Grundfosliterature 6153682
Grundfosliterature 6153682
E-Box 500
Ethernet communication for SMART Digital S DDA (up to 30 l/h)
E-Box 500
Other languages
[Link]
Table of contents
E-Box 500
English (GB)
Installation and operating instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
Čeština (CZ)
Montážní a provozní návod . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Deutsch (DE)
Montage- und Betriebsanleitung . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Dansk (DK)
Monterings- og driftsinstruktion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Español (ES)
Instrucciones de instalación y funcionamiento. . . . . . . . . . . . . . . . . . . . . . . . . . . . 24
Suomi (FI)
Asennus- ja käyttöohjeet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Français (FR)
Notice d'installation et de fonctionnement. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35
Italiano (IT)
Istruzioni di installazione e funzionamento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Polski (PL)
Instrukcja montażu i eksploatacji. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Português (PT)
Instruções de instalação e funcionamento . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52
Română (RO)
Instrucţiuni de instalare şi utilizare . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58
Русский (RU)
Паспорт, Руководство по монтажу и эксплуатации . . . . . . . . . . . . . . . . . . . . . . . 63
Svenska (SE)
Monterings- och driftsinstruktion . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 69
中文 (CN)
安装和使用说明书 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74
日本語 (JP)
取扱説明書. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79
한국어 (KO)
설치 및 작동 지침 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 84
Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 89
Declaration of conformity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91
3
English (GB)
4. Installation . . . . . . . . . . . . . . . . . . 5
5
4.1 Installation kit . . . . . . . . . . . . . . . . . 5
4.2 Electrical connection . . . . . . . . . . . . . 5
4.3 Mechanical installation . . . . . . . . . . . . 7 H2
H3
5. Technical data . . . . . . . . . . . . . . . . 7 H1
5.1 Dimensions . . . . . . . . . . . . . . . . . . 8
H7
6. Cleaning . . . . . . . . . . . . . . . . . . . 8 H6
H4 6
1. General information H5
Read this document before you install the
product. Installation and operation must H9
comply with local regulations and accepted
H8
codes of good practice.
TM069640
1 2 3 4
WARNING
If these safety instructions are not
observed, it may result in personal injury.
E-box overview
4
English (GB)
Pos. Description 4. Installation
H4 Data activity LED for RJ45 connector 1
4.1 Installation kit
H5 Link LED for RJ45 connector 1 The E-Box package contains these parts:
H6 Data activity LED for RJ45 connector 2 • E-Box equipped with CIM module
H7 Link LED for RJ45 connector 2 • Installation and operating instructions for the E-
Box
Red/green status LED for Ethernet • Installation and operating instructions for the CIM
H8
communication module
Red/green LED for internal communication • CD-ROM (software, functional profiles, installation
H9 between the CIM 500 and the Grundfos and operating instructions).
product
Keep the CD-ROM and the installation and
operating instructions so that they are
* Depending on local network installation
Note easy to find when the E-Box with CIM
module has to be integrated into the main
3.3 Symbols on the product communications network.
Warning
Before beginning the electrical connection,
Functional earth terminal. make sure that the power supply of the
DDA dosing pump has been switched off,
and that it cannot be accidentally switched
on.
3.4 Nameplate
Warning
1 2 3 4 5
To ensure enclosure class IP65 / NEMA
4X, all unused connections have to be
fitted with a blind plug!
4.
Caution
Connect E-box to power supply only via
the SMART digital S DDA pump using the
pre-assembled plug!
Pos. Description
To ensure a stable and reliable
1 Type designation communication, the cable screen for
GENIbus connection must always be
2 Model
Caution connected to the earth clamp. This is pre-
3 Voltage assembled by Grundfos.
4 Power consumption See fig. E-box overview, pos. 4.
Do not make any changes!
5 Enclosure class
6 Country of origin Related information
7 Marks of approval 3.2 Product overview
4.2.1 Connection of Ethernet
The CIM 500 is designed for flexible network
installation. The built-in two-port switch makes it
possible to daisy chain from product to product
without the need of additional Ethernet switches. The
5
English (GB)
last product in the chain is only connected to one of 4. If necessary, connect earth conductor to functional
the Ethernet ports. Each Ethernet port has its own earth terminal (8) at earth connection (3) and
MAC address. tighten clamp (9).
