Gonzaga - e Plan

The document outlines the electrical layout plan for a one-storey building, detailing compliance with the Philippine Electrical Code and local regulations. It specifies requirements for materials, wiring, and installation practices, including the use of copper wires and electronic ballasts. Additionally, it provides guidelines for the proper placement of electrical devices and the responsibilities of the contractor in ensuring adherence to the plans and specifications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
24 views1 page

Gonzaga - e Plan

The document outlines the electrical layout plan for a one-storey building, detailing compliance with the Philippine Electrical Code and local regulations. It specifies requirements for materials, wiring, and installation practices, including the use of copper wires and electronic ballasts. Additionally, it provides guidelines for the proper placement of electrical devices and the responsibilities of the contractor in ensuring adherence to the plans and specifications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

ENTRANCE

GENERAL NOTES:
12W LED ENTRANCE
1. ALL ELECTRICAL WORKS HEREIN SHALL BE DONE IN ACCORDANCE WITH THE PROVISION OF THE
LATEST EDITION OF THE PHILIPPINE ELECTRICAL CODE, REQUIREMENTS OF THE LOCAL POWER
s2 s2
COMPANIES, RULES AND REGULATIONS OF THE LOCAL ENFORCING AUTHORITIES.
PBB PBB
2. ALL ELECTRICAL WORKS HEREIN INCLUDED SHALL BE EXECUTED BY PERSONNEL WITH ELECTRICAL
3W PL 3W PL PBB EXPERIENCE UNDER THE DIRECT SUPERVISION OF A FULL TIME LICENSED ELECTRICAL ENGINEER.
C2 WORKS SHALL BE NEATLY PLACED, SECURELY FASTENED AND PROPERLY FINISHED.

DCO 3. THE TYPE OF POWER SERVICE SHALL BE 230 VAC, SINGLE PHASE, 60 HZ, 2-WIRE PLUS GROUND.

12W LED
DCO
+300mm
+300mm
4. THE CONTRACTOR SHALL VERIFY AND ORIENT THE ACTUAL LOCATION OF SERVICE ENTRANCE FOR
CONNECTION TO POWER SUPPLY & COMMUNICATION.

3W PL 3W PL 5. ALL MATERIALS SHALL BE BRAND NEW & SHALL CONFORM WITH THE PROVISIONS OF THE UNDER
WRITERS LABORATORIES INC., IN EVERY CASE WHERE SUCH A STANDARD HAS BEEN ESTABLISHED.

6. UNLESS OTHERWISE SPECIFIED, ALL ELECTRICAL WIRING INSTALLATION FOR LIGHTING & POWER
SHALL USE RSC, FOR AUXILIARY SYSTEM USE PVC. THE MINIMUM SIZE OF CONDUIT SHALL BE
12W LED 15mmØ.
DCO
12W LED DCO
+300mm
+300mm 7. ALL WIRE SHALL BE COPPER AND THERMOPLASTIC INSULATED TYPE "THHN". THE MINIMUM SIZE
FOR LIGHTING & POWER SHALL BE 3.5 SQ.MM & SHALL BE MANUFACTURED BY PHELPS DODGE.

12W LED 8. COLOR CODING OF WIRES AND CABLES SHALL BE AS FOLLOWS :


PHASES - BLACK, GROUND - GREEN

12W LED s3 9. PROVIDE ADEQUATE AND EFFECTIVE GROUNDING SYSTEM TO ALL LIGHTING AND POWER CIRCUIT
AS PER PHILIPPINE ELECTRICAL CODE REQUIREMENT.

+300mm 10. CONVENIENCE OUTLET FOR GENERAL USE SHALL BE DUPLEX 15A, 250 VOLTS, GROUNDING TYPE,

C1 DCO LIGHT SWITCHES SHALL BE 15A, 250 VOLTS.

PBB 11. ALL OUTLET BOXES SHALL BE GALVANIZED GAGE NO. 16, DEEP TYPE WITH FACTORY KNOCKOUTS.

12. PULLBOXES SHALL BE USED WHEN APPLICABLE FOR EASY PULLING OF WIRES AND SHALL BE IN
ACCORDANCE WITH THE PHILIPPINE ELECTRICAL CODE REQUIREMENT.

