0% found this document useful (0 votes)
84 views8 pages

WIKA S-11 Flush Pressure Transmitter

The WIKA model S-11 flush pressure transmitter is designed for measuring viscous and solids-containing media, suitable for various applications including machine building and the food industry. It features a flush diaphragm for cleanability, high accuracy, and multiple configurations, with options for high medium temperatures and FDA-compliant internal fluids. The device offers various measuring ranges and output signals, ensuring reliability in critical applications.

Uploaded by

luthfie.swacipta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
84 views8 pages

WIKA S-11 Flush Pressure Transmitter

The WIKA model S-11 flush pressure transmitter is designed for measuring viscous and solids-containing media, suitable for various applications including machine building and the food industry. It features a flush diaphragm for cleanability, high accuracy, and multiple configurations, with options for high medium temperatures and FDA-compliant internal fluids. The device offers various measuring ranges and output signals, ensuring reliability in critical applications.

Uploaded by

luthfie.swacipta
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

Electronic

pressure measurement

Flush pressure transmitter


For viscous and solids-containing media
Model S-11
WIKA data sheet PE 81.02

Applications

■■ Machine building
■■ Hydraulic aggregates
■■ General industrial applications
■■ Food and beverage industry

Special features

■■ High-quality product
■■ Many configurations possible
■■ Flush process connection
■■ Large stocks for short delivery times
■■ Vacuum-tight

Fig. left: Pressure transmitter model S-11


Fig. right: P
 ressure transmitter model S-11 with
cooling element

Description

Specialist for viscous and solids-containing media Flush process connection


The model S-11 pressure transmitter with flush diaphragm All process connections of the flush pressure transmitter are
has been specifically designed for the measurement of made of stainless steel, all welded and isolate the process
viscous, paste-like, adhesive, crystallising, particle-laden and medium from the pressure measuring instrument via a
contaminated media, which would clog the pressure channel positive seal. A reliable, dead-space free sealing between
of conventional process connections. the process connection and the measuring medium is thus
assured.
Through its optimised design, the flush process connection
enables the cleanability of the wetted diaphragm to be For high medium temperatures of up to 302 °F (150 °C),
integrated into the process. Low-maintenance and trouble- the pressure transmitter is also available with an integrated
free pressure measurement is thus also guaranteed in critical cooling element.
applications with frequently changing media.
Specifically for the food and beverage industry, a version
High accuracy, a robust design, high-quality workmanship with internal system fill fluid in accordance with FDA 21 CFR
and the high flexibility of configuration are key features of the 178.3750 can be chosen.
model S-11.

WIKA data sheet PE 81.02 ∙ 02/2016 Page 1 of 8

Data sheets showing similar products:


Pressure transmitter for general applications; model S-10; see data sheet PE 81.01
Intrinsically safe pressure transmitter; model IS-2X; see data sheet PE 81.50
Pressure transmitter for low pressure applications; model SL-1; see data sheet PE 81.36
Pressure transmitter for highest pressure applications; model HP-1; see data sheet PE 81.29
Measuring ranges

Gauge pressure
bar Measuring range 0 ... 0.1 0 ... 0.16 0 ... 0.25 0 ... 0.4 0 ... 0.6 0 ... 1 0 ... 1.6
Overpressure limit 1 1.5 2 2 4 5 10
Measuring range 0 ... 2.5 0 ... 4 0 ... 6 0 ... 10 0 ... 16 0 ... 25 0 ... 40
Overpressure limit 10 17 35 35 80 50 80
Measuring range 0 ... 60 0 ... 100 0 ... 160 0 ... 250 0 ... 400 0 ... 600
Overpressure limit 120 200 320 500 800 1,200
psi Measuring range 0 ... 15 0 ... 20 0 ... 30 0 ... 50 0 ... 60 0 ... 100 0 ... 150
Overpressure limit 145 145 145 240 240 500 500
Measuring range 0 ... 160 0 ... 200 0 ... 250 0 ... 300 0 ... 400 0 ... 500 0 ... 600
Overpressure limit 1,160 1,160 1,160 1,160 1,160 1,160 1,160
Measuring range 0 ... 750 0 ... 1,000 0 ... 1,500 0 ... 2,000 0 ... 3,000 0 ... 5,000 0 ... 6,000
Overpressure limit 1,740 1,740 2,900 4,600 7,200 11,600 11,600

