Programmable / Preset Counter XTC5400
Features :
Dual Display, 4 digits, 7 segment LED
LED Indication : Relay1, Relay2, Seconds, Minutes, Hours
2 Set points
Programmable input scaling
Down counting for timer, Up / Down counting for counter
Batch counting
48 x 48 mm Certications :
®
Technical specifications
Display specifications
Digits 4 digits, 7 segment LED
LED indication Relay1, Relay2, Seconds, Minutes, Hours
Input specifications
Sensor type NPN / PNP
Voltage pulse (3 to 30V DC) from
Input type Proximity switches, Solid state devices,
Potential free contact encoder
a) 3Hz
Input speed b) 30Hz
c) 5kHz
Timer : ± 0.05% of setting or
Accuracy 50 ms whichever is greater
Counter : ± 2 counts
Output specifications
Sensor supply Inbuilt, 12V DC, 30mA (short circuit protected)
Relay contact 2 C/O SPST
Contact rating 5A @ 230V AC
Functional specifications
ON delay / Interval / Auto reset / Time pulse repeat
Cyclic OFF first, Batch
Modes Counter : ON delay, Interval, Auto reset,
Time pulse repeat, Batch
Timer : 0 - 99.99 / 0 - 999.9 / 0 - 9999sec
0 - 99.59min : sec, 0 - 999.9 / 0 -9999min
Ranges
0 - 99.59hr : min, 0 - 999.9 / 0 - 9999hr
Counter : - 999 to 9999 counts
Resolution 0.01sec
Counting direction Timer : Down; Counter : Up / down
Set point 2
0.001 to 9.999 x 10
Scale factor n = -3, -2, -1, 0, 1, 2
Reset Front, Remote, Power interruption
Memory retention Yes
Configuration lock Password protected
Auxiliary supply specifications
Supply voltage 90 to 270V AC / DC (50 / 60Hz)
-15% to 10% tolerance
Power consumption 5VA Max.
www.selec.com 1
Programmable / Preset Counter XTC5400
Environment specifications
Operating : 0 to 50oC (32 to 122oF)
Temperature
Storage : -20 to 75oC (-4 to 167oF)
Humidity (non - condensing) 95% RH
Mechanical specifications
Mounting Panel mount
Weight 170gms
Terminal connections Compliance
Applicable EMI / EMC Standards
Product Standard
NO1 Category Reference Standards Testing Level
Electrostatic Discharge IEC 61000-4-2 Level-3
Electrical Fast Transient / Brust IEC 61000-4-4 Level-3
Electromagnetic Field IEC 61000-4-3 Level-3
Surge IEC 61000-4-5 Level-3
Conducted RF IEC 61000-4-6 Level-2
Rated Power Frequency IEC 61000-4-8 Level-4
Dimensions Voltage Dip / Short Interruptions IEC 61000-4-11 Level-3
Conducted Emissions CISPR-11 Class-B
A G
Rated Emissions CISPR-22 Class-A
D Emission & Immunity IEC 61326-1
F
B
Safety IEC 61010-1
C
E PFMF (Passing criteria) IEC 61000-4-8 Class A
MODELS DIM A B C D E F G
XTC5400 48 48 100 45 10 46 46
Ordering information
Product code Supply voltage Certification
XTC5400 90 to 270V AC / DC C
E253771
US
XTC5400-CU-RoHS 90 to 270V AC / DC C US
E253771
www.selec.com 2