0% found this document useful (0 votes)
89 views16 pages

BoQ For All Three LLRP Davis 2017

The document outlines a detailed quotation for a solar pumping system, including components such as a submersible pump, solar controller, solar modules, power cables, and various accessories. The total cost for the project is 4,800,197.51, which includes VAT and various installation and maintenance services. Each part is itemized with quantities, unit prices, and remarks regarding specifications and compatibility.

Uploaded by

sayyohabba2021
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
89 views16 pages

BoQ For All Three LLRP Davis 2017

The document outlines a detailed quotation for a solar pumping system, including components such as a submersible pump, solar controller, solar modules, power cables, and various accessories. The total cost for the project is 4,800,197.51, which includes VAT and various installation and maintenance services. Each part is itemized with quantities, unit prices, and remarks regarding specifications and compatibility.

Uploaded by

sayyohabba2021
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd

NO.

ITEM DESCRIPTION QTY UNIT Unit price Total Price Remark


PART A: Main components

Submersible centrifugal pump to supply 152.64m3/day at 120.24m We have offered 9.2kw SUBMERSIBLE
head directly coupled to 9.2kW submersible PUMP C/W 9.2
1 AC motor (380/400V 3-phase) 1 set 1,010,946.00 1,010,946.00 KW motor

2 Solar controller as DC-AC inverter for the above pump 1 pc 342,406.00 342,406.00 We have offered 11KW Solar
controller

3 550 Watt mono crystalline solar modules 33 pc 33,000.00 1,089,000.00


PART B: Power supply cables
16 mm2 4-cores PVC SUBMERSIBLE 99% copper submersible power
cable- Round cable from borehole to pump controller to changeover
4 switch 130 M 2,133.00 277,290.00 We have offered 3*16mm2 cable

PART C: DC accessories and earth protection

PV Disconnection switch or combiner box appropriate for the


number of modules and maximum voltage and
5 1 pc 49,873.00 49,873.00
current of the PV array

6 10mm twin flat DC cable


2
66 M 282.00 18,612.00 1*6mm2 cable DC cable

7 PV surge protector 1 pc 50,000.00 50,000.00


8 Lightning arrestor with copper strips of not less than 1 pc We have offered lighting arrestor with
25mmx4mm 35m 16mm2 earthing cable and 2 PCS
of eathing rod
37,547.00 37,547.00
9 5/8 100% copper earth rod. 1 pc

10 10mm2 Copper earth cable 20 M


11 Cable splicing kit 1 Pc 10,288.00 10,288.00
PART D: Sensors

12 Well sensor kit for dry run protection and which must be 1 pc 12,812.00 12,812.00
compatible with the supplied controller

3 vulcanized electrodes 1.5 mm2 2-core PVC round hardened


13 submersible WELL SENSOR cables waterproof 130 M 258.00 33,540.00 2*1.5mm2 sensor cable

PART E: Pipes and piping accessories

14 6-meter length 6" borehole steel pipe complete with 19 pc 18,200.00 345,800.00
steel sockets

Well head cover for 10" steel casing c/w well head accessories
including valve, test tee, pressure
15 gauge connection, union etc. 1 set - -

PART F: Controls and Accessories for hybrid operation

16 Supply and install 40A Change over switch 1 pc 48,600.00 48,600.00

PART G: Module support structure

Allow for civil works of reinforced concrete and foundation bolts, the
whole foundation must be raised to a level such that steel column
17 won’t be in contact with storm water 1 LS

Supply and erect a panel support structure made of 4'' Pipe Class A Panel Support steel Structure made of
poles, drilled plates 160*160*8mm, 50x50x3mm rafters, 2.5" GI Pipe, with 40*40*3mm Angle
50x50x3mm SHS struts and ties, 40x40x4mm angle iron, 150 tilt and 327,409.76 327,409.76
Iron [Link] height of
lower end to be minimum 1.2m above ground level to support the structure 1.5m
quantity of panels above. All joints to be bolt and nuts with spot
18 1 LS
welding

