Diesel Generator Set
K50 Series
1000 kWe, 1250 kVA Prime
Reliable and Durable Standard Scope
Cummins ‘K50 series’ diesel engine with strong
®
Engine: Cummins® ‘K50 series’ direct injection, water
regrindable crankshaft, high strength connecting rod, cooled engine, 16 cylinder, 4 stroke, rated at 1500
low pressure fuel lines, STC (Step Timing Controls) RPM, It has the following specifications:
injectors and high volume coolant system make ‘K50 Cummins PT fuel pump
series’ generating sets, more reliable and durable. Cummins heavy duty ESTC injectors
Engines have clocked millions of hours operating in Holset turbocharger, pulse tuned exhaust manifold,
some of the world’s most demanding conditions. stainless steel exhaust flexible connections
Current engines are regularly upgraded with new Radiator or heat exchanger, coolant inhibitor
technologies for better performance and economy. Plate type lube oil cooler
The ultimate proof of superior performance and Outboard aftercoolers
reliability is the fact that Cummins® entities worldwide Full flow paper element filters - fuel, lube oil and by-
source these engines from Cummins India for their
pass
markets.
Dry type replaceable paper element air cleaner with
restriction indicator
Unmatched Warranty Flywheel housing & flywheel to suit single/ double
Cummins® ‘K50 series’ diesel engine generating sets bearing alternator
are a truly cost effective solution to long term power Holset flexible coupling for double bearing alternator
need backed by industry best, 2 years / 5000 hrs Starting motor – Electric, battery charging alternator
warranty, for the entire generating set. Cummins PowerCommand® microprocessor based
With superior experience in technology, design genset controller
capability and commitment reliability and quality we First fill lube oil and coolant
offer an unmatched 5 years or 5000 hours (including Alternator: Stamford brushless alternator
above 2 years) warranty coverage on 5 critical Seperately excited, self-regulated - Class ‘H’
components (5C) of the engine – Cylinder Head, insulation
Camshaft, Crankshaft, Cylinder Block, Connecting Rod Salient pole revolving field
against manufacturing defect Single bearing
PMG standard
Space heater & RTD & BTD’s only sensor - (without
Cummins Advantage scanner)
Special features of Cummins® ‘K50 series’ engines like Accessories:
STC (Step Timing Controls) injectors, low temperature Silencer suitably optimized to reduce noise
aftercooler, square cumbustion chamber, optimised Sturdy base rail
turbocharging and precision heavy duty camshaft make 990 ltrs. free standing fuel tank
these engines the ultimate in exceptional fuel efficiency 4 x 12 V dry, uncharged batteries with
all across the operating range. connecting leads and terminals
Single Source Power Assurance
Design, manufacture and testing of engine, alternator
and other accessories is done by Cummins Group of
companies for optimum performance and is backed by
a countrywide product support network with a single
source responsibility for the entire package.
Diesel Generator Set K50 Series Specification Sheet
Optionals Alternator Data
Engine: Oil/Coolant heater, No cool, PHE, Air starter Line-to-neutral and line-to-line AC volts
Alternator: Double bearing 3-phase AC current
Frequency
Control Panel: PC3.3- Bargraph for PC3.3 Panel with kW,
kW, kvar, power factor kVA (three phase and total)
Power factor, Frequency,Current, Voltage - Remote HMI
Engine Data
AMF control panel, Battery charger, Remote/Auto start
DC voltage
panel, Auto/ Manual synchronizing panel, Audio/Visual
Engine speed
annunciation for faults, Auxiliary output relays and remote
Lube oil pressure
annunciators
Coolant temperature/ low level
Comprehensive FAE data (where applicable)
Control panel: Other Data
PowerCommand® PC 3.3
The PowerCommand control
® Genset model data
system is an integrated Start attempts, starts, running hours, kW hours
microprocessor based generator Load profile (operating hours at % load in 5%
set control system providing increments)
voltage regulation, engine Fault history
protection, alternator protection, Data logging and fault simulation (requires InPower)
operator interface and Standard control functions
isochronous governing.
Digital Governing
AmpSentryTM – Includes integral AmpSentryTM protection,
which provides a full range of alternator protection function Integrated digital electronic isochronous governor
which are matched to the alternator provided. Temperature dynamic governing
Digital Voltage Regulation
Power Management – Control function provides battery
monitoring, testing and a smart starting control system. Integrated digital electronic voltage regulator
3-phase, 4-wire line-to-line sensing
Advanced Control Methodology – Three phase sensing,
Configurable torque matching
FET based full wave rectified voltage regulation and a PWM
AmpSentryTM AC Protection
output for stable operation with all load types.
AmpSentryTM protective relay
Communications Interface – Control comes standard
Over current and short circuit shutdown
with PCCNet and Modbus interface.
