Hydraulic Profile for WWTP Components

hydraulic profile

Uploaded by

africahome21
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

2100 2100

2099 2099
02-FS +2095.45
2098 02-DC 2098
+2096.0 +2094.45
+2095.4 +2095.75 +2094.75
+2094.45 +2095.45
2097 +2095.45 +2094.45 +2094.45 2097
+2095.45
+2094.95
+2094.95
2096 +2095.55 M M
04-DC +2094.45 +2093.95 +2093.95 +2093.95
2096
+2094.6 +2093.95 +2093.2
2095 +2094.25
M
+2094.45
+2093.45 +2093.45
2095

2094 +2092.0 +2093.7 06-SWP 2094


02-GC M

2093 02-LGT 2093


+2092.05
FFL+2092.0 M
+2091.35
2092 +2091.03 02-ALP 2092
INLET +2090.50
+2090.6 07-PSP +2090.45 +2090.45 05-CSC (1,2)
2091 03-CSC (1,2) M +2090.35 2091
01-BKS +2090.100 M
M
+2090.1 +2090.1 +2090.1
+2089.6
2090 03-TK (1,2) 07-TK 04-TK
M 08-R/ E SP 2090
02-GTK 02-TK 06-TK 06-TK A
2089 05-TK (1,2) 08-TK 2089

2088 +2087.5 01-LSP 1,2,3 2088


M

2087 01-TK 2087

01-TK Pre-treatment tanks 02-TK 03-TK (1,2) 07-TK 04-TK 05-TK (1,2) 06-TK 08-TK 06-TK A
Lifting Station 02-GTK Buffer Tank Primary Clarifiers Primary Sludge Pumping Biogical Treatment Tanks Secondary Clarifiers Chlorination / Dechlorination Tanks Return /Excess Sludge Storage Tank
Volume: 43.2/(28.8) m3 Grit Removal Tanks Volume: 755/(678)m3
Dia: 6.70m Station QTY : 8 (4 each Stream) Dia: 9m Ch. Volume: 105/(92)m3 Pumping Station Volume: 617/(503.7)m3
Dim.: 3.1mX3.1mX4.5/(3)m Dim.: 8mX1.5mX4/(3.55)m Dim.: 16mX8mX5.9/(5.3)m QTY : 2 Volume: 19.2/(17.2)m3 QTY : 2 Dim.: 11mX2.5mX3.85/(3.35)m Volume: 38.8/(34.8)m3 Dim.: 16.25mX10mX3.85/(3.1)m
(L*W*H/(TWL)) (L*W*H/(TWL)) (L*W*H/(TWL)) Dim.: 2mX2mX4.8/(4.3)m Dech. Volume: 41.8/(36)m3 Dim.: 4mX2mX4.85/(4.35)m (L*W*H/(TWL))
QTY : 1 QTY : 2 QTY : 1 (L*W*H/(TWL)) Dim.: 4.35mX2.5mX3.85/(3.35)m (L*W*H/(TWL)) QTY : 1
QTY : 1 (L*W*H/(TWL)) QTY : 1
QTY : 2
01-LSP 02-LGT 02-BP 03-CSC (1,2) 07-PSTP 04-MX 1 05-CSC (1,2) 08-R/ E SP
Lifting Station Pumps Longitudional Grit Trap Balancing Pumps Clarifiers Scrapper Primary Sludge Transfer Pre-Anoxic Tank Mixers Clarifiers Scrapper Return /Excess Sludge Pumps
QTY : 3 QTY :2 QTY : 4 & Skimmer Pumps QTY : 4 QTY : 2 QTY RAS : 2 Duty + 1 standby
QTY : 2 QTY : 2 QTY SAS : 1 Duty + 1 standby

01-BKS 02-ALP 02-DC 04-MX 2 06-SWP


Manual Basket Screen Air Lifting Pumps Distribution Chamber Anaerobic Tank Mixers Service Water Pump
QTY :1 QTY :2 QTY : 1 QTY : 4 QTY : 1 set

01-OCU
Odor Control Unit 02-GC 02-MX 04-MX 3
QTY :1 Grit Classifier Buffer Tank Mixers Anoxic Tank Mixers
QTY :1 QTY : 2 QTY : 4

