71 4.57
SCOP average climate 35°C / 55°C in accordance with EN14825 - 4.6 / 3.4 4.5 / 3.25 4.5 / 3.2 4.8 / 3.5 4.48 / 3.43 3.9 / 3.23
Seasonal heating energy efficiency ηs (35°C) Single/Three(1) % 181 177 177 187 / 186 175 / 174 153 / 152
Seasonal heating energy efficiency ηs (55°C) Single/Three(1) % 130 127 125 136 / 135 133 / 132 125 / 125
Energy rating 35°C / 55°C - A+++ / A++ A+++ / A++ A++ / A++
Temperature range of water outlet (heating mode) °C 20 / 60°C 20 / 60°C
Max. temperature at the water outlet in thermodynamic-only °C 60°C up to -5 °C outside 60°C up to -10 °C outside
mode
DHW performance
DHW COP in accordance with EN16147 - 3.20 3.10
Seasonal energy efficiency nwh % 130 127
DHW energy rating - A+ A+
Temperature range of water outlet (DHW mode) °C 30 / 75°C 30 / 75°C
Hydraulic features
Expansion vessel L 6 6
Water flow (min / rated / max) m3/h 0.5 / 0.77 / 1.8 0.6 / 1.03 / 1.9 0.6 / 1.29 / 1.9 1 / 1.89 / 2.7 1.1 / 2.41 / 2.8 1.2 / 2.75 / 2.8
Hydraulic connections for heating inches 1” 1”
(male/male valves supplied)
Hydraulic connections for DHW inches 3/4” 3/4”
Min. system water capacity L 28 38 46 55
Electrical features
Power supply - 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz or 400V / 3Ph / 50Hz
Refrigeration characteristics
1/4” - 5/8”
Diameter of refrigerant pipes (Liq - Gas) inches 1/4” - 1/2”* 3 to 27m* 3/8” 5/8”
3/8” 5/8”
27 to 50m*
Min./max. length / max. level difference m 3 - 50 / 20 5 - 75 / 20
Initial pre-charged refrigerant / Additional load kg / g 1.2 for 10m / 15 1.3 for 10m / 15 1.3 for 10m / 32 3.3 for 15m / 60 3.4 for 15m / 60
/m
Refrigerant R32 R410A
Compressor SCROLL ROTARY SCROLL
Electrical features
Power supply 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz or 400V / 3Ph / 50Hz
SINGLE PHASE Fuse size A 16 32
230V Cable width (mm²) / max. length (m)(2) - 3 x 2.5 / 28 3 x 2.5 / 24 3 x 4 / 21 3 x 6 / 30
THREE PHASE Fuse size A - - - 16
400V Cable width (mm²) / max. length (m)(2) - - - - 5 x 4 / 16
Int./Ext. connection (shielded) mm² 2 x 0.75 2 x 0.75
(1)
Non-regulated seasonal energy efficiency, Keymark-certified. (2) Data given for reference purposes only. Compliant with the applicable electrical standards. (V) = single.
* 2/2.5/3HP R32 models have different diameters for the cooling gas pipes, cooler connection groups, and indoor units. For that reason, use the adapters provided with the outdoor unit. Refer to the table on page 7.
26
Internal design
Yutaki S Combi
Pressure
gauge
Expansion
vessel
Electric
Electric heater enclosure
Immersion
heater
DHW
Expansion valve
Filter ball
High-efficiency pump
Plate heat
exchanger
27
60°C 35°C
1 1 1
35°C
DHW DHW 4
4 3
1-circuit heating with radiators or 2-circuit heating with radiator circuits and
underfloor heating + DHW underfloor heating + DHW
1 1 1
1 1
Wireless intelligent Wireless intelligent Auxiliary output box Hi-Box: Hi Kumo and
thermostat thermostat for 2nd circuit 4 ports available: operation, alarm, Hi Kumo PRO home
cooling, heat-OFF.
Circuit 1. Circuit 2.
