Cable and Pipe Sealing Solutions
APPLICATIONS BROCHURE
APPLICATIONS
Modular Skids/ Enclosures/ E-Houses/ Conduit Seals/ PLC/ Corrosion Protection
Buildings Cabinets Motor Control Duct Banks DCS Retrofit Seals
Centers
Protect Your Equipment with Roxtec
The Roxtec Sealing System protects
cable and pipe entries from:
■■ Water
■■ Rodents/Pests
■■ Fire
■■ Vibration
■■ Hazardous Gas
■■ Dust
■■ Lightning
WHY USE ROXTEC?
■■ Retrofit around existing cables or pipes
■■ Corrosion resistant
■■ Adapts to cables and pipes of different sizes
■■ Pull-out tested
■■ Customized solutions
■■ Certified protection
■■ Lowest total cost of ownership
■■ Long term operational reliability
■■ Low maintenance
Engineered Solutions for
Safety and Protection
Protect lives and assets with a cable and pipe transit system.
Roxtec transits provide an area efficient seal for cables and
pipes passing through walls, floors, cabinets/enclosures, con-
duits and duct banks.
Roxtec transit systems seal cable and pipe entries from water,
fire, rodents/pests, hazardous gases, dust, humidity, and other
environmental hazards. Roxtec simplifies site maintenance allow-
ing additional cables and pipes to be added easily.
Where to Use Roxtec
APPLICATION AREAS
■■ Conduit seals/Duct banks ■■ Blast resistant buildings
■■ Junction boxes ■■ Communication shelters
■■ E-houses ■■ Vapor tight walls
■■ Switchgear ■■ Cable trenches/Pull boxes
■■ Heat trace cabinets ■■ Electrical & Instrumentation
Enclosures
■■ Modular skids
■■ Marshalling cabinets
■■ Hazardous locations Multidiameter™ - a solution for
■■ Cable tray adaptability to cables and pipes
■■ Transformers of different sizes based on
modules with removable layers.
INDUSTRIES
■■ Power Generation ■■ Commercial buildings
■■ Power T&D ■■ Airports
■■ Railway ■■ Nuclear
■■ Oil and Gas ■■ Telecom
■■ Mining ■■ Manufacturing
■■ Cleanrooms ■■ Food and beverage
■■ Datacenters ■■ Marine What is a Roxtec Transit?
Scan to learn more
■■ Wastewater treatment ■■ Offshore Oil and Gas
Cabinets and Enclosures Solutions
Roxtec’s Enclosure Solutions seal a heavy cable
schedule in a smaller footprint, reducing enclosure
size, and weight by up to 70%. Replace connectors
with Roxtec to manage multiple cables with a single
cutout.
Seal armored cables with the Roxtec BG™ B
system for bonding and grounding. Roxtec’s
cabinet seals simplify long term maintenance
allowing cables to be added or changed easily.
Various materials and sizes available.
Applications
■■ Marshalling Cabinets
■■ Control Cabinets
■■ Junction Boxes
■■ PLC/DCS Enclosures
■■ Electric Heat Trace Cabinets
■■ Safety Instrumented Systems
■■ Fire and Gas Detection Equpment Cabinets
■■ Communication Equipment Enclosures
Area
Efficient
Cabinets & Enclosures Solutions
■■ 70% more area efficient
■■ Watertight
■■ Dust tight
■■ Rodent/pest barrier
■■ Open frame design for existing cables
■■ Re-openable frame to make changes easily
■■ Long-term operational reliability
■■ Flexible and adaptable for various cable sizes
■■ UL/NEMA 3,3r, 4, 4x, 12, 13
■■ IP 66/67 and IP 69K
■■ Hazardous locations
For a complete line of our cabinet seal products
download our Cabinet Seal Catalog
Building Entries
Roxtec transits for wall and
floor penetrations protect
against gas, smoke, fire,
pests, and the elements.
The G Frame provides a clean
pass-through for various sized
cables and offers spare ca-
pacity for additional cables to
be run in the future.
