The document provides design calculations for the foundation of a boundary wall. It calculates loads and moments on the foundation from the self-weight of materials and wind loads. It then checks that the foundation design is adequate to resist base pressure, overturning, and sliding. Reinforcement and brickwork stresses are also checked. The foundation depth and reinforcement provided are determined to be adequate based on the calculated bending moment and shear. Tensile stresses in the brickwork are found to satisfy code requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (2 votes)
758 views2 pages

Boundry Wall Design (B)

The document provides design calculations for the foundation of a boundary wall. It calculates loads and moments on the foundation from the self-weight of materials and wind loads. It then checks that the foundation design is adequate to resist base pressure, overturning, and sliding. Reinforcement and brickwork stresses are also checked. The foundation depth and reinforcement provided are determined to be adequate based on the calculated bending moment and shear. Tensile stresses in the brickwork are found to satisfy code requirements.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Design of Boundary wall with Strip foundation‐pillar location

Sno Description = Value Units


1 Net SBC of soil at fdn depth = 30.5 Kn/sqm
1 Height of the boudnary wall = 2.5 m
2 Grade of concrete = 20 N/Sqmm
3 Grade of steel = 500 N/Sqmm
4 Grade of cement mortar for brickwork =
5 Wind speed = 47 m/s
6 Value of K1 = 0.71
7 Value of K2 = 0.8 Terrain cat 4
8 Value of K3 = 1
9 Value of K4 = 1
10 Vz = Vb x k1 x k2 xk3 xk4 = 26.696
11 Pz= 0.6 x Vz x vz = 428 N/m2
12 Pz in KN/sqm = 0.428 KN/m2
13 Density of soil = 18 kn/cum
13 Density of brickwork = 20 kn/cum
14 Density of RCC = 25 kn/cum
15 Thickness of Brickwork = 0.23 m
16 width of pillar = 0.3 m 0.3
17 Depth of the foundation = 1.5 m
18 Width of foundation = 1.3 m
19 Thickness of foundation = 0.3 m
20 Width of plinth beam = 0.3 m
21 Thickness of beam = 0.3 m
2.5
Loads and moments calculation
A) BASE PRESSURE CHECK
Moment due to wind load is considered pillar design due to H/L ratio
=1, where H=2.5m and Length between the piers =2.5m
weight of Brickwork/m = 20.4 KN/m NGL
Weight of plinth beam/m = 2.25 KN/m
weight of soil above footing/m = 21.6 KN/m 0.3
1.2
weight of foundation/m = 7.5 KN/m
0.3
Total dead weight of BW/m = 51.75 KN/m
Moment due to wind load = 7.36 KN‐m/m
0.3
P/A = 39.808 KN/sqm
M/z = 26.12 KN/sqm 0.5 0.3 0.5
P/A+M/Z ( Max pressure) = 65.92 KN/sqm 1.3
P/A‐M/Z ( Min pressure) shall not be < 0 = 13.69 KN/sqm span of pillar = 2.5
Gross SBC = 57.5 KN/sqm
Check for base pressure is FAIL
B) Overturning check
Total OTM due to wind @ Base = 7.36
The total RM (P X fdn width/2) = 33.64
Factor of safety RM/OTM = 4.57
Check for Over turning is OK
C) Check for Sliding
Total horizontal wind force @ fdn = 1.07 Kn/m
Total resisiting force from the wt of fdn = 15.525 Kn/m
Factor of safety = 14.51
Check for Sliding is OK
D) Design of foundation
Max pressure of the foundation = 65.92 Kn/m

Page 1 of 2
Design of Boundary wall with Strip foundation‐pillar location
Sno Description = Value Units
Factored pressure from the foundation = 98.89 Kn/m
Max bending moment at the face of beam = 49.44 Kn‐m/m
Depth required as per BM = 117 mm
Depth provided in mm is = 300 ok
Effective depth = 250 mm
2 2
MU / ( b X d ) = 0.79 N / MM
Shear at above point = 49 KN/m
2
PU / ( b X d ) = 0.20 N / MM
2
Allowable shear stress = 0.28 N / MM
Shear stress of the footing is OK
% of Steel as per Table ‐ 3 of SP : 16 = 0.189
% of Steel as per Table ‐ 19 of IS: 456 = 0.120
Required Area of Steel for Maximum of above = 4.72 Sq.CM
Min. Requirement as 0.12% of Gross Area = 3.60 Sq.CM
Max. of above = 4.72 Sq.CM
Reinforcement Dia Proposed = 10 MM
Spacing Proposed as per above & to Table‐96 = 100 MM
Provided Area of Steel as per Table‐96 = 7.86 Sq.CM
Provide 10 Dia @ 100 C/C in both ways and ok
E) Checking of the Brickwork tensile stress
H/L ratio =1
Since H/L ratio exceeds 0.3 and panel is free at top and supported on
other 3 edges, maximum bending will be in the horizontal direction,
and by interpolation from Table 12 of the Code it will be:
Max moment = PL/12
0.083 x P x H X L X L =
= 555 n‐m
Section Modulus ‐ bd^2/6‐2.5x 0.23^2/6 = 0.022 m3
Tensile stress‐ M/z = 25182 n/m2
= 0.025 N/mm2
Allowable tensile stress for 1:6 mortar = 0.05 N/mm2
Hence the allowable stress of brickwork is ok