0% found this document useful (0 votes)
92 views4 pages

Hyperdesmo Classic Waterproofing Membrane

HYPERDESMO® (CLASSIC VERSION) is a one-component polyurethane liquid membrane designed for waterproofing and protection, known for its ease of application and strong adhesion to various surfaces. It offers excellent mechanical, chemical, and UV resistance, with a service temperature range from -40°C to 90°C. The product is certified under multiple standards and is recommended for use on a variety of substrates, although it has limitations regarding unsound surfaces and swimming pool applications.

Uploaded by

frefi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
92 views4 pages

Hyperdesmo Classic Waterproofing Membrane

HYPERDESMO® (CLASSIC VERSION) is a one-component polyurethane liquid membrane designed for waterproofing and protection, known for its ease of application and strong adhesion to various surfaces. It offers excellent mechanical, chemical, and UV resistance, with a service temperature range from -40°C to 90°C. The product is certified under multiple standards and is recommended for use on a variety of substrates, although it has limitations regarding unsound surfaces and swimming pool applications.

Uploaded by

frefi
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

alchimica.

com

Page 1/4

HYPERDESMO®
(CLASSIC VERSION) ETA – 04/0082 18/5567

Polyurethane liquid membrane for waterproofing & protection,


easy application.

DESCRIPTION LIMITATIONS
HYPERDESMO® (CLASSIC VERSION) is the Not recommended for:
industry standard in waterproofing. For over 30 • unsound substrates (in some cases, application
years, it has provided a simple solution for is possible with the use of geotextile
waterproofing and protection. It is a one reinforcement; please contact our technical
component, low viscosity, polyurethane fluid that department for consultations).
cures with the humidity in the atmosphere to • waterproofing of swimming pool surfaces in
produce a highly elastic membrane with strong contact with chemically treated water.
adhesion to many types of surfaces.

It is based on pure elastomeric hydrophobic


When HYPERDESMO® (CLASSIC
polyurethane resin plus special inorganic fillers,
VERSION) DARK GREY or other dark colours are
which result in excellent mechanical, chemical,
used in exposed applications, a protective topcoat
thermal, UV and natural element resistance
of HYPERDESMO®-ADY-E (always pigmented at
properties.
the desired colour) or HYPERDESMO®-ADY 500
is required.
Apply with brush, roller or airless spraying in two
In order to maintain long-term solar reflectance
coats. Minimum total consumption: 1.5-1.8
and better colour protection, it is beneficial to
kg/m2.
apply the aforementioned topcoat layers even
when HYPERDESMO® (CLASSIC VERSION) is
COMPLIANCE - CERTIFICATION
applied in light colours.
• CE: ETA-04/0082.
• BBA: Agrément Certificate 18/5567
FEATURES & BENEFITS
See the table below.
• No thinning is required but SOLVENT-01 may be
• ASTM C 836/C 836M -18
used.
• Root resistance according to CEN/TS 14416
• Excellent weather and UV resistance. The white
colour reflects much of the solar energy and so
RECOMMENDED FOR
reduces the internal temperature of buildings
Waterproofing and protection of:
considerably.
• gypsum and cement boards,
• Excellent thermal resistance, the product never
• tiles (under),
turns soft. Max service temperature 90 oC, max
• bathrooms,
shock temperature 200 oC.
• roofs,
• Resistance in the cold: The film remains elastic
• light roofing made of metal or fibrous cement,
even down to -40 oC.
• asphalt membranes.
• Excellent mechanical properties.
• as the main waterproofing membrane in car
• Good chemical resistance.
park waterproofing systems.
• Non-toxic after full cure.

Certified quality, environmental and occupational health & safety management systems:
ISO 9001/14001 & ISO 45001.
HYPERDESMO®(CLASSIC version)/EE/27-01-2025
[Link]

Page 2/4

HYPERDESMO®
(CLASSIC VERSION) ETA – 04/0082 18/5567

• Water vapor transmission: The film breathes so SOLVENT-01.


there is no accumulation of humidity under the
coat. Application:
Apply the material with roller or brush in two, at
APPLICATION PREREQUISITES least, coats. Leave 6-24 hours between coats. If
Can be successfully applied on: more time passes (for example more than 4 days)
Concrete/steel reinforced concrete or otherwise, or if you are unsure of the interlayer adhesion
fibrous cement, mosaic, cement roof tiles, old please contact our technical department.
(but well adhered) acrylic and asphalt coats,
wood, corroded metal, and galvanized steel. For CONSUMPTION
information about other substrates, please contact First coat: 0.75-0.9 kg/m2.
our tech department. Second coat: 0.75-0.9 kg/m2.

Concrete substrate conditions (standard): Minimum total consumption: 1.5-1.8 kg/m2.


• Strength: C20/25.
• Humidity: W ≤ 5%. CLEANING
• Temperature: 5-35 oC. Clean tools and equipment first with paper towels
• Relative humidity: < 85%. and then using SOLVENT-01. Rollers will not be
re-usable.
Primer selection for special conditions and
substrates: PACKAGING
Please refer to the Primer Selection Table.
1 kg, 6 kg, 15 kg, 25 kg.