Absolute pressure
bar Measuring range 0 ... 0.25 0 ... 0.4 0 ... 0.6 0 ... 1 0 ... 1.6 0 ... 2.5 0 ... 4
Overpressure limit 2 2 4 5 10 10 17
Measuring range 0 ... 6 0 ... 10 0 ... 16
Overpressure limit 35 35 80
psi Measuring range 0 ... 15 0 ... 25 0 ... 50 0 ... 100 0 ... 250
Overpressure limit 72.5 145 240 500 1,160

Vacuum and +/- measuring range


bar Measuring range -0.6 ... 0 -0.4 ... 0 -0.25 ... 0 -0.16 ... 0 -0.1 ... 0
Overpressure limit 4 2 2 1.5 1
Measuring range -1 ... 0 -1 ... +0.6 -1 ... +1.5 -1 ... +3 -1 ... +5
Overpressure limit 5 10 10 17 35
Measuring range -1 ... +9 -1 ... +15 -1 ... +24
Overpressure limit 35 80 50
psi Measuring range -30 inHg ... 0 -30 inHg ... +30 -30 inHg ... +60 -30 inHg ... +100 -30 inHg ... +160
Overpressure limit 72.5 240 240 500 1,160
Measuring range -30 inHg ... +200 -30 inHg ... +300
Overpressure limit 1,160 1,160

The given measuring ranges are also available in mbar, MPa and further units.

Vacuum tightness
Yes

Page 2 of 8 WIKA data sheet PE 81.02 ∙ 02/2016


Output signals Accuracy data

Signal type Signal Accuracy at reference conditions


Current (2-wire) 4 ... 20 mA Standard ≤ ±0.5 % of span
Current (3-wire) 0 ... 20 mA Option ≤ ±0.25 % of span 1)
Voltage (3-wire) DC 0 ... 10 V
1) Only for measuring ranges ≥ 0.25 bar
DC 0 ... 5 V
Including non-linearity, hysteresis, zero offset and end value
Other output signals on request. deviation (corresponds to measured error per IEC 61298-2).
Calibrated in vertical mounting position with process connec-
tion facing downwards.
Depending on the signal type the following loads apply:
Current (2-wire) ≤ (power supply - 10 V) / 0.02 A Non-linearity (per IEC 61298-2)
Current (3-wire) ≤ (power supply - 3 V) / 0.02 A ≤ ±0.2 % of span BFSL
Voltage (3-wire) > max. output signal / 1 mA
Non-repeatability
≤ ±0.1 % of span

Voltage supply Temperature error in rated temperature range


Rated temperature range:
Power supply 32 ... 176 °F (0 ... 80 °C)
The power supply depends on the selected output signal
Mean temperature coefficient of zero point:
4 ... 20 mA (2-wire) DC 10 ...30 V Measuring range > 0.25 bar ≤ 0.2 % of span/10 K
0 ... 20 mA (3-wire) DC 10 ...30 V Measuring range ≤ 0.25 bar < 0.4 % of span/10 K
DC 0 ... 10 V DC 14 ... 30 V
DC 0 ... 5 V DC 10 ...30 V Mean temperature coefficient of span:
≤ 0.2 % of span/10 K

Long-term drift
Reference conditions (per IEC 61298-1) ≤ ±0.2 % of span/year

Temperature Adjustability of zero point and span


59 ... 77 °F (15 ... 25 °C) Adjustment is made using potentiometers inside the
instrument.
Atmospheric pressure Not possible for cable outlet with ingress protection IP 68.
12.47 ... 15.37 psi (860 ... 1,060 mbar)
Zero point ± 5 %
Humidity Span ±5%
45 ... 75 % r. h.

