Control Components
Control Components
Specifications
Main
Range of product TeSys Deca
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Device short name LC1D
Poles description 3P
[Ie] rated operational current 9 A (at <60 °C) at <= 440 V AC AC-3 for power circuit
25 A (at <60 °C) at <= 440 V AC AC-1 for power circuit
9 A (at <60 °C) at <= 440 V AC AC-3e for power circuit
Complementary
Motor power kW 2.2 kW at 220...230 V AC 50/60 Hz (AC-3)
4 kW at 380...400 V AC 50/60 Hz (AC-3)
4 kW at 415...440 V AC 50/60 Hz (AC-3)
5.5 kW at 500 V AC 50/60 Hz (AC-3)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3)
2.2 kW at 400 V AC 50/60 Hz (AC-4)
2.2 kW at 220...230 V AC 50/60 Hz (AC-3e)
4 kW at 380...400 V AC 50/60 Hz (AC-3e)
4 kW at 415...440 V AC 50/60 Hz (AC-3e)
5.5 kW at 500 V AC 50/60 Hz (AC-3e)
5.5 kW at 660...690 V AC 50/60 Hz (AC-3e)
[Ith] conventional free air thermal 25 A (at 60 °C) for power circuit
current 10 A (at 60 °C) for signalling circuit
Irms rated making capacity 250 A at 440 V for power circuit conforming to IEC 60947
140 A AC for signalling circuit conforming to IEC 60947-5-1
250 A DC for signalling circuit conforming to IEC 60947-5-1
Rated breaking capacity 250 A at 440 V for power circuit conforming to IEC 60947
Feb 3, 2025 AD 1
[Icw] rated short-time withstand 105 A 40 °C - 10 s for power circuit
current 210 A 40 °C - 1 s for power circuit
30 A 40 °C - 10 min for power circuit
61 A 40 °C - 1 min for power circuit
100 A - 1 s for signalling circuit
120 A - 500 ms for signalling circuit
140 A - 100 ms for signalling circuit
[Ui] rated insulation voltage Power circuit: 690 V conforming to IEC 60947-4-1
Power circuit: 600 V CSA certified
Power circuit: 600 V UL certified
Signalling circuit: 690 V conforming to IEC 60947-1
Signalling circuit: 600 V CSA certified
Signalling circuit: 600 V UL certified
pollution degree 3
2 Feb 3, 2025 AD
Connections - terminals Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without
cable end
Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without
cable end
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable
end
Power circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with
cable end
Power circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable
end
Power circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable
end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without
cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without
cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable
end
Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with
cable end
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without
cable end
Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without
cable end
Tightening torque Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver flat Ø 6 mm
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver Philips No 2
Control circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Power circuit: 1.7 N.m - on screw clamp terminals - with screwdriver pozidriv No 2
Environment
Standards CSA C22.2 No 14
EN 60947-4-1
EN 60947-5-1
IEC 60947-4-1
IEC 60947-5-1
UL 60947-4-1
IEC 60335-1:Clause 30.2
IEC 60335-2-40:Annex JJ
UL 60335-2-40:Annex JJ
CSA C22.2 No 60947-4-1
Product certifications UL
CCC
CSA
Marine
UKCA
EAC
CB Scheme
Feb 3, 2025 AD 3
Permissible ambient air -40…60 °C
temperature around the device 60…70 °C with derating
Height 77 mm
Width 45 mm
Depth 86 mm
Packing Units
Unit Type of Package 1 PCE
Contractual warranty
Warranty 18 months
4 Feb 3, 2025 AD
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Use Again
Take-back No
Feb 3, 2025 AD 5
Product datasheet LC1D09M7
Dimensions Drawings
Dimensions
6 Feb 3, 2025 AD
Product datasheet LC1D09M7
Wiring
Feb 3, 2025 AD 7
Product datasheet
Specifications
Main
Range TeSys Deca
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Motor circuit breaker
Complementary
Poles description 3P
network type AC
[Ics] rated service short-circuit 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
03-Feb-2025 1
Phase failure sensitivity Yes conforming to IEC 60947-4-1
Width 45 mm
Height 89 mm
Depth 78.5 mm
Environment
Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
IEC/EN 60335-2-40:Annex JJ
IEC/EN 60335-1:Clause 30.2
Packing Units
Unit Type of Package 1 PCE
2 03-Feb-2025
Package 1 Length 9.000 cm
Contractual warranty
Warranty 18 months
03-Feb-2025 3
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Use Again
Take-back No
4 03-Feb-2025
Product datasheet GV2ME06
Performance Curves
Current Limitation on Short-Circuit for GV2ME and GV2P (3-Phase 400/415 V))
