Page 1 of 14
Print Calculation Sheet
Isolated Footing Design (IS 456-2000)
Footing No. Group ID Foundation Geometry
- - Length Width Thickness
1 1 2.00m 2.00m 0.30m
Footing No. Footing Reinforcement Pedestal Reinforcement
- Bottom Reinforcement(Mz) Bottom Reinforcement(Mx) Top Reinforcement(Mz) Top Reinforcement(Mx) Main Steel Trans Steel
1 Ø10 @ 210 mm c/c Ø10 @ 210 mm c/c N/A N/A N/A
Isolated Footing 1
0.5 m
0.3 m
Elevation
X 1m
0.23 m
0.3 m
2m
1m
2m
Plan
Input Values
Footing Geometry
Calculate Dimension with user
Design Type : specified minimums as
starting value
Minimum Footing Length - X(Fl) : 2000.00 mm
Minimum Footing Width - Z (Fw) : 2000.00 mm
Minimum Footing Thickness(Ft) : 300.00 mm
Eccentricity along X (Oxd) : 0.00 mm
Eccentricity along Z (Ozd) : 0.00 mm
Column Dimensions
Column Shape : Rectangular
Column Length - X (Pl) : 0.23 m
[Link] 11/18/2024
Page 2 of 14
Column Width - Z (Pw) : 0.30 m
Pedestal
Include Pedestal : No
Pedestal Shape : N/A
Design Parameters
Concrete and Rebar Properties
Unit Weight of Concrete : 24.00 kN/m3
Strength of Concrete : 20.00 N/mm2
Yield Strength of Steel : 500.00 N/mm2
Minimum Bar Size : Ø10
Maximum Bar Size : Ø20
Pedestal Minimum Bar Size : Ø8
Pedestal Maximum Bar Size : Ø40
Minimum Bar Spacing : 100.00 mm
Maximum Bar Spacing : 450.00 mm
Pedestal Clear Cover (P, CL) : 50.00 mm
Footing Clear Cover (F, CL) : 50.00 mm
Soil Properties
Unit Weight : 17.60 kN/m3
Base Value of Soil Bearing Capacity : 100.00 kN/m2
Multiplying factor for soil bearing
: 1.70
capacity for ultimate loads
Soil Bearing Capacity Type : Gross Bearing Capacity
Soil Surcharge : 0.00 kN/m2
Height of Soil above Footing : 500.00 mm
Type of Depth : Fixed Top
Minimum Percentage of Slab area in
: 0.00
Contact for Service Loads
Minimum Percentage of Slab area in
: 0.00
Contact for Ultimate Loads
Sliding and Overturning
Coefficient of Friction : 0.50
Factor of Safety Against Sliding : 1.50
Factor of Safety Against Overturning : 1.50
Global Settings
Top Reinforcement Option : Calculate only when foundation is subjected to uplift forces
Concrete Design Option : Net Pressure(Gross Pressure - Self Weight Pressure)
------------------------------------------------------
Design Calculations
Load Combinations
Load Combination/s- Service Stress Level
Load Case Soil Self
Load Combination
Load Combination Title Multiplier Bearing Weight Code
Number
(a) Factor (b) Factor (c)
a - Value specified in the Load Multiplier table
b - Value specified in the Pile/Soil Bearing Capacity Factors table
