0% found this document useful (0 votes)
59 views3 pages

Daikin VRVIII-S System Overview

The VRVIII-S system offers a wide range of indoor and outdoor units, with 71 models in 14 types, designed for small offices and shops, ensuring easy installation. It features high energy efficiency and quiet operation, utilizing advanced technologies such as a unique scroll compressor and Reluctance DC motor. Additionally, the system provides design flexibility with long refrigerant piping lengths and the capability to connect up to 9 indoor units to a single outdoor unit.

Uploaded by

Durga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views3 pages

Daikin VRVIII-S System Overview

The VRVIII-S system offers a wide range of indoor and outdoor units, with 71 models in 14 types, designed for small offices and shops, ensuring easy installation. It features high energy efficiency and quiet operation, utilizing advanced technologies such as a unique scroll compressor and Reluctance DC motor. Additionally, the system provides design flexibility with long refrigerant piping lengths and the capability to connect up to 9 indoor units to a single outdoor unit.

Uploaded by

Durga
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

MAIN FEATURES

Wide range of choices


To suit the variety of rooms found in small offices
Indoor units
and shops, the VRVIII-S system offers wide range of 14 types 71 models*
indoor and outdoor units. A wide range of indoor units includes
VRVIII-S indoor and outdoor units are almost as easy 71 models in 14 types. The indoor
to install as residential air conditioning systems, units can be selected to match every
making them ideal for small offices and shops. room and preference.

Outdoor units
3 models
Outdoor unit can be selected from three
models to provide the power that suits
your needs. The trunk-shaped outdoor unit
can be neatly installed outside the office.
Indoor unit lineup 14 types 71 models*
Outdoor unit lineup Type Model Name 20 25 32 40 50 63 80 100 125 140
Model Name RX(Y)MQ4PVE RX(Y)MQ5PVE RX(Y)MQ6PVE Capacity Range 0.8 HP 1 HP 1.25 HP 1.6 HP 2 HP 2.5 HP 3.2 HP 4 HP 5 HP 6 HP
Capacity Index 20 25 31.25 40 50 62.5 80 100 125 140
Capacity Range 4 HP (11.2 kW) 5 HP (14.0 kW) 6 HP (15.5 kW) Ceiling Mounted FXFQ-LU
Cassette
(Round Flow)
Capacity Index 100 125 140 Ceiling Mounted FXZQ-MVE
Cassette
(Compact Multi Flow)
Ceiling Mounted FXCQ-MVE
Cassette
(Double Flow)
Ceiling Mounted FXKQ-MAVE
Cassette Corner

FXDQ-PBVE
(with drain pump)

Slim Ceiling
Mounted Duct FXDQ-NBVE
(with drain pump)

Ceiling Mounted FXMQ-PVE


Duct

Ceiling Suspended FXHQ-MAVE

Wall Mounted FXAQ-PVE


New New New New New New New

Floor Standing FXLQ-MAVE

Concealed FXNQ-MAVE
Floor Standing

Note: R-410A VRV system indoor units are not compatible with the R-22 VRV system.

Connection unit series indoor units (50 Hz only)


Type Model Name Capacity Range 0.8 HP 1 HP 1.25 HP 1.6 HP 2 HP 3 HP 4 HP 5 HP
Capacity Index 20 25 31.25 40 50 71 100 125
Connection Unit — BEVQ71MAVE BEVQ100MAVE BEVQ125MAVE
Ceiling Suspended FXUQ-MAV1
Cassette

Note: BEV units are necessary for Connection unit series indoor units.

3 4
MAIN FEATURES
Energy efficiency and quiet operation A collection of cutting-edge technologies
Outdoor units use Daikin’s unique scroll compressor to realise energy saving
realises efficient and quiet operation.
performance and quiet operation. The high efficiency compressor to achieve a higher COP
1 Compressor equipped with Reluctance DC motor 3
High COP
Daikin DC inverter models are equipped with the Reluctance DC
High COP during both cooling and achieved
in all ranges! motor for compressor. The Reluctance DC motor uses 2 different 2

heating operations VRVII-S


Previous model
types of torque, neodymium magnet*1 and reluctance torque*2. This
motor can save energy because it generates more power with a
RXYM-MVM
smaller electric power than an AC or conventional DC motor.
One of the top features of the VRVIII-S is Cooling 4 HP 3.65
Reluctance DC motor 1
its energy efficiency. It achieves high COP 5 HP 3.28 90

Motor efficiency (%)


during cooling and heating operations by 6 HP 2.92 80
employing Daikin’s unique scroll Heating 4 HP 3.68 Conventional DC motor

compressor. 5 HP 3.41
70 More than 20% RX(Y)MQ4PVE
RX(Y)MQ5PVE
RX(Y)MQ6PVE
6 HP 3.19 60 AC motor

Above values are based on the following nominal conditions: Reluctance


50 DC motor
• 2 Ceiling Mounted Cassette (Round Flow) type units are connected (4 HP: 0 30 60 90 120
FXFQ50P x 2; 5 HP: FXFQ63P x 2; and 6 HP: FXFQ63P + FXFQ80P.) Rotational speed (rps)
• Cooling: Indoor temp. of 27CDB, 19CWB, and outdoor temp. of 35CDB.
• Heating: Indoor temp. of 20CDB, and outdoor temp. of 7CDB, 6CWB. Small load Large load
Low capacity High capacity

Quiet operation provides Note: Data are based on studies conducted under

luxurious comfort Lower operation sound is achieved controlled conditions at a Daikin laboratory
using Daikin products.
in cooling operation! 1 dB(A) reduced
*1 A neodymium magnet is approximately 10 times
Quietness is yet another important feature in each model! stronger than a standard ferrite magnet.
VRVII-S *2 The torque created by the change in power
of Daikin’s VRVIII-S system. To reduce Previous model
RXYM-MVM between the iron and magnet parts.
noise and realise comfortable operation,
latest technologies and features are Cooling 4 HP 51 -1dB(A) 50
>> Smooth sine wave DC inverter
applied to the outdoor units. 52
Sine wave DC inverter
5 HP -1dB(A) 51 Use of an optimised sine wave smoothes motor rotation, further improving
operating efficiency.

