MODEL VM-5Q REVERSE ROTATION MONITOR

VM-5 SERIES MONITOR

SPECIFICATIONS page 1 of 2

No entry if additional
Model Code / Additional Spec. Code( spec. code is not specified. )

VM-5Q- Note) The angle between the sensors shall be


as follows : Sensor for CH1
Forward
θs=(90+360n)/Z direction
Monitor range Monitor range θs
Input signal Recorder output
(forward speed) (reverse speed) [n=0,1,2,3•••Z:Numbers of the teeth]
1 to 1000rpm 1 to 1000rpm 1 VK,RD,FK Series *1 0 4 to 20mADC θs is recommended to be within 90 to
2 to 2000rpm 2 to 2000rpm 2 VE Series *2 1 1 to 5VDC 270°and to satisfy the above equation.
3 to 5000rpm 3 to 5000rpm VC Series *2 Output card Sensor for CH2
3 (Voltage output only)
4
5
to 10000rpm
to 15000rpm
4
5
to 10000rpm
to 15000rpm
2 /IS or /RE
option
-
6 to 20000rpm 6 to 20000rpm
Note) *1 VK transducer can not detect the
Speed reray type Speed reray type Speed reray type Speed reray type Hysteresis set value Hysteresis set value
wire break in the sensor system,
(forward speed) (forward speed) (reverse speed) (reverse speed) (shaped waveform circuit) (shaped waveform circuit)
so RD or FK driver which can
(SR1) (SR2) (SR3) (SR4) (CH1) (CH2)
detect the wire break shall be
recommended. 0 Over speed 0 Over speed 0 Over speed 0 Over speed 0 1.0V 0 1.0V
1 Under speed 1 Under speed 1 Under speed 1 Under speed 1 0.1V 1 0.1V
*2 Input abnormal alarm is not 2 0.2V 2 0.2V
applicable in case of VC and VE
input signal. - - 3 0.5V 3 0.5V

Alarm reset Alarm reset Alarm reset Alarm reset Alarm reset Alarm reset Relay mode Relay mode Relay mode Relay mode Relay mode Relay mode
(SR1) (SR2) (SR3) (SR4) (OK1) (OK2) (SR1) (SR2) (SR3) (SR4) (OK1) (OK1)
0 AUTO-RESET 0 AUTO-RESET 0 AUTO-RESET 0 AUTO-RESET 0 AUTO-RESET 0 AUTO-RESET NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY
0 0 0 0 0 0
1 SELF-HOLD 1 SELF-HOLD 1 SELF-HOLD 1 SELF-HOLD 1 SELF-HOLD 1 SELF-HOLD DE-ENERGIZED DE-ENERGIZED DE-ENERGIZED DE-ENERGIZED DE-ENERGIZED DE-ENERGIZED
NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY NORMALLY
1 1 1 1 1 1
Note) ENERGIZED ENERGIZED ENERGIZED ENERGIZED ENERGIZED ENERGIZED

Input abnormal detection - /(IS or RE )/5G /TRP


Input Abnormal sensor
Wire Short
signal setgap
break circuit
Small Large Monitor/pulse Recorder option Input power supply Tropical
RD Yes Yes Yes Yes First out*3 Trigger mode Isolate output
output output requirements spec.
VK No Yes Yes No 0 OFF 0 AUTO 0 Pulse output 0 4 to 20mADC 2 0 to -10VDC 0 85 to 264VAC
VE,VC No No No No 1 ON 1 MANUAL 1 Monitor output 1 1 to 5VDC 3 0 to 10VDC 1 24VDC
2 0 to -10VDC 4 0 to -5VDC 2 110VDC
! WARNING 3 0 to 10VDC 5 0 to 5VDC
4 0 to -5VDC Note) *3 It is necessary to set all
This monitor is designed for monitoring but not for controlling the rotor speed. monitor units in the same rack
• Use the speed relay contact only for alarms. 5 0 to 5VDC
in first out function ON when it
• Use the recorder output only for data recording. When recorder output code 2 is
selected, specify this option code. is used first out function.