c - Value specified in the Apply Self Weight and Dead Weight Factor table
[Link] 11/18/2024
Page 3 of 14
Load Combination/s- Service Stress Level
Load Case Soil Self
Load Combination
Load Combination Title Multiplier Bearing Weight Code
Number
(a) Factor (b) Factor (c)
a - Value specified in the Load Multiplier table
b - Value specified in the Pile/Soil Bearing Capacity Factors table
c - Value specified in the Apply Self Weight and Dead Weight Factor table
1 DL 1.00 1.00 1.00 -
2 LL 1.00 1.00 1.00 -
3 RLL 1.00 1.00 1.00 -
4 COMB - 1.5 Dead + 1.5 Live 1.00 1.00 1.00 -
5 COMB - 1.2 Dead + 1.2 Live 1.00 1.00 1.00 -
6 COMB - 1.5 Dead 1.00 1.00 1.00 -
7 COMB - 0.9 Dead 1.00 1.00 1.00 -
1001 SL:1.000 x DL 1.00 1.00 1.00 Indian
1002 SL:1.000 x DL+1.000 x LL 1.00 1.00 1.00 Indian
1003 SL:1.000 x DL 1.00 1.00 1.00 Indian
1004 SL:1.000 x DL 1.00 1.00 1.00 Indian
1005 SL:1.000 x DL 1.00 1.00 1.00 Indian
1006 SL:1.000 x DL 1.00 1.00 1.00 Indian
1007 SL:1.000 x DL 1.00 1.00 1.00 Indian
1008 SL:1.000 x DL 1.00 1.00 1.00 Indian
1009 SL:1.000 x DL 1.00 1.00 1.00 Indian
1010 SL:1.000 x DL 1.00 1.00 1.00 Indian
1011 SL:1.000 x DL+0.800 x LL 1.00 1.00 1.00 Indian
1012 SL:1.000 x DL+0.800 x LL 1.00 1.00 1.00 Indian
1013 SL:1.000 x DL+0.800 x LL 1.00 1.00 1.00 Indian
1014 SL:1.000 x DL+0.800 x LL 1.00 1.00 1.00 Indian
1015 SL:1.000 x DL+0.800 x LL 1.00 1.00 1.00 Indian
1016 SL:1.000 x DL+0.800 x LL 1.00 1.00 1.00 Indian
1017 SL:1.000 x DL+0.800 x LL 1.00 1.00 1.00 Indian
1018 SL:1.000 x DL+0.800 x LL 1.00 1.00 1.00 Indian
1019 SL:0.900 x DL 1.00 1.00 0.90 Indian
1020 SL:0.900 x DL 1.00 1.00 0.90 Indian
1021 SL:0.900 x DL 1.00 1.00 0.90 Indian
1022 SL:0.900 x DL 1.00 1.00 0.90 Indian
1023 SL:0.900 x DL 1.00 1.00 0.90 Indian
1024 SL:0.900 x DL 1.00 1.00 0.90 Indian
1025 SL:0.900 x DL 1.00 1.00 0.90 Indian
1026 SL:0.900 x DL 1.00 1.00 0.90 Indian
Load Combination/s- Strength Level
Load Case Soil Self
Load Combination
Load Combination Title Multiplier Bearing Weight Code
Number
(a) Factor (b) Factor (c)
a - Value specified in the Load Multiplier table
b - Value specified in the Pile/Soil Bearing Capacity Factors table
c - Value specified in the Apply Self Weight and Dead Weight Factor table
1 DL 1.00 1.00 1.00 -
2 LL 1.00 1.00 1.00 -
3 RLL 1.00 1.00 1.00 -
4 COMB - 1.5 Dead + 1.5 Live 1.00 1.00 1.00 -
5 COMB - 1.2 Dead + 1.2 Live 1.00 1.00 1.00 -
6 COMB - 1.5 Dead 1.00 1.00 1.00 -
7 COMB - 0.9 Dead 1.00 1.00 1.00 -
2001 UL:1.500 x DL 1.00 1.00 1.50 Indian
