PORTABLE TYPE

ULTRASONIC FLOWMETER
DATA SHEET FSC-4, FSS, FSD
Portable type ultrasonic flowmeter consists of a compact
and lightweight flow transmitter and a clamp-on detector.
With the latest electronics and the digital signal processing
technology, it delivers precise measurement while allowing
easy operation.
New features: renewed panel design, improved display
visibility and connector reliability, and more accessories. Flow transmitter (FSC)

FEATURES
1. Compact and lightweight
The adoption of the latest electronics and digital
signal processing technologies has reduced the size
and weight of the flow transmitter by 30% and 30%,
respectively, in comparison with the Fuji conventional
portable flowmeter (Model FSC). (in comparison to Detector (FSSC) Large diameter type
our existing model) (FSSE)
2. Battery operation
The flowmeter is designed for 12 hours of continu-
ous operation via built-in battery which is recharge-
able in 3 hours with the exclusive power adapter.
3. Full variety of detectors
The flowmeter is suitable for various types of detec- High-temperature type (FSSH) Small diameter type
tors applicable for small to large diameter pipe (pipe (FSSD)
inner diameter ø13 to ø6000mm) and low to high
temperature (−40 to +200°C).
4. High accuracy and high-speed response 10. Graphic printer connection (option)
The flowmeter is designed for high accuracy Easy recording with the Integral type printer.
(±1.0%). 11. Flow velocity profile measurement (option)
Response time is within 1 second. Flow profile may be observed in real time.
5. Improved anti-bubble characteristic
Anti-bubble characteristic is greatly improved by
digital signal processing.
SPECIFICATIONS
6. Excellent performance and easy operation
Measuring objects
Large graphic LCD that is outside but easy to read.
Minimum number of function keys are used for page Measurement fluid:
selection, allowing easy setting. Uniform liquid in which ultrasonic
While battery is working, the flowmeter is water waves can propagate.
resistant and tolerates exposure to rain. Turbidity of fluid: 10000 mg/L or less
7. Large capacity storage by SD memory card State of fluid: Well-developed turbulent or laminar
Measured data is periodically stored in SD memory flow in a filled pipe.
Fluid temperature: −40 to +200°C
card. For example, in the case of 512MB (option), it
Measuring range: 0···±0.3 to ±32m/s
can be saved about 2 year measurement date(In case
of saving period 30 seconds, 14 kinds of saved data).
Piping conditions
Available up to 8MB.
8. Serial communication Applicable piping material:
Use of a USB port allows easy connection to a per- Select from carbon steel, stainless
sonal computer. Measured date collection panel and steel, cast iron, PVC, FRP, copper,
Loader software for PC (standard) which is available aluminum, acrylic or material of known
for display and change of parameter (site setting) are sound velocity.
prepared. Pipe size: Flow rate measurement
9. Heat quantity (calorie) measurement ø13 to ø6000mm
Heat quantity (calorie) may be measured by tem- Flow velocity profile measurement
perature input, making energy management easy for ø40 to ø1000mm
cooling and heating.
EDS6-153b
Date May 31, 2019
FSC-4, FSS, FSD