APPLICATION PROCEDURE SHELF LIFE


Clean the surface using a high-pressure washer, if
Can be kept for minimum 12 months in the
possible. Remove oil, grease and wax
original unopened pails in dry places and at
contaminants. Cement laitance, loose particles,
temperatures of 5-25 oC. Once a pail has been
mould release agents, cured membranes must be
opened, use as soon as possible.
removed. Fill surface irregularities with
appropriate products.
PRECAUTIONS
Contains volatile flammable solvents. Apply in
Priming:
well-ventilated, no smoking areas, away from
Apply the required primer following the guidelines
naked flames. In closed spaces use ventilators
above.
and carbon active masks. Keep in mind that
Mixing:
solvents are heavier than air so they creep on the
Use a low speed (300 rpm) mixer. May optionally
floor. The MSDS (Material Safety Data Sheet) is
be thinned with 5-10% SOLVENT-01. For
available on request.
application by spraying (airless) thin with 10%

CLASSIFICATION ACCORDING TO EOTA (EUROPEAN ORGANISATION OF TECHNICAL

Certified quality, environmental and occupational health & safety management systems:
ISO 9001/14001 & ISO 45001.
HYPERDESMO®(CLASSIC version)/EE/27-01-2025
[Link]

Page 3/4

HYPERDESMO®
(CLASSIC VERSION) ETA – 04/0082 18/5567

APPROVAL) & BBA (BRITISH BOARD OF AGRÉMENT)


HYPERDESMO® +
REQUIREMENT HYPERDESMO®
HYPERDESMO®-ADY
Minimum expected working life W3 (25 years) W2 (10 years)

Climatic zone S (Severe)

User load P1 P3
Roof slope S1-S4

Minimum surface temperature TL3 (-20 οC)

Maximum surface temperature TH4 (90 οC)

Exposure to external fire Broof (t1 - t4)

Reaction to fire Class E

TECHNICAL SPECIFICATIONS
The product in liquid form (before application):

PROPERTY UNITS METHOD SPECIFICATION

Viscosity (BROOKFIELD) cP ASTM D4287, @ 25 oC 3,000-6,000

ASTM D1475 / DIN 53217 / ISO 2811,


Specific weight gr/cm3 1.35-1.45
@ 20oC

Flash point oC ASTM D93, closed cup 35

Tack free time, @ 77 oF (25


oC) & 55% RH
hours - 4

Recoat time hours - 6-24

The cured membrane:

PROPERTY UNITS METHOD SPECIFICATION

Service temperature oC - -40 to 90

Max. temperature short time oC - 200


(shock)

Hardness Shore A ASTM D2240 / DIN 53505 / ISO R868 >60

Certified quality, environmental and occupational health & safety management systems:
ISO 9001/14001 & ISO 45001.
HYPERDESMO®(CLASSIC version)/EE/27-01-2025
[Link]

Page 4/4

HYPERDESMO®
(CLASSIC VERSION) ETA – 04/0082 18/5567

Tensile strength at break @ Kg/cm2 >60


ASTM D412 / EN-ISO-527-3
23 oC (N/mm2) (>6)

Percent elongation @ 23 oC % ASTM D412 / EN-ISO-527-3 > 500

Water vapor transmission gr/[Link] ASTM E96 (Water Method) 0.8

Kg/cm2 > 20
Adhesion to concrete ASTM D4541
(N/mm2) (> 2)
QUV Accelerated Weathering
Test (4hr UV, @ 60 oC (UVB- passed
- ASTM G53
Lamps) & 4hr COND @ 50 (2000 hours)
oC)

no significant
Hydrolysis (8% KOH, 15
- - elastomeric
days @ 50°C)
property change
no significant
Hydrolysis (H2O, 14-day
- - elastomeric
cycle RT-100 °C)
property change
no significant
Hydrolysis (H2O, 30-day
- - elastomeric
cycle 60-100 °C)
property change
no significant
HCL (PH=2, 10 days @ RT) - - elastomeric
property change
Thermal resistance (100
- EOTA TR011 passed
days @ 80 °C)

NONE OF OUR PUBLISHED INSTRUCTIONS AND SPECIFICATIONS, IN WRITING OR OTHERWISE, ARE BINDING EITHER IN GENERAL OR
WITH RESPECT TO ANY THIRD PARTY RIGHTS, OR DO THEY RELIEVE INTERESTED PARTIES OF THEIR DUTY TO SUBJECT THE PRODUCT TO
AN ADEQUATE EXAMINATION OF ITS SUITABILITY. IN NO EVENT WILL ALCHIMICA S.A. BE RESPONSIBLE FOR DAMAGES OF ANY NATURE,
WHATSOEVER, RESULTING FROM THE USE OF OR RELIANCE UPON INFORMATION OR THE PRODUCT TO WHICH INFORMATION REFERS.
ALCHIMICA S.A. RESERVES THE RIGHT TO CHANGE AT ANY TIME THE PROPERTIES OF ITS PRODUCTS. PLEASE REFER TO THE CURRENT
VERSION OF THE TECHNICAL DATA SHEET, AVAILABLE FROM OUR WEB SITE [Link]

Certified quality, environmental and occupational health & safety management systems:
ISO 9001/14001 & ISO 45001.
HYPERDESMO®(CLASSIC version)/EE/27-01-2025

You might also like