2002 UL:1.500 x DL+1.500 x LL 1.00 1.00 1.50 Indian
2003 UL:1.500 x DL 1.00 1.00 1.50 Indian
2004 UL:1.500 x DL 1.00 1.00 1.50 Indian
2005 UL:1.500 x DL 1.00 1.00 1.50 Indian
2006 UL:1.500 x DL 1.00 1.00 1.50 Indian
2007 UL:1.500 x DL 1.00 1.00 1.50 Indian
2008 UL:1.500 x DL 1.00 1.00 1.50 Indian
2009 UL:1.500 x DL 1.00 1.00 1.50 Indian
2010 UL:1.500 x DL 1.00 1.00 1.50 Indian
2011 UL:1.200 x DL+1.200 x LL 1.00 1.00 1.20 Indian
2012 UL:1.200 x DL+1.200 x LL 1.00 1.00 1.20 Indian
2013 UL:1.200 x DL+1.200 x LL 1.00 1.00 1.20 Indian
2014 UL:1.200 x DL+1.200 x LL 1.00 1.00 1.20 Indian
[Link] 11/18/2024
Page 4 of 14
Load Combination/s- Strength Level
Load Case Soil Self
Load Combination
Load Combination Title Multiplier Bearing Weight Code
Number
(a) Factor (b) Factor (c)
a - Value specified in the Load Multiplier table
b - Value specified in the Pile/Soil Bearing Capacity Factors table
c - Value specified in the Apply Self Weight and Dead Weight Factor table
2015 UL:1.200 x DL+1.200 x LL 1.00 1.00 1.20 Indian
2016 UL:1.200 x DL+1.200 x LL 1.00 1.00 1.20 Indian
2017 UL:1.200 x DL+1.200 x LL 1.00 1.00 1.20 Indian
2018 UL:1.200 x DL+1.200 x LL 1.00 1.00 1.20 Indian
2019 UL:0.900 x DL 1.00 1.00 0.90 Indian
2020 UL:0.900 x DL 1.00 1.00 0.90 Indian
2021 UL:0.900 x DL 1.00 1.00 0.90 Indian
2022 UL:0.900 x DL 1.00 1.00 0.90 Indian
2023 UL:0.900 x DL 1.00 1.00 0.90 Indian
2024 UL:0.900 x DL 1.00 1.00 0.90 Indian
2025 UL:0.900 x DL 1.00 1.00 0.90 Indian
2026 UL:0.900 x DL 1.00 1.00 0.90 Indian
Applied Loads on Top of Pedestal
Before consideration of self weight and load multiplier table
Moments are About the center of Column / Pedestal (does not include moments caused by lateral loads)
For the loads shown in this table, the sign convention is the same as that for JOINT LOADS in [Link] when global Y is the vertical axis.
Applied Loads for Column - Service Stress Level
Fy
(kN)
Fx Fz Mx Mz
Load Case Downwards is
(kN) (kN) (kNm) (kNm)
negative Upwards
is positive
1 -0.61 -116.12 -1.31 -1.35 0.91
2 -0.06 -7.93 -0.15 -0.17 0.16
3 -0.01 -1.80 -0.02 -0.02 0.01
4 -1.01 -186.07 -2.19 -2.29 1.60
5 -0.80 -148.85 -1.75 -1.83 1.28
6 -0.91 -174.18 -1.96 -2.03 1.36
7 -0.55 -104.51 -1.18 -1.22 0.82
1001 -0.61 -116.12 -1.31 -1.35 0.91
1002 -0.67 -124.04 -1.46 -1.53 1.07
1003 -0.61 -116.12 -1.31 -1.35 0.91
1004 -0.61 -116.12 -1.31 -1.35 0.91
1005 -0.61 -116.12 -1.31 -1.35 0.91
1006 -0.61 -116.12 -1.31 -1.35 0.91
1007 -0.61 -116.12 -1.31 -1.35 0.91
1008 -0.61 -116.12 -1.31 -1.35 0.91