19 Inverter and DC breaker locker made of metal frame with proper 1 LS 24,538.00 24,538.00
ventilation openings

Supply and installation of diesel generator set, continuous rating, as


per the technical specification, engine & alternator pre-installed on a
common rigid frame, switchgear panel, day tank incorporated into the
frame, exhaust piping system, including manufacturer working,
service &maintenance manual, spare part catalogue and all
accessories required for Supply prime power part catalogue are very
necessary. 23kVA, 3phase, 380V, 50Hz, 1500RPM. Remark:-
accessories are pairs of (fuel filter, oil filter and air cleaner) operation 1 set - -
and maintenace manual, spare part catalogue are very necessary

PART H: Installation
Construction of woven wire mesh fence circumference around the
solar pumping system. The fencing work consist of preparing and
fixing of 3m high 40x40x3mm Angle iron spaced at 2m interval
around the circumference and a length of 500mm Angle Iron buried
below ground level and anchored with mass concrete of [Link] mix
ratio, and length of Angle Iron above 2m fom ground level should be
bent 45 degree to the inner side of the fence and should be fixed with
barbed wire at 15cm interval the entire circumference of the fence.
The fence should be 2m away from the solar panels in all four sides
and the hole should have minimum dimension of Fence around the structure -
40mmx400mmx500mm depth and base of the fence should be Made of angle iron pole
20 reinforced with mass concrete of [Link] mixed ratio having a 1 LS 245,428.57 245,428.57 40*40*3, 2.5" GI corner pole ,
dimension of 0.3mx0.4m around the entire circumference of the Gabion and mesh wire- 2 meter
fence. Price shall include excavation, cart away, supplying away from each array
construction materials (gravel, sand, cement), fixing formwork, tying
wire, cutting angle iron, bending, erecting and bracing.

21 Transport and installation of all the equipment and materials to 1 LS 722,490.46 722,490.46
Amomalita site, 14km from Awra Woreda centre

PART I: Others
23 Cable clamp per 3-meter length for total power cable 1 set 516.00 516.00
length

Metallic Enclosure for housing the controls, well ventilated and SMALL METAL BOX FOR ENCLOSURE
24 lockable 1 pc 17,038.00 17,038.00 OF CHANGE OVER
SWITCH

25 Equipment & tool set to be used by scheme operator (digital 1 set - -


multimeter-rating 1000V, solar meter, set of screw drivers, cable
cutter, pliers, hummer, set of allen-
keys, pipe wrench, insulating tape-10pcs etc)

Alarm system set with siren for intrusion and safety protection of
solar modules, where intrusion detection is based on mechanical
vibrations/ tampering of the solar array structure, wired and
26 integrated within the 1 LS - -
installation; complete with all accessories

Design and production (printed in full colour and bound) of


27 maintenance charts, record keeping books and facility 1 pc - -
data plate - well laminated
28 2 years’ service maintenance contract after expiry of 1 1 pc - -
year DLP
SUB TOTAL 4,174,084.79
ADD VAT 626,112.72
TOTAL 4,800,197.51
Reference Comments

Specifications based on the duty point

Size based on the power requirement of the


pump motor

Quantity based on the rating and design

Sized appropriately for pump power. AC cable that runs


from the pump to the well head

Type and number required will depend on the number


of strings

Sized appropriately for the DC current of of


the PV generator

For lightning strikes protection

For earthing

For dry run protection

Runs from the sensor inside the borehole to the well


head to the inverter

Can be plastic or steel, installed inside the


borehole

Size should match the borehole casing size. Ensure that


pump selected will fit into the
borehole

Separates DC and AC power to the pump. Can also be


provided as an automatic or power
blending solution

Designed taking into account self weight, panel weight


and also wind forces.
Construction should be done with correctly sized
members, adequate cross braces, adequate foundation
(especially for elevated structures), be made of
corrosion resistant steel, raised foundation that is
resistant to erosion during flooding etc.
Required if there is no pump house to mount the
controls

Include items as required

A security measure to prevent theft

Recommended in the first 1-2 years of system


installation
NO. ITEM DESCRIPTION QTY UNIT Unit price Total Price Remark

PART A: Main components

Submersible centrifugal pump to supply 457.92m3/day at 120.24m We have offered 9.2kw SUBMERSIBLE
head directly coupled to 9.2kW submersible PUMP C/W 9.2
1 AC motor (380/400V 3-phase) 1 set 1,010,946.00 1,010,946.00 KW motor