Lining material: Select from no lining, tar epoxy, Analog output signals:
mortar, rubber, Teflon, pyrex glass or 4 to 20mA DC, one point (load resis-
material of known sound velocity. tance, 600Ω or less)
Note) No gap allowed between the Instantaneous velocity, instantaneous
lining and the pipe. flow rate or heat quantity (calorie) after
Straight pipe length: scaling.
10D or more upstream and 5D or more Analog input signal:
downstream (D: internal pipe diameter) 4 to 20mA DC, one point (in-
Refer to Japan Electric Measuring In- put resistance, 200Ω or less)
Total
struments Manufactures’ Association’s 4 to 20mA DC, one point (in- 2 points
standard JEMIS-032 for details. put resistance, 200Ω or less)
or 1 to 5V DC, one point
Performance specifications Used to input temperature for heat
quantity measurement, etc.
Accuracy rating:
SD memory card: Used for data logger function and
Pipe inner Flow velocity Accuracy
diameter range
recording screen data.
Available up to 8GB (Option256MB)
ø13 to ø50mm 2 to 32m/s ±1.5% to 2.5% of rate
0 to 2m/s ±0.03m/s Compliant media
ø50 to ø300mm 2 to 32m/s ±1.0% to 1.5% of rate • SD memory card: speed class 2, 4, 6
0 to 2m/s ±0.02 to 0.03m/s • SDHC memory card: speed class 4, 6
ø300 to ø6000mm 1 to 32m/s ±1.0% to 1.5% of rate Format
0 to 1m/s ±0.01 to 0.02m/s • FAT16: 64MB to 2GB
Note1) Reference conditions are based on JEMIS-032. • FAT32: 4GB, 8GB
Note2) Refer to the 4 pages for the accuracy according to kind Otherwise, reading and saving are
of detector. impossible.
File format
Flow transmitter (Type: FSC) • Date logger: CSV file
Power supply: Built-in battery or AC power adapter • Screen date: Bit map file
Built-in battery: Exclusive lithium button battery The SDXC memory card is not supported.
(5000m Ah) Serial communication:
Continuous operation time, approx. 12 USB port (device* compatible):
hours (without printer, back light OFF, Mini B receptacle, USB 2.0
output current not used and at normal Connectable number of Mini B recep-
ambient temperature (20°C)) tacles:
Recharging time, approx. 3 hours 1 unit
(power adapter used) Transmission distance: 3m max.
Recharging temperature range: 0 to Transmission speed: 500kbps
+40°C Data:
Power consumption: Min. 3W and Instantaneous velocity, instanta-
Max. 16W neous flow rate, total value, heat
The consumption varies depending on quantity (calorie) value, error infor-
the use conditions. mation, logger data, etc.
Power adapter: Exclusive power adapter 100V to 240V * Device: Connected plug from PC
+10%/−15% AC (50/60Hz), 90VA or Printer (option): To be mounted on top of transmitter unit
less. Thermal line dot printing
Display: TFT color graphic LCD Note) When the Chinese display is selected,
240 × 320 (with back light) printing is made in kanji characters.
Measurement value (instantaneous Ambient temperature:
flow rate, integrated flow rate) and −10 to +55°C (Without printer)
various settings are displayed. −10 to +45°C (With printer)
Excellent visibility even outdoors in Ambient humidity: 90%RH or less
direct sunlight. Type of enclosure: IP64 (Without printer)
LED display: Status display when using AC power Enclosure case: Plastic case
adapter. Outer dimensions: H210 × W120 × D65mm (Without printer)
DC IN (green): Power supply status H320 × W120 × D65mm (With printer)
CHARGE (red): Battery charging under- Weight: 1.0kg (Without printer)
way 1.2kg (With printer)
Operation keypad:
11 buttons Functions
(ON, OFF, ENT, ESC, MENU, , , , Display language: Selectable from Japanese, English,
, LIGHT, PRINT) German, French, Spanish or Chinese
Power failure backup: (switchable by key operation).
Measurement value is backed up by Clock display function:
nonvolatile memory. Time (year, month, day, hour, minute)
Clock backup with lithium battery display (configurable)
(effective term, 10 years or more) Monthly error: about 1 minutes at nor-
Response time: 1 second mal temperature (20°C).

2
Instantaneous value display function: Temperature display function:
Instantaneous velocity, instantaneous Fluid temperature be displayed by cur-
flow rate display (The flow in reverse rent input from temperature transmit-
direction is displayed with minus “−.”) ter.
Numeric value: 10 digits (decimal point Metric system
equals 1 digit) Temperature unit: °C or K
Unit: Metric/English system selectable English system
Metric system Temperature unit: °F or K
Velocity: m/s Site data storage function:
Flow rate: L/s, L/min, L/h, L/d, kL/d, Max. 32 locations (sites) data (pipe
ML/d, m3/s, m3/min, m3/h, size, material, fluid type and etc) can
m3/d, km3/d, Mm3/d, BBL/s, be stored into built-in non-volantile
BBL/min, BBL/h, BBL/d, memory.
kBBL/d, MBBL/d Damping: 0 to 100sec (every 0.1sec) configurable
English system for analog output and velocity/flow
Velocity: ft/s rate display
Flow rate: gal/s, gal/min, gal/h, gal/d, Low flow cut: Equivalent to 0 to 5m/s
kgal/d, Mgal/d, ft3/s, ft3/min, Output setting function:
ft3/h, ft3/d, kft3/d, Mft3/d, Current output scaling, output type,
BBL/s, BBL/min, BBL/h, burnout setting and calibration
BBL/d, kBBL/d, MBBL/d Serial communication function:
Total value display function: Instantaneous velocity, instantaneous
Display of forward or reverse total flow rate, total value, heat flow, er-
(reverse is displayed as minus) ror information, received waveform,
Numeric value: 10 digits (decimal point analog input, velocity profile data,
is corresponding to 1 digit) logger data, etc. may be downloaded
Unit: Metric/English system selectable to personal computer.
Metric system Logger function: Instantaneous velocity, instantaneous
Flow rate total: mL, L, m3, km3, Mm3, flow rate, total value, heat flow, error
mBBL, BBL, kBBL information, received waveform, ana-
English system log input, velocity profile date can be
Flow rate total: gal, kgal, ft 3, kft3, Mft3, saved in a SD memory card.
mBBL, BBL, kBBL, ACRE-ft Waveform display function:
Consumed heat quantity (calorie) display function: Bi-directional received waveforms may
Display of consumed heating medium be displayed.
Metric system Graph display function:
Heat flow: MJ/h, GJ/h Flow rate trend graph may be dis-
Total heat quantity: MJ, GJ played.
English system Printing function (option):
Heat flow: MJ/h, GJ/h, BTU/h, kBTU/h, Hard copy output of a screen
MBTU/h, kW, MW Periodic printing (type: text, graph)
Total heat quantity: Logger date (type: text, graph)
MJ, GJ, BTU, kBTU, MBTU, Flow velocity profile measurement (option):
kWh, MWh Flow velocity profile may be observed
J : Joule in real time using the exclusive detec-
BTU : British thermal unit tor (option).
W : Watt (Refer to page 5 for details.)
Computation function of consumed heat quantity (calorie):
This function calculates the heat Detector (Type: FSS)
quantity received and sent with liquid
Type of detector:
(water) in cooling and heating.
Classification Type Internal pipe Fluid Frequency
diameter (mm) temperature (MHz)
Middle diameter FSSC ø50 to ø1200 (*1) -40 to 120°C 1
Consumed heat quantity
q = K · Q · (T1–T2) Small diameter FSSD ø13 to ø300 -40 to 100°C 2
Converter
K : heat quantity (calorie) Large diameter FSSE ø200 to ø6000 -40 to 80°C 0.5
conversion factor
(For heating K = 4.123, High temperature FSSH ø50 to ø400 -40 to 200°C 2
Temperature
For cooling = 4.186)
sensor *1) For pipes with a diameter of 300 mm or larger, we recommend to use FSSE
and mount it by Z method.
T1: Fluid temperature
(inlet) Mounting method: Mounting on outside of pipe
Sensor mounting method:
exchanger

