Case Study Report – Ground-Mounted Solar Power Plant
1. Project Overview
Project Name: 10 MW Ground-Mounted Solar PV Project
Location: [Insert Location – Village, Taluka, District, State]
Developer/EPC Contractor: [Company Name]
Date of Commissioning: [Insert Date]
Client/Owner: [Client Name]
Project Capacity: 10 MW (AC)
Type: Grid-connected, Ground-mounted
Technology Used: Crystalline PV Modules, String Inverters
2. Objective
The primary objective of this project is to harness solar energy by installing a 10 MW
ground-mounted photovoltaic (PV) system to supply clean and sustainable power to the
grid and reduce carbon emissions.
3. Site Details
Parameter Description
Land Area ~50 Acres
Topography Flat/Rolling
Soil Type Black Cotton / Laterite / Sandy
Accessibility Well connected by road
Grid Connectivity 33 kV HT line connected to substation [X
km away]
Climatic Conditions High solar irradiation zone (kWh/m²/day)
4. Design and Engineering
Module Capacity: 550 Wp (Mono PERC)
Total Modules: Approx. 18,200 Nos
Inverters: 30 x 320 kW String Inverters
Mounting Structure: Galvanized Iron Fixed Tilt (25°)
Tilt & Orientation: South-facing, optimal tilt for latitude
SCB/ACDB Panels: Integrated for each block
Earthing & Lightning Protection: GI Strip Earth mat & ESE Lightning Arrester system
Transmission Line: 11/33 kV – distance of ~3.5 km
SCADA/Remote Monitoring: Enabled
5. Installation and Commissioning
- Land Development: Clearing, grading, fencing
- Structure Installation: Pile foundation + MMS erection
- Module Mounting: 3 modules per table (example)
- String Formation: 26 modules per string
- DC Cabling: Laid via cable trenches with protection
- Inverter Installation: Mounted on RCC plinths with canopies
- AC Cabling & Evacuation: Through HT panels to substation
- Commissioning: Performance testing, grid synchronization
6. Operation and Maintenance
- Daily performance monitoring via SCADA
- Cleaning cycle based on soiling ratio
- Periodic preventive maintenance
- Inverter log review, IV curve tracing
- Vegetation and module cleaning management
- Safety audits and equipment health checks
7. Performance
CUF (Capacity Utilization Factor): ~19% annually
Annual Energy Generation: ~17.5 million units (kWh)
PR (Performance Ratio): 78–82%
CO₂ Offset: ~14,000 tons/year
8. Challenges and Solutions
Challenge Solution
Undulating land Adjusted MMS design & pile height
Monsoon soil erosion Installed stone pitching & drains
Delay in transmission line Temporary genset-based testing setup
9. Conclusion
The 10 MW Ground-Mounted Solar Power Plant has been successfully commissioned and is
contributing clean energy to the grid. The plant has demonstrated strong performance,
minimal maintenance issues, and a high level of reliability, marking it a successful case of
sustainable energy deployment.