2 Solar controller as DC-AC inverter for the above pump 1 pc 342,406.00 342,406.00 We have offered 11KW Solar
controller

3 550 Watt mono crystalline solar modules 33 pc 18,150.00 598,950.00

PART B: Power supply cables

16 mm2 4-cores PVC SUBMERSIBLE 99% copper submersible power


cable- Round cable from borehole to pump controller to changeover
4 switch 130 M 2,133.00 277,290.00 We have offered 3*16mm2 cable

PART C: DC accessories and earth protection

PV Disconnection switch or combiner box appropriate for the


number of modules and maximum voltage and
5 current of the PV array 1 pc 49,873.00 49,873.00

6 10mm2 twin flat DC cable 66 M 282.00 18,612.00 1*6mm2 cable DC cable

7 PV surge protector 1 pc 50,000.00 50,000.00

8 Lightning arrestor with copper strips of not less than 1 pc We have offered lighting arrestor with
25mmx4mm 35m 16mm2 earthing cable and 2 PCS of
eathing rod
9 5/8 100% copper earth rod. 1 pc 37,547.00 37,547.00

10 10mm2 Copper earth cable 20 M

11 Cable splicing kit 1 Pc 10,288.00 10,288.00

PART D: Sensors

12 Well sensor kit for dry run protection and which must be 1 pc 12,812.00 12,812.00
compatible with the supplied controller

3 vulcanized electrodes 1.5 mm2 2-core PVC round hardened


submersible WELL SENSOR cables waterproof
13 130 M 258.00 33,540.00 2*1.5mm2 sensor cable

PART E: Pipes and piping accessories

14 6-meter length 6" borehole steel pipe complete with 19 pc 18,200.00 345,800.00
steel sockets

Well head cover for 10" steel casing c/w well head accessories
including valve, test tee, pressure
15 gauge connection, union etc. 1 set - -

PART F: Controls and Accessories for hybrid operation

16 Supply and install 40A Change over switch 1 pc 48,600.00 48,600.00

PART G: Module support structure

Allow for civil works of reinforced concrete and foundation bolts, the
whole foundation must be raised to a level such that steel column
17 won’t be in contact with storm water 1 LS

Supply and erect a panel support structure made of 4'' Pipe Class A Panel Support steel Structure made of
poles, drilled plates 160*160*8mm, 50x50x3mm rafters, 2.5" GI Pipe, with 40*40*3mm Angle
50x50x3mm SHS struts and ties, 40x40x4mm angle iron, 150 tilt and 327,409.76 327,409.76 Iron [Link] height of structure
lower end to be minimum 1.2m above ground level to support the 1.5m
quantity of panels above. All joints to be bolt and nuts with spot
18 welding 1 LS

19 Inverter and DC breaker locker made of metal frame with proper 1 LS 24,538.00 24,538.00
ventilation openings

Supply and installation of diesel generator set, continuous rating, as


per the technical specification, engine & alternator pre-installed on a
common rigid frame, switchgear panel, day tank incorporated into the
frame, exhaust piping system, including manufacturer working,
service &maintenance manual, spare part catalogue and all
accessories required for Supply prime power 1 set - -
part catalogue are very necessary.

PART H: Installation
Construction of woven wire mesh fence circumference around the
solar pumping system. The fencing work consist of preparing and
fixing of 3m high 40x40x3mm Angle iron spaced at 2m interval
around the circumference and a length of 500mm Angle Iron buried
below ground level and anchored with mass concrete of [Link] mix
ratio, and length of Angle Iron above 2m fom ground level should be
bent 45 degree to the inner side of the fence and should be fixed with
barbed wire at 15cm interval the entire circumference of the fence.
The fence should be 2m away from the solar panels in all four sides
and the hole should have minimum dimension of
40mmx400mmx500mm depth and base of the fence should be
reinforced with mass concrete of [Link] mixed ratio having a Fence around the structure - Made
dimension of 0.3mx0.4m around the entire circumference of the of angle iron pole 40*40*3, 2.5"
20 fence. Price shall include excavation, cart away, supplying 1 LS 245,428.57 245,428.57 GI corner pole , Gabion and mesh
construction materials (gravel, sand, cement), fixing formwork, tying wire- 2 meter away from each array
wire, cutting angle iron, bending, erecting and bracing.