13. ALL ELECTRICAL PANELBOARD AND CIRCUIT BREAKERS SHALL BE "SQUARE D", BOLT-ON TYPE.
s1 s1
15W LED 14. ALL ELECTRICAL CIRCUITS SHALL BE WIRED ACCORDING TO THE PANELBOARD LOAD SCHEDULE.
15W LED
s1 15. ALL MOUNTING HEIGHTS OF DEVICES SHALL BE AS FOLLOWS :
12W LED (SUBJECT TO ARCHITECT'S APPROVAL PRIOR TO INSTALLATION)

DCO
+300mm
DCO
+300mm
A. PANELBOARD
B. SWITCH
- 1.40 M CENTER OF THE FINISHED FLOOR
- 1.00 M ABOVE FINISHED FLOOR TO CENTER OF THE DEVICE
C. CONVENIENCE OUTLET - 0.30 M ABOVE FINISHED FLOOR TO CENTER OF THE DEVICE
D. COUNTER HEIGHT C.O. - 0.20 M FROM FINISHED COUNTER HT. TO THE CENTER OF DEVICE

E3 GROUND FLOOR : LIGHTING LAYOUT E3 GROUND FLOOR : POWER LAYOUT 16. THE PLANS AS DRAWN ARE BASED UPON THE ARCHITECTURAL PLANS & THE DETAILS & SHOWN
24 SCALE: 1:100 MTS CONDITION AS ACCURATELY AS IT IS POSSIBLE TO INDICATE THEM IN SCALE. THE PLANS ARE
14 1:100 MTS SCALE:
DIAGRAMMATICAL AND DOES NOT NECESSARILY SHOW ALL FITTINGS NECESSARY TO FIT TO THE
BUILDING CONDITIONS. THE LOCATIONS OF OUTLETS, APPARATUS AND APPLIANCES SHOWN ON
THE PLANS ARE APPROXIMATE. THE CONTRACTOR SHALL BE HELD RESPONSIBLE FOR THEIR
PROPER LOCATION IN ORDER TO MAKE THEM FIT WITH THE ARCHITECTURAL DETAILS AND
INSTRUCTIONS FROM THE ENGINEER'S REPRESENTATIVE AT THE SITE.
4 2
2-14mm THW 17. COVER ALL JUNCTION BOXES (STRICTLY NO EXPOSED WIRE).
+ 1-5.50mm TW(G)2
IN 25mmØ RSC 18. ALL FLUORESCENT LIGHT BALLAST SHALL BE ELECTRONIC TYPE AND LOCATED INSIDE THE METAL BOX.

13 114 0.52
7 1260 5.73

C1 C2
TOTAL CONNECTED LOAD 1,374 6.25 LEGEND & SYMBOLS - LIGHTS LEGEND & SYMBOLS - POWER
SPACE SPACE SW-1 SINGLE SWITCH POWER SERVICE ENTRANCE
COMPUTATIONS RATING OR SETTING OF SIZE
KW-HR METER
AUTOMATIC OVERCURRENT 3W LED PIN LIGHT
MAIN SERVICE ENTRANCE CONDUCTORS / MAIN FEEDER DEVICE IN CIRCUIT AHEAD OF mm2 COPPER EXIT EXIT SIGNAGE POWER PANELBOARD
C1 EQUIPMENT, CONDUIT, ETC., WIRE TRACK LIGHT
MAIN SWITCH : NOT EXCEEDING (AMPERES) CURRENT TRANSFORMER
SW-2 DOUBLE SWITCH ENCLOSED CIRCUIT BREAKER
= 114 WATTS TOTAL LOADS X DEMAND
= 0.52 AMP 15 2.0 CIRCUIT BREAKER
220 V FACTOR ( 80 %) SW-3 TRIPLE SWITCH
20 3.5 20mmØ X 3000mm LONG CIRCUIT HOMERUN
= C1 - C2 COPPER CLAD STEEL
= ( 6.25 X 0.80% ) 30 5.5 DUPLEX CONVENIENCE OUTLET, FLUSH TYPE
1,374 WATTS
= 6.25 AMP 40 5.5
220 V = 5.00 AMP
60
100
5.5
8.0
PANELBOARD B
NOTE:
USED 2 - 14.0mm^2 THW CU. WIRE AND 200 14 E3 POWER SINGLE LINE DIAGRAM
1 - 8.0mm^2 TW CU. WIRE GROUND AT 20mm Ø RSC PIPE 80
AMP 2 POLE 240 VOLTS C.B
300 22 34 SCALE: NOT TO SCALE

PROFESSIONAL PROJECT TITLE OWNER THIS DRAWING ISSUED FOR: SHEET CONTENTS SHEET NO.
AS BUILT ESTIMATE GROUND FLOOR : LIGHTING LAYOUT
ONE STOREY BIDDING FABRICIATION GROUND FLOOR : POWER LAYOUT

PRC NO.
PTR NO.
PROFESSIONAL ELECTRICAL ENGINEER

VALIDITY:
ISSUED ON:
ELECTRICAL LAY OUT PLAN GONZAGA,CLAIRE/MARY CRES O. ELECTRICAL PERMIT
CONSTRUCTION
OWNER APPROVAL
PRESENTATION
PANELBOARD LOAD SCHEDULE
PANELBOARD POWER SINGLE LINE DIAGRAM
E-01
OWNER LEGENDS
ISSUED AT: TIN: LOCATION: SITIO ,CANLANIPA,SURIGAO CITY