Power supply
DC 24 V
Time response
Mounting position
Calibrated in vertical mounting position with process Settling time
connection facing downwards. ≤ 10 ms

WIKA data sheet PE 81.02 ∙ 02/2016 Page 3 of 8


Operating conditions Electrical connections

Ingress protection (per IEC 60529) Short-circuit resistance


The ingress protection depends on the type of electrical S+ vs. U-
connection.
Reverse polarity protection
Electrical connection Ingress protection
U+ vs. U-
Angular connector DIN 175301-803 A IP 65
Circular connector M12 x 1 (4-pin) IP 67 Overvoltage protection
Cable outlet
DC 36 V
■■ Standard IP 67
■■ Option IP 68 2)
Insulation voltage
2) Adjustability of zero point and span not possible.
DC 500 V with NEC class 02 voltage supply (low voltage and
The stated ingress protection only applies when plugged in low current max. 100 VA even under fault conditions)
using mating connectors that have the appropriate ingress
protection. Connection diagrams

Vibration resistance
Angular connector DIN 175301-803 A
Process connections without cooling element:
2-wire 3-wire
20 g (IEC 60068-2-6, under resonance)
U+ 1 1
Process connections with cooling element: 1
3 U- 2 2
10 g (IEC 60068-2-6, under resonance) 2
S+ - 3
Shock resistance Wire cross-section max. 1.5 mm (AWG 16)
2

Process connections without cooling element: Cable diameter 6 ... 8 mm (0.24 ... 0.31")
1,000 g (IEC 60068-2-27, mechanical)
Circular connector M12 x 1 (4-pin)
Process connections with cooling element: 2-wire 3-wire
400 g (IEC 60068-2-27, mechanical)
U+ 1 1
4 3
U- 3 3
1 2
Permissible temperature ranges S+ - 4
Also meets EN 50178, tab. 7, operation (C) 4K4H,
storage (D) 1K4, transport (E) 2K3. Cable outlet
2-wire 3-wire
Process connections without cooling element
U+ brown brown
Medium
■■ Standard -30 ... +100 °C -22 ... +212 °F U- green green
■■ Option -30 ... +125 °C -22 ... +257 °F
S+ - white
Ambient -20 ... +80 °C -4 ... +176 °F
Storage -40 ... +100 °C -40 ... +212 °F Shield grey grey
Wire cross-section 6 x 0.5 mm² (AWG 20)
Process connections with cooling element Cable diameter 6.8 mm (0.27")
Cable lengths 1.5 m, 3 m, 5 m, 10 m, 15 m
Medium -20 ... +150 °C -4 ... +302 °F
(4.9 ft, 9.8 ft, 16.4 ft, 32.8 ft, 49.2 ft)
Ambient -20 ... +80 °C -4 ... +176 °F
Storage -40 ... +100 °C -40 ... +212 °F Other connections on request.

Page 4 of 8 WIKA data sheet PE 81.02 ∙ 02/2016


Process connections

Process connection Available measuring ranges


G ½ B flush 3) 0 ... 2.5 to 0 ... 600 bar 0... 50 to 0 ... 6,000 psi
G 1 B flush 3) 0 ... 0.1 to 0 ... 1.6 bar 0 ... 15 psi
Hygienic G 1 B flush 0 ... 0.1 to 0 ... 25 bar 0 ... 15 to 0 ... 300 psi, respectively
(in accordance with 3-A Sanitary
Standards)
3) Process connection also available with cooling element.

Cooling elements
For higher medium temperatures process connections with cooling element are available (see
“Operating conditions”) .

Sealing
Process Max. medium Sealing material and max. pressure limitation
connection temperature Standard Option 1 Option 2
without cooling up to 212 °F (100 °C) NBR FKM/FPM 4) EPDM
element up to 8,700 psi (600 bar) up to 8,700 psi (600 bar) up to 2,900 psi (200 bar)
up to 257 °F (125 °C) NBR FKM/FPM 4) EPDM
up to 8,700 psi (600 bar) up to 5,800 psi (400 bar) up to 2,900 psi (200 bar)
with cooling up to 302 °F (150 °C) FKM/FPM 4) EPDM -
element up to 4,350 psi (300 bar) up to 2,900 psi (200 bar)
Hygienic up to 302 °F (150 °C) EPDM - -
up to 2,900 psi (200 bar)
4) Minimum permissible medium and ambient temperature -20 °C / -4 °F

The sealings listed under “Standard” are included in the delivery.