21 Transport and installation of all the equipment and materials to 1 LS 722,490.46 722,490.46
Amomalita site, 14km from Awra Woreda centre

PART I: Others

23 Cable clamp per 3-meter length for total power cable 1 set 516.00 516.00
length

Metallic Enclosure for housing the controls, well ventilated and SMALL METAL BOX FOR ENCLOSURE OF
lockable CHANGE OVER
24 1 pc 17,038.00 17,038.00 SWITCH

25 Equipment & tool set to be used by scheme operator (digital 1 set - -


multimeter-rating 1000V, solar meter, set of screw drivers, cable
cutter, pliers, hummer, set of allen-
keys, pipe wrench, insulating tape-10pcs etc)

Alarm system set with siren for intrusion and safety protection of
solar modules, where intrusion detection is based on mechanical
vibrations/ tampering of the solar array structure, wired and
26 integrated within the 1 LS - -
installation; complete with all accessories

Design and production (printed in full colour and bound) of


maintenance charts, record keeping books and facility
27 data plate - well laminated 1 pc - -

28 2 years’ service maintenance contract after expiry of 1 1 pc - -


year DLP

SUB TOTAL 4,174,084.79

ADD VAT 626,112.72

TOTAL 4,800,197.51
Reference Comments

Specifications based on the duty point

Size based on the power requirement of the


pump motor

Quantity based on the rating and design

Sized appropriately for pump power. AC cable that runs


from the pump to the well head

Type and number required will depend on the number


of strings

Sized appropriately for the DC current of of


the PV generator

For lightning strikes protection

For earthing

For dry run protection

Runs from the sensor inside the borehole to the well


head to the inverter

Can be plastic or steel, installed inside the


borehole

Size should match the borehole casing size. Ensure that


pump selected will fit into the
borehole

Separates DC and AC power to the pump. Can also be


provided as an automatic or power
blending solution

Designed taking into account self weight, panel weight


and also wind forces.
Construction should be done with correctly sized
members, adequate cross braces, adequate foundation
(especially for elevated structures), be made of
corrosion resistant steel, raised foundation that is
resistant to erosion during flooding etc.
Required if there is no pump house to mount the
controls

Include items as required

A security measure to prevent theft

Recommended in the first 1-2 years of system


installation
NO. ITEM DESCRIPTION QTY UNIT Unit price Total Price Remark

PART A: Main components

Submersible centrifugal pump to supply 457.92m3/day at 120.24m We have offered 9.2kw SUBMERSIBLE
head directly coupled to 9.2kW submersible PUMP C/W 9.2
1 AC motor (380/400V 3-phase) 1 set 1,010,946.00 1,010,946.00 KW motor

2 Solar controller as DC-AC inverter for the above pump 1 pc 342,406.00 342,406.00 We have offered 11KW Solar
controller

3 550 Watt mono crystalline solar modules 33 pc 18,150.00 598,950.00

PART B: Power supply cables

16 mm2 4-cores PVC SUBMERSIBLE 99% copper submersible power


cable- Round cable from borehole to pump controller to changeover
4 switch 130 M 2,133.00 277,290.00 We have offered 3*16mm2 cable

PART C: DC accessories and earth protection

PV Disconnection switch or combiner box appropriate for the


number of modules and maximum voltage and
5 current of the PV array 1 pc 49,873.00 49,873.00

6 10mm2 twin flat DC cable 66 M 282.00 18,612.00 1*6mm2 cable DC cable

7 PV surge protector 1 pc 50,000.00 50,000.00

8 Lightning arrestor with copper strips of not less than 1 pc We have offered lighting arrestor with
25mmx4mm 35m 16mm2 earthing cable and 2 PCS of
eathing rod
9 5/8 100% copper earth rod. 1 pc 37,547.00 37,547.00