Nighttime quiet operation function


Operation sound level selectable 2 Smooth Air Inlet Bell Mouth and Aero Spiral Fan
With the bent Without the bent
from 3 steps for the night mode Mode 1. Automatic mode
These two features work to reduce sound. blade edge blade edge
Mode 1. Automatic mode
Guides are added to the bell mouth intake to
Set on the outdoor PCB. Time of maximum
temperature is memorised. The low operating mode
reduce turbulence in the airflow generated by
100
will become active 8 hours*1 after the peak fan suction. The Aero Spiral Fan features fan
temperature in the daytime, and operation will return to blades with the bent blade edges, further
normal 10 hours*2 after that. The operation sound
level for the night mode can be selected from 47 dB(A) 50
(Initial setting) (Initial setting) reducing turbulence. Escaping eddies are sucked in by
(Step 1), 44 dB(A) (Step 2) and 41 dB(A) (Step 3). the bent blade edges, reducing
overall turbulence.

Mode 2. Manual mode 0


50
Night Mode 3 DC fan motor DC motor efficiency
Starting time and ending time can be input. (An external
control adaptor for outdoor unit, DTA104A61 or
Step 1 max. - 3 dB(A)
( 4 HP/11.2 kW)
Step 1: 47 dB(A) Efficiency improved in all areas compared (comparison with AC motor)
100
DTA104A62, and a locally obtained timer are 47
Step 2 max. - 6 dB(A)
to conventional AC motors, especially at
necessary.) ( 4 HP/11.2 kW) Step 2: 44 dB(A)
low speeds. 80
44 DC motor

Efficiency (%)
Step 3 max. - 9 dB(A) Approx.
Step 3: 41 dB(A)
Mode 3. Combined mode ( 4 HP/11.2 kW) DC fan motor structure 60 20%
41 increase
Combinations of modes 1 and 2 can be used starts ends 40
Approx.
depending on your needs. 8:00 12:00 16:00 20:00 0:00 4:00 8:00 40% AC motor
Note: Data are based on
*1. Initial setting. Can be selected from 6, 8 and 10 hours. Note: • This function is available in setting at site. 20 increase
studies conducted under
*2. Initial setting. Can be selected from 8, 9 and 10 hours. • The relationship of outdoor temperature (load) and time shown in the
0 controlled conditions at
graph is just an example.
200 300 400 500 600 700 800 900 1000 a Daikin laboratory.
The capacity reduction rate differs depending on the operation sound level
Motor speed (rpm)
step selected.
5 6
MAIN FEATURES
Design flexibility Easy installation
VRVIII-S systems offer broad design flexibility with long refrigerant piping lengths and A variety of functions are provided that make installation easier, such as simple wiring
multiple indoor unit combinations, which provides generous freedom for office and shop and piping and automatic test operation.
design both inside and out. Previous model
VRVII-S

As many as 9 indoor units can be Easy wiring


connected to a single outdoor unit A printed circuit board has been
adopted that is easy to see and wire
Multiple indoor unit combinations are possible.* As many as 9 indoor units can be connected
during installation.
to a single outdoor unit, making the VRVIII-S a remarkably versatile system.
* Total capacity index of connectable indoor units must be 50 - 130 % of the capacity index of the outdoor unit.

For a 6 HP installation
Automatic test operation
Simply press the test operation button and the unit performs an automatic system check,
1 2 3 4
Max. including wiring, shutoff valves, and sensors. The results are returned automatically after the
9 units
check finishes.
>> Max. 8 indoor units for a 5 HP
installation
5 6 7 8 9
>> Max. 6 indoor units for a 4 HP
installation
Simple wiring and piping connection
Unique piping and wiring systems make it possible to install a VRVIII-S system quickly and easily.

Long piping design possible >> Super wiring system


A super wiring system is used to enable shared use of the
The VRVIII-S provides the long piping wiring between indoor and outdoor units and the central
length possibility of 150 m, with a total piping *2 control wiring, with a relatively simple wiring operation.
length of 300 m. If the outdoor unit is Max. 50 m*1 The DIII-NET communication system is employed to
Level enable the use of advanced control systems.
installed above indoor units the level difference
difference can be up to a maximum of 50 m. Max. 15 m
These generous allowances facilitate an Level difference
between indoor Outdoor unit
extensive variety of system designs. units
Central
Actual piping length Total piping length remote
Max. 150 m Max. 300 m Notes: *1. 40 m when the outdoor unit is installed below indoor units. controller
Indoor unit
*2. Maximum piping length between the indoor unit and the first branch is 40 m.

>> REFNET piping system


Daikin’s advanced REFNET piping system makes
installation easy. Only two main refrigerant lines are
Wide operation temperature range Certified operation temperature range
required in any one system. REFNET greatly reduces the
50 46CDB
imbalances in refrigerant flow between units, while using
small-diameter piping.
40
Outdoor temperature (CWB)
Outdoor temperature (CDB)

The versatile operation range of the VRVIII-S system 30 20 15.5CWB


works to reduce limitations on installation locations. The 10
20
operation temperature range for heating goes all the way
0
down to -20C, while cooling can be performed with 10
outdoor temperatures as high as 46C. Both these 0 -10
achievements are due to the adoption of a high-pressure -5CDB -20
-10 –20CWB
dome-type compressor.
Cooling Heating

7 8

You might also like