Applications
■■ Walls/Floors ■■ PDC’s
■■ Modular/Pre-Fabricated ■■ MCC’s
Buildings ■■ Blast resistant buildings
■■ Concrete/Gypsum/Cinder ■■ Cable tray
block/Steel walls
Building Entry Solutions
■■ New & Retrofit ■■ Open frame design for existing
■■ Bolted & Casted installation cables
■■ Primed mild steel (unpainted), ■■ Re-openable frame to make
Galvanized steel, Stainless changes easily
steel ■■ Long-term operational reliability
■■ Watertight - 58 PSI ■■ Flexible and adaptable for
■■ Fire UL1479 various cable sizes
■■ Rodents/Pests barrier ■■ UL/NEMA 4, 4x, 12, 13
■■ IP 66/67
For more information refer to ■■ Hazardous locations
G Frame Product Catalog Page # 70
Cable Trenches/Pull Boxes
Keep water and rodents out of
your building with the Roxtec
cable sealing system.
The Roxtec G frame provides
a clean pass-through for
various sized cables and
provides spare capacity for
future cable changes.
Cable Trench Solutions
■■ New & Retrofit ■■ Open frame design for existing
■■ Bolted & Casted installation cables
■■ Primed mild steel (unpainted), ■■ Re-openable frame to make
Galvanized steel, Stainless changes easily
steel ■■ Long-term operational reliability
■■ Watertight -58 PSI ■■ Flexible and adaptable for
■■ Fire UL1479 various cable sizes
■■ Rodents/Pests barrier ■■ UL/NEMA 4, 4x, 12, 13
■■ IP 66/67
G Frame For more information refer to ■■ Hazardous locations
Product Catalog Page # 70
Conduits/Sleeves/Core Drilled Holes
Protect conduits, duct banks and core drilled holes from water
and rodents with Roxtec’s round seals. Keep water from backing
up into the building and stop rodents and pests from entering
through open holes.
Single and multiple cable runs can be sealed with our selection of
round frames.
Applications
■■ Conduits
■■ Duct Banks
■■ Cored drilled holes
■■ Vaults
■■ Manholes
Underground Solutions
■■ Open frame design for existing
cables
■■ Re-openable frame to make
changes easily
■■ Long-term operational reliability
■■ Flexible and adaptable for
various cable sizes
■■ Hazardous locations
■■ New & Retrofit
■■ Plug conduits & duct
banks
■■ Galvanized or Stainless
steel fittings
■■ Watertight - 58 PSI
■■ Fire UL1479 (R & RS
frames only)
■■ Rodents/Pests barrier
R Frame RS Seal UG Seal For more information refer to
Product Catalog Pages:
# 117 - 149
SCADA/Telecom
Replace traditional cable boots with Roxtec’s CRL
Port Seal. The CRL provides increased line capacity to
maxed-out entry ports without modifying the existing
shelter or entry port.
Each sealing module has removable layers that can
accommodate various sizes of fiber, power and coax
cables.
ORE AFTE
BEF R
Telecom Solutions
■■ IP 54 Rating ■■ New & Retrofit
■■ Open frame for retrofit ■■ Expansion frame
applications ■■ Plastic (Polyamide) - 4”
■■ Four different module ■■ Primed mild steel - 5”
configurations
■■ IP 54
■■ Weather, water, pest & dust tight
■■ No drip-loop needed
■■ Easy to install and add coax in
the future CRL Port Seal For more information refer
to Product Catalog Page:
# 155
Pipe Seals
Roxtec round sealing solutions can be used for
plastic pipes, metal pipes and conduits of vari-
ous sizes. Provide protection for above ground
and underground pipes running through walls
and floors.
Protect against water ingress, fire, rodents/
pests, hazardous gases and other environmental
hazards.
■■ Watertight - 58 PSI
■■ Firestop - UL1479 up to Pipe Solutions
4 hours
■■ Galvanized or Stainless ■■ Open frame design for existing pipes
steel fittings ■■ Re-openable frame to make changes easily
■■ Hazardous locations ■■ Long-term operational reliability
■■ Rodents/Pests barrier ■■ Flexible and adaptable for various pipe sizes
■■ Core drilled holes ■■ Low maintenance
■■ Sleeves available ■■ Metal and plastic pipes
RS Seal
For more information refer
to Product Catalog Pages:
# 121 - 149
EX/ATEX - Hazardous Locations
Protect lives and assets in hazardous locations or po-
tential explosive atmospheres with Roxtec’s EX product
family.