10 10mm2 Copper earth cable 20 M

11 Cable splicing kit 1 Pc 10,288.00 10,288.00

PART D: Sensors

12 Well sensor kit for dry run protection and which must be 1 pc 12,812.00 12,812.00
compatible with the supplied controller

3 vulcanized electrodes 1.5 mm2 2-core PVC round hardened


submersible WELL SENSOR cables waterproof
13 130 M 258.00 33,540.00 2*1.5mm2 sensor cable

PART E: Pipes and piping accessories

14 6-meter length 6" borehole steel pipe complete with 19 pc 18,200.00 345,800.00
steel sockets

Well head cover for 10" steel casing c/w well head accessories
including valve, test tee, pressure
15 gauge connection, union etc. 1 set - -

PART F: Controls and Accessories for hybrid operation

16 Supply and install 40A Change over switch 1 pc 48,600.00 48,600.00

PART G: Module support structure

Allow for civil works of reinforced concrete and foundation bolts, the
whole foundation must be raised to a level such that steel column
17 won’t be in contact with storm water 1 LS

Supply and erect a panel support structure made of 4'' Pipe Class A Panel Support steel Structure made of
poles, drilled plates 160*160*8mm, 50x50x3mm rafters, 2.5" GI Pipe, with 40*40*3mm Angle
50x50x3mm SHS struts and ties, 40x40x4mm angle iron, 150 tilt and 327,409.76 327,409.76 Iron [Link] height of structure
lower end to be minimum 1.2m above ground level to support the 1.5m
quantity of panels above. All joints to be bolt and nuts with spot
18 welding 1 LS

19 Inverter and DC breaker locker made of metal frame with proper 1 LS 24,538.00 24,538.00
ventilation openings

Supply and installation of diesel generator set, continuous rating, as


per the technical specification, engine & alternator pre-installed on a
common rigid frame, switchgear panel, day tank incorporated into the
frame, exhaust piping system, including manufacturer working,
service &maintenance manual, spare part catalogue and all
accessories required for Supply prime power 1 set - -
part catalogue are very necessary.

PART H: Installation
Construction of woven wire mesh fence circumference around the
solar pumping system. The fencing work consist of preparing and
fixing of 3m high 40x40x3mm Angle iron spaced at 2m interval
around the circumference and a length of 500mm Angle Iron buried
below ground level and anchored with mass concrete of [Link] mix
ratio, and length of Angle Iron above 2m fom ground level should be
bent 45 degree to the inner side of the fence and should be fixed with
barbed wire at 15cm interval the entire circumference of the fence.
The fence should be 2m away from the solar panels in all four sides
and the hole should have minimum dimension of
40mmx400mmx500mm depth and base of the fence should be
reinforced with mass concrete of [Link] mixed ratio having a Fence around the structure - Made
dimension of 0.3mx0.4m around the entire circumference of the of angle iron pole 40*40*3, 2.5"
20 fence. Price shall include excavation, cart away, supplying 1 LS 245,428.57 245,428.57 GI corner pole , Gabion and mesh
construction materials (gravel, sand, cement), fixing formwork, tying wire- 2 meter away from each array
wire, cutting angle iron, bending, erecting and bracing.

21 Transport and installation of all the equipment and materials to 1 LS 722,490.46 722,490.46
Amomalita site, 14km from Awra Woreda centre

PART I: Others

23 Cable clamp per 3-meter length for total power cable 1 set 516.00 516.00
length

Metallic Enclosure for housing the controls, well ventilated and SMALL METAL BOX FOR ENCLOSURE OF
lockable CHANGE OVER
24 1 pc 17,038.00 17,038.00 SWITCH

25 Equipment & tool set to be used by scheme operator (digital 1 set - -


multimeter-rating 1000V, solar meter, set of screw drivers, cable
cutter, pliers, hummer, set of allen-
keys, pipe wrench, insulating tape-10pcs etc)

Alarm system set with siren for intrusion and safety protection of
solar modules, where intrusion detection is based on mechanical
vibrations/ tampering of the solar array structure, wired and
26 integrated within the 1 LS - -
installation; complete with all accessories