Dynamic Stress
I peak = f (prospective Isc) at 1.05 Ue = 435 V
03-Feb-2025 5
Product datasheet GV2ME06
2 24-32 A
3 20-25 A
4 17-23 A
5 13-18 A
6 9-14 A
7 6-10 A
8 4-6.3 A
9 2.5-4 A
10 1.6-2.5 A
11 1-1.6 A
12 Limit of rated ultimate breaking capacity on short-circuit of GV2ME (14, 18, 23, and 25 A ratings).
6 03-Feb-2025
Product datasheet GV2ME06
1 24-32 A
2 20-25 A
3 17-23 A
4 13-18 A
5 9-14 A
6 6-10 A
7 4-6.3 A
8 2.5-4 A
9 1.6-2.5 A
10 1-1.6 A
03-Feb-2025 7
Product datasheet GV2ME06
Dimensions Drawings
Dimension
GV2ME
(1) Maximum
GV2ME●● 89
GV2ME●●3 101
Mounting
GV2ME
On 35 mm rail
8 03-Feb-2025
Product datasheet GV2ME06
GV2AF01
Combination GV2ME + TeSys k contactor
GV2AF3
Combination GV2ME + TeSys d contactor
b 176.4 186.8
c1 94.1 100.4
c 99.6 105.9
GV2AF4 + LAD311
Combination GV2ME + TeSys d contactor
03-Feb-2025 9
Product datasheet GV2ME06
b 176.4 186.8
c1 103.1 136.4
c 135.6 141.9
d1 107 107
d 112.5 112.5
10 03-Feb-2025
Product datasheet GV2ME06
Connection of Undervoltage Trip for Dangerous Machines (Conforming to INRS) on GV2ME Only
03-Feb-2025 11
Product datasheet
Specifications
Main
Range TeSys Deca
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Motor circuit breaker
Complementary
Poles description 3P
network type AC
[Ics] rated service short-circuit 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
03-Feb-2025 1
Power dissipation per pole 2.5 W
Width 45 mm
Height 89 mm
Depth 78.5 mm
Environment
Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
IEC/EN 60335-2-40:Annex JJ
IEC/EN 60335-1:Clause 30.2
Packing Units
Unit Type of Package 1 PCE
2 03-Feb-2025
Package 1 Weight 216.000 g
Contractual warranty
Warranty 18 months
03-Feb-2025 3
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Use Again
Take-back No
4 03-Feb-2025
Product datasheet GV2ME04
Performance Curves
Current Limitation on Short-Circuit for GV2ME and GV2P (3-Phase 400/415 V))
Dynamic Stress
I peak = f (prospective Isc) at 1.05 Ue = 435 V
03-Feb-2025 5
Product datasheet GV2ME04
2 24-32 A
3 20-25 A
4 17-23 A
5 13-18 A
6 9-14 A
7 6-10 A
8 4-6.3 A
9 2.5-4 A
10 1.6-2.5 A
11 1-1.6 A
12 Limit of rated ultimate breaking capacity on short-circuit of GV2ME (14, 18, 23, and 25 A ratings).
6 03-Feb-2025
Product datasheet GV2ME04
1 24-32 A
2 20-25 A
3 17-23 A
4 13-18 A
5 9-14 A
6 6-10 A
7 4-6.3 A
8 2.5-4 A
9 1.6-2.5 A
10 1-1.6 A
03-Feb-2025 7
Product datasheet GV2ME04
Dimensions Drawings
Dimension
GV2ME
(1) Maximum
GV2ME●● 89
GV2ME●●3 101
Mounting
GV2ME
On 35 mm rail
8 03-Feb-2025
Product datasheet GV2ME04
GV2AF01
Combination GV2ME + TeSys k contactor
GV2AF3
Combination GV2ME + TeSys d contactor
b 176.4 186.8
c1 94.1 100.4
c 99.6 105.9
GV2AF4 + LAD311
Combination GV2ME + TeSys d contactor
03-Feb-2025 9
Product datasheet GV2ME04
b 176.4 186.8
c1 103.1 136.4
c 135.6 141.9
d1 107 107
d 112.5 112.5
10 03-Feb-2025
Product datasheet GV2ME04
Connection of Undervoltage Trip for Dangerous Machines (Conforming to INRS) on GV2ME Only
03-Feb-2025 11
Product datasheet
Specifications
Main
Range TeSys Deca
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Device short name GV2ME
Complementary
Poles description 3P
network type AC
[Ics] rated service short-circuit 100 % at 230/240 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity 100 % at 400/415 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 440 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 500 V AC 50/60 Hz conforming to IEC 60947-2
100 % at 690 V AC 50/60 Hz conforming to IEC 60947-2
Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
Feb 3, 2025 1
Power dissipation per pole 2.5 W
Width 45 mm
Height 89 mm
Depth 78.5 mm
Environment
Standards EN/IEC 60947-2
EN/IEC 60947-4-1
UL 60947-4-1
CSA C22.2 No 60947-4-1
IEC/EN 60335-2-40:Annex JJ
IEC/EN 60335-1:Clause 30.2
Packing Units
Unit Type of Package 1 PCE
2 Feb 3, 2025
Unit Type of Package 2 S02
Package 2 Height 15 cm
Package 2 Width 30 cm
Package 2 Length 40 cm
Package 3 Height 75 cm
Package 3 Width 60 cm
Package 3 Length 80 cm
Contractual warranty
Warranty 18 months
Feb 3, 2025 3
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Use Again
Take-back No
4 Feb 3, 2025
Product datasheet GV2ME03
Performance Curves
Current Limitation on Short-Circuit for GV2ME and GV2P (3-Phase 400/415 V))
Dynamic Stress
I peak = f (prospective Isc) at 1.05 Ue = 435 V
Feb 3, 2025 5
Product datasheet GV2ME03
2 24-32 A
3 20-25 A
4 17-23 A
5 13-18 A
6 9-14 A
7 6-10 A
8 4-6.3 A
9 2.5-4 A
10 1.6-2.5 A
11 1-1.6 A
12 Limit of rated ultimate breaking capacity on short-circuit of GV2ME (14, 18, 23, and 25 A ratings).
6 Feb 3, 2025
Product datasheet GV2ME03
1 24-32 A
2 20-25 A
3 17-23 A
4 13-18 A
5 9-14 A
6 6-10 A
7 4-6.3 A
8 2.5-4 A
9 1.6-2.5 A
10 1-1.6 A
Feb 3, 2025 7
Product datasheet GV2ME03
Dimensions Drawings
Dimension
GV2ME
(1) Maximum
GV2ME●● 89
GV2ME●●3 101
Mounting
GV2ME
On 35 mm rail
8 Feb 3, 2025
Product datasheet GV2ME03
GV2AF01
Combination GV2ME + TeSys k contactor
GV2AF3
Combination GV2ME + TeSys d contactor
b 176.4 186.8
c1 94.1 100.4
c 99.6 105.9
GV2AF4 + LAD311
Combination GV2ME + TeSys d contactor
Feb 3, 2025 9
Product datasheet GV2ME03
b 176.4 186.8
c1 103.1 136.4
c 135.6 141.9
d1 107 107
d 112.5 112.5
10 Feb 3, 2025
Product datasheet GV2ME03
Connection of Undervoltage Trip for Dangerous Machines (Conforming to INRS) on GV2ME Only
Feb 3, 2025 11
Product datasheet
Specifications
Main
Range TeSys
TeSys Deca
Disclaimer: This documentation is not intended as a substitute for and is not to be used for determining suitability or reliability of these products for specific user applications
Product or component type Auxiliary contact block
Complementary
[Ui] rated insulation voltage 690 V conforming to IEC 60947-1
300 V conforming to UL 508
300 V conforming to CSA C22.2 No 14
Price is “List Price” and may be subject to a trade discount – check with your local distributor or retailer for actual price.
Feb 3, 2025 1
Rated operational power in W 120 W at 240 V DC-13 - electrical durability: 100000 cycles
140 W at 110 V DC-13 - electrical durability: 100000 cycles
140 W at 24 V DC-13 - electrical durability: 100000 cycles
180 W at 60 V DC-13 - electrical durability: 100000 cycles
240 W at 48 V DC-13 - electrical durability: 100000 cycles
15 W at 48 V DC-13 - electrical durability: 1000 cycles
24 W at 24 V DC-13 - electrical durability: 1000 cycles
9 W at 60 V DC-13 - electrical durability: 1000 cycles
Height 89 mm
Width 9.3 mm
Depth 66 mm
Environment
Environmental characteristic Normal environment
Packing Units
Unit Type of Package 1 PCE
Contractual warranty
Warranty 18 months
2 Feb 3, 2025
Environmental Data
Schneider Electric aims to achieve Net Zero status by 2050 through supply chain partnerships, lower impact materials, and circularity
via our ongoing “Use Better, Use Longer, Use Again” campaign to extend product lifetimes and recyclability.
Environmental footprint
Use Better
Use Again
Take-back No
Feb 3, 2025 3
Product datasheet GVAD1010
GVAD1010
4 Feb 3, 2025