Ordering Information Standard Specifications


INPUT If the indicated rotation speed is different from the input rotation SPEED RELAY SET ACCURACY 1 digit or less(on digital indicator)
SPEED/INDICATED speed, enter into the space below. SPEED RELAY OUTPUT Forward speed:2points(SR1,SR2), Reverse speed:2points(SR3,SR4)
SPEED CHANGED Input rotation speed rpm rpm ALARM OUTPUT 1point (OK) or 2points (OK1,OK2)
RATIO(NON-STANDARD From a magnification of more than 1, the resolution deteriorates in ROTOR SPEED LCD digital meter with 5 digits (7 segments, with back light)
SPECIFICATION) proportion to the magnification factor. LCD bar graph meter (40 segments, with back light)
SPEED RELAY SET SR1 : SPEED RELAY SR1,SR3 : (yellow LED)
VALUE SR2 : INDICATOR SR2,SR4 : (red LED)
SR3 : ABNOR. ALARM INDICATOR OK : (green LED)
SR4 : BYPASS INDICATOR BYPASS : (red LED)
SR2 ≥ SR1 SR4 ≥ SR3 TRANSDUCER INPUT VK,RD,FK Series, VE Series,VC Series
(SR2 ≤ SR1,SR4 ≤ SR3 in case of both under speed) Number of input points : 2points
Preset to 50% of monitor range unless specified otherwise. INPUT IMPEDANCE Approx. 5kΩ
SPEED RELAY MIN. PULSE WIDTH Approx. 50μsec
Speed relay hysteresis can be specified from 0 to 100rpm(1rpm step)
HYSTERESIS MIN. INDICATED FREQUENCY 0.01Hz
SR1 :
SR2 : NO. OF INPUT PULSE 1 to 60 pulse
SR3 : TRIGGER MODE AUTO, MANUAL (selectable)
SR4 : In case of auto trigger mode, input pulse duty ratio should be
between 10 and 90% and input pulse frequency should be 1Hz and
Preset to 10rpm unless specified otherwise.
over. it depends on the target.
NO. OF INPUT P/R Can be specified from 1 to 60 pulse. EXTERNAL CONTACT INPUT Contact type : Dry contact
Pulses/rev. : (FROM REAR PANEL) Contact for external reset
DIMENSION OF TARGET DIGITAL METER ±(0.003% of rdg. +1digit) at 25°C
(Model VK, RD,FK) D BA ±(0.03% of rdg. +1digit) at 0 to 65°C
C BAR GRAPH METER Recorder output conversion accuracy ±2.5% of F.S.
CAUTION) ・The surface of the part ”A” should be RECORDER OUTPUT ±0.5% of F.S. at 25°C
made to fit the concentric circuls curve of CONVERSION ACCURACY ±2.0% of F.S. at 0 to 65°C
the gear. RECORDER OUTPUT Voltage or current output proportional to monitor range
・“A=B“ must be standard. (FROM REAR PANEL) 1 to 5VDC (output impedance : 250Ω)
If “A≠B“ , 4 to 20mADC (max. oad resistance : 500Ω)
pay attention to *4 on next page. 0 to -10VDC*,0 to 10VDC*,0 to -5VDC*,0 to 5VDC*
VK-202A (output impedance : 100Ω) (*option)
VK-452A
Input RD-05A VK-302P Number of output points : 2 points(forward speed,reverse speed)
FK-452F
FK-202F MONITOR/PULSE Monitor output : Input signal is output via a buffer amplifier.
A= mm A ≥6 ≥16 ≥8 OUTPUT Signal level : -0.8 to -22VDC(VK,RD),0 to 15VDC(VE)
B= mm Dimension of target B ≥7 ≥20 ≥8
[recommended] (FROM FRONT, REAR 0 to 5VDC(VC)
C= mm
(mm) C ≥ 2.5 ≥ 4.5 ≥ 2.5 PANEL) Pulse output : Shaped pulse signal is output via a buffer
D= mm D ≥16 ≥36 ≥20
amplifier.
Set gap 1.0 to 1.5 2.5 to 3.5 1.0 to 1.5
[recommended](mm) Signal level : -1 to +1V(PL),4 to 6V(PH)
Output impedance : Approx. 100Ω (load resistance 50k or more)
TEMPERATURE RANGE Operating temperature : 0 to 65°C
Standard Specification Storage temperature : -30 to +85°C
SPEED RELAY SET POINT Forward speed:2points(SR1,SR2),Reverse speed:2points(SR3,SR4) Relative humidity : 20 to 95%RH(noncondensing)
SPEED RELAY SET More than 1rpm : Speed relay can be set in 1rpm increments until MATERIAL AND FINISH Face plate : Aluminum Munsell N-4.0(equiv.)
RANGE 110% of monitor range MASS Monitor :max.0.7kg
Less than 1rpm : Speed relay can be set in 0.1rpm increment (including single unit instrument rack max.2.5kg)

