Morphology Dense Urban
Data Channel Type PUSCH PDSCH PDSCH
Duplex Mode TDD TDD TDD
User Environment Indoor
System Bandwidth (MHz) 20.0 100.0
Channel Model ETU 3
Cell Edge Rate (kbps) 5120.00 102400.00 102400.00
MCS 12 16/64QAM 16/64QAM
Tx PUSCH PDSCH PDSCH
Max Total Tx Power (dBm) 23.00 46.00 46.00
Allocated RB 18.00 106.00 273.00
Allocated Subcarriers 216.00 1272.00 3276.00
Subcarrier Power (dBm) -0.34 14.96 10.85
Tx Antenna Gain (dBi) 0.00 18.50 18.50
Tx Cable Loss (dB) 0.00 0.50 0.50
Tx Body loss (dB) 0.00 0.00 0.00
EIRP per Subcarrier (dBm) -0.34 32.96 28.85
Rx PUSCH PDSCH PDSCH
SINR (dB) 2.00 8.56 8.56
Rx Noise Figure (dB) 5.00 5.00 5.00
Receiver Sensitivity (dBm) -112.69 -118.68 -115.67
Rx Antenna Gain (dBi) 18.00 0.00 0.00
Rx Cable Loss (dB) 0.50 0.00 0.00
Rx Body loss (dB) 0.00 0.00 0.00
Neighbor Load 50.00% 100.00% 100.00%
Interference Margin (dB) 0.73 4.39 4.39
Min Signal Reception Strength (dBm) -129.46 -114.29 -111.28
Path Loss & Cell Radius
Foliage loss, dB 0 0 0
Penetration Loss (dB) 0.00 0.00 0.00
Std.of Shadow Fading (dB) 11.70 11.70 11.70
Area Coverage Probability 95.00% 95.00% 95.00%
Shadow Fading Margin (dB) 6.00 6.00 6.00
Slow fading margin, dB 0.00 0.00 0.00
Path Loss (dB) 123.11 141.24 134.13
Propagation Model
eNodeB/UE Antenna Height (m) 35.00 10.00 10.00
Frequency (MHz) 3410.00 3410.00 3410.00
Cell Radius (km) 75.00 239.00 155.00
383.46 1120.00 735.00
20 Nhz 100 Mhz
NRB 106 273
SCS 15 30
UL/20 UL/100 DL/20
1slot/1ms2slots/1ms1slot/1ms
NRB 10 50
3360 50400
3360000 50400000
3.36 50.4
11.366666667
11.366666667
d'BP = 4 h'BS h'UT fc/c Dbp 31826.666667
Plum_NLOS PL1
NLOS )
PLUMa NLOS max( PLUMa LOS , PLUMa 10.62957834 10.629578341
5.1 0
NLOS 13.54 39.08 log10 d 3D SF
PLUMa 6 13.54 28
20 log10 f c 0.6(hUT 1.5) 19.06957834 38.629578341
10m d 2D 5km 115.06 84.48
2.944108756 3.8401021139
PL 10m d 2D d BP d3d 879.242669 6919.9365747
PLUMa LOS 1
d 2D 5km
PL2 d BP 773067.671 47885522.198
PL1 28.0 22 log10 (d 3D ) 20 log10 ( f
c ) SF 4
1225 1225
PL2 28.0 40 log10 (d 3D ) 20 log10 ( f c ) 771842.671 47884297.198
878.5457706 6919.8480618
) 2 (hBS hUT ) 2 )
9 log10 ((d BP
1228.427
PL2
10.6295783408451
28
38.6295783408451
225
1012936711.11111
1012936936.11111
-81.0502416692854
2.47
295.5213242466190 d3d
87332.853084475400
1225
86107.853084475400
293.441396337455
Allocated RB/ PUSCH 18.00 Parameters
SINR (dB)/PDSCH 8.56 Allocated RB
SINR (dB)/PUSCH 2.00 SINR (dB)
modulation order modulation order
PDSCH PUSCH
18.00
8.56 2.00
6.00 6.00
Dense Urban
Link budget parameters UL DL/20MHz DL/20MHz
Min Signal Reception Strength (dBm) -112.69 -118.68 -115.67