V or Z method
source

Heat
Heat

Signal cable: Exclusive coaxial cable, 5m (Included with


Converter
FSC)
Detector
Temperature
(type : FSS)
Connection method:
sensor
Transmitter side: Exclusive connector
Detector side (FSSE): Screw terminal
T2: Fluid temperature (outlet) Q: Flow rate of the fluid Others: BNC connector
3
FSC-4, FSS, FSD

Ambient temperature:
–20 to +60°C
MEASURING PRINCIPLE
Ambient humidity: With ultrasonic pulses propagated diagonally between the
FSSE 100%RH or less upstream and downstream sensors, flow rate is measured by
Other 90%RH or less detecting the time difference obtained by the flow of fluid.
Type of enclosure: Detector
Upstream sensor
FSSC IP65
(When waterproof BNC con-
nector is provided) θ Output
D Flow signal
FSSE IP67 t2 trans-
Flow t1 mitter
Others IP52 velocity V
Water-proof treatment type IP68
Downstream sensor
(Submerged resistant struc-
ture for 5 days)
Material of detector: MOUNTING OF DETECTOR
Classification Type Sensor Rail material PZT oscillator Plastic wedge
case Pipe
Small diameter FSSD Plastic Aluminum alloy + Plastic
Middle diameter FSSC Plastic Aluminum alloy + Plastic Lining
Large diameter FSSE Plastic ———
High temperature FSSH SUS304 Aluminum alloy

Material of mounting belt/wire:


Detector type Dimensions Material
6th digit
A 1.5mX2 SUS304
CONFIGURATION DIAGRAM
(1) When V method is used for mounting
B 3.0mX1 Plastic cloth belt
C 1.0mX4 SUS304 Cable

D Inner pipe diam.<ø1500mm SUS304


Detector
E Inner pipe diam.<ø6000mm SUS304
4 to 20mA

transmitter
DC
Extension cable(option):

Flow
Extended when the length of the detec-
tor signal cable is not sufficient.
Length: 10m, 50m (2) When Z method is used for mounting
Cable

Detector
transmitter

4 to 20mA
DC
Flow

DETECTOR SELECTION GUIDE (ACCURACY % of rate)


Inner diameter of piping ø[mm]
Mounting
TYPE
method 13 25 50 100 150 200 250 300 400 600 1200 3000 6000

V*2) ±1.5
to 2.5 ±1.0
FSSD
Z *1)
±1.0

V ±1.5 ±1.0
FSSC
Z ±1.0

V ±1.5 ±1.0
FSSE
Z ±1.5 ±1.0

V ±1.0
FSSH
Z*1) ±1.0

*1) When FSSD or FSSH is mounted using the Z method, guide rail (option) is required additionally.
*2) For the pipe inner diameter of ø13mm, the sensor mounting dimension may be 0.0mm or less depending on pipe material and thickness.
When the sensor mounting dimension is 0.0mm or less,measurement error is about 2 to 5%.
<Description of the table> Required min. pipe thickness (fluid: water) (Unit: mm)
It shows pipe thickness of each material that the sensor mounting Steel pipe 2.15 or more FRP 3.21 or more
size is to be 0.0mm, when fixing a pipe. If the fluid is the one other Stainless pipe 1.87 or more Ductile cast iron 2.15 or more
than water, and if the sound velocity of fluid is faster than the one PVC pipe 3.69 or more PEEK 3.69 or more
of water, the sensor mounting size is to be 0.0mm or more. Copper pipe 3.82 or more PVDF 3.69 or more
Cast-iron pipe 2.98 or more Acrylic pipe 2.90 or more
Aluminum pipe 1.99 or more Polypropylene 3.69 or more

4
FLOW VELOCITY PROFILE DISPLAY FUNCTION MEASUREMENT PRINCIPLE
<Pulse Doppler method>
(OPTION) Ultrasonic pulses are transmitted through the fluid flow.
Entrained bubbles and microscopic particles within the
Pulse Doppler method enables the analysis and display of
fluid create frequency phase shifts (Doppler effect.) The
the flow velocity profile in real time. The results can be used
resulting doppler shifts are integrated across the inside
to decide the appropriate measurement location, for flow
pipe diameter cross section. The resulting profile curve is a
diagnosis, and laboratory test.
real-time dynamic display of the flow profile within the pipe.