Over current warning
Service - InPower™ PC-based service tool available for Single and three phase fault regulation
detailed diagnostics, setup, data logging and fault simulation. Over and under voltage shutdown
Reliable Design – For reliable operations in harsh Over and under frequency shutdown
environment. Overload warning with alarm contact
Reverse power and reverse var shutdown
Multi-language support
Field overload
Independent of PC/ laptop for setting up Engine protection
Battery voltage monitoring, protection and testing
Operator panel features Over speed shutdown
Low oil pressure warning and shutdown
High coolant temperature warning and shutdown
Operator Panel Features – The operator panel, in addition Low coolant level warning or shutdown
to the alternator, displays the Utility/ AC Bus data. Low coolant temperature warning
Fail to start (over crank) shutdown
Fail to crank shutdown
Operator/ Display Functions
Cranking lockout
320 x 240 pixels graphic LED backlight LCD with bar Sensor failure indication
graph
Low fuel level warning or shutdown
for displaying electrical parameters
Auto, manual, start, stop, fault reset and lamp test/panel
lamp switches
Alpha-numeric display with pushbuttons
LED lamps indicating genset running, remote start, not in
auto, common shutdown, common warning, manual run
mode, auto mode and stop Paralleling Control Functions
Digital frequency synchronization and voltage matching
Isochronous kW and kvar load sharing controls
Droop kW and kvar control
Sync check
Extended paralleling (Peak Shave/Base Load)
Digital power transfer control (AMF) provides load transfer
operation in open or closed transition or soft
(ramping) transfer mode
Diesel Generator Set K50 Series Specification Sheet
Control functions
Time delay start and cool down
Real time clock for fault and event time
stamping
Exerciser clock and time of day start/stop
Data logging
Cycle cranking
Load shed/ dump as per configurable priority
Configurable inputs and outputs (4)
Remote emergency stop
Options
Auxiliary output relays and remote annunciators
Technical Data
Generator set specification
Model C1250 D5 P
Prime Power Rating kVA 1250
Output Voltage and Frequency 415 Volts, 50 Hz
Power Factor 0.8 (lag)
No. of phases 3 phase
Engine specifications
Make Cummins
Model KTA50-G27
No. of cylinders 16 ‘Vee’
Aspiration Turbocharged-Aftercooled
Bore and Stroke 159 mm x 159 mm
Displacement 50.3 ltrs
Output - Prime 1470 bhp (1097 kWm)
Fuel consumption @ 75% load with Radiator & Fan 190.8 ltr/hr
Fuel consumption @ 100% load with Radiator & Fan 251.8 ltr/hr
Total wet weight ( engine + radiator) 6824 kg
Length x Width x Height (engine) 2978 x 2080 x 1780 mm
Compression Ratio 14.9:1
Piston Speed 7.95 m/s
Governor Electronic
Lubricating oil sytem capacity 177 ltrs
Coolant capacity (engine + radiator) 440 ltrs
Combustion air intake @ 100% load (+/- 5%) 90.7 m3/min
Fan air flow across radiator 27357 ltrs/sec
Exhaust Temperature 460 oC
Alternator specifications
Make Stamford
Frame size / Model No. HCK6Z
Voltage Regulation + 0.5%
Insulation Class H
Standard Enclosure IP 23
Winding Pitch 2 / 3 Pitch
Stator Winding Double layer lap
Rotor Dynamically balanced
Total Harmonic Factor <2%(50Hz)
Rating definitions
Prime Power (PRP):
Applicable for supplying power to varying electrical load for unlimited hours. Prime Power (PRP) is in accordance with ISO 8528. Ten
percent overload capability is available in accordance with ISO 3046.
- Fuel consumption data is based on diesel having specific gravity of 0.85 and conforming to
IS:1460
- Fuel consumption tolerance is +5%
Diesel Generator Set K50 Series Specification Sheet
Typical Open Genset Dimensions
Genset Rating Length Width Height Wet Weight## Standard Fuel Tank
Model (kVA) (mm) (mm) (mm) (kg) Capacity - External
C1250 D5 P 1250 kVA 5167 2448 2963 11235 990
L W
Authorised Representative
Visit our facebook page at :
Cummins India Limited
Cummins Power Generation India Power Systems Business
Cummins India Limited
Cummins India Office Campus
“Our energy working for you.” Power Systems Business
Tower-A, 8th Floor, S. No. 21
Cummins India Office Campus
Balewadi, Pune - 411 045 (India)
Tower-A, 8th Floor, S. No. 21,
Balewadi, PuneEmail :
[email protected] – 411 045 (India)
Cummins is registered trademarks of Cummins Inc. www.cummins.com
Specifications are subject to change without notice. Email:
[email protected]PSBU/020/K50/1250/ HD/ MP/Revision-0 (05/2024) www.cumminsindia.com