5. Fit housing cover and tighten screws.
1 • Make sure that the gasket is positioned
correctly.
CIM CIM CIM
500 500 500
The module comes with fixed IP address:
CIM [Link]
500 Note
The IP address settings can be changed
with the built-in web server.
Example of industrial Ethernet network
For further information (e.g. connection to web
server) see installation and operating instructions of
Pos. Description the CIM 500 module.
1 Ethernet switch Related information
• CIM 500 Ethernet module Installation and
1. Remove cover from E-Box. Operating Instructions
4.2.2 Selection of industrial Ethernet protocol
The industrial Ethernet protocol can be set via the
rotary switch. See fig. Connection of Ethernet, pos. 6.
6
Pos. Description
0 PROFINET IO (factory setting)
1
1 Modbus TCP
2
Reserved. LED1 will be permanently red to
5...E
indicate an invalid configuration.
Rotary switch for selection of industrial 4.2.3 Connection of power supply and GENIbus
6
Ethernet protocol. Prior to connection of power supply and GENIbus,
7 Earth clamps for cable screens execute the mechanical installation.
8 Functional earth terminal 1. Switch off the power supply of the DDA dosing
pump (pos. 1).
9 Earth clamp
• Wait for approx. 20 seconds before executing
2. Connect Ethernet cables with RJ45 plugs to the next step.
connections (1), (2). 2. Remove protective cap from BUS input of the
• Depending on the local network installation, pump.
one or two cables can be connected. 3. Connect plug (pos. 4) thoroughly to BUS input of
3. Connect cable screens to earth via the earth the pump.
clamps (7).
6
English (GB)
•Insert locking device (pos. 5) at pump housing
4 (detail 2).
1
2. Tighten screw (pos. 4) to lock connection (detail
3).
TM048442
4
2
TM048438
plug, see installation and operating
Note instructions of the DDA dosing pump.
The functional profile can be found on the
product CD delivered with the E-Box. Mounting pump on E-Box
Related information
For horizontal installation, the E-Box can be mounted
4.3 Mechanical installation on the mounting plate of the DDA dosing pump.
TM048437
or tank mounted).
5. Technical data
7
English (GB)
* Only from SMART digital S DDA dosing pump via pre-assembled plug connection
Dimensional sketch
6. Cleaning
The E-Box must only be cleaned with a dry and clean
cloth.
8
Declaration of conformity
Declaration of conformity
89
Declaration of conformity
Jimm Feldborg
Head of PD IND
Grundfos Holding A/S
Poul Due Jensens Vej 7
8850 Bjerringbro, Denmark
Person authorised to compile technical file and
empowered to sign the EU declaration of conformity.
90
Declaration of conformity
Declaration of conformity
UK declaration of conformity
We, Grundfos, declare under our sole responsibility
that the products to which the declaration below
relates, are in conformity with UK regulations,
standards and specifications to which conformity is
declared, as listed below:
Valid for Grundfos products:
E-Box 500
Jimm Feldborg
Head of PD IND
Grundfos Holding A/S
Poul Due Jensens Vej 7
8850 Bjerringbro, Denmark
Manufacturer and person empowered to sign the UK
declaration of conformity.
10000141460
91
Doc-Ukrainian-E-Box 500
92
Bjerringbro, 04.03.2022
Jimm Feldborg
Head of PD IND
Grundfos Holding A/S
Poul Due Jensens Vej 7
8850 Bjerringbro, Denmark
GB: Manufacturer and person empowered to sign the Ukrainian declaration of conformity
UA: Виробник та особа, уповноважена підписати українську декларацію відповідності
[10000435788]
93
Grundfos companies
[Link]
04.2022
Trademarks displayed in this material, including but not limited to Grundfos and the Grundfos logo, are registered trademarks owned by The Grundfos Group. © 2022 Grundfos Holding A/S, all rights reserved.