SPECIFICATIONS
Measuring fluid: Uniform liquid in which ultrasonic Sensor 1 (FSD)
waves can propagate.
Turbidity of fluid: Axisymmetric flow in a filled pipe.
Fluid temperature: Air Flow
bubbles
−40 to +100°C (FSDP2) Reflection
−40 to +80°C (FSDP1,FSDP0)
Sensor 2
Air bubble quantity: (FSD)
0.02 to 15vol% (Velocity is 1m/s)
Flow Flow
Pipe size: Small type sensor : ø40 to ø200mm velocity velocity
Middle type sensor :ø100 to ø400mm Profile 2 Profile 1
Flow velocity
Large type sensor :ø200 to ø1000mm
Measurement range:
0 to ±0.3 … ±Maximum Velocity (de- Piping wall Center Piping wall
pending on the pipe diameter)
Refer to tables 1 and 2. The above shows an example when using two sensors.
Note) This function is to observe flow One detector displays the flow velocity profile for a ra-
velocity profile, and it may be different dius.
from actual flow rate.

DETECTOR FOR FLOW VELOCITY PROFILE BLOCK DIAGRAM


MEASUREMENT (TYPE: FSDP) (1) Using one sensor

Mounting method: Cable


Power
on outside of existing pipe supply
Ambient temperature: −20 to +80°C Sensor (FSD)
Ambient humidity: 100% RH or less
Enclosure: IP67 (waterproof BNC connector Flow
required.) Transmitter
Material: Sensor housing: PBT
Guide frame: Aluminum alloy
Mounting belt: Plastic cloth or stain-
less (2) Using two sensors
Power
Cable supply
Sensor (FSD)

Flow
Transmitter

Sensor (FSD)

5
FSC-4, FSS, FSD

Table 1 PC Loader Software


Measurement range of pulse Doppler method varies with
The software allows you to view and edit parameter setpoints
the pipe outer diameter, wall thickness, material, and kind
on your PC, and to load the following data: instantaneous
of fluid. When the pipe material is stainless steel, the pipe
flow rate, instantaneous velocity, error information, received
schedule is 20s, and fluid is water, the ranges for each
waveform, analog input, and log data.
detector are as follows.
PC requirements: PC/AT compatible machine
Maximum measurable flow velocity Maximum measurable flow rate Free hard disc capacity: 128 MB or more
Unit: m/s Unit: m3/h Memory capacity: 52 MB or more
Diameter FSDP2 FSDP1 FSDP0 FSDP2 FSDP1 FSDP0
The operating systems on which we have tested this
40A 6.56 33.6
software are: Microsoft Windows 7/8.1/10
50A 6.52 52.7
65A 5.31 72.1 Interface: USB 2.0
80A 4.65 86.5
90A 4.12 102
100A 3.69 7.25 118 231 EU Directive Compliance
125A 3.08 6.08 147 289
EMC (2014/30/EU)
150A 2.63 5.20 179 354
EN 61326-1 (Table 2)
200A 2.04 4.05 7.77 239 474 908
250A 3.30 6.38 604 1168 EN 55011 (Group 1 Class A)
300A 2.78 5.41 735 1428 EN 61000-3-2 (Class A)
350A 2.51 4.90 820 1598 EN 61000-3-3
400A 2.20 4.31 951 1858 EN 61326-2-3
450A 3.80 2118 RoHS (2011/65/EU)
500A 3.48 2358 EN 50581
550A 3.17 2618
600A 2.91 2879
650A 2.71 3096
700A 2.52 3357
750A 2.35 3618
800A 2.21 3879
850A 2.08 4140
900A 1.97 4400
1000A 1.77 4902

CODE SYMBOL
<Flow transmitter> <Detector>
1 2 3 4 5 6 7 8 9 10 11 (for transit time)
F SCS 4 - 0 Description 1 2 3 4 5 6 7 8 9 10

