MS165-42 1/8

PRODUCT-DETAILS

MS165-42
MS165-42 Manual Motor Starter 30 ... 42 A

General Information
Extended Product Type MS165-42
Product ID 1SAM451000R1015
EAN 4013614486098
Catalog Description MS165-42 Manual Motor Starter 30 ... 42 A
MS165 is a compact and powerful range for motor protection up to 45 kW (400 V) / 80
A in width of 55 mm. They offer a reliable protection for motors in the event of
overload or phase failure. The devices have trip class 10.
This type has also a clear and reliable indication of fault in a separate window in the
event of short-circuit tripping. Further features are the build-in disconnect function,
temperature compensation, trip-free mechanism and a rotary handle with a clear
Long Description
switch position indication. The manual motor starter (also known as motor protection
circuit breaker or manual motor protector) is suitable for three- and single phase
applications. The handle is lockable to protect against unauthorized changes. Auxiliary
contacts, signaling contacts, undervoltage releases, shunt trips, power in-feed blocks
are available as accessory. These
are suitable throughout the MS116/MS132/MS165 range.

Ordering
Minimum Order Quantity 1 piece

© 2024 ABB. All rights reserved. 2024/07/12 Subject to change without notice
MS165-42 2/8

Customs Tariff Number 85362010

Popular Downloads
Data Sheet, Technical 2CDC131083D0201
Information
Instructions and 2CDC131081M6801
Manuals
Instructions and 2CDC131060M0202
Manuals (Part 2)
Ex Operating 2CDC131087M6801
Instructions
Time-Current 1SAM400505F0005
Characteristic Curve
I²t Characteristic 1SAM400506F0001
Cut-off Current 1SAM400507F0001
Characteristic
CAD Dimensional 2CDC001079B0201
Drawing
Dimension Diagram 1SAM400401F0001

Dimensions
Product Net Width 55 mm
Product Net Height 142.65 mm
Product Net Depth / 122.1 mm
Length
Product Net Weight 0.97 kg

Technical
Rated Service Short- (230 V AC) 50 kA
Circuit Breaking (250 V DC) 3 Poles in Series 100 kA
Capacity (I cs ) (400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
Rated Ultimate Short- (230 V AC) 50 kA
Circuit Breaking (250 V DC) 100 kA
Capacity (I cu ) (400 V AC) 50 kA
(440 V AC) 50 kA
(500 V AC) 30 kA
(690 V AC) 10 kA
Rated Instantaneous 630 A
Short-Circuit Current
Setting (I i )
Setting Range 30 ... 42 A
Rated Operational Power (400 V) Three Phase 22 kW
AC-3 (P e )
Rated Operational Power (400 V) Three Phase 22 kW
AC-3e (P e )
Rated Operational Main Circuit 690 V AC
Voltage Main Circuit 250 V DC
Rated Operational 42 A
Current (I e )
Rated Operational 42 A
Current AC-3 (I e )
Rated Operational 42 A
Current AC-3e (I e )

© 2024 ABB. All rights reserved. 2024/07/12 Subject to change without notice
MS165-42 3/8

Rated Operational 42 A
Current DC-5 (I e )
Rated Frequency (f) Main Circuit 50 Hz
Main Circuit 60 Hz
Operating Frequency (f 0 ... 415 Hz
sw )
Rated Impulse Main Circuit 8 kV
Withstand Voltage (U imp
)
Rated Insulation Voltage 1000 V
(U i )
Power Loss at Rated Operating Conditions per Pole 2.79 ... 5.47 W
Number of Poles 3
Conventional Free-air Main Circuit 42 A
Thermal Current (I th )
Degree of Protection Housing IP20
Main Circuit Terminals IP10
Pollution Degree 3
Electrical Durability 25000 cycle
Mechanical Durability 50000 cycle
Terminal Type Screw Terminals
Connecting Capacity Flexible with Ferrule 1/2x 1 ... 35 mm²
Main Circuit Flexible with Insulated Ferrule 1/2x 1 ... 35 mm²
Flexible 1/2x 1 ... 35 mm²
Rigid 1/2x 1 ... 4 mm²
Solid 1/2x 1 ... 4 mm²
Stranded 1/2x 1 ... 50 mm²
Tightening Torque Main Circuit 4 N·m
Wire Stripping Length Main Circuit 16 mm
Recommended Screw Pozidriv 2
Driver
Mounting Position 1 ... 6
Mounting on DIN Rail TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715
TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Minimum Mounting Electrical Conductive Board, Horizontal - Up to 1000 V 1.5 mm
Distance Electrical Conductive Board, Horizontal - Up to 400 V 0 mm
Electrical Conductive Board, Horizontal - Up to 690 V 1.5 mm
Electrical Conductive Board, Vertical 75 mm
Other Device Same Type, Horizontal 0 mm
Other Device Same Type, Vertical 150 mm
Actuator Type Rotary Handle
Contact Position ON / OFF / TRIP
Indication
Standards CSA 22.2 No. 14
IEC/EN 60947-1
IEC/EN 60947-2
IEC/EN 60947-4-1
UL 60947-4-1