ATW-AOS-02
automation boxes
ATW-RTU-07 ATW-RTU-06 AHP-SMB-01
(for more, see p.16-17)
3 4 5 6
2-zone mixing kit - Aquastat, floor-mounted 3-way directional Differential pressure valve
wall mounted This accessory is essential for floor- inversion valve This accessory ensures a constant
mounted heaters (DTU 65-14). flow through the heat pump
This accessory is essential if DHW and swimming pool
ATW-AQT-01 condenser.
you want to maintain 2 distinct applications.
temperature settings. ATW-DPOV-01
ATW-3WV-01
ATW-2TK-07
7 8 9
–
Yutaki S80
R410A - H2O
This minimizes consumption and guarantees
uninterrupted comfort. (Fig. 1)
R134A - H2O
Air - R410A
requirement Air
R410A R134A
Meeting all market needs, by adding a separate
tank as big as 3,000 litres to the Yutaki S80 range,
the system can provide plenty of DHW to go
around in shared residential buildings.
Fig. 2
751
(802)* 1,380
623
600 370
950
RWH-4.0VNFE RAS-4WH(V)NPE
RWH-5.0VNFE RAS-5WH(V)NPE
RWH-6.0VNFE RAS-6WH(V)NPE * with connections.
31
Yutaki S80
R410A + R134A REFRIGERANT
Model YUTAKI S80 11kW YUTAKI S80 14kW YUTAKI S80 16kW
Performance, heating
Min./rated/max. heating capacity (7°C outside. / 35°C water) kW 11 / 15.2 14 / 16.7 16 / 17.8
Rated/max. power heating (-7°C outside / 35°C water) kW 9.7 / 10.6 11.5 / 12.2 12.1 / 13
Rated/max. power heating (-7°C outside / 45°C water) kW 11 / 12.5 14 / 14.5 16 / 16
Rated/max. power heating (-7°C outside / 55°C water) kW 11 / 12.5 14 / 14.5 16 / 16
Rated power input for heating (7°C outside / 35°C water) kW 2.2 2.97 3.5
COP (7°C outside / 35°C water) in accordance with EN14511 - 5 4.71 4.57
SCOP average climate 35°C / 55°C in accordance with EN14825 - 4.75 / 3.63 4.43 / 3.35 3.88 / 3.23
Seasonal heating energy efficiency ηs (35°C) Single/Three(1) % 187 / 183 174 / 171 152 / 150
Seasonal heating energy efficiency ηs (55°C) Single/Three(1) % 142 / 140 131 / 129 126 / 125
Energy rating 35°C / 55°C - A+++ / A++ A++ / A++
Temperature range of water outlet (heating mode) °C 20 / 80°C
Max. temperature at the water outlet in thermodynamic-only °C 80°C down to -20°C outside
mode
Hydraulic features
Expansion vessel L 12
Water flow (min / rated / max) m3/h 1 / 1.89 / 2.8 1.1 / 2.41 / 3.2 1.2 / 2.75 / 3.2
Hydraulic heating connections (male/male valves supplied) inches 1” 1/4
Min. system water capacity L 40 50 50
Refrigeration characteristics
Refrigerant - R134A
Refrigerant charge kg 1.9
Compressor - SCROLL
Electrical features
Power supply - 230V / 1Ph / 50Hz or 400V / 3Ph / 50Hz
Refrigeration characteristics
Diameter of refrigerant pipes (Liq - Gas) inches 3/8” 5/8”
Min./max. length / max. level difference m 5 - 75 / 20
Initial pre-charged refrigerant / Additional load kg / g 3.3 for 15m / 60 3.4 for 15m / 60
/m
Refrigerant - R410A
Compressor - SCROLL
Electrical features
Power supply - 230V / 1Ph / 50Hz or 400V / 3Ph / 50Hz
(1)
Non-regulated seasonal energy efficiency, Keymark-certified. (2) Data given for reference purposes only. Compliant with the applicable electrical standards. (V) = single.
32
Internal design
Yutaki S80
Filter ball
Solenoid
valves
Expansion
vessel
High-efficiency Expansion
pump valve
33
Hydraulic setups
Yutaki S80
1 80°C 1 80°C
12
5 5
1 1
1
80°C 35°C
1 1
11 1
9
3 1 1
1
8
2
Yutaki S80
hydraulic controls and accessories
Yutaki S80
1 1 1
1 1
Wireless intelligent Wireless intelligent Auxiliary output box Hi-Box: Hi Kumo and
thermostat thermostat for 2nd circuit 4 ports available: operation, alarm, Hi Kumo PRO home
cooling, heat-OFF.
Circuit 1. Circuit 2.