Foliage loss, dB 5 5 5
Penetration Loss (dB) 26 26 26
Area Coverage Probability 0.95 0.95 0.95
Shadow Fading Margin (dB) 8 8 8
Path Loss (dB)/otdoor 121.1118 139.2442 132.1253
Propagation Model UMaNLOS UMaNLOS UMaNLOS
eNodeB/UE Antenna Height (m) 35 10 10
Frequency (MHz) 3410 3410 3410
Cell Radius (km)/indoor 0.055 0.138 0.86
Cell Radius (km)/outdoor 0.302 0.658 0.432
Sub_Urban
Link budget parameters UL DL/20MHz DL/20MHz
Min Signal Reception Strength (dBm) -112.686 -118.679 -115.669
Foliage loss, dB 5 5 5
Penetration Loss (dB) 18 18 18
Area Coverage Probability 0.95 0.95 0.95
Shadow Fading Margin (dB) 6 6 6
Path Loss (dB)/otdoor 121.1118 139.2442 132.1253
Propagation Model UMaNLOS UMaNLOS UMaNLOS
eNodeB/UE Antenna Height (m) 35 10 10
Frequency (MHz) 3410 3410 3410
Cell Radius (km)/indoor 0.113 0.254 0.165
Cell Radius (km)/outdoor 0.34 0.741 0.486
Urban
Link budget parameters UL DL/20MHz DL/20MHz
Min Signal Reception Strength (dBm) -112.686 -118.679 -115.669 Clutter Type
Foliage loss, dB 5 5 5 Dense Urban
Penetration Loss (dB) 22 22 22 Urban
Area Coverage Probability 0.95 0.95 0.95 Sub_Urban
Shadow Fading Margin (dB) 7 7 7 Rural
Path Loss (dB)/otdoor 121.1118 139.2442 132.1253
Propagation Model UMaNLOS UMaNLOS UMaNLOS
eNodeB/UE Antenna Height (m) 35 10 10
Frequency (MHz) 3410 3410 3410 Clutter Type
Cell Radius (km)/indoor 0.081 0.189 0.12 Dense Urban
Cell Radius (km)/outdoor 0.32 0.698 0.459 Urban
Sub_Urban
Rural Rural
Link budget parameters UL DL/20MHz DL/20MHz
Min Signal Reception Strength (dBm) -112.686 -118.679 -115.669
Foliage loss, dB 5 5 5
Penetration Loss (dB) 15 15 15
Area Coverage Probability 0.95 0.95 0.95 Clutter Type
Shadow Fading Margin (dB) 5 5 5 Dense Urban
Path Loss (dB)/otdoor 121.1118 139.2442 132.1253 Urban
Propagation Model RMaNLOS RMaNLOS RMaNLOS Sub_Urban
eNodeB/UE Antenna Height (m) 45 10 10 Rural
Frequency (MHz) 3410 3410 3410
Cell Radius (km)/indoor 0.303 0.671 0.437
Cell Radius (km)/outdoor 1.67 3.7 2.4
3.41 GHz-UL indoor 3.41 GHz-DL_indoor/20MHz 3.41 GHz-DL_indoor/100MHz
0.055 0.138 0.86
0.081 0.189 0.12
0.113 0.254 0.165
0.303 0.671 0.437
3.41 GHz-UL outdoor 3.41 GHz-DL_outdoor/20MHz3.41 GHz-DL_outdoor/100MHz
0.302 0.658 0.432
0.32 0.698 0.459
0.34 0.741 0.486
1.67 3.7 2.4
3.41 GHz-UL indoor 3.41 GHz-UL outdoor 24.3 GHz-UL outdoor
0.081 0.406 0.236
0.113 0.431 0.251
0.155 0.458 0.266
0.303 1.67 1.475
Clutter Type 3.41 GHz-DL_indoor/20MHz 3.41 GHz-DL_outdoor/20MHz
Dense Urban 0.254 1.118
Urban 0.343 1.26
Sub_Urban 0.461 0.1336
Rural 0.671 3.7
Clutter Type 24.3 GHz-UL outdoor
Dense Urban 0.236