Our cable and pipe sealing systems are approved for
hazardous locations and are clearly marked in accordance
with international directives. They are easily identified by
the yellow Ex label
Roxtec EX/ATEX products can be installed in walls,
floors, cabinets and enclosures.
Approved for hazardous areas
A place in which an explosive atmosphere consisting of a mixture with air of dangerous
Zone 1 (gases) substances in the form of gas, vapor, or mist is likelyl to occur in normal operation between
10-1000 hrs per year.
A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is
Zone 21 (dust)
likely to occur in normal operation between 10-1000 hrs per year.
A place in which an explosive atmosphere consisting of a mixture with air of dangerous
Zone 2 (gases) substances in the form of gas, vapor, or mist is not likely to occur in normal operation but if
it does occur, will persist for less than 10 hrs per year.
A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is
Zone 22 (dust) not likely to occur in normal operation but, if it does occur, will persist for less than 10 hrs
per year.
Approved for global electrical schemes
■■ IECEx
■■ ATEX
All Roxtec EX Products are For a complete line of our EX/ATEX
clearly marked in accordance
with international directives.
rated products download our
They are easily identified by the EX Catalog
yellow EX label.
Armored Cables
Reduce cable entry footprint with Roxtec’s
seals. Specify Roxtec’s BG™ B (bonding and
grounding) products to replace teck connectors
for terminating armored cables.
The bonding and ground modules simplify adding
cables in the future, offer flexibility for installers,
reduce material costs, protect equipment, and
protect lives.
Bonding & Ground Solutions
■■ Reduce cabinet space by 70% compared to
teck connectors
■■ Quicker intallation time compared to connectors
■■ Bonding and grounding protection
■■ Armor and metal clad cables
■■ Fire and blast rated, gas and water tight
■■ Approved for hazardous locations (Ex)
■■ Lightning protection
■■ Flexible and adaptable for various cable sizes
*Certified for Class 1, Zone 1 & 2 - Class 1, Division 2 (not division 1 enclosures)
■■ New & Retrofit
■■ Bolted & Casted installation
■■ Primed mild steel (unpainted)
Galvanized steel, Stainless steel
■■ Cast aluminum (CF 32)
BG™ B Module ■■ UL/NEMA 4, 4x, 12, 13
■■ IP 66/67
■■ AEx, IECEx, ATEX
■■ Rodents/Pests barrier
BG™ B CF 32 Kit For a complete line of our BG™
Lubricant
solutions download our
EMC Catalog
EMC Protection
Protect communication equipment such as SCADA cab-
inets, SCIFs and EMC enclosures from electromagnetic
interference and electromagnetic pulses with the Roxtec
EMC Sealing solutions.
Roxtec EMC/EMI sealing solutions can be installed in walls,
floors, cabinets and enclosures.
EMC Solutions
■■ Complete electrically sealed environmentI
■■ Electromagnetic interference protection
■■ Electromagnetic pulse protection
■■ IP 66/67 For a complete line of our EMC
■■ Firestop - UL1479 up to 4 hours solutions download our
■■ UL/NEMA 4, 4x, 12, 13 EMC Catalog
Easy Installation
High safety standards require correctly installed and easily Installation and Training Tools
inspected products. Complimentary on-site installation
■■ Reduce installation time and labor costs
training for local contractors and post-installation inspection
are part of our full line of service. ■■ Ensure quality installation
■■ Engineered specficially for Roxtec
Products
How it Works
Roxtec Installation
Videos
It is easy to specify Roxtec
A = Hole width
B = Hole height
C = Frame width
A
D = Frame height
E = Tray width
B
D
+
For quick reference, Roxtec frames Example
can be chosen based on the size (ZxN)
of the cable tray. This allows the 6x3
frame dimensions to be specified
or included in the project drawings.