<Specification> F SSC1 1 Description


S Standard <Senser type>(4th digits)
<Converter> C ø50 to ø1200mm
1 Basic system <Guide rail>(5th digits)
2 Basic system + Printer Provided (Extendable rail type)
1
<Flow velocity profile measurement>
<Mounting belt>(6th digits) *2
0 None Y None
1 Provided (detector to measure flow A Stainless belt (1.0m×2)
velocity profile is separately required.) B Plastic cloth belt (3m×1)
<Power adapter> C SS belt fasten with screws (1.0m×4)
A AC power + power cord (125V AC) for D Wire ≤ ø1500mm
Japanese and North American use <Acoustic coupler> (7th digit) *1
B AC power + power cord (250V AC) for Y None
European and Korean use B Silicone-free grease (HIGH-Z)
C AC power + power cord (250V AC) for C Silicone grease (G40M)
Chinese use
<Water-proof treatment>(9th digit)
4 Modification No. Y None
<SD memory card> B Provided (with signal cable 10m)
0 None *Submersible in water for 5 days
1 Provided (512MB) <Tag plate> (10th digit)
Y None
<Bound instruction manual/Language>
A Provided
Y None (Factory-set language: English)
J Provided/Japanese *1: Normally select silicone grease as acoustic coupler. Silicone grease is
(Factory-set language: Japanese) tube (100g).
E Provided/English Select silicone-free grease for semiconductor manufacturing
(Factory-set language: English) equipment or the like that is vulnerable to silicone. The silicone-free
C Provided/Chinese grease is water-soluble and, therefore, cannot be used in environment
(Factory-set language: Chinese) exposed to water or on piping subjected to a condensation. Since the
(Note1) Instruction manual contained in CD grease does not set, a periodic maintenance (cleaning, refilling every
is the standard attached article. about 6 months at normal temperature) is necessary.
(Note2) You can change the language by *2: Please refer to the table 2 to serect the mounting belt at 6th digits.
key operation.
[Table 2] How to select at 6th digits.
Mounting method ≤ø300mm ≤ø600mm ≤ø1200mm
V method B, A or C C D
Z method C D D

6
CODE SYMBOL OPTIONAL ITEMS
Name Specifications Arrange-
<Detector> ment No.
(for flow velocity profile measurement) 1 Battery Special type Li-ion battery ZZP*TK7N6384P1
1 2 3 4 5 6 7 8 (7.4V, 2500mAh) *Order in two pairs.
F SD 0 Y 1 Description 2 AC power Special type power adapter and
<Kind> adapter 100 to 240V +10%/−15% AC,
P2 Small type (φ40 to φ200mm) 50/60Hz ZZP*TQ505735C4
P1 Middle type (φ100 to φ400mm)
P0 Large type (φ200 to φ1000mm)
<Terminal mold> 3 Power code Japan, North America:125V AC 2m ZZP*TK7N6621P1
0 None Europe, Korea: 250V AC 2m ZZP*TK7N6608P1
China: 250V AC 2m ZZP*TK7N6609P1
<Structure>
Y General use 4 Printer To be mounted on top of converter ZZP*TK4J2634C1
Thermal serial dot system
1 Modification No. (8 x 384 dot)
5 Printer roll Maker: SEIKO I SUPPLY Co. Ltd. ZZP*TK7N6381P1
paper Type: TP-211C-1
Specifications: Thermal roll paper
SCOPE OF DELIVERY Width: 58mm×ø48mm
6 Silicone Maker: Shin-Etsu Chemical Co., Ltd.
<Flow transmitter : FSC> grease Type:
Name of unit Scope of delivery · For standard use G40M, 100g ZZP*45231N5
· For silicone free 100g ZZP*TK7M0981P1
1 Basic system 1) Conversion unit · For high temperature KS62M, 100g ZZP*TK7P1921C1
2) Power adapter and
Power connector conversion cord 7 Signal cable Special type signal cable, 5m × 2
(connector on both - sides) ZZP*TK7N7795C1
3) Power cord
4) Analog input/output cord (1.5m)
5) USB cable (1m) 8 Extension Special type coaxial cable with BNC
6) Carrying case signal cable connector
7) Strap · 10m × 2 ZZP*TK468664C3
8) Special type signal cable (5m × 2) · 50m × 2 ZZP*TK468664C4
9) CD-ROM (Instruction manual and 9 Analog 6-core cable, 1.5m, with connector ZZP*TQ405191C1
Loader software for PC) input/output
cable
2 Option 1) Printer unit + rolled paper (1 roll)
2) SD memory card (512MB)
3) Bound instruction manual (including
a detector) 10 Mounting belt / · Plastic cloth belt ZZP*TK7G7979C1
wire · Stainless wire
<Detector : FSS, FSD> Nominal diameter
ø200 to ø500mm ZZP*TK7G7980C1
Name of unit Scope of delivery
ø200 to ø1000mm ZZP*TK7G7980C2
1 Detector for propa- 1) Sensor unit ø200 to ø2000mm ZZP*TK7G7980C3
gation time differ- 2) Signal cable conversion code ø200 to ø3000mm ZZP*TK7G7980C4
ence (FSS) (included with FSSE) ø200 to ø6000mm ZZP*TK7G7980C5
3) Mounting belt/wire · Stainless steel belt ZZP*TK7P1943C1
4) Silicone grease (Article specified) 11 Guide rail · Mounting bracket material: ZZP*TK4J5917C3
2 Detector for flow 1) Detector unit for high-tem- Aluminum alloy+SUS304
v e l o c i t y p r o f i l e 2) Mounting belt/wire perature sensor For FSSH
(In mounting by
(FSDP) 3) Silicone grease (100g)
the Z method)
Note 1) Silicon grease is for filling a gap between a detector and a 12 Guide rail for · Mounting bracket material: ZZP*TK4J5917C1
pipe joint area. It is provided with a detector. small type Aluminum alloy+plastic
Since silicon grease does not become hardened, if you use detector For FSSD3 (L=540mm)
it in the long term, periodic maintenance is required. (Under (In mounting by
the condition of room temperature, semiannual cleaning and the Z method)
refill is recommended.)
Note 2) When you order a detector alone, an instruction manual is 13 SD memory Maker: Panasonic, Inc. ZZP*TK7N7680P1
not provided. Please request, if necessary (Onerous). card Type: RP-SDFC51CD1
Capacity: 512MB
14 USB cable Maker: Sunwa Supply Inc. ZZP*TK7N6622P1
Type: KU-AMB510
Specifications: Mini USB cable
Hand strap (1.0m)
15 Signal cable M4 clamp terminal / BNC jack, ZZP*TK4K6304P1
conversion cord L=150mm
16 Hand strap To be attached on the side of trans- ZZP*TQ505739C1
Stand mitter.
Strap length: 200 mm

