0% found this document useful (0 votes)
22 views3 pages

ADSS G652D Fiber Cable Specifications

The document details the specifications of the CABLE MONOMODO ADSS G652D, including its loose tube construction, fiber color coding, and structural parameters for various fiber counts. It outlines mechanical and environmental performance metrics, such as tensile strength and temperature ranges, as well as acceptance conditions for various tests. Additionally, it provides optical fiber characteristics, including attenuation and dispersion values at different wavelengths.

Uploaded by

francisco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
22 views3 pages

ADSS G652D Fiber Cable Specifications

The document details the specifications of the CABLE MONOMODO ADSS G652D, including its loose tube construction, fiber color coding, and structural parameters for various fiber counts. It outlines mechanical and environmental performance metrics, such as tensile strength and temperature ranges, as well as acceptance conditions for various tests. Additionally, it provides optical fiber characteristics, including attenuation and dispersion values at different wavelengths.

Uploaded by

francisco
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

CABLE MONOMODO ADSS G652D (SPAN 150M 4KN )

1. Cable cross-section (only for reference)

2. Cable Description
Loose tube construction, tubes with jelly filled, elements (tubes and fillers when necessary) laid up
around non-metallic central strength member, polyester yarns used to bind the cable core, water
blocking tape wrapped, aramid yarns reinforced, 2 ripcords and then PE outer sheath.

3. Fiber color code


No. 1 2 3 4 5 6

Color Blue Orange Green Brown Gray White

No. 7 8 9 10 11 12

Color Red Black Yellow Violet Pink Aqua

4. Loose tube color code


No. 1 2 3 4 5 6

Color Blue Orange Green Brown Gray White

No. 7 8 9 10 11 12

Color Red Black Yellow Violet Pink Aqua

If there are any fillers, the color will be nature

FOINTER S.A. de C.V.


67 Ave. Norte, No.120,
San Salvador, El Salvador
Teléfonos: (503) 2536-0000
[Link]
5. Structure parameter
Item Contents Unit VALUE CORES
Fiber count Number / 06/12/2024 48 96
Cable structure / / 1+6 1+6 1+8
Fiber No. per tube Number / 6 12 12
Loose tube Number / 1/2/4 4 8
Central strength member Material / FRP with cushion when necessary
Outer sheath Thickness mm 1.5
Cable diameter ±5% mm 10 10.6 12
Cable weight ±10% kg/km 71 83 114
Weather condition / / No ice and max. wind speed 25m/s
Max. span / m 150
Installation sag / % ≥1.2
Note: Sheath thickness not consider ripcord portion, sizes and values without tolerances are nominal values

6. Mechanical & Environmental Performance


Contents Value
Max. tensile load MAT 4000N
Max. crush resistance Short term 1000 N/100mm
Installation 20 x cable diameter
Min. bending radius
Operation 10 x cable diameter
Operation -30℃ ~ +70℃
Temperature range Installation -20℃ ~ +60℃
Storage/transportation -30℃ ~ +70℃

FOINTER S.A. de C.V.


67 Ave. Norte, No.120,
San Salvador, El Salvador
Teléfonos: (503) 2536-0000
[Link]
7. Main mechanical & environmental performance test
Item Test Method Acceptance Condition
Tensile Strength - Load: MAT - Fiber strain  0.33%
IEC 60794-1-21-E1 - Length of cable: ≥ 50m - Loss change  0.1dB@1550nm after test.
- Load time: 1min - No fiber break and no sheath damage.
Crush Test - Load: Short term crush - Loss change  0.1dB@1550nm after test.
IEC 60794-1-21-E3 - Load time: 1min - No fiber break and no sheath damage.
Impact Test - Points of impact: 3 - Loss change  0.1dB@1550nm after test.
IEC 60794-1-21-E4 - Times of per point: 1 - No fiber break and no sheath damage.
- Impact energy: 4.5J
Repeated Bending - Bending radius: 20 x OD - Loss change  0.1dB@1550nm after test.
IEC 60794-1-21-E6 - No. of cycle: 25 - No fiber break and no sheath damage.
Torsion - Length: 1m - Loss change  0.1dB@1550nm after test.
IEC 60794-1-21-E7 - Twist angle: ±90° - No fiber break and no sheath damage.
- No. of cycle: 10
Cable bend - Diameter of mandrel:20 x OD - Loss change  0.1dB@1550nm after test.
IEC 60794-1-21-E11 - Number of turns:4 - No fiber break and no sheath damage.
- Number of cycles:3
Water Penetration - Height of water: 1m
- No water leak from the cable core of the opposite
IEC 60794-1-22-F5B - Sample length: 3m
end.
- Time: 24h
Temperature Cycling - Temperature: -30℃~+70℃ - Loss change  0.15dB/km @1550nm.
IEC 60794-1-22-F1 - Time of each step: 12h - No fiber break and no sheath damage.
- Number of cycles: 2
8. OPTICAL FIBER
Item Contents Value
G.652D Optical characteristics
@1310nm ≤0.36dB/km
Attenuation
@1550nm ≤0.22dB/km
@1288nm~1339nm ≤3.5ps/(nm·km)
Dispersion
@1550nm ≤18ps/(nm·km)
Zero-Dispersion wavelength 1300nm~1324nm
Zero-Dispersion slope ≤0.092ps/(nm2·km)
@1310nm 9.2±0.4μm
Mode field diameter (MFD)
@1550nm 10.4±0.5μm
Cable cutoff wavelength λcc(nm) ≤1260nm
Macro bending Attenuation @1550nm (100turns;Φ60mm) ≤0.05dB
Link polarization dispersion (PMDQ) ≤0.1ps/km1/2

FOINTER S.A. de C.V.


67 Ave. Norte, No.120,
San Salvador, El Salvador
Teléfonos: (503) 2536-0000
[Link]