1009 -0.61 -116.12 -1.31 -1.35 0.91
1010 -0.61 -116.12 -1.31 -1.35 0.91
1011 -0.66 -122.46 -1.43 -1.49 1.04
1012 -0.66 -122.46 -1.43 -1.49 1.04
1013 -0.66 -122.46 -1.43 -1.49 1.04
1014 -0.66 -122.46 -1.43 -1.49 1.04
1015 -0.66 -122.46 -1.43 -1.49 1.04
1016 -0.66 -122.46 -1.43 -1.49 1.04
1017 -0.66 -122.46 -1.43 -1.49 1.04
1018 -0.66 -122.46 -1.43 -1.49 1.04
1019 -0.55 -104.51 -1.18 -1.22 0.82
1020 -0.55 -104.51 -1.18 -1.22 0.82
1021 -0.55 -104.51 -1.18 -1.22 0.82
1022 -0.55 -104.51 -1.18 -1.22 0.82
1023 -0.55 -104.51 -1.18 -1.22 0.82
1024 -0.55 -104.51 -1.18 -1.22 0.82
1025 -0.55 -104.51 -1.18 -1.22 0.82
1026 -0.55 -104.51 -1.18 -1.22 0.82
Applied Loads for Column - Strength Level
Fy
(kN)
Fx Fz Mx Mz
Load Case Downwards is
(kN) (kN) (kNm) (kNm)
negative Upwards
is positive
1 -0.61 -116.12 -1.31 -1.35 0.91
2 -0.06 -7.93 -0.15 -0.17 0.16
3 -0.01 -1.80 -0.02 -0.02 0.01
4 -1.01 -186.07 -2.19 -2.29 1.60
5 -0.80 -148.85 -1.75 -1.83 1.28
[Link] 11/18/2024
Page 5 of 14
Applied Loads for Column - Strength Level
Fy
(kN)
Fx Fz Mx Mz
Load Case Downwards is
(kN) (kN) (kNm) (kNm)
negative Upwards
is positive
6 -0.91 -174.18 -1.96 -2.03 1.36
7 -0.55 -104.51 -1.18 -1.22 0.82
2001 -0.91 -174.18 -1.96 -2.03 1.36
2002 -1.01 -186.07 -2.19 -2.29 1.60
2003 -0.91 -174.18 -1.96 -2.03 1.36
2004 -0.91 -174.18 -1.96 -2.03 1.36
2005 -0.91 -174.18 -1.96 -2.03 1.36
2006 -0.91 -174.18 -1.96 -2.03 1.36
2007 -0.91 -174.18 -1.96 -2.03 1.36
2008 -0.91 -174.18 -1.96 -2.03 1.36
2009 -0.91 -174.18 -1.96 -2.03 1.36
2010 -0.91 -174.18 -1.96 -2.03 1.36
2011 -0.80 -148.85 -1.75 -1.83 1.28
2012 -0.80 -148.85 -1.75 -1.83 1.28
2013 -0.80 -148.85 -1.75 -1.83 1.28
2014 -0.80 -148.85 -1.75 -1.83 1.28
2015 -0.80 -148.85 -1.75 -1.83 1.28
2016 -0.80 -148.85 -1.75 -1.83 1.28
2017 -0.80 -148.85 -1.75 -1.83 1.28
2018 -0.80 -148.85 -1.75 -1.83 1.28
2019 -0.55 -104.51 -1.18 -1.22 0.82
2020 -0.55 -104.51 -1.18 -1.22 0.82
2021 -0.55 -104.51 -1.18 -1.22 0.82
2022 -0.55 -104.51 -1.18 -1.22 0.82
2023 -0.55 -104.51 -1.18 -1.22 0.82
2024 -0.55 -104.51 -1.18 -1.22 0.82
2025 -0.55 -104.51 -1.18 -1.22 0.82
2026 -0.55 -104.51 -1.18 -1.22 0.82
------------------------------------------------------
Footing Size
Initial Length (Lo) = 2.00 m
Initial Width (Wo) = 2.00 m
2
Area from initial length and width, Ao = = 4.00 m
2
Min. area required from bearing pressure, Amin = = 2.49 m
Note: Amin is an initial estimation.
P = Vertical load from column + selfweight of footing + weight of soil.
qmax = Respective Factored Bearing Capacity.