17 Stand Holds the transmitter at 45 degree ZZP*TQ405196P1


Note: The hand strap and the stand cannot be angle
used simultaneously.

7
FSC-4, FSS, FSD

Diagram To connect signal cables for FSSC, FSSD, FSSH, FSDP2, FSDP1, FSDP0
BNC
connector

Printer Detector
(option)

Signal cable To connect signal cables for FSSE


Conversion
cord
Detector input BNC connector Detector
(the downstream side)
Flow
transmitter Detector input
(the upstream side)
Analog input/output cable
AO analog output 4 to 20mA DC
AICH1 analog input 4 to 20mA DC or 1 to 5 V DC
AICH2 analog input 4 to 20mA DC
PC
SD Power connector 100 to 240V AC
Conversion cord
SD memory Power cord
card AC power adaptor

USB cable for use AC adaptor

To connect PC

Pipe requirements
(D: Nominal diameter of pipe)
Type Length of upstream straight pipe Length of downstream straight pipe

L ≥ 5D
10D or more

L ≥ 10D
90° bend

Detector
10D or more

L ≥ 10D
L ≥ 50D
T-shape

10D or more
or more

L ≥ 30D L ≥ 5D
0.5D

Diffuser
D

1.5D or more

L ≥ 10D L ≥ 50D

Tapered

L ≥ 30D L ≥ 10D

Valve

Flow controlled upstream Flow controlled downstream

Isolation valve
Check valve
L ≥ 50D
Pump
P

Note) Source: Japan Electric Measuring Instruments Manufacturers' Association (JEMIS-032)

8
OUTLINE DIAGRAM (Unit:mm)
Flow transmitter

120±1.8 65±1.8

2-M4, Depth5 (both sides)

Sensor (downstream)

DOWNSTREAM

SENSOR
UPSTREAM
210±2.5

Sensor (upstream)

AI/AO
DC12V

Analog input/output

DC power input

Power switch

SD memory card slot USB port

USB

Weight : Approx. 1.0kg

9
FSC-4, FSS, FSD

OUTLINE DIAGRAM (Unit:mm)


Flow transmitter (with printer)

120±1.8 65±1.8

Printer

2-M4, Depth5 (both sides)


Approx. 320±4.5

Sensor (downstream)
DOWNSTREAM

SENSOR
UPSTREAM

Sensor (upstream)
AI/AO

Analog input/output
DC12V

DC power input

Power switch

SD memory card slot USB port

USB

Weight : Approx. 1.2kg

10
OUTLINE DIAGRAM (Unit:mm)
480±2

SPACING: 0 to 300

inch 6 5 4 3 2 1 20 40 60 80 100 120 140 160 mm

mm 160 140 120 100 80 60 40 20 1 2 3 4 5 6 inch

BNC connector
Scale (inch) Scale (mm)
53
BNC CONN. Lock nut

88max.
Sensor unit

54
Rail end Tag plate Name plate Guide rail
Extended rail

<Shipment style (V method)>

Type.
Mfd.
(880)

L
700max.
400max. 240

inch 6 5 4 3 2 1 20 40 60 80 100 120 140 160 mm

mm 160 140 120 100 80 60 40 20 1 2 3 4 5 6 inch

Absorber unit
100 100 100 100

Ser.No.
Extended rail

Made in Japan

<Extended style (Longest, V method)>


Frame
240 240

Rail end (Accessories)

<Sepalate style (Z method)>


(H)

Detecter : Type FSSC

W±1

Weight
Type Diameter (mm) L H W Approx. (kg)
Straight plug BNC Connector
FSDP2 40 to 200 260±1.2 70 57 0.8

FSDP1 100 to 400 260±1.2 72 57 0.9


(ø2.4)

+100 FSDP0 200 to 1000 350±2.0 90 85 2.0


5000 -0
Detector FSDP (Detector for flow velocity profile measurement)

Signal cable
Clip
Straight plug
ø12.3

(ø5.1)

+100
(32.3) 1500 -0 100±5

Code color Clip color Mark


Black (BK) Red (R) (+)
AO
White (W) Black (BK) (−)
Red (R) Red (R) (+)
AI ch1
Green (G) Black (BK) (−)
Yellow (Y) Red (R) (+)
AI ch2
Brown (BN) Black (BK) (−)

Analog input/output cable


11
FSC-4, FSS, FSD

Detector for special application 1) detector for small diameter type


Pipe size: ø13 to 100mm (300mm max.)
Fluid temperature: –40 to 100°C
Type: FSSD□□□ 1-Y□