Materials

Wetted parts
■■ Stainless steel
■■ For sealing materials see “Process connections”

Non-wetted parts

Internal system fill fluid


Standard Synthetic oil
Option Food-compatible system fill fluid per FDA 21 CFR
178.3750

WIKA data sheet PE 81.02 ∙ 02/2016 Page 5 of 8


CE conformity

Pressure equipment directive


97/23/EC

EMC directive
2004/108/EC, EN 61326 emission (group 1, class B) and
interference immunity (industrial application)

Approvals
■■ CSA, safety (e.g. electr. safety, overpressure, ...), Canada
■■ GOST-R, import certificate, Russia
■■ GOST, metrology/measurement technology, Russia
■■ 3-A 5), food, USA
■■ CRN, safety (e.g. electr. safety, overpressure, ...), Canada

5) 3-A only for instruments with hygienic process connection G 1 B

Approvals, see website

Page 6 of 8 WIKA data sheet PE 81.02 ∙ 02/2016


Dimensions in mm (inch)

Pressure transmitter

with angular connector DIN 175301-803 with M12 x 1 circular connector with cable outlet
A

Weight approx. 0.2 kg / 7 oz Weight approx. 0.2 kg / 7 oz Weight approx. 0.2 kg / 7 oz

Process connections

G D1 L1 L2 L3 L4 G D1 L1 L2 L3 L4 G D1 L1 L2 L3 L4
G ½ B 18 23 20.5 10 15.5 G 1 B 30 23 20.5 10 15.5 G1B 29.5 28 25 9 15.5
(0.71) (0.91) (0.81) (0.4) (0.61) (1.19) (0.91) (0.81) (0.4) (0.61) hygienic (1.17) (1.11) (0.99) (0.36) (0.61)

For information on tapped holes and welding sockets, see Technical information IN 00.14 at [Link].

WIKA data sheet PE 81.02 ∙ 02/2016 Page 7 of 8


Accessories

Welding socket

Designation Order no.


Welding socket for G ½ B flush 1192299
Welding socket for G 1 B flush 1192264
Welding socket for G 1 B hygienic flush 14070973
Welding socket for G 1 B hygienic flush with leak-control channel 14070974

Further adapter systems for for measuring instruments with process connection G 1 B hygienic, see data sheet AC 09.20.

Mating connector

Designation Order no.


without cable 2 m cable, shielded 5 m cable, shielded 10 m cable, shielded
Angular connector DIN 175301-803 A
■■ with cable gland, metric 11427567 14100465 14100466 -
■■ with cable gland, conduit 11022485 - - -
Circular connector M12 x 1 (4-pin)
■■ straight - 14086880 14086883 14086884
■■ angled - 14086889 14086891 14086892

Sealings for mating connectors

Mating connector Order no.


Blue (WIKA) Brown (neutral)
Angular connector DIN EN 175301-803 A 1576240 11437902

Sealings for process connection

Thread size and sealing Order no.


NBR FPM/FKM EPDM
G½B
■■ O-ring 14072275 14072276 14072277
■■ Profile sealing 1039067 1039075 1538306
G1B
■■ O-ring 1108247 1099094 1535056
■■ Profile sealing 1100386 1145967 11522381
G 1 B hygienic
■■ O-ring - - 2225859
■■ Profile sealing - - 11522381

Ordering information
MM/YYYY country code based on 07/2014 GB

Model / Measuring range / Output signal / Accuracy / Electrical connection / Medium temperature / Process connection /
Sealing / System fill fluid

© 2012 WIKA Alexander Wiegand SE & Co. KG, all rights reserved.
The specifications given in this document represent the state of engineering at the time of publishing.
We reserve the right to make modifications to the specifications and materials.

Page 8 of 8 WIKA data sheet PE 81.02 ∙ 02/2016

WIKA Instrument Corporation


1000 Wiegand Boulevard
Lawrenceville, GA 30043-5868
Tel: 888-WIKA-USA • 770-513-8200
Fax: 770-338-5118
E-Mail: info@[Link]