Final Footing Size
Length (L2) = 2.00 m Governing Load Case : # 2002
Width (W2) = 2.00 m Governing Load Case : # 2002
Depth (D2) = 0.30 m
2
Area (A2) = 4.00 m
Depth is governed by Ultimate Load Case
(Service check is performed with footing thickness requirements from concrete check)
Final Soil Height = 0.50 m
Weight of the footing + pedestal (if any) = 28.80 kN
Weight of the soil above the footing (dry) = 34.59 kN
Uplift force due to buoyancy = 0.00 kN
Effect due to adhesion = 0.00 kN
[Link] 11/18/2024
Page 6 of 14
------------------------------------------------------
Gross Pressures at 4 Corners
Pressure at Pressure at Pressure at Pressure at Area of Gross
top left top right bottom bottom left footing in Bearing
Load Case
corner corner right corner corner uplift (Au) Capacity
2
(kN/m2) (kN/m2) (kN/m2) (kN/m2) (m ) (kN/m2)
4 65.9986 63.1442 58.7281 61.5824 0.00 100.0000
4 65.9986 63.1442 58.7281 61.5824 0.00 100.0000
4 65.9986 63.1442 58.7281 61.5824 0.00 100.0000
4 65.9986 63.1442 58.7281 61.5824 0.00 100.0000
If Au is zero, there is no uplift and no pressure adjustment is necessary. Otherwise, to account for uplift, areas of negative pressure will be set to zero and the
pressure will be redistributed to remaining corners.
Summary of adjusted Gross Pressures at Four Corners
Pressure at Pressure at Pressure at Pressure at
Gross Bearing
top left top right bottom right bottom left
Load Case Capacity
corner corner corner corner
(kN/m2)
(kN/m2) (kN/m2) (kN/m2) (kN/m2)
4 65.9986 63.1442 58.7281 61.5824 100.0000
4 65.9986 63.1442 58.7281 61.5824 100.0000
4 65.9986 63.1442 58.7281 61.5824 100.0000
4 65.9986 63.1442 58.7281 61.5824 100.0000
Details of Out-of-Contact Area
(If Any)
Governing load case = N/A
Plan area of footing = 4.00 sq.m
Area not in contact with soil = = 0.00 sq.m
% of total area not in contact = 0.00%
------------------------------------------------------
Stability Check
OTM
0.5 m
.
Sliding Force
Frictional Force 0.3 m
[Link] 11/18/2024
Page 7 of 14
Factor of safety against
- Factor of safety against sliding
overturning
Load
Along X- Along Z- Required About X- About Z- Required
Case Resultant
Direction Direction FOS Direction Direction FOS
No.
1 147.79 68.59 62.22 1.50 102.90 164.39 1.50
2 567.94 238.57 219.95 1.50 326.71 403.70 1.50
3 N/A N/A N/A 1.50 N/A N/A 1.50
4 124.09 57.03 51.82 1.50 84.73 131.09 1.50
5 131.97 60.66 55.11 1.50 90.11 139.42 1.50
6 130.39 60.52 54.90 1.50 90.79 145.04 1.50
7 153.59 71.28 64.66 1.50 106.94 170.84 1.50
1001 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1002 139.86 64.28 58.41 1.50 95.49 147.75 1.50
1003 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1004 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1005 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1006 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1007 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1008 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1009 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1010 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1011 141.32 65.07 59.11 1.50 96.84 150.69 1.50
1012 141.32 65.07 59.11 1.50 96.84 150.69 1.50
1013 141.32 65.07 59.11 1.50 96.84 150.69 1.50
1014 141.32 65.07 59.11 1.50 96.84 150.69 1.50
1015 141.32 65.07 59.11 1.50 96.84 150.69 1.50
1016 141.32 65.07 59.11 1.50 96.84 150.69 1.50
1017 141.32 65.07 59.11 1.50 96.84 150.69 1.50
1018 141.32 65.07 59.11 1.50 96.84 150.69 1.50
1019 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1020 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1021 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1022 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1023 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1024 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1025 147.79 68.59 62.22 1.50 102.90 164.39 1.50
1026 147.79 68.59 62.22 1.50 102.90 164.39 1.50
Critical Load Case And The Governing Factor Of Safety For Overturning and Sliding X Direction
Critical Load Case for Sliding along X-Direction : 4
Governing Disturbing Force : -1.01 kN
Governing Restoring Force : 124.73 kN
Minimum Sliding Ratio for the Critical Load Case : 124.09
Critical Load Case for Overturning About X-Direction : 4
Governing Overturning Moment : -2.94 kNm
Governing Resisting Moment : 249.45 kNm
Minimum Overturning Ratio for the Critical Load Case : 84.73
Critical Load Case And The Governing Factor Of Safety For Overturning and Sliding Z Direction
Critical Load Case for Sliding along Z-Direction : 4
Governing Disturbing Force : -2.19 kN
Governing Restoring Force : 124.73 kN
Minimum Sliding Ratio for the Critical Load Case : 57.03
Critical Load Case for Overturning About Z-Direction : 4
[Link] 11/18/2024
Page 8 of 14
Governing Overturning Moment : 1.90 kNm
Governing Resisting Moment : : 249.45 kNm
Minimum Overturning Ratio for the Critical Load Case : 131.09
Critical Load Case And The Governing Factor Of Safety For Sliding Along Resultant Direction
Critical Load Case for Sliding along Resultant Direction : : 4
Governing Disturbing Force : 2.41 kN
Governing Restoring Force : 124.73 kN
Minimum Sliding Ratio for the Critical Load Case : 51.82
------------------------------------------------------
Top Reinforcement Design Requirement
Top Reinforcement needs to be provided because of resultant negative pressure coming from net pressure calculations
for bending.