Technical UL/CSA
Short-Circuit Current Manual Self-Protected Combination Controllers (Type E), (480Y / 277 V AC)
Rating (SCCR) 65 kA
Manual Self-Protected Combination Controllers (Type E), (600Y / 347 V AC)
30 kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (480 V AC) 65
kA
Any UL Listed Fuses or Circuit-Breakers, Group Installations (600 V AC) 30
kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (480 V AC) 65
kA
Any UL Listed Fuses or Circuit-Breakers, Motor Disconnect (600 V AC) 30

© 2024 ABB. All rights reserved. 2024/07/12 Subject to change without notice
MS165-42 4/8

kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in
Group Installations (480Y / 277 V AC) 65 kA
Any UL Listed Fuses or Circuit-Breakers, Tap Conductor Protection in
Group Installations (600Y / 347 V AC) 30 kA
Maximum Operating Main Circuit 600 V AC
Voltage UL/CSA
Horsepower Rating (200 V AC) Three Phase 10 Hp
UL/CSA (208 V AC) Three Phase 10 Hp
(220 ... 240 V AC) Three Phase 15 Hp
(440 ... 480 V AC) Three Phase 30 Hp
(550 ... 600 V AC) Three Phase 40 Hp
Full Load Amps Motor (200 V AC) Three Phase 32.2 A
Use (208 V AC) Three Phase 30.8 A
(220 ... 240 V AC) Three Phase 42 A
(440 ... 480 V AC) Three Phase 40 A
(550 ... 600 V AC) Three Phase 41 A
Locked Rotor Amps (200 V AC) Three Phase 186.3 A
(208 V AC) Three Phase 179 A
(220 ... 240 V AC) Three Phase 232 A
(440 ... 480 V AC) Three Phase 218 A
(550 ... 600 V AC) Three Phase 232 A
General Use Rating (600 V AC) 42 A
UL/CSA
Connecting Capacity Flexible 1/2x 16-0 AWG
Main Circuit UL/CSA Stranded 1/2x 16-0 AWG
Tightening Torque Main Circuit 35 in·lb
UL/CSA

Environmental
Ambient Air Operation -25 ... +60 °C
Temperature Operation Compensated -25 ... +60 °C
Storage -50 ... +80 °C
Ambient Air Yes
Temperature
Compensation
Maximum Operating 2000 m
Altitude Permissible
Resistance to Shock acc. 11 ms Pulse 25g
to IEC 60068-2-27
Resistance to Vibrations Mounted on Mounting Plate: 5g 3 ... 150 Hz
Mounted on DIN-Rail: 4g 3 ... 150 Hz

Material Compliance
Conflict Minerals 9AKK108467A5658
Reporting Template
(CMRT)
REACH Declaration 1SAA963005-4502
RoHS Information 1SAA963006-4502
RoHS Status Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
Toxic Substances 2CMT2023-006539
Control Act - TSCA
WEEE B2C / B2B Business To Business
WEEE Category 5. Small Equipment (No External Dimension More Than 50 cm)

Circular Value
End of Life Instructions 1SAC00284H0001

© 2024 ABB. All rights reserved. 2024/07/12 Subject to change without notice
MS165-42 5/8

Certificates and Declarations


ABS Certificate 1SAA963002-0101
ATEX Certificate 1SAA918001-3901
BV Certificate 1SAA963002-0201
CB Certificate 1SAA918002-2002
CQC Certificate CQC2015010307760141
Cut-off Current 1SAM400507F0001
Characteristic
Declaration of 2020980307003042
Conformity - CCC
Declaration of 1SAD101100-3408
Conformity - CE
Declaration of 1SAD201100-3408
Conformity - UKCA
DNV GL Certificate 1SAA963002-0301
EAC Certificate 1SAA963000-2701
I²t Characteristic 1SAM400506F0001
IECEx Certificate 1SAA918000-4001
KC Certificate 1SAA963001-1501
LR Certificate 1SAA918001-0501
RMRS Certificate 1SAA918000-0704
UL Certificate E137861-20150206
E345003-20150206