Design and production (printed in full colour and bound) of


maintenance charts, record keeping books and facility
27 data plate - well laminated 1 pc - -

28 2 years’ service maintenance contract after expiry of 1 1 pc - -


year DLP

SUB TOTAL 4,174,084.79

ADD VAT 626,112.72

TOTAL 4,800,197.51
Reference Comments

Specifications based on the duty point

Size based on the power requirement of the


pump motor

Quantity based on the rating and design

Sized appropriately for pump power. AC cable that runs


from the pump to the well head

Type and number required will depend on the number


of strings

Sized appropriately for the DC current of of


the PV generator

For lightning strikes protection

For earthing

For dry run protection

Runs from the sensor inside the borehole to the well


head to the inverter

Can be plastic or steel, installed inside the


borehole

Size should match the borehole casing size. Ensure that


pump selected will fit into the
borehole

Separates DC and AC power to the pump. Can also be


provided as an automatic or power
blending solution

Designed taking into account self weight, panel weight


and also wind forces.
Construction should be done with correctly sized
members, adequate cross braces, adequate foundation
(especially for elevated structures), be made of
corrosion resistant steel, raised foundation that is
resistant to erosion during flooding etc.
Required if there is no pump house to mount the
controls

Include items as required

A security measure to prevent theft

Recommended in the first 1-2 years of system


installation
NO. ITEM DESCRIPTION QTY UNIT Unit price Total Price Remark

PART A: Main components

Submersible centrifugal pump to supply 457.92m3/day at 120.24m We have offered 9.2kw SUBMERSIBLE
head directly coupled to 9.2kW submersible PUMP C/W 9.2
1 AC motor (380/400V 3-phase) 1 set 1,010,946.00 1,010,946.00 KW motor

2 Solar controller as DC-AC inverter for the above pump 1 pc 342,406.00 342,406.00 We have offered 11KW Solar
controller

3 550 Watt mono crystalline solar modules 33 pc 18,150.00 598,950.00

PART B: Power supply cables

16 mm2 4-cores PVC SUBMERSIBLE 99% copper submersible power


cable- Round cable from borehole to pump controller to changeover
4 switch 130 M 2,133.00 277,290.00 We have offered 3*16mm2 cable

PART C: DC accessories and earth protection

PV Disconnection switch or combiner box appropriate for the


number of modules and maximum voltage and
5 current of the PV array 1 pc 49,873.00 49,873.00

6 10mm2 twin flat DC cable 66 M 282.00 18,612.00 1*6mm2 cable DC cable

7 PV surge protector 1 pc 50,000.00 50,000.00

8 Lightning arrestor with copper strips of not less than 1 pc We have offered lighting arrestor with
25mmx4mm 35m 16mm2 earthing cable and 2 PCS of
eathing rod
9 5/8 100% copper earth rod. 1 pc 37,547.00 37,547.00

10 10mm2 Copper earth cable 20 M

11 Cable splicing kit 1 Pc 10,288.00 10,288.00

PART D: Sensors

12 Well sensor kit for dry run protection and which must be 1 pc 12,812.00 12,812.00
compatible with the supplied controller

3 vulcanized electrodes 1.5 mm2 2-core PVC round hardened


submersible WELL SENSOR cables waterproof
13 130 M 258.00 33,540.00 2*1.5mm2 sensor cable

PART E: Pipes and piping accessories

14 6-meter length 6" borehole steel pipe complete with 19 pc 18,200.00 345,800.00
steel sockets

Well head cover for 10" steel casing c/w well head accessories
including valve, test tee, pressure
15 gauge connection, union etc. 1 set - -

PART F: Controls and Accessories for hybrid operation

16 Supply and install 40A Change over switch 1 pc 48,600.00 48,600.00

PART G: Module support structure

Allow for civil works of reinforced concrete and foundation bolts, the
whole foundation must be raised to a level such that steel column
17 won’t be in contact with storm water 1 LS