Ultimate Gross Pressures
The base pressures reported in this table and the area of footing in contact include the effect of buoyancy (if any).
Gross
Factored Area of
Pressure at
Load Case / Pressure at Pressure at Pressure at Bearing footing in
bottom
Load top left top right bottom left Capacity Contact
right
Combination corner corner corner For with soil
corner
ID (kN/m2) (kN/m2) (kN/m2) Ultimate (Au)
(kN/m2) 2
Load Case (m )
(kN/m2)
1 47.0035 45.3656 42.7489 44.3868 170.0000 4.00
2 18.1245 17.8596 17.5321 17.7971 170.0000 4.00
3 16.3179 16.3068 16.2757 16.2868 170.0000 4.00
4 65.9986 63.1442 58.7281 61.5824 170.0000 4.00
5 55.9682 53.6847 50.1518 52.4353 170.0000 4.00
6 62.5819 60.1250 56.1999 58.6568 170.0000 4.00
7 43.8878 42.4137 40.0586 41.5328 170.0000 4.00
2001 70.5052 68.0483 64.1233 66.5802 170.0000 4.00
2002 73.9219 71.0676 66.6514 69.5058 170.0000 4.00
2003 70.5052 68.0483 64.1233 66.5802 170.0000 4.00
2004 70.5052 68.0483 64.1233 66.5802 170.0000 4.00
2005 70.5052 68.0483 64.1233 66.5802 170.0000 4.00
2006 70.5052 68.0483 64.1233 66.5802 170.0000 4.00
2007 70.5052 68.0483 64.1233 66.5802 170.0000 4.00
2008 70.5052 68.0483 64.1233 66.5802 170.0000 4.00
2009 70.5052 68.0483 64.1233 66.5802 170.0000 4.00
2010 70.5052 68.0483 64.1233 66.5802 170.0000 4.00
2011 59.1376 56.8541 53.3211 55.6046 170.0000 4.00
2012 59.1376 56.8541 53.3211 55.6046 170.0000 4.00
2013 59.1376 56.8541 53.3211 55.6046 170.0000 4.00
2014 59.1376 56.8541 53.3211 55.6046 170.0000 4.00
2015 59.1376 56.8541 53.3211 55.6046 170.0000 4.00
2016 59.1376 56.8541 53.3211 55.6046 170.0000 4.00
2017 59.1376 56.8541 53.3211 55.6046 170.0000 4.00
2018 59.1376 56.8541 53.3211 55.6046 170.0000 4.00
2019 42.3031 40.8290 38.4740 39.9481 170.0000 4.00
2020 42.3031 40.8290 38.4740 39.9481 170.0000 4.00
2021 42.3031 40.8290 38.4740 39.9481 170.0000 4.00
2022 42.3031 40.8290 38.4740 39.9481 170.0000 4.00
2023 42.3031 40.8290 38.4740 39.9481 170.0000 4.00
[Link] 11/18/2024
Page 9 of 14
2024 42.3031 40.8290 38.4740 39.9481 170.0000 4.00
2025 42.3031 40.8290 38.4740 39.9481 170.0000 4.00
2026 42.3031 40.8290 38.4740 39.9481 170.0000 4.00
Minimum Required Contact Area for Ultimate Loads : 0.00 m2
Actual Area in Contact for all ultimate load cases exceeds the minimum required. Hence Safe
Maximum Corner Pressure from all ultimate load cases is less than the allowable. Hence Safe
Moment Calculation
Check Trial Depth against moment (About Z Axis)
Critical Load Case = #4
Effective Depth = = 0.24 m
Governing moment (Mu) = = 37.27 kNm
As Per IS 456 2000 ANNEX G G-1.1C
Limiting Factor1 (Kumax) = = 0.46
Limiting Factor2 (Rumax) = = 2654.52 kN/m2
Limiting Moment Of Resistance
= = 293.19 kNm
(Mumax)
Mu <= Mumax hence, safe