Urban 0.251
Sub_Urban 0.266
Rural 1.475
or/100MHz
3.41 GHz-DL_indoor/100MHz 3.41 GHz-DL_outdoor/100MHz 24.3 GHz-DL_outdoor/100MHz
0.165 0.78
0.224 0.828
0.302 0.878
0.437 2.4
24.3 GHz-DL_outdoor/100MHz
0.456
0.484
0.513
2.11
Dense Urban Urban
Link budget parameters UL DL/20MHz DL/100MHz Link budget parameters UL DL/20MHz
Min Signal Reception Strength (dBm) -112.69 -118.68 -115.67 Min Signal Reception Strength (dBm) -112.686 -118.679
Foliage loss, dB 0 0 0 Foliage loss, dB 0 0
Penetration Loss (dB) 26 26 26 Penetration Loss (dB) 22 22
Area Coverage Probability 0.95 0.95 0.95 Area Coverage Probability 0.95 0.95
Shadow Fading Margin (dB) 8 8 8 Shadow Fading Margin (dB) 7 7
Path Loss (dB)/otdoor 121.1118 139.2442 132.125348522 Path Loss (dB)/otdoor 121.1118 139.2442
Propagation Model UMaNLOS UMaNLOS UMaNLOS Propagation Model UMaNLOS UMaNLOS
eNodeB/UE Antenna Height (m) 35 10 10 eNodeB/UE Antenna Height (m) 35 10
Frequency (MHz) 3410 3410 3410 Frequency (MHz) 3410 3410
Cell Radius (km)/indoor 0.081 0.254 0.165 Cell Radius (km)/indoor 0.113 0.343
Cell Radius (km)/outdoor 0.406 1.118 0.78 Cell Radius (km)/outdoor 0.431 1.26
Sub_Urban Rural
Link budget parameters UL DL/20MHz DL/100MHz Link budget parameters UL DL/20MHz
Min Signal Reception Strength (dBm) -112.686 -118.679 -115.66878745 Min Signal Reception Strength (dBm) -112.686 -118.679
Foliage loss, dB 0 0 0 Foliage loss, dB 5 5
Penetration Loss (dB) 18 18 18 Penetration Loss (dB) 15 15
Area Coverage Probability 0.95 0.95 0.95 Area Coverage Probability 0.95 0.95
Shadow Fading Margin (dB) 6 6 6 Shadow Fading Margin (dB) 5 5
Path Loss (dB)/otdoor 121.1118 139.2442 132.125348522 Path Loss (dB)/otdoor 121.1118 139.2442
Propagation Model UMaNLOS UMaNLOS UMaNLOS Propagation Model RMaNLOS RMaNLOS
eNodeB/UE Antenna Height (m) 35 10 10 eNodeB/UE Antenna Height (m) 45 10
Frequency (MHz) 3410 3410 3410 Frequency (MHz) 3410 3410
Cell Radius (km)/indoor 0.155 0.461 0.302 Cell Radius (km)/indoor 0.303 0.671
Cell Radius (km)/outdoor 0.458 0.1336 0.878 Cell Radius (km)/outdoor 1.67 3.7
DL/100MHz
-115.66878745
0
22
0.95
7
132.125348522
UMaNLOS
10
3410
0.224
0.828
DL/100MHz
-115.66878745
5
15
0.95
5 371973
132.125348522 102755
RMaNLOS
10
3410
0.437
2.4
Dense Urban
Link budget parameters UL DL/100MHz
Min Signal Reception Strength (dBm) -129.456 -108.27
Foliage loss, dB 0 0
Penetration Loss (dB) 0 0
Area Coverage Probability 0.95 0.95
Shadow Fading Margin (dB) 6 6
Path Loss (dB)/otdoor 121.1118 132.12534852
Propagation Model UMNLOS UMNLOS
eNodeB/UE Antenna Height (m) 35 20
Frequency (MHz) 24300 24300