Container Information
Package Level 1 Units box 1 piece
Package Level 1 Width 64 mm
Package Level 1 Depth / 177 mm
Length
Package Level 1 Height 140 mm
Package Level 1 Gross 1.1 kg
Weight
Package Level 1 EAN 4013614486098
Package Level 2 Units carton 12 piece
Package Level 2 Width 330 mm
Package Level 2 Depth / 400 mm
Length
Package Level 2 Height 320 mm
Package Level 2 Gross 13 kg
Weight
Package Level 2 EAN 4013614503955

Classifications
Object Classification F
Code
ETIM 5 EC000074 - Motor protective circuit-breaker
ETIM 6 EC000074 - Motor protection circuit-breaker
ETIM 7 EC000074 - Motor protection circuit-breaker
ETIM 8 EC000074 - Motor protection circuit-breaker
eClass V11.0 : 27370401
UNSPSC 39121521

© 2024 ABB. All rights reserved. 2024/07/12 Subject to change without notice
MS165-42 6/8

IDEA Granular Category 4731 >> Manual Starters


Code (IGCC)
E-Number (Finland) 3707288
E-Number (Sweden) 3110055

Accessories
Unit Of
Identifier Description Type Quantity
Measure
1SAM201901R1001 HKF1-11 Aux.-contact for front mounting HKF1-11 1 piece
HKF1-11K Aux.-contact for frontmounting with
1SAM201901R1201 HKF1-11K 1 piece
Push-In terminals
1SAM201901R1002 HKF1-20 Aux.-contact 2NO, front mounting HKF1-20 1 piece
HKF1-20K Aux.-contact for frontmounting with
1SAM201901R1202 HKF1-20K 1 piece
Push-In terminals
1SAM201901R1004 HKF1-01 Aux.-contact for front mounting HKF1-01 1 piece
1SAM201901R1003 HKF1-10 Aux.-contact for front mounting HKF1-10 1 piece
1SAM201902R1002 HK1-20 Aux.-contact 2 NO HK1-20 1 piece
HK1-20K Aux.-contact 2 NO with Push-In
1SAM201902R1202 HK1-20K 1 piece
terminals
1SAM201902R1001 HK1-11 Aux.-contact 1 NO + 1 NC HK1-11 1 piece
HK1-11K Aux.-contact 1 NO + 1 NC with Push-In
1SAM201902R1201 HK1-11K 1 piece
terminals
1SAM201902R1003 HK1-02 Aux.-contact 2 NC HK1-02 1 piece
HK1-02K Aux.-contact 2 NC with Push-In
1SAM201902R1203 HK1-02K 1 piece
terminals
1SAM201902R1004 HK1-20L Aux.-cont. w. 2 lead contacts 2 NO HK1-20L 1 piece
HK1-20LK Aux-cont. w. 2 leading contacts 2 NO,
1SAM201902R1204 HK1-20LK 1 piece
with Push-In terminals
1SAM201903R1002 SK1-20 Signaling Contact 2 NO SK1-20 1 piece
SK1-20K Signaling Contact 2 NO with Push-In
1SAM201903R1202 SK1-20K 1 piece
terminals
SK1-20AR Signaling Contact, 2NO with screw
1SAM201903R1005 SK1-20AR 1 piece
terminals
SK1-20ARK Signaling Contact, 2NO with Push-
1SAM201903R1205 SK1-20ARK 1 piece
in Spring terminals
1SAM201903R1001 SK1-11 Signaling Contact 1 NO + 1 NC SK1-11 1 piece
SK1-11K Signaling Contact 1 NO + 1 NC with
1SAM201903R1201 SK1-11K 1 piece
Push-In terminals
SK1-11AR Signaling Contact, 1NO+1NC with
1SAM201903R1004 SK1-11AR 1 piece
screw terminals
SK1-11ARK Signaling Contact, 1NO+1NC with
1SAM201903R1204 SK1-11ARK 1 piece
Push-in Spring terminals
1SAM201903R1003 SK1-02 Signaling Contact 2 NC SK1-02 1 piece
SK1-02K Signaling Contact 2 NC with Push-In
1SAM201903R1203 SK1-02K 1 piece
terminals
SK1-02AR Signaling Contact, 2NC with screw
1SAM201903R1006 SK1-02AR 1 piece
terminals
SK1-02ARK Signaling Contact, 2NC with Push-
1SAM201903R1206 SK1-02ARK 1 piece
in Spring terminals
1SAM301901R1002 CK1-20 Short-Circuit Signaling Contact 2 NO CK1-20 1 piece
CK1-11 Short-Circuit Signaling Contact 1 NO + 1
1SAM301901R1001 CK1-11 1 piece
NC
1SAM301901R1003 CK1-02 Short-Circuit Signaling Contact 2 NC CK1-02 1 piece
1SAM201910R1001 AA1-24 Shunt Trip 20-24V AA1-24 1 piece
1SAM201910R1002 AA1-110 Shunt Trip 110V AA1-110 1 piece
1SAM201910R1003 AA1-230 Shunt Trip 200-240V AA1-230 1 piece
1SAM201910R1004 AA1-400 Shunt Trip 350-415V AA1-400 1 piece