Check Trial Depth against moment (About X Axis)
Critical Load Case = #4
Effective Depth = = 0.24 m
Governing moment (Mu) = = 34.55 kNm
As Per IS 456 2000 ANNEX G G-1.1C
Limiting Factor1 (Kumax) = = 0.46
Limiting Factor2 (Rumax) = = 2654.52 kN/m2
Limiting Moment Of Resistance
= = 293.19 kNm
(Mumax)
Mu <= Mumax hence, safe
------------------------------------------------------
One-Way Shear in XY plane
(Shear Plane Parallel to Global X Axis)
X 1m
Z 0.61 m
1m
0.61 m
Plan
[Link] 11/18/2024
Page 10 of 14
Critical Load Case = # 4
Distance of critical section from top left corner along Z,
= 0.61 m
DZ
Shear Force(S) = 58.54 kN
Shear Stress(Tv) = 124.55 kN/m2
Percentage Of Steel(Pt) = 0.1671
As Per IS 456 2000 Clause 40 Table 19
Shear Strength Of Concrete(Tc) = 301.57 kN/m2
Shear Enhancement Factor (if considered) is applied to (Tc), as per IS456 -2000 Clause No 40.5.1 and Fig 24
Tv< Tc hence, safe
One-Way Shear in YZ plane
(Shear Plane Parallel to Global Z Axis)
X 1m
0.645 m 0.645 m
1m
Plan
Critical Load Case = #4
Distance of critical section from top left corner along X,
= 0.65 m
DX
Shear Force(S) = 61.70 kN
Shear Stress(Tv) = 131.28 kN/m2
Percentage Of Steel(Pt) = 0.17
As Per IS 456 2000 Clause 40 Table 19
Shear Strength Of Concrete(Tc) = 301.57 kN/m2
Shear Enhancement Factor (if considered) is applied to (Tc), as per IS456 -2000 Clause No 40.5.1 and Fig 24
Tv< Tc hence, safe
Punching Shear Check
[Link] 11/18/2024
Page 11 of 14
X 1m
Z
0.12 m
1m
Plan
Critical Load Case = #2002
Shear Force(S) = 185.48 kN
Shear Stress(Tv) = 381.30 kN/m2
As Per IS 456 2000 Clause [Link]
Ks = = 1.00
Shear Strength(Tc) = = 1118.03 kN/m2
Ks x T c = 1118.03 kN/m2
Tv<= Ks x Tc hence, safe
------------------------------------------------------
Reinforcement Calculation
Calculation of Maximum Bar Size
Along X Axis
Bar diameter corresponding to max bar size (db) = 12 mm
As Per IS 456 2000 Clause 26.2.1
Development Length(ld) = = 0.65 m
Available Development Length(ldb) = = 0.84 m
ldb >=ld hence, safe
Along Z Axis
Bar diameter corresponding to max bar size(db) = 12 mm
As Per IS 456 2000 Clause 26.2.1
Development Length(ld) = = 0.65 m
Available Development Length(ldb) = = 0.80 m
ldb >=ld hence, safe
Flexure About X-Axis
Design For Bottom Reinforcement Parallel to Z Axis
[Link] 11/18/2024
Page 12 of 14
10 - 10 mm
For moment About X Axis (Mx)
As Per IS 456 2000 Clause [Link]
Critical Load Case = #4
Minimum Area of Steel (Astmin) = 720 mm2
Calculated Area of Steel (Ast) = 720 mm2
Note - "Area of Steel required" reported here is the larger
value between the calculated area of steel and minimum
steel required as per code stipulations
Provided Area of Steel (Ast,Provided) = 785 mm2
Ast,Provided >= Astmin Hence OK.
