As indicated in SBC 304-CR-18
CHAPTER 25—REINFORCEMENT DETAILS
25.4—Development of reinforcement
25.4.2 Development of deformed bars and
deformed wires in tension
[Link] Development length 𝑙𝑙𝑑𝑑 for deformed bars
and deformed wires in tension shall be the greater
of (a) and (b):
(a) Length calculated in accordance with
[Link] or [Link] using the applicable
modification factors of [Link]
(b) 300 mm
[Link] For deformed bars or deformed wires, 𝑙𝑙𝑑𝑑
shall be calculated in accordance with Table
[Link].
25.5—Splices
25.5.2 Lap splice lengths of deformed bars and
deformed wires in tension
[Link] Tension lap splice length 𝑙𝑙 for
deformed bars and deformed wires in tension
shall be in accordance with Table [Link], where
𝑙𝑙 𝑑𝑑 shall be in accordance with [Link](a).
25.3—Standard hooks, seismic hooks,
crossties, and minimum inside bend
diameters
25.3.1 Standard hooks for the development of
deformed bars in tension shall conform to Table
25.3.1.