Specification
• Sensor frequency: 2MHz
• Mounting method: V method, Z method (FSSD3)
• Fluid temperature: –40 to 100°C CODE SYMBOL
• ‌A pplicable pipe material: PVC, SS, carbon steel pipe, <Detector>
copper pipe, aluminum pipe, etc. 1 2 3 4 5 6 7 8 9 10

[In case lining is removed from the pipe, Measurement F S SD 1 Y Description


can not be conducted] <Senser type>(4th digits)
D ø13 to ø100mm
• Rated accuracy of combination with the flow transmitter
<Guide rail>(5th digits)
(Applicable piping: plastic, metal pipe)
1 Provided (L=320mm) ø100mm
Internal diameter Velocity Accuracy 3 Iong rail (L=540mm) ø300mm
(mm) <Mounting belt>(6th digits)
Y None
ø13 to ø50 2 to 32m/s ±1.5% to ±2.5% of rate A Stainless belt (1.5m 2)
0 to 2m/s ±0.03 to ±0.05m/s B Plastic cloth belt (3m 1)
ø50 to ø100 2 to 32m/s ±1.0% of rate C SS belt fasten with screws (1.0m 4)
(ø300) 0 to 2m/s ±0.02m/s <Acoustic coupler> (7th digit)
Y None
A
• Mounting belt: according to specified code of symbol. Silicon rubber (KE348)
B Silicone-free grease (HIGH-Z)
• Material: PBT, guide rail: aluminum alloy + plastic C Silicone grease (G40M)
• Type of enclosure: IP52 <Water-proof treatment>(9th digit)
• Acoustic coupler: according to specified code of symbol. Y None
<Tag plate> (10th digit)
• Mass: 0.6kg, 0.8kg Y None
A Provided

OPTIONAL ACCESSORIES
Name Drawing No.
Sillicon grease (GM40M) ZZP*45231N5
Sillicon-free grease (HIGH-Z) ZZP*TK7M0981P1

Scope of delivery
• Detector, acoustic coupler and set of the mounting belt
according to specified code of symbol
OUTLINE DIAGRAM (unit: mm)
<Detector>
Saddle Saddle
Scale(inch) Scale(mm)
Connector
Connector
mm

Scale Scale
(inch) (mm)
Distance between two

Name prate
sensors 0 to 133

Spacing: 0 to 348
320±2

Lock nut
540±2

Element holder

Lock nut
Cursor
inch

Element holder

Cursor
36
90 max.

36±0.5
90max.

52.5±0.5

52.5±0.5
Weight : Approx. 0.6kg Weight : Approx. 0.8kg

Small diameter sensor: FSSD1 Detector FSSD3


12
Detector for special application 2) detector for high temperature
Pipe size: ø50 to 400mm
Fluid temperature: –40 to 200°C
Type: FSSH1□□1-Y□

Specification
• Sensor frequency: 2MHz
• Mounting method: V method (ø50 to 250mm) or Z method
CODE SYMBOL
(ø150 to 400mm)
<Detector>
• Fluid temperature: –40 to 200°C 1 2 3 4 5 6 7 8 9 10

• A pplicable pipe material: PVC, SS, carbon steel pipe, F S SH1 1 Y Description
copper pipe, aluminum pipe,etc. <Senser type>(4th digits)
H ø50 to ø400mm (-40 to 200°C)
[In case lining is removed from the pipe, Measurement
<Guide rail>(5th digits)
can not be conducted]
1 Provided
• Rated accuracy of combination with the flow transmitter
<Mounting belt>(6th digits)
(Applicable piping: plastic,metal pipe) Y None
A Stainless belt (1.5m×2)
Internal diameter Velocity Accuracy C SS belt fasten with screws (1.0m×4)
(mm) <Acoustic coupler> (7th digit)
ø50 to ø300 2 to 32m/s ±1.0% of rate Y None
0 to 2m/s ±0.02m/s D High-temperature grease (KS62M)
ø300 to ø400 0.75 to 32m/s ±1.0% of rate <Water-proof treatment>(9th digit)
Y None
0 to 0.75m/s ±0.0075m/s
<Tag plate> (10th digit)
Y None
• Mounting belt: according to specified code of symbol.
A Provided
• Material: sensor housing: SUS304
guide rail: SUS304 + aluminum alloy
• Type of enclosure: IP52
• Acoustic coupler: according to specified code of symbol. OPTIONAL ACCESSORIES
• Mass: 1.6kg Name Drawing No.
Guide rail for high-temperature sensor ZZP*TK4J5917C3
(Z method)
High-temperature grease(KS62M) ZZP*TK7G7983C1
OUTLINE DIAGRAM (unit: mm)
<Detector>
Connector Saddle

Scale(inch)
Scope of delivery
Scale(mm)
• Detector, acoustic coupler and set of the mounting belt
according to specified code of symbol

Name plate
two sensors 0 to 330
Distance between

530±2

Lock nut

Element holder

Cursor

ø26 33±0.5
90max.
205max.