While this will give a quick reference
for the project, we recommend using (Z+ZxN)
6+6x3
the Roxtec Transit Designer software
or contacting your local Roxtec Z = Frame size
(6 = 218 mm, 8 = 278 mm)
representative for complimentary N = Number of horizontal Combination + Combination
designs and drawings. openings
x
Tray/ladder Roxtec frame Size Wall opening size Frame width
mm/in (E) (Z) (A) mm/in (B) mm/in (C) mm/in (D) mm/in
6 278/10.945 245/9.646 463/18.228 430/16.929
GH Zx2
8 278/10.945 305/12.008 463/18.228 490/19.291
300/12
6 278/10.945 475/18.700 463/18.228 580/22.346
GH Z+Zx2
8 278/10.945 595/23.425 463/18.228 700/27.559
6 409/16.102 245/9.646 593.5/23.366 430/16.929
GH Zx3
8 409/16.102 305/12.008 593.5/23.366 490/19.291
500/18
6 409/16.102 475/18.700 593.5/23.366 580/22.346
GH Z+Zx3
8 409/16.102 595/23.425 593.5/23.366 700/27.559
6 539/21.220 245/9.646 724/28.504 430/16.929
GH Zx4
8 539/21.220 305/12.008 724/28.504 490/19.291
600/24
6 539/21.220 475/18.700 724/28.504 580/22.346
GH Z+Zx4
8 539/21.220 595/23.425 724/28.504 700/27.559
6 930.5/36.634 245/9.646 1115.5/43.917 430/16.929
GH Zx7
8 930.5/36.634 305/12.008 1115.5/43.917 490/19.291
900/36
6 930.5/36.634 475/18.700 1115.5/43.917 580/22.346
GH Z+Zx7
8 930.5/36.634 595/23.425 1115.5/43.917 700/27.559
*Some certifications may have size restrictions. Please contact technical support at 1-800-520-4769 with any questions.
™
Roxtec Transit Designer
The Roxtec Transit Designer™ is a free, web-based
engineering tool. It allows auto-planning, drives
project efficiency and reduces the risk of mistakes
in all project phases.
Roxtec Transit Designer™ simplifies
design, product selection,
purchasing, and installation of
Roxtec’s transits. Its batch import
with auto validation feature helps
designers create and update thou-
sands of transits automatically and
take full control of their largest pro-
ject designs. They can also validate
their complete project by using the
Roxtec CAD symbols and the Roxtec
Transit Designer™ for easy incorpo-
ration of transits into the design of
the entire facility.
Always available, everywhere
The Roxtec Transit Designer™ is
accessible online. You can share your
work with project teams anywhere
in the world, and Roxtec experts are GET STARTED ON
always available through the chat func- [Link]
tion. To start using it, just register on
[Link].
Features
■■ Free web-based application,
available online
■■ Simple product selection
■■ Copy and paste for cable or pipe
schedule inputs
■■ Manufacturer-approved SIMPLE USER INPUT APPROVED OUTPUT
engineering outputs
■■ Improves project efficiency Cable/pipe schedule 2D, CAD drawings in DXF
or estimates and PDF
and flexibility
■■ Batch import with auto validation Sealing/certification 3D STEP
■■ Import multiple transits to speed requirements Bill of material in Excel
up design work Installation preferences Installation instructions
■■ Reduces project risks Material quality selection
Things to Consider When Choosing a
Cable and Pipe Sealing Solution
■■ Do you require water ingress protection?
■■ Is there a need to keep dust out?
■■ Do you need protection for a certified hazardous location?
■■ Do you need to keep rodents/pests out?
■■ Do you need to seal a range of cable and pipes?
■■ Do you have blast rated areas or buildings?
■■ Do you need vapor or gas tight protection?
■■ Will you need to install cables in wet or high relative humidity conditions?
■■ Is cable retention an issue?
■■ Do you need to protect people and assets from smoke and fire?
■■ If using armored cables, is there a need for bonding and grounding?
■■ Do you have frequent cable changes?
■■ Do you need flexiblity for changing cable schedules?
Roxtec Inc.
10127 E. Admiral Place, Tulsa, OK 74116, USA
PHONE 918 254 9872, FAX 918 254 2544
EMAIL info@[Link], [Link]/us