6H14-209 Rev.3
Issued: Feb. 2015
Revised: Jul. 2017
MODEL VM-5Q REVERSE ROTATION MONITOR
VM-5 SERIES MONITOR

SPECIFICATIONS page 2 of 2

Number of teeth and angle θs (Reference)

(In the case of “A=B”)


Number of Angle θs Setting
accuracy
teeth (deg) (deg)
1 90.0 ――― ――― ――― ――― ――― ――― ――― ±30.0
2 225.0 ――― ――― ――― ――― ――― ――― ――― ±15.0
3 150.0 270.0 ――― ――― ――― ――― ――― ――― ±10.0
4 112.5 202.5 ――― ――― ――― ――― ――― ――― ± 7.5
5 90.0 162.0 234.0 ――― ――― ――― ――― ――― ± 6.0
6 135.0 195.0 255.0 ――― ――― ――― ――― ――― ± 5.0
7 115.7 167.1 218.6 270.0 ――― ――― ――― ――― ± 4.3
8 101.3 146.3 191.3 236.3 ――― ――― ――― ――― ± 3.8
9 90.0 130.0 170.0 210.0 250.0 ――― ――― ――― ± 3.3
10 117.0 153.0 189.0 225.0 261.0 ――― ――― ――― ± 3.0
11 106.4 139.1 171.8 204.5 237.3 270.0 ――― ――― ± 2.7
12 97.5 127.5 157.5 187.5 217.5 247.5 ――― ――― ± 2.5
13 90.0 117.7 145.4 173.1 200.8 228.5 256.2 ――― ± 2.3
14 109.3 135.0 160.7 186.4 212.1 237.9 263.6 ――― ± 2.1
15 102.0 126.0 150.0 174.0 198.0 222.0 246.0 270.0 ± 2.0
16 95.6 118.1 140.6 163.1 185.6 208.1 230.6 253.1 ± 1.9
94.5 112.5 130.5 148.5 166.5 184.5 202.5 220.5
20 ± 1.5
238.5 256.5 ――― ――― ――― ――― ――― ―――
99.0 111.0 123.0 135.0 147.0 159.0 171.0 183.0
30 ± 1.0
195.0 207.0 219.0 231.0 243.0 255.0 267.0
92.5 102.5 112.5 122.5 132.5 142.5 152.5 162.5
36 ± 0.8
172.5 +10.0 step 262.5
92.3 101.3 110.3 119.3 128.3 137.3 146.3 155.3
40 ± 0.8
164.3 +9.0 step 263.3
91.5 97.5 103.5 109.5 115.5 121.5 127.5 133.5
60 ± 0.5
139.5 +6.0 step 265.5

Note) *1 The above angle θs is selected to satisfy θs=(90+360n)/Z and to be within 90 ≤ θs ≤ 270.
・Conditions
Equal to the cicular thickness and the space width.
(Refer to the size of the detection tooth type on the previous page.)
*2 The setting accuracy of the angle θs shall be ±30.0/Z.
*3 The above *1,*2 shall be calculated, in the case of the number of teeth except the above table.
*4 In order to detect rotating direction, waveform pulse must overlap. Especially, in the case of A≠B, it must
be paid attention. In the case that teeth of gear is few or the gear shape is unusual, θs, in this chart, is not
applied.
Modify the position and angle of two sensors in order to overlap waveform pulse.

D B A

Shaped pulse output of both channels Shaped pulse output of both channels
(Can be judgment of the rotation direction.) (Can not be judgment of the rotation direction.) Dimension of target

6H14-209 Rev.3
Issued: Feb. 2015
Revised: Jul. 2017