Selected bar Size (db) = Ø10
Minimum spacing allowed (Smin) = 100.00 mm
Selected spacing (S) = 210.00 mm
Smin<= S <= Smax and selected bar size < selected maximum bar size. Hence OK.
Based on spacing reinforcement increment; provided reinforcement is
Ø10 @ 210mm o.c.
Flexure About Z-Axis
Design For Bottom Reinforcement Parallel to X Axis
10 - 10 mm
[Link] 11/18/2024
Page 13 of 14
For moment About Z Axis (Mz)
As Per IS 456 2000 Clause [Link]
Critical Load Case = #4
Minimum Area of Steel (Astmin) = 720 mm2
Calculated Area of Steel (Ast) = 720 mm2
Note - "Area of Steel required" reported here is the larger
value between the calculated area of steel and minimum
steel required as per code stipulations
Provided Area of Steel (Ast,Provided) = 785 mm2
Ast,Provided >= Astmin Hence OK.
Selected bar Size (db) = Ø10
Minimum spacing allowed (Smin) = 100.00 mm
Selected spacing (S) = 210.00 mm
Smin<= S <= Smax and selected bar size < selected maximum bar size. Hence OK.
Based on spacing reinforcement increment; provided reinforcement is
Ø10 @ 210mm o.c.
Crack Width Calculation (for Mz)
Modulus of Elasticity of Concrete(Ec) = 22360679.77 kN/m2 Clause No. [Link]
Modulus of Elasticity of Steel(Es) = 200000000.00 kN/m2 Annexure F
Annexure G, Clause No. G-
Depth of Neutral Axis(Xu) = 0.11 m
1.1.a
Effective MOI(Ieff) = 1052998793.57 mm4
Average Steel Strain at Considered Level(Ɛm) = 0.00 X 10
-5
Distance from Nearest Tension Rod (acr) = 0.12 m
Crack Width (Wcr) = 0.00 mm Annexure F
From IS 456-2000 Clause No. 35.3.2
Section is uncracked.
Crack Width Calculation (for Mx)
Modulus of Elasticity of Concrete(Ec) = 22360679.77 kN/m2 Clause No. [Link]
Modulus of Elasticity of Steel(Es) = 200000000.00 kN/m2 Annexure F
Annexure G, Clause No. G-
Depth of Neutral Axis(Xu) = 0.11 m
1.1.a
Effective MOI(Ieff) = 1052998793.57 mm4
Average Steel Strain at Considered Level(Ɛm) = 0.00 X 10-5
Distance from Nearest Tension Rod (acr) = 0.12 m
Crack Width (Wcr) = 0.00 mm Annexure F
From IS 456-2000 Clause No. 35.3.2
Section is uncracked.
------------------------------------------------------
[Link] 11/18/2024
Page 14 of 14
[Link] 11/18/2024
X 1m
Z
0.23 m
0.3 m
2m
0.5 m
1m
2m
0.3 m
Plan
1m
Elevation
BOTTOM 10 - 10 mm
Dimensions (m) Reinforcement
TOP N/A
L B D AstX(T) AstZ(T) AstX(B) AstZ(B)
Foundation
1m
2m 2m 0.3 m N/A N/A 10 - 10 mm 10 - 10 mm
l b h Main Reinforcement Trans Reinforcement
TOP N/A Pedestal
N/A N/A N/A N/A N/A
BOTTOM 10 - 10 mm
Plan