ATW-AOS-02
automation boxes
ATW-RTU-07 ATW-RTU-06 AHP-SMB-01
(for more, see p.16-17)
11 2 3
Usage meter (RT2012) Cascade controller 2-zone mixing kit - Aquastat, floor-mounted
Schneider® brand. Manage a cascade up to 8 Yutaki wall mounted This accessory is essential for floor-
Not sold by Hitachi. models from the same range and mounted heaters (DTU 65-14).
This accessory is essential if you want
with the same power output (single/ ATW-AQT-01
to maintain 2 distinct temperature
three-phase).
settings.
ATW-YCC-01
ATW-2TK-07
AEM-EM-2105 (single-phase)
For three-phase, please contact us
4 5 6 7
3-way directional Differential pressure valve Hydraulic separator DHW storage tank
inversion valve This accessory ensures a constant for heat pump Stainless steel tank.
flow through the heat pump
DHW and swimming pool This accessory hydraulically A range of tanks and buffer vessels
condenser.
applications. separates the transmitter and boiler are available. Tanks from 150l to 300l
ATW-DPOV-01 network from that of the heat pump. and buffer vessels from 60l.
ATW-3WV-01
ATW-HSK-01
8 9 10 12
–
Yutaki M
No refrigerant connections:
Yutaki M
Outdoor units
1,380
629
300 370
1,248 1,252
RASM-4(V)NE
RASM-2VRE RASM-5(V)NE
RASM-3VRE RASM-6(V)NE
37
Yutaki M
R32 REFRIGERANT R410A REFRIGERANT
Model YUTAKI M 4.3kW YUTAKI M 8kW YUTAKI M 11kW YUTAKI M 14kW YUTAKI M 16kW
Performance, heating
Min./rated/max. heating capacity (7°C outside. / 35°C water) kW 1.85 / 4.3 / 6.5 2.1 / 8 / 11 11 / 15.2 14 / 16.7 16.0 / 17.8
Rated/max. power heating (-7°C outside / 35°C water) kW 4.5 / 5.3 5.8 / 7.5 9.7 / 10.6 11.5 / 12 12 / 13
Rated/max. power heating (-7°C outside / 45°C water) kW /5 / 6.67 10 / 10.3 11 / 11.6 11.5 / 12.5
Rated/max. power heating (-7°C outside / 55°C water) kW 4 / 4.2 5 / 5.5 8.7 / 9.8 9.7 / 11.2 10.5 / 12
Rated power input for heating (7°C outside / 35°C water) kW 1 1.94 2.2 2.97 3.5
COP (7°C outside / 35°C water) in accordance with EN14511 - 5.25 4.6 5 4.71 4.57
SCOP average climate 35°C / 55°C in accordance with EN14825 - 4.73 / 3.48 4.55 / 3.25 4.8 / 3.5 4.48 / 3.43 3.9 / 3.23
Seasonal heating energy efficiency ηs (35°C) Single/Three(1) % 181 177 187 / 186 175 / 174 153 / 152
Seasonal heating energy efficiency ηs (55°C) Single/Three(1) % 133 125 136 / 135 133 / 133 125 / 125
Energy rating 35°C / 55°C - A+++ / A+++ A+++ / A++ A++ / A++
Temperature range of water outlet (heating mode) °C 20 / 60°C 20 / 60°C
Max. temperature at the water outlet in thermodynamic-only °C 60°C up to -5°C outside 60°C up to -10°C outside
mode
Hydraulic features
Expansion vessel L 6 6
Water flow (min / rated / max) m3/h 0.5 / 0.77 / 1.9 0.6 / 1.29 / 2.1 1 / 1.89 / 2.8 1.1 / 2.41 / 3 1.2 / 2.75 / 3
Water heating connections (valves not supplied) inches 1” 1”1/4
Min. system water capacity L 28 38 46 55
Electrical features
Power supply - 230V / 1Ph / 50Hz 230V / 1Ph / 50Hz or 400V / 3Ph / 50Hz
Fuse size A 16 16 32 32 32
SINGLE Cable width (mm²) / max. length (m) (2) - 3 x 2.5 / 14 3 x 4 / 16 3 x 6 / 25
PHASE
230V Fuse size with immersion / Yutaki M Option A 32 32 50 50 50
Cable width (mm²) / max. length (m) (2) - 3 x 6 / 28 3 x 10 / 28
Fuse size - - - 16 16 20
THREE Cable width (mm²) / max. length (m) (2) - - - 5x4 5x6
PHASE
400V Fuse size with immersion / Yutaki M Option - - - 32 32 32
Cable width (mm²) / max. length (m) (2) - - - 5x6 5 x 10
Refrigerant Characteristics
Refrigerant load kg 1.2 1.3 2.8 3.1 3.1
Refrigerant - R32 R410A
Compressor SCROLL ROTARY SCROLL SCROLL SCROLL
(1)
Non-regulated seasonal energy efficiency, Keymark-certified. (2) Data given for reference purposes only. Compliant with the applicable electrical standards. (V) = single.
