CABLE MONOMODO ADSS G652D (SPAN 150M 4KN )
1. Cable cross-section (only for reference)
2. Cable Description
Loose tube construction, tubes with jelly filled, elements (tubes and fillers when necessary) laid up
around non-metallic central strength member, polyester yarns used to bind the cable core, water
blocking tape wrapped, aramid yarns reinforced, 2 ripcords and then PE outer sheath.
3. Fiber color code
No. 1 2 3 4 5 6
Color Blue Orange Green Brown Gray White
No. 7 8 9 10 11 12
Color Red Black Yellow Violet Pink Aqua
4. Loose tube color code
No. 1 2 3 4 5 6
Color Blue Orange Green Brown Gray White
No. 7 8 9 10 11 12
Color Red Black Yellow Violet Pink Aqua
If there are any fillers, the color will be nature
FOINTER S.A. de C.V.
67 Ave. Norte, No.120,
San Salvador, El Salvador
Teléfonos: (503) 2536-0000
[Link]
5. Structure parameter
Item Contents Unit VALUE CORES
Fiber count Number / 06/12/2024 48 96
Cable structure / / 1+6 1+6 1+8
Fiber No. per tube Number / 6 12 12
Loose tube Number / 1/2/4 4 8
Central strength member Material / FRP with cushion when necessary
Outer sheath Thickness mm 1.5
Cable diameter ±5% mm 10 10.6 12
Cable weight ±10% kg/km 71 83 114
Weather condition / / No ice and max. wind speed 25m/s
Max. span / m 150
Installation sag / % ≥1.2
Note: Sheath thickness not consider ripcord portion, sizes and values without tolerances are nominal values
6. Mechanical & Environmental Performance
Contents Value
Max. tensile load MAT 4000N
Max. crush resistance Short term 1000 N/100mm
Installation 20 x cable diameter
Min. bending radius
Operation 10 x cable diameter
Operation -30℃ ~ +70℃
Temperature range Installation -20℃ ~ +60℃
Storage/transportation -30℃ ~ +70℃
FOINTER S.A. de C.V.
67 Ave. Norte, No.120,
San Salvador, El Salvador
Teléfonos: (503) 2536-0000
[Link]
7. Main mechanical & environmental performance test
Item Test Method Acceptance Condition
Tensile Strength - Load: MAT - Fiber strain 0.33%
IEC 60794-1-21-E1 - Length of cable: ≥ 50m - Loss change 0.1dB@1550nm after test.
- Load time: 1min - No fiber break and no sheath damage.
Crush Test - Load: Short term crush - Loss change 0.1dB@1550nm after test.
IEC 60794-1-21-E3 - Load time: 1min - No fiber break and no sheath damage.
Impact Test - Points of impact: 3 - Loss change 0.1dB@1550nm after test.
IEC 60794-1-21-E4 - Times of per point: 1 - No fiber break and no sheath damage.
- Impact energy: 4.5J
Repeated Bending - Bending radius: 20 x OD - Loss change 0.1dB@1550nm after test.
IEC 60794-1-21-E6 - No. of cycle: 25 - No fiber break and no sheath damage.
Torsion - Length: 1m - Loss change 0.1dB@1550nm after test.
IEC 60794-1-21-E7 - Twist angle: ±90° - No fiber break and no sheath damage.
- No. of cycle: 10
Cable bend - Diameter of mandrel:20 x OD - Loss change 0.1dB@1550nm after test.
IEC 60794-1-21-E11 - Number of turns:4 - No fiber break and no sheath damage.
- Number of cycles:3
Water Penetration - Height of water: 1m
- No water leak from the cable core of the opposite
IEC 60794-1-22-F5B - Sample length: 3m
end.
- Time: 24h
Temperature Cycling - Temperature: -30℃~+70℃ - Loss change 0.15dB/km @1550nm.
IEC 60794-1-22-F1 - Time of each step: 12h - No fiber break and no sheath damage.
- Number of cycles: 2
8. OPTICAL FIBER
Item Contents Value
G.652D Optical characteristics
@1310nm ≤0.36dB/km
Attenuation
@1550nm ≤0.22dB/km
@1288nm~1339nm ≤3.5ps/(nm·km)
Dispersion
@1550nm ≤18ps/(nm·km)
Zero-Dispersion wavelength 1300nm~1324nm
Zero-Dispersion slope ≤0.092ps/(nm2·km)
@1310nm 9.2±0.4μm
Mode field diameter (MFD)
@1550nm 10.4±0.5μm
Cable cutoff wavelength λcc(nm) ≤1260nm
Macro bending Attenuation @1550nm (100turns;Φ60mm) ≤0.05dB
Link polarization dispersion (PMDQ) ≤0.1ps/km1/2
FOINTER S.A. de C.V.
67 Ave. Norte, No.120,
San Salvador, El Salvador
Teléfonos: (503) 2536-0000
[Link]