© 2024 ABB. All rights reserved. 2024/07/12 Subject to change without notice
MS165-42 7/8

UA1-20 Undervoltage release 20V 50Hz / 24V


1SAM201904R1010 UA1-20 1 piece
60 Hz
1SAM201904R1001 UA1-24 Undervoltage release 24 V UA1-24 1 piece
1SAM201904R1002 UA1-48 Undervoltage release 48V UA1-48 1 piece
1SAM201904R1003 UA1-60 Undervoltage release 60V UA1-60 1 piece
UA1-110 Undervoltage release 110V 110V
1SAM201904R1004 UA1-110 1 piece
50Hz/120V 60Hz
1SAM201904R1008 UA1-208 Undervoltage release 208V 60Hz UA1-208 1 piece
UA1-230 Undervoltage release 230 V 50 Hz /
1SAM201904R1005 UA1-230 1 piece
240 V 60 Hz
1SAM201904R1006 UA1-400 Undervoltage release 400V UA1-400 1 piece
UA1-415 Undervoltage release 415V 415V
1SAM201904R1007 UA1-415 1 piece
50Hz/480V 60Hz
1SAM201904R1009 UA1-575 Undervoltage release 575V 60Hz UA1-575 1 piece
S2-M3-50 3-phase Power infeed Block for
1SAM401923R1003 S2-M3-50 1 piece
MS165, 50 mm²
PS2-2-0-125 3-phase busbar for 2 MS165,
1SAM401920R1002 PS2-2-0-125 1 piece
Ie=125A
PS2-3-0-125 3-phase busbar for 3 MS165,
1SAM401920R1003 PS2-3-0-125 1 piece
Ie=125A
PS2-4-0-125 3-phase busbar for 4 MS165,
1SAM401920R1004 PS2-4-0-125 1 piece
Ie=125A
PS2-2-2-125 3-phase busbar for 2 MS165 with 2
1SAM401920R1022 PS2-2-2-125 1 piece
HK/SK, Ie=125A
PS2-3-2-125 3-phase busbar for 3 MS165 with 2
1SAM401920R1023 PS2-3-2-125 1 piece
HK/SK, Ie=125A
PS2-4-2-125 3-phase busbar for 4 MS165 with 2
1SAM401920R1024 PS2-4-2-125 1 piece
HK/SK, Ie=125A
1SAM401921R1001 BS2-3 Protection Cover for busbars BS2-3 1 piece
1SAM401922R1001 KA165 Terminal Shroud for MS165/MO165 KA165 1 piece
GJF1101903R0002 SA2 Terminals and Installation Material SA2 1 piece
MSHD-LTB Handle, IP64, black, 3 times
1SAM201920R1011 MSHD-LTB 1 piece
lockable, defeatable, 0-TRIP-I
MSHD-LTY Handle, IP64, red/yellow, 3 times
1SAM201920R1012 MSHD-LTY 1 piece
lockable, defeatable, 0-TRIP-I
MSH-AR Shaft alignment ring suitable for
1SAM201920R1000 MSH-AR 1 piece
MSHD and MSH handles
MSMN Driver w. screw for manual motor
1SAM101923R0002 MSMN 1 piece
staters, 6x6
MSMNO Driver w/o coding w. screw for manual
1SAM101923R0012 MSMNO 1 piece
motor staters, 6x6
1SCA101647R1001 OXS6X85 SHAFT OXS6X85 1 piece
1SCA108043R1001 OXS6X105 SHAFT OXS6X105 1 piece
1SCA101655R1001 OXS6X130 SHAFT OXS6X130 1 piece
1SCA101659R1001 OXS6X180 SHAFT OXS6X180 1 piece

Categories

© 2024 ABB. All rights reserved. 2024/07/12 Subject to change without notice
MS165-42 8/8

Low Voltage Products and Systems → Circuit Breakers → Manual Motor Starters
Low Voltage Products and Systems → Control Products → Manual Motor Starters → Manual Motor Starters

© 2024 ABB. All rights reserved. 2024/07/12 Subject to change without notice

You might also like