Spare Power Feed Outputs C07.
03
Table of Contents
System Overview
Terms and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 500
General Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 501
Components
Component Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 600
Component Details . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 601
Troubleshooting
Troubleshooting Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 700
Cascadia Troubleshooting Manual, September 2008
Spare Power Feed Outputs C07.03
500 — Terms and Abbreviations
CAN—Controller Area Network
ECU—Electronic Control Unit, typically connected to a datalink.
LVD—Low Voltage Disconnect
SAM—Signal Detect and Actuation Module
SAM Cab—Signal Detect and Actuation Module Cab ("SAM Cabin"); this ECU controls mainly cab-related func-
tionality. See G02.04 — SAM Cab for more information.
501 — General Information
"Spare power feed outputs" are pins that provide battery power and ground as spare outputs on the SAM Cab
ECU. These pins are not controlled by software. Some of the battery outputs are controlled by low voltage dis-
connect (LVD) functionality.
There are two different groups of battery output pins in this feature:
• Pins that are directly connected to the battery by fuse, and therefore are not controlled by the SAM Cab.
• Pins that depend on power management. These pins are grouped on relays and are controlled by LVD.
See C06.09 — Powernet Management for more information on LVD.
IMPORTANT: The pins provide spare battery and ground connections. The circuits and functions connected to
them are not pre-defined.
600 — Component Locations
02/07/2007 f544945
Fig. 1, SAM Cab
Cascadia Troubleshooting Manual, September 2008 C07.03/1
C07.03 Spare Power Feed Outputs
601 — Component Details
X18
X21
X19
R11
X20
R7
F22
F1 R1 F19 R3
X4
F29
X1
X5
X14
X2
X15
X6
X3
X16
X7
X17
X8
R14
X9 F40
R15
NOTE: The square labels indicate fuses and relays,
and the circular labels indicate connectors. F13 F18 R6 F28 R10
09/19/2007 f545092
Fig. 2, SAM Cab Fuses and Relays
SAM Cab Fuses and Relays
Terminal Nominal
SAM Cabin Hardware
Description Cavity Relay Fuse Load in A LVD Level
Connector level
Number & 25C
Power feed spare output I, R1 (n/c
X4 1 F1 (30) Low 30 4
battery LVD)
Power feed spare output I,
X4 3 — — Low — —
ground
Power feed spare output II, R1 (n/c
X5 1 F3 (30) Low 30 4
battery LVD)
Power feed spare output II,
X5 3 — — Low — —
ground
C07.03/2 Cascadia Troubleshooting Manual, September 2008
Spare Power Feed Outputs C07.03
SAM Cab Fuses and Relays
Terminal Nominal
SAM Cabin Hardware
Description Cavity Relay Fuse Load in A LVD Level
Connector level
Number & 25C
Power feed spare output III, R1 (n/c
X4 2 F1 (30) High 30 4
battery LVD)
Power feed spare output III,
X4 4 — — High — —
ground
Power feed spare output IV, R2 (n/c
X5 2 F3 (30) High 30 4
battery LVD)
Power feed spare output IV,
X5 4 — — High — —
ground
Power feed spare output V,
X15 1 — F32 (25) High 30 0
battery
Power feed spare output V,
X15 3 — — High — —
ground
Power feed spare output VI,
X15 2 — F32 (25) High 30 0
battery
Table 1, SAM Cab Fuses and Relays
700 — Troubleshooting Overview
Spare power feed outputs are on the SAM Cab ECU. All of the battery output pins involve a fuse, and some bat-
tery output pins involve a relay. Refer to 601 — Component Details for fuse and relay numbers associated with
each pin. Since no CAN fault codes are available for this feature, troubleshooting should begin with verifying that
the associated fuse and relay (if present) is functioning.
Cascadia Troubleshooting Manual, September 2008 C07.03/3