38
Internal design
Yutaki M
Electric enclosure
Plate heat
exchanger
Expansion
valve
Expansion
vessel
High-efficiency
pump
39
Hydraulic diagrams
Yutaki M
60°C 35°C
1 60°C 35°C
1 1
DHW DHW
9 9
10 1 1
10
8 8
4
Cold Cold
water water
9 4
9
3
5 5
2
2
1 zone of radiators or underfloor heating 2 zones with radiator circuits and underfloor
with or without DHW heating with or without DHW
10
9
7
1 1 1 1
Wireless intelligent Auxiliary output box Hi-Box: Hi Kumo and Somfy® home-
thermostat for 2nd circuit 4 ports available: operation, alarm, Hi Kumo PRO home automation box
cooling, heat-OFF.
Circuit 2.
ATW-AOS-02
automation boxes 1811527
ATW-RTU-06 AHP-SMB-01
(for more, see p.16-17)
1 1 2
3 4 5 6
2-zone mixing kit - Aquastat, floor-mounted 3-way directional Differential pressure valve
wall mounted This accessory is essential for floor- inversion valve This accessory ensures a constant
mounted heaters (DTU 65-14). flow through the heat pump
This accessory is essential if DHW and swimming pool
ATW-AQT-01 condenser.
you want to maintain 2 distinct applications.
temperature settings. ATW-DPOV-01
ATW-3WV-01
ATW-2TK-07
7 8 9 10
IRE
Regulations & incentives
Air Source Heat Pumps have become a popular choice
in new build properties. This is due to the introduction
of tighter regulations towards NZEB (Nearly Zero Energy
Building) for new build properties, which has resulted in
the effective phasing out of fossil fuels as a heat source
and the introduction of renewable energy heat solutions
such as Air Source Heat Pumps.
The Yutaki range complies with Part L building regulations for heating and for hot
water solutions, and the Yutaki S Combi and Yutaki M units are tested to EN16147 as
a packaged solution and therefore pass regulations for heating and hot water.
Yutaki also complies with the Energy Related Products (ErP) directive.
For more information please contact us.
Call us on: + 44 (0)203 901 0912 - Business hours: Mon - Fri 9am - 5pm, or
Email: [Link]@[Link]
For more information on Yutaki, please visit [Link]
or for any schematics, please visit [Link]
and for product selection software, please visit [Link]
UK
Regulations & incentives
To ensure qualification of the BUS, the product and the installer need to be
Microgeneration Certification Scheme (MCS) approved. The entire Hitachi Yutaki
range is MCS approved, so they all qualify for Government Grant schemes.
Yutaki also complies with the Energy Related Products (ErP) directive.
For more information please contact us.
Call us on: + 44 (0)203 901 0912 - Business hours: Mon - Fri 9am - 5pm, or
Email: [Link]@[Link]
For more information on Yutaki, please visit [Link]
or for any schematics, please visit [Link]
and for product selection software, please visit [Link]
Email: [Link]@[Link]
Tel.: 020 3901 0912 [Link]
The specifications of this catalogue may change without prior notice to allow
Hitachi Cooling & Heating to incorporate the latest innovations for its customers.
The information contained in this catalogue is merely informative.
Hitachi Cooling & Heating declines any responsibility in the broadest sense, for
damage, direct or indirect, arising from the use and / or interpretation of the
recommendations in this catalogue.
Communication interfaces like KNX and Modbus enrich the functionality of heat pump systems by integrating them into broader smart home or building management systems. They allow for remote control and monitoring, which can lead to optimized energy use and increased user comfort. For example, integrating with KNX can help users set schedules and automate responses to environmental changes, thereby potentially enhancing energy efficiency . Modbus interfaces provide similar benefits in facilities that require coordinated control across multiple devices, promoting seamless interaction and data exchange .