Cell Radius (km)/outdoor 0.236 0.46
Sub_Urban
Link budget parameters UL DL/100MHz
Min Signal Reception Strength (dBm) -129.456 -108.27
Foliage loss, dB 0 0
Penetration Loss (dB) 0 0
Area Coverage Probability 0.95 0.95
Shadow Fading Margin (dB) 4 4
Path Loss (dB)/otdoor 121.1118 132.12534852
Propagation Model UMNLOS UMNLOS
eNodeB/UE Antenna Height (m) 35 20
Frequency (MHz) 24300 24300
Cell Radius (km)/outdoor 0.266 0.518
Urban
Link budget parameters UL DL/100MHz
Min Signal Reception Strength (dBm) -129.456 -108.27
Foliage loss, dB 0 0
Penetration Loss (dB) 0 0
Area Coverage Probability 0.95 0.95
Shadow Fading Margin (dB) 5 5
Path Loss (dB)/otdoor 121.1118 132.12534852
Propagation Model UMNLOS UMNLOS
eNodeB/UE Antenna Height (m) 35 20
Frequency (MHz) 24300 24300
Cell Radius (km)/outdoor 0.251 0.488
Rural
Link budget parameters UL DL/100MHz
Min Signal Reception Strength (dBm) -129.456 -108.27
Foliage loss, dB 5 5
Penetration Loss (dB) 0 0
Area Coverage Probability 0.95 0.95
Shadow Fading Margin (dB) 3 3
Path Loss (dB)/otdoor 121.1118 132.12534852
Propagation Model UMNLOS UMNLOS
eNodeB/UE Antenna Height (m) 45 10
Frequency (MHz) 24300 24300
Cell Radius (km)/outdoor 1.475 2.4
Morphology Dense Urban
Data Channel Type PUSCH PDSCH PDSCH
Duplex Mode TDD TDD TDD
User Environment Indoor
System Bandwidth (MHz) 20.0 100.0
Channel Model ETU 3
Cell Edge Rate (kbps) 5120.00 102400.00 102400.00
MCS 12 16/64QAM 16/64QAM
Tx
Max Total Tx Power (dBm) 23.00 46.00 46.00
Allocated RB 18 106 132
Allocated Subcarriers 216 1272 1584
Subcarrier Power (dBm) -0.34 14.96 14.00
Tx Antenna Gain (dBi) 0.00 18.50 18.50
Tx Cable Loss (dB) 0.00 0.50 0.50
Tx Body loss (dB) 0.00 0.00 0.00
EIRP per Subcarrier (dBm) -0.34 32.96 32.00
Rx
SINR (dB) 2.00 8.56 8.56
Rx Noise Figure (dB) 5.00 5.00 5.00
Receiver Sensitivity (dBm) -112.69 -118.68 -112.66
Rx Antenna Gain (dBi) 18.00 0.00 0.00
Rx Cable Loss (dB) 0.50 0.00 0.00
Rx Body loss (dB) 0.00 0.00 0.00
Neighbor Load 50.00% 100.00% 100.00%
Interference Margin (dB) 0.73 4.39 4.39
Min Signal Reception Strength (dBm) -129.46 -114.29 -108.27
Path Loss & Cell Radius
Foliage loss, dB 5 5 5
Penetration Loss (dB) 0.00 0.00 0.00
Std.of Shadow Fading (dB) 11.70 11.70 11.70
Area Coverage Probability 95.00% 95.00% 95.00%
Shadow Fading Margin (dB) 5.00 5.00 3.00
Slow fading margin, dB 0.00 0.00 0.00
Path Loss (dB) 119.11 132.24 127.27
Propagation Model
eNodeB/UE Antenna Height (m) 35.00 10.00 10.00
Frequency (MHz) 3410.00 3410.00 3410.00
Cell Radius (km)
W H HU HBS HU
8 15 5 45 10
PL1
27.7121254719662
6.62412117314482
38.9089813165055
-11.1968558445392