44±1

High-temperature sensor: FSSH

13
FSC-4, FSS, FSD

Detector for special application 3) detector for large diameter type


Pipe size: ø200 to 6000mm
Fluid temperature: –40 to 80°C
Type: FSSE1□□1-□□

Specification
• Sensor frequency: 0.5MHz
CODE SYMBOL
• Mounting method: V or Z method
<Detector>
• Fluid temperature: –40 to 80°C 1 2 3 4 5 6 7 8 9 10

• A pplicable pipe material: PVC, SS, carbon steel pipe, F SSE1 1 Description
copper pipe, aluminum pipe,etc. <Senser type>(4th digits)
E ø200 to ø6000mm
* In case lining is removed from the pipe, Measurement <Guide rail>(5th digits)
can not be conducted 1 Provided
• Also applicable to water-proof type according to specified <Mounting belt>(6th digits)
code of symbol (submerged resistant structure for 5days Y None
D Wire ≤ ø1500mm
including 10m cable) E Wire ≤ ø6000mm
• Rated accuracy of combination with the flow transmitter <Acoustic coupler> (7th digit)
(Applicable piping: plastic, metal pipe) Y None
A Silicon rubber (KE348)
Internal diameter Velocity Accuracy B Silicone-free grease (HIGH-Z)
C Silicone grease (G40M)
(mm)
ø200 to ø300 2 to 32m/s ±1.5% of rate <Water-proof treatment>(9th digit)
Y None
0 to 2m/s ±0.03m/s B Provided (with signal cable 10m)
ø300 to ø1200 0.75 to 32m/s ±1.5% of rate <Tag plate> (10th digit)
0 to 0.75m/s ±0.0113m/s Y None
ø1000 to ø6000 1 to 32m/s ±1.0% of rate A Provided

0 to 1m/s ±0.02m/s

• Mounting belt: according to specified code of symbol. OPTIONAL ACCESSORIES


• Material: Sensor housing PBT, Sensor cover SUS304 Name Drawing No.
• Type of enclosure: IP67 Wire rope for mounting the sensor
• Spring ZZP*TK745007P1
(silicon rubber is filled up on the terminal block when con- • Wire rope (up to ø500mm) ZZP*TK464686C1
necting work) • Wire rope (up to ø1000mm) ZZP*TK464686C2
• Acoustic coupler: according to specified code of symbol. • Wire rope (up to ø1500mm) ZZP*TK464686C3
• Mass: 1.2kg • Wire rope (up to ø3000mm) ZZP*TK464686C6
• Wire rope (up to ø6000mm) ZZP*TK464686C13
Sillicon grease (GM40M) ZZP*45231N5
OUTLINE DIAGRAM (unit: mm) Sillicon rubber (KE348W) ZZP*45735N2
<Detector> Sillicon-free grease (HIGH-Z) ZZP*TK7M0981P1

Name plate
Scope of delivery
• Detector, acoustic coupler and set of the mounting belt
according to specified cord of symbol
84±1

• Signal cable conversion cord


114
<Signal cable conversion cord>
ø4.3 Cable BNC Connector
78±1
Wire rope
Sensor
8

Mounting spring
150
67±1

ø19

Large sensor: FSSE

14
CHECKED ITEMS BEFORE PURCHASE
Following conditions may cause failure of the measurement
or to reduce the accuracy.
Please consult and ask Fuji Electric for checking with actual
equipment previously if it is hard to judge the applicability.

1)Fluid
• I f fluid contains a large amount of bubbles (approx.
12vol% or more at 1m/s flow rate)
• If fluid has bad turbidity 10000(mg/L) or more,
• If fluid contains slurry or solid materials (about 5wt%)
• If flow rate is low Reynolds No.10000 or less,
(reference: flow rate 5m 3/h with ø100mm)
• If it is circulating oil, liquid medicine of low concentration,
waste liquid and hot spring,
2)Pipe
• If inside pipe is rusty carbon steel pipe,
• If inside pipe having adhering substances and sediment
• If outer surface of cast-iron pipe is rough,
• If pipe wall is tick such as ruinous pipe, (PP material
15mm or more, PVDF material 9mm or more)
• If it is SGPW pipe,
• If lining pipe is removed from pipe, (Teflon, PVC, Glass,
etc)
• If it is rubber pipe,
3) Pipe straight run
For accurate measurement, a certain length of pipe straight
run is required both upstream and downstream of the
measurement point. Be sure to satisfy the requirements
described on Page 8.

CAUTION ON USE
1) Do not damage the sensor or signal mounted on the pipe.
2) Make sure to fill the fluid inside the pipe to measure .
3) When you use horizontal pipe, it is recommended to install
the sensor horizontally.
4) When you use the grease as acoustic coupler to install
the sensor for outdoor use, it is recommended to install
the waterproof cover to prevent from the degradation.

15
FSC-4, FSS, FSD

Information in this catalog is subject to change without notice.


Read the instruction manuals thoroughly before using the products.

Gate City Ohsaki, East Tower, 11-2, Osaki 1-chome, Shinagawa-ku, Tokyo 141-0032, Japan
Phone: +81-3-5435-7111
www.fujielectric.com
www.fujielectric.com/products/instruments/

Printed in Japan

You might also like