Sound levels directly impact the suitability of heat pump systems in residential areas; lower noise levels are preferable to meet comfort requirements. Indoor unit sound levels ranging from 37 to 47 dB(A) and outdoor levels up to 74 dB(A) affect community noise regulations and user comfort. Units with higher sound pressure, especially in densely populated residential spaces, may require additional noise mitigation solutions, impacting the choice of a particular heat pump model depending on sensitivity to background noise .
Reversible heating-cooling models offer substantial advantages for year-round climate control by using a single system capable of swapping between heating in the winter and cooling in the summer. This integrated approach eliminates the need for separate systems, leading to space and cost savings. Their flexible operating ranges, such as rated/max cooling power (4 to 20.6 kW), offer efficient adaptation to seasonal temperature variations. The ability to reverse operation for cooling broadens system applications and ensures usability regardless of outdoor temperature conditions .
The dimensions and weight of indoor units correlate with their performance capacities as larger and heavier units generally offer higher performance capabilities. For instance, an indoor unit weighing 62 kg with dimensions 890 x 670 x 370 mm has a maximum water flow up to 4.6 m3/h and is equipped with a larger backup heater capacity of 9 kW. In contrast, smaller units with less weight have lower capacities accordingly, aligning with lower water flow and heating capacities. This correlation is rooted in the ability of larger units to house more robust internal components necessary for greater efficiencies .
Temperature ranges for water outlets and ambient conditions are pivotal in dictating the energy efficiency and performance of heat pump systems. Outlet temperature ranges (20/60°C) allow systems to provide efficient heating across different climates. The ability to maintain maximum outlet temperatures even at low ambient temperatures (e.g., 60°C at -5°C) ensures system efficacy in cold environments; it enhances the Seasonal Coefficient of Performance (SCOP) leading to energy savings. This flexibility supports consistent service across varying climate zones, demonstrating the system’s effectiveness in maintaining efficiency under diverse external temperatures .
Heat pump systems incorporate several design features that enhance their operational flexibility and efficiency across climates. Adjustable water outlet temperature range (20/60°C) allows adaptation to seasonal requirements. The capability to operate with cooling models and an extensive rated/max cooling power range (4 to 20.6 kW) enables the systems to offer both heating and cooling. Further, reversible models with efficient EER values, reaching up to 4, contribute to flexibility. These systems can accommodate various temperature ranges effectively by design, such as being operational down to -20°C in heating mode .
The Seasonal Heating Energy Efficiency (ηs) is affected by the temperature set for either 35°C or 55°C. For single-phase systems, ηs tends to be higher compared to three-phase systems at 35°C, but they become comparable at 55°C. Specifically, ηs for single systems is 181% at 35°C and 133% at 55°C. In contrast, for three-phase systems, ηs at 35°C ranges from 174% to 152% and for 55°C from 133% to 116%. These variations suggest that ηs is influenced by the system's phase configuration and the target operating temperature .
Power supply and electrical specifications affect both installation complexity and operational flexibility. Systems designed for multiple phase options (e.g., 230V single-phase or 400V three-phase) allow for greater adaptability to local grid standards across regions, simplifying installation. The need for varying fuse sizes (e.g., 16 A or 32 A) and appropriate cable widths ensures compatibility with regional electrical infrastructure. These specifications influence where and how systems can be effectively installed, impacting the broader functional range and cost-effectiveness of heat pump systems across different markets .
Including a backup electrical heater in heating systems can increase overall energy consumption, as these heaters are used when ambient conditions are insufficient for heat pump operation alone. The electrical heater's operation requires additional power input, for example, heaters can range from 3 kW to 9 kW based on the system size, impacting efficiency negatively when in use. The system's reliance on the electrical heater and its capacity can directly affect the Seasonal Coefficient of Performance (SCOP) and energy efficiency ratios. The provision for phases indicates higher fuse sizes required, such as 32 A for larger systems, which reflects higher potential energy usage .
The expansion vessel and water flow specifications are crucial for maintaining system stability and efficiency in heat pump systems. The expansion vessel, with capacities like 6 L to 10 L, helps to accommodate the thermal expansion of water, preventing excessive pressure build-up. Proper water flow rates, with ranges such as 0.5 to 4.13 m3/h, ensure adequate heat exchange and system efficiency. These components together stabilize the hydraulic system, enhancing performance across varying load conditions and promoting longevity by reducing stress on piping and other components .