Supply and erect a panel support structure made of 4'' Pipe Class A Panel Support steel Structure made of
poles, drilled plates 160*160*8mm, 50x50x3mm rafters, 2.5" GI Pipe, with 40*40*3mm Angle
50x50x3mm SHS struts and ties, 40x40x4mm angle iron, 150 tilt and 327,409.76 327,409.76 Iron [Link] height of structure
lower end to be minimum 1.2m above ground level to support the 1.5m
quantity of panels above. All joints to be bolt and nuts with spot
18 welding 1 LS

19 Inverter and DC breaker locker made of metal frame with proper 1 LS 24,538.00 24,538.00
ventilation openings

Supply and installation of diesel generator set, continuous rating, as


per the technical specification, engine & alternator pre-installed on a
common rigid frame, switchgear panel, day tank incorporated into the
frame, exhaust piping system, including manufacturer working,
service &maintenance manual, spare part catalogue and all
accessories required for Supply prime power 1 set - -
part catalogue are very necessary.

PART H: Installation
Construction of woven wire mesh fence circumference around the
solar pumping system. The fencing work consist of preparing and
fixing of 3m high 40x40x3mm Angle iron spaced at 2m interval
around the circumference and a length of 500mm Angle Iron buried
below ground level and anchored with mass concrete of [Link] mix
ratio, and length of Angle Iron above 2m fom ground level should be
bent 45 degree to the inner side of the fence and should be fixed with
barbed wire at 15cm interval the entire circumference of the fence.
The fence should be 2m away from the solar panels in all four sides
and the hole should have minimum dimension of
40mmx400mmx500mm depth and base of the fence should be
reinforced with mass concrete of [Link] mixed ratio having a Fence around the structure - Made
dimension of 0.3mx0.4m around the entire circumference of the of angle iron pole 40*40*3, 2.5"
20 fence. Price shall include excavation, cart away, supplying 1 LS 245,428.57 245,428.57 GI corner pole , Gabion and mesh
construction materials (gravel, sand, cement), fixing formwork, tying wire- 2 meter away from each array
wire, cutting angle iron, bending, erecting and bracing.

21 Transport and installation of all the equipment and materials to 1 LS 722,490.46 722,490.46
Amomalita site, 14km from Awra Woreda centre

PART I: Others

23 Cable clamp per 3-meter length for total power cable 1 set 516.00 516.00
length

Metallic Enclosure for housing the controls, well ventilated and SMALL METAL BOX FOR ENCLOSURE OF
lockable CHANGE OVER
24 1 pc 17,038.00 17,038.00 SWITCH

25 Equipment & tool set to be used by scheme operator (digital 1 set - -


multimeter-rating 1000V, solar meter, set of screw drivers, cable
cutter, pliers, hummer, set of allen-
keys, pipe wrench, insulating tape-10pcs etc)

Alarm system set with siren for intrusion and safety protection of
solar modules, where intrusion detection is based on mechanical
vibrations/ tampering of the solar array structure, wired and
26 integrated within the 1 LS - -
installation; complete with all accessories

Design and production (printed in full colour and bound) of


maintenance charts, record keeping books and facility
27 data plate - well laminated 1 pc - -

28 2 years’ service maintenance contract after expiry of 1 1 pc - -


year DLP

SUB TOTAL 4,174,084.79

ADD VAT 626,112.72

TOTAL 4,800,197.51
Reference Comments

Specifications based on the duty point

Size based on the power requirement of the


pump motor

Quantity based on the rating and design

Sized appropriately for pump power. AC cable that runs


from the pump to the well head

Type and number required will depend on the number


of strings

Sized appropriately for the DC current of of


the PV generator

For lightning strikes protection

For earthing

For dry run protection

Runs from the sensor inside the borehole to the well


head to the inverter

Can be plastic or steel, installed inside the


borehole

Size should match the borehole casing size. Ensure that


pump selected will fit into the
borehole

Separates DC and AC power to the pump. Can also be


provided as an automatic or power
blending solution

Designed taking into account self weight, panel weight


and also wind forces.
Construction should be done with correctly sized
members, adequate cross braces, adequate foundation
(especially for elevated structures), be made of
corrosion resistant steel, raised foundation that is
resistant to erosion during flooding etc.
Required if there is no pump house to mount the
controls

Include items as required

A security measure to prevent theft

Recommended in the first 1-2 years of system


installation

You might also like