High Capacity Microfiberglass Filter Cartridges
High Capacity Microfiberglass Filter Cartridges
Duo-Fine® E Series
Filter Cartridges
Performance Specifications
Filter grades
0.2, 0.45, 1, 3, 10, 30, 50 μm Product Specifications
Recommended change-out differential pressure 1 Materials of construction
2.4 bard (35 psid) Filter media:
50 μm: Spunbonded polyester
Maximum differential pressure
All other grades: Borosilicate microfiberglass with
Polypropylene hardware
acrylic binder
4.8 bard (70 psid) @ 20°C (68°F)
Support material: Spunbonded polyester
2.8 bard (40 psid) @ 65˚C (150˚F)
Netting: Polypropylene
304 stainless steel hardware Hardware: Polypropylene or 304 stainless steel 2
5.2 bard (75 psid) @ 121°C (250°F) Sealing: Thermal bond
Sterilization Gaskets/O-rings: Silicone elastomer, nitrile,
All Duo-Fine E Series cartridges may be autoclaved for fluorocarbon elastomer,
30 minutes at 121°C (250°F) under no end load conditions. hydrocarbon rubber, FEP
Cartridges with 304 stainless steel core and end caps encapsulated silicone, expanded
may be steamed in-line at 121°C (250°F) for up to one PTFE, white nitrile, white silicone
hour. Do not reverse flow under steam conditions, damage Dimensions (nominal)
to the filter may occur. Outside Diameter: 6.6 cm (2.6 in)
Lengths: 10.2 cm (4 in), 24.8 cm (9.75 in),
25.4 cm (10 in), 49.5 cm (19.5 in),
50.8 cm (20 in), 74.3 cm (29.25 in),
1 Provided that the maximum differential pressure is not exceeded based
76.2 cm (30 in), 99.1 cm (39 in),
on temperature limits defined above. 101.6 cm (40 in)
2 304 stainless steel end caps are epoxy bonded.
Color Code Chart For Duo-Fine E Series Duo-Fine E Series filter cartridges have been
Netting Color Micron Rating extensively laboratory and field tested to determine
removal efficiencies in the most stringent of operating
Green 0.2
conditions.
Yellow 0.45
The removal rating of any filtration device will depend
White 1 on, to some extent, the conditions under which it is
Blue 3 used or tested. The test results will be influenced by
Red 10 the nature of the fluid, its viscosity, the flow rate, the
Purple 30
type of contaminant, and the temperature.
Orange 50
The ratings given represent the diameter of the largest
hard spherical particle that will pass through the filter
during standard test. Contact Pall for a complete
Particle Retention (µm) description of Pall's test procedures.
Liquid Service Gas Service
(by ASTM F-795 Test)
The DOP test measures the ability of the filter to capture
fine droplets in air or gas. The retention ratings given
Cartridge 90% >99.9% Removal
Designation Efficiency Efficiency Efficiency represent the removal efficiencies with respect to an
by DOP Test aerosol dispersion of 0.3 μm Dioctyl Phthalate (DOP)
DFN 0.2 0.2 1.0 99.999% particles.
DFN 0.45 0.45 2.0 99.998%
DFN 1 1.0 4.0 96% Typical Flow vs. Differential Pressure for Application
Sizing
DFN 3 3.0 10.0 _________
Flow rate (lpm), water at 20°C
DFN 10 10.0 18.0 _________ 0 8 15 23 30 38
_________ 3.0 0.20
DFN 30 30.0 45.0
DFN 50 50.0 75.0 _________ 2.5
0.15
2.0
1.5 0.10
1.0
0.05
0.5
0 0
2 4 6 8 10
Flow rate (gpm), water at 68°F
© Copyright 2005, 2012, Pall Corporation. Pall, , and Duo-Fine are trademarks of Pall Corporation.
® Indicates a Pall trademark registered in the USA. Filtration. Separation. [Link] is a service mark of Pall
Corporation.