6.4119389076428
8.82068444291761
163.448745535275
1.65321251377534
23.9588888888889
39.6091349272642
112.642754763471
43.42
5.12495879270357
38.2950412072964
14.63
0.38
3.38
2409.82938828126
5807277.6806240400
1225
5806052.6806240400
2409.57520750527
0.303 0.671 0.437
Morphology Dense Urban
Data Channel Type PUSCH PDSCH PDSCH
Duplex Mode TDD TDD TDD
User Environment Indoor
System Bandwidth (MHz) 20.0 100.0
Channel Model ETU 3
Cell Edge Rate (kbps) 5120.00 102400.00 102400.00
MCS 12 16/64QAM 16/64QAM
Tx
Max Total Tx Power (dBm) 23.00 46.00 46.00
Allocated RB 18 106 132
Allocated Subcarriers 216 1272 1584
Subcarrier Power (dBm) -0.34 14.96 14.00
Tx Antenna Gain (dBi) 0.00 18.50 18.50
Tx Cable Loss (dB) 0.00 0.50 0.50
Tx Body loss (dB) 0.00 0.00 0.00
EIRP per Subcarrier (dBm) -0.34 32.96 32.00
Rx
SINR (dB) 2.00 8.56 8.56 PLUMa NLO
Rx Noise Figure (dB) 5.00 5.00 5.00
Receiver Sensitivity (dBm) -112.69 -118.68 -112.66 NLOS
PLUMa
Rx Antenna Gain (dBi) 18.00 0.00 0.00
Rx Cable Loss (dB) 0.50 0.00 0.00
Rx Body loss (dB) 0.00 0.00 0.00
Neighbor Load 50.00% 100.00% 100.00%
Interference Margin (dB) 0.73 4.39 4.39
Min Signal Reception Strength (dBm) -129.46 -114.29 -108.27 PLUMa LOS
Path Loss & Cell Radius
Foliage loss, dB 0 0 0 PL1 28.0
Penetration Loss (dB) 0.00 0.00 0.00
Std.of Shadow Fading (dB) 11.70 11.70 11.70 PL2 28.0
Area Coverage Probability 95.00% 95.00% 95.00%
Shadow Fading Margin (dB) 6.00 6.00 6.00
Slow fading margin, dB 0.00 0.00 0.00
Path Loss (dB) 123.11 141.24 134.27
Propagation Model
eNodeB/UE Antenna Height (m) 35.00 20.00 20.00
Frequency (MHz) 24300.00 24300.00 24300.00
Cell Radius (km) 75.00 239.00 155.00
383.46 1120.00 735.00
20 Nhz 100 Mhz
NRB 106 273
SCS 15 30
UL/20 UL/100 DL/20
1slot/1ms2slots/1ms1slot/1ms
NRB 10 50
3360 50400
3360000 50400000
3.36 50.4
11.366666667
11.366666667
d'BP = 4 h'BS h'UT fc/c Dbp 31826.666667
Plum_NLOS PL1
NLOS )
PLUMa NLOS max( PLUMa LOS , PLUMa 27.71212547 10.629578341
11.1 0
NLOS 13.54 39.08 log10 d 3D SF
PLUMa 6 13.54 28
20 log10 f c 0.6(hUT 1.5) 30.15212547 38.629578341
10m d 2D 5km 104.12 84.48
2.664247959 3.8401021139
PL 10m d 2D d BP d3d 461.5810379 6919.9365747
PLUMa LOS 1
d 2D 5km
PL2 d BP 213057.0545 47885522.198
PL1 28.0 22 log10 (d 3D ) 20 log10 ( f
c ) SF 4
1225 1225
PL2 28.0 40 log10 (d 3D ) 20 log10 ( f c ) 211832.0545 47884297.198
460.2521641 6919.8480618
) 2 (hBS hUT ) 2 )
9 log10 ((d BP
1228.427
24250
PL2
10.6295783408451
28
38.6295783408451
225
1012936711.11111
1012936936.11111
-81.0502416692854
2.47
295.5213242466190 d3d
87332.853084475400
1225
86107.853084475400
293.441396337455