Current Transformer for MultiPlus-II
\
Current Transformer 100 A
The 100 A Current Transformer can be used together with a MultiPlus -II or MultiPlus 20k to measure AC
current on an external conductor, without routing that current through the inverter charger itself. It is used
to implement PowerControl and PowerAssist, and to optimize sel f-consumption using external current
sensing. The Current Transformer allows the MultiPlus -II to determine how much power is flowing to or
from the grid and can be used where a full energy meter is not required.
Retrofit and space constrained installations
The Current Transformer clips around an existing live conductor, so no rewiring of the main supply is
required. It is useful where there is no space for a DIN rail energy meter and provides a faster and simpler
installation than a full meter.
Current Transformer 100
A with wire end Two types
Two versions are available, one with wire ends and one with a headphone jack. Current MultiPlus -II units
and MultiPlus 20k are supplied with a two -wire terminal connection. The headphone jack connection was
used in older MultiPlus -II units.
Limitations
The Current Transformer supports single -phase monitoring only and measures current, not voltage.
It is less accurate than a dedicated energy meter, especially at low currents.
The wires must not be extended or shortened, as they are calibrated for use with the current transformer.
Current Transformer 100 A or 400 A
The 100 A or 400 A Current Transformer must be used in an external transfer switch application where an
Current transformer 100 A external transfer switch replaces the internal AC transfer switches of each individual MultiPlus -II in a three-
with headphone jack phase multi -unit system. One Current Transformer is required per phase and is connected to the master
unit of that phase. For more information, refer to the External tranfer switch manual .
Note that the 400 A Current Transformer can only be used in an external transfer switch application.
Current Transformer 400 A
with wire end
Grid parallel topology with MPPT solar charge controller. External Transfer Switch topology
The MultiPlus-II or MultiPlus 20k uses data from the Current The external transfer switch replaces the internal AC transfer switch of
Transformer to optimize self-consumption and, if required, to each individual MultiPlus -II. Each MultiPlus-II phase uses data from a
prevent feed-in to the grid. In the event of a power outage, the Current Transformer to determine whether AC input is available and
MultiPlus-II continues to supply the critical loads. Features such as controls the external transfer switch accordi ngly. A separate Current
UPS functionality, AC input current limit, PowerControl, and Transformer is required for each phase. Features such as UPS functionality,
PowerAssist remain active. AC input current limit, PowerControl, and PowerAssist remain active.
Wire Current
Model Voltage Wire termination Use for
length rating
Current Transformer 100 A:50 mA 1m
Newer MultiPlus-II units and
Current Transformer 100 A:50 mA 5m Wire end
MultiPlus 20k
Current Transformer 100 A:50 mA 20 m
100 A
Current Transformer 100 A:50 mA 1m
Headphone jack Older MultiPlus -II units
Current Transformer 100 A:50 mA 5m
50 mV
Current Transformer 100 A:50 mA 20 m
MultiPlus-II units in External
Transfer switch configuration ( s99
Current Transformer 400 A:50 mA 10 m 400 A Wire end
firmware)
Connection
• The Current Transformer clips around the AC conductor .
• Pay attention to the correct direction of the Current
Transformer. The arrow on the Current Transformer must be
pointing in the direction of the MultiPlus .
• The cable connects directly to the MultiPlus -II.
• Do not shorten the cable ; it is calibrated to the current
transformer.
Connection terminal MultiPlus -II and
Newer MultiPlus -II models
MultiPlus 20k (Newer models)
• Remove the wire link .
• Connect the Current Transformer wires to the external current
sensor terminals.
• Note that the Current Transformer is polarity sensitive .
• Connect the r ed wire to the EXT terminal .
• Connect the white wire to the COM terminal. Connection socket MultiPlus -II
(Older models)
Older MultiPlus -II models
• Plug the CT headphone jack into the headphone socket .
Front view Side view
Enclosure dimensions 100 A Current Transformer
(dimensions in m m)
Victron Energy B.V. | De Paal 35 | 1351 JG Almere |The Netherlands
E-mail: sales@[Link] |[Link]