0% found this document useful (0 votes)
22 views1 page

1st Slab Beam Details

The document provides detailed specifications for various structural components, including dimensions and reinforcement details for beams labeled B1 to B7. Each beam section includes information on steel types and spacing, with specific measurements noted. Additionally, it outlines project details such as the plot area, built-up area, location, and client information for a residential house project in Aziz Nagar.

Uploaded by

sjreddy2727
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views1 page

1st Slab Beam Details

The document provides detailed specifications for various structural components, including dimensions and reinforcement details for beams labeled B1 to B7. Each beam section includes information on steel types and spacing, with specific measurements noted. Additionally, it outlines project details such as the plot area, built-up area, location, and client information for a residential house project in Aziz Nagar.

Uploaded by

sjreddy2727
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

B1:-[9"X20"] B1:-[9"X20"]

14'-5" 1"
15'-102
3'-421'
3-T 16 St+ 3-T16 St+ 3-T 16 St+ 3-T16 St+ 3-T 16 St+
3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

3-T 16 St+ 3-T 16 St+ 3-T 16 St+


3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

Ø8mm @ 6"c/c Ø8mm @ 6"c/c Ø8mm @ 6"c/c

B2:-[9"X20"] B2:-[9"X20"]
14'-5" 1"
15'-102
3'-421'
3-T 16 St+ 3-T16 St+ 3-T 16 St+ 3-T16 St+ 3-T 16 St+
3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

3-T 16 St+ 3-T 16 St+ 3-T 16 St+


3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

Ø8mm @ 6"c/c Ø8mm @ 6"c/c Ø8mm @ 6"c/c

B3:-[9"X20"] B3:-[9"X20"]
14'-5" 1"
15'-102
3'-421'
3-T 16 St+ 3-T16 St+ 3-T 16 St+ 3-T16 St+ 3-T 16 St+
3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

3-T 16 St+ 3-T 16 St+ 3-T 16 St+


3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

Ø8mm @ 6"c/c Ø8mm @ 6"c/c Ø8mm @ 6"c/c

B4:-[9"X20"] B4:-[9"X20"]
14'-5" 1"
15'-102
3'-421'
3-T 16 St+ 3-T16 St+ 3-T 16 St+ 3-T16 St+ 3-T 16 St+
3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

3-T 16 St+ 3-T 16 St+ 3-T 16 St+


3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

Ø8mm @ 6"c/c Ø8mm @ 6"c/c Ø8mm @ 6"c/c

B5:-[9"X20"] B5:-[9"X20"] B5:-[9"X20"]


12'-7" 15'-3" 14'-5"

3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+
3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

3-T 16 St+ 3-T 16 St+ 3-T 16 St+


3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

Ø8mm @ 8"c/c Ø8mm @ 8"c/c Ø8mm @ 8"c/c

B6:-[9"X20"] B6:-[9"X20"] B6:-[9"X20"] B6:-[9"X20"]


7'-6" 12'-7" 15'-3" 14'-5"

3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+
3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

3-T 16 St+ 3-T 16 St+ 3-T 16 St+


3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

Ø8mm @ 8"c/c Ø8mm @ 8"c/c Ø8mm @ 8"c/c Ø8mm @ 8"c/c

B7:-[9"X20"] B7:-[9"X20"] B7:-[9"X20"] B7:-[9"X20"]


7'-6" 12'-7" 15'-3" 14'-5"

3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+ 3-T 16 St+
3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

3-T 16 St+ 3-T 16 St+ 3-T 16 St+


3-T 16 Ext 3-T 16 Ext 3-T 16 Ext

Ø8mm @ 8"c/c Ø8mm @ 8"c/c Ø8mm @ 8"c/c Ø8mm @ 8"c/c

AREA CLIENT:

Mr. AKHILESHWAR REDDY


PLOT AREA: 220.0 [Link]

BUILT UP AREA: 1691 SFT

LOCATION PROJECT: ORIENTATION


AZIZ NAGAR RESI HOUSE
Construction N
DRAWN BY: Ar. [Link] Reddy
CHECKED BY: [Link] Reddy ISSUED FOR SHEET TITLE:
PROJECT HEAD: [Link] Reddy 1ST SLAB BEAM DETAILS
Construction Review

ISSUE DATE: 29.03.2025 Permission Vendor