02-OCU 04-RCP
Odor Control Unit Sludge RC Pumps
QTY :1 QTY : 4

02-FS 04-DC Issued For Approval


Fine Screens Distribution Chamber Client: Consultant: Main Contractor:
QTY :2 QTY : 1

Acute Engineering PLC


Werabe University PO Box : 23219, Code 1000 Tilahun abebe general contractor
Ethiopia Addis Ababa, Ethiopia
02-BS 04-SA
Manual coarse Screen Aeration Tanks
QTY :1 Surface Aerators
QTY : 4 Werabe university WWTP

MENA WATER FZC


Tel.: +971-6-5575507, Fax: +971-6-5575508, P.O. Box: 120881, SAIF Zone, Sharjah, U.A.E.
E-mail: info@[Link] - Web: [Link]
2100 2100

2099 2099

2098 2098
10-SA
2097 +2094.95 +2095.1 +2096.0 +2095.1 +2096.0 +2096.0 +2094.5 +2094.5 2097
+2095.45 M M M

2096 +2093.95 2096


+2094.45
2095 2095

2094 11-BPU +2092.0


+2092.0
2094
10-MX M
+2091.5 +2093.1
2093 M +2092.2 M
2093
+2091.6 +2091.6
FFL+2092.0
2092 2092
11-STR
2091 +2090.6 M 09-TSC (1) 09-TSC (2) 13-SDB 2091
+2090.1
+2089.6
2090 07-TK M 2090
09-TK (1) 09-TK (2) 10-TK
2089 08-R/ E SP +2088.5 2089
08-TK
2088 12-DLS 2088

07-TK 09-TK (1) 08-TK 09-TK (2) 10-TK 11-STR 12-DLS 13-SDB
Primary Sludge Pumping Sludge Thickeners Return /Excess Sludge Sludge Thickeners Aerobic Sludge Digester / Sludge Treatment Room Inplant Drain Lifting Station Sludge Drying Beds
Station (Primary) Pumping Station (Secondary) Mixing Tanks QTY : 1 Volume: 14/(12) m3 QTY : 4
Volume: 19.2/(17.2)m3 Dia: 4.8m Volume: 38.8/(34.8)m3 Dia: 4.8m Volume Dig.: 472/(352)m3 Dim.: 2mX2mX3.5/(3)m
Dim.: 2mX2mX4.8/(4.3)m QTY : 1 Dim.: 4mX2mX4.85/(4.35)m QTY : 1 Dim. Dig.: 16mX5mX5.9/(4.4)m (L*W*H/(TWL))
(L*W*H/(TWL)) (L*W*H/(TWL)) Volume Mix. : 97.4 m3 (72.6 m3) QTY : 1
QTY : 1 QTY : 1 Dim. Mix.: 3.3mX5mX5.9/(4.4)m
(L*W*H/(TWL))
07-PSTP 09-TSC (1) 08-R/ E SP 09-TSC (2) QTY : 2 11-BPU
Primary Sludge Transfer Thickeners Scrappers Return /Excess Sludge Pumps Thickeners Scrappers Belt Press Unit
Pumps QTY : 1 QTY RAS : 2 Duty + 1 standby QTY : 1 QTY :1
QTY : 2 QTY SAS : 1 Duty + 1 standby

09-TSTP (1) 09-TSTP (2) 10-MX 11-DS


Thickened Sludge Thickened Sludge Mixing Tanks Mixer Dosing System
Transfer Pumps Transfer Pumps QTY : 1 QTY : 1
(Primary) (Secondary)
QTY : 1 QTY : 1
10-SA 11-SC
Aerobic Sludge Digester Screw Conveyor
Surface Aerator QTY :1
QTY : 2

11-OCU
Odor Control Unit Issued For Approval
QTY :1 Client: Consultant: Main Contractor:

Acute Engineering PLC


Werabe University PO Box : 23219, Code 1000 Tilahun abebe general contractor
Ethiopia Addis Ababa, Ethiopia

Werabe university WWTP

MENA WATER FZC


Tel.: +971-6-5575507, Fax: +971-6-5575508, P.O. Box: 120881, SAIF Zone, Sharjah, U.A.E.
E-mail: info@[Link] - Web: [Link]