GST : 36AFQPA0241Q2Z9
Email : [email protected]
SOLAR LED TECHNOLOGY Mobile : 91 8686012179
Address: #151 CTC Park lane
Secunderabad-03
SOLAR PV EPC WORK
Customized Price Sheet: 1 MW Solar Plant AMC
Rate Amount
Item Scope / Description Unit Qty
(INR) (INR)
1. Monthly Module Wet cleaning of all modules
Visits/Year 24 12,000 2,88,000
Cleaning (approx. 3000–3300 modules)
Monthly preventive check of
2. Preventive
DC/AC side, combiner boxes, Visits/Year 12 10,000 1,20,000
Maintenance
etc.
Quarterly service of inverters
3. Inverter Service Visits/Year 4 15,000 60,000
(assumed 10 inverters)
4. Earth Pit Resistance
Half-yearly testing and report Visits/Year 2 5,000 10,000
Testing
5. Thermographic Annual thermal scan of
Per Year 1 15,000 15,000
Inspection modules and cables
6. SCADA Monitoring Daily performance monitoring
Per Month 12 5,000 60,000
& Reporting + monthly report
Quarterly grass trimming & site
7. Vegetation Control Visits/Year 4 7,500 30,000
cleanup
8. Emergency 3 Free Visits (additional @
Per Visit 3 Included -
Breakdown Visits ₹7,500 each)
1 Site engineer + 1 Technician
9. Manpower for O&M Days/Year 24 3,500 84,000
(for 2 days/month)
| Total Estimated AMC Charges (Excl. GST) | | | | | ₹6,67,000 |
💡 Optional Add-ons (charged separately):
Spare parts (MC4s, fuses, breakers): ₹25,000–₹50,000/year as per usage
Insurance assistance: ₹10,000/year
Online weather station maintenance: ₹8,000/year
🔧 Vendor Scope of Work
A. Routine Maintenance
Fortnightly cleaning of modules
Monthly inspection of cables, fuses, MC4 connectors
Checking inverter log, alerts, and synchronisation status
GST : 36AFQPA0241Q2Z9
Email :
[email protected] SOLAR LED TECHNOLOGY Mobile : 91 8686012179
Address: #151 CTC Park lane
Secunderabad-03
SOLAR PV EPC WORK
LT/HT panel checkups and transformer oil level
Data logging and SCADA performance analysis
B. Corrective Maintenance
Identification and isolation of faults (string, inverter, or connection)
Coordination with OEM for component under warranty
Emergency repair/replacement (within 48 hours response time)
C. Reporting
Daily generation and performance reporting (via SCADA)
Monthly technical reports and PR analysis
Annual system health check report
D. Manpower Responsibility
Onsite supervision by trained O&M engineer
Technicians available for regular and emergency work
Coordination with DISCOM and plant owner
E. General Terms
Validity: 12 months
Uptime commitment: ≥98.5%
GST extra as applicable (18%)
Payment: 50% advance, 25% mid-year, 25% on completion
Penalty: 0.5% per day for major unattended issues beyond 3 days