University
Basic Configuration
7302-7330/5523 operator part 1 section C
Alcatel-Lucent University Antwerp
Alcatel-Lucent University Antwerp
1
Objectives
After completing this section, youll be able to:
Describe the most important parameters in:
the XDSL profiles,
the XDSL port configuration,
the logical port (ATM / EFM) configuration
Retrieve information on and configure:
Equipment
Profiles
Ports
Table of contents
Basic configuration of the 7302 ISAM
Equipment configuration .
Port configuration
.
.
Interworking configuration
Exercises - Questions .
p. 4
p. 5
p. 16
p. 41
p. 47
Basic Configuration of the 7302 ISAM
Equipment
configuration
Equipment
ISAM Rack Shelf Boards
Port
Ports on Service Hub
Physical
QoS
Port configuration
xDSL end user ports
Interworking
How does the user communicate towards
the access node and on into the network Interworking
configuration
Via an ATM TP:
configure ATM-Ethernet interworking
Ethernet over DSL (EFM):
Configure line-Ethernet interworking
4
Logical flow
Bridgeport
ATM
xDSL
University
Equipment configuration
Alcatel-Lucent University Antwerp
Equipment configuration
The system detects presence of equipment at startup and
auto-configures a number of items.
Autoconfiguring of ISAM (no description) , Rack, shelf and NT.
Equipment configuration
Unit configuration
Equipment configuration
System, rack, shelf
Board configuration
LTs, appliques
As long as equipment is not planned, it is impossible to
configure/offer services
Configuration of boards on XD
ISAM NT I/O applique 2
ACU slot - slot 1
NT-slots - slots 2 & 3
NT I/O - applique 2
16 LT-slots - slots 4 19
LT-slot 4
LT-slot 5
LT-slot 6
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT
LT-slot 19
NT-slot 2
ACU
ACU-slot 1
PWR
Fan unit
XD physical slot numbers
LT slot number +
3
For LT-4:
Configure slot 1/1/7
(= rack 1/shelf 1/slot 7)
Configuration of boards on FD
slot 1
slot 2
LT
LT
LT
slot 4
LT
LT
LT
LT
LT
NTA
NTIO/LT
NTB/LT
LT
slot
LT
slot
12
LT
13
LT
LT
LT
LT
LT
FD physical slot numbers
fiber conduct
Fan unit
Dust filter
PWR
NT-slot - slots 9 &11
NT I/O - applique 1
16 LT-slots
- slots 1 8
- slots 12 19
LT slot number + 3
For LT-10:
Configure slot 1/1/13
(= rack 1/shelf 1/slot 13)
For LT-4:
Configure slot 1/1/4
(= rack 1/shelf 1/slot 4)
Configuration of LT and applique boards
EML USM
view
Configuration
Accept all
boards /
appliques...
EML USM
view
Board
Accept
Create
LT
configure equipment slot <rack/shelf/slot>
[no] planned-type <Board Type>
Applique
configure equipment applique <rack/shelf/slot>
[no] planned-type <Board Type>
9
Other equipment related commands
Unconfigure equipment
EML USM
view
[no] planned-type
Board
Lock or Unlock equipment
[no] unlock
Delete
Power
ON
OFF
10
Lock
Unlock
Power down equipment
[ no] power-down
Retrieval of equipment information
View the status
EML USM
view
EML USM
view
show equipment
Isam (detail)
Board
Subrack
Rack (detail)
Show
Show
Shelf (detail)
slot/applique (detail)
e.g. show equipment slot/applique 1/1/5
Verify the configuration
Info configure equipment ...
Configure>equipment> ... > info detail
11
Configuration of expansion units on a 7330 FTTN ISAM
Create the expansion module:
configure equipment shelf <rack/shelf>
planned-type <Shelf Type>
class ext-ethernet
Configure equipment slot ctrl:<rack/shelf>
planned-type <nrcd-a or nrca-a>
Configure the association between the host
shelf SFPs and the REMs:
configure equipment external-link-assign <SFP
nr> remote <rack/shelf/slot>
Plan the board:
configure equipment slot <rack/shelf/slot>
planned-type <Board Type>
12
EML USM
view
Subrack
Expansion Module
Create
Configurable use of NTIO ports
On a 7330 some NT ports are configurable
Number of configurable ports depends on HW type & NTIO card
Configurable SFP shown as
instead of
for not configurable
Uplink: port configurable as network, user or subtending port
Downlink: towards an expansion module
A system reset is needed after reconfiguring SFPs
CLI:
Configure equipment external-link-host <SFP nr.>
direction remote-lt
or
direction network
13
EML USM
view
port
SFP
Configure
Rack and shelf assignment
7 racks, 4 shelves per rack
12 remote shelves
configurable
Rack 4 / Shelf 2
14
University
Port configuration
Alcatel-Lucent University Antwerp
15
Physical configuration of ports
on Service Hub
on ASAM-CORE
Ethernet ports
xDSL user ports
Ethernet Line Termination
(NELT)
Physical port configuration
Ethernet ports on SHUB
16
Xdsl/Eth ports on ASAM-CORE
Configuration of Ethernet ports the Shub (1/2)
Physical port configuration
7302
ISAM
PSTN
24 Ethernet interfaces on Shub
4 FE/GE
6 GE (FD)
L P
T S
NT I/O
3 (4) FE/GE
2 FE/GE (FD)
NT
ASAM links
1-16 (18)
SMAS
ACU
17
Ethernet ports on SHUB
.
.
.
L P
T S
XD: 16 ports for LT = ASAM links
FD: 16 or 18 ports for LT
1 control link for ECNT-A
XD: 8 (7 for ECNT-A) ports for user links,
subtending links and network links
FD: 8 or 2 ports for user links,
subtending links and network links
Configuration of Ethernet ports on the Shub (2/2)
ASAM ports and control port are preconfigured
Uplink (network) ports are configurable
Port-type:
Network
Subtended
User
Out-band mgmt
Configuration of uplink ports on SHUB
EML USM
Board view
Port
Configure
configure interface shub port (index) <PortType> ...
18
7302 SHUB port numbering
AWS numbering
ECNT-A
ECNT-C
NANT-A
0
1
control
18
17
18
24
23
2
3
19
20
19
20
17
18
4
5
21
22
21
22
19
20
6
7
23
24
23
24
21
22
CLI
19
Show Ethernet port configuration commands
View status of interfaces on SHUB
show interface shub port (all)
show interface shub port 1
Verify configuration of interfaces
Info configure interface shub detail
all interfaces on shub:
IP interfaces,
vlan interfaces
and Ethernet (port)
To view Ethernet ports only, use filter | match after
exact:port
For port 1 only: info configure interface shub port 1
detail
20
Configuration of xDSL port
Configure xDSL physical parameters
Content
Provider
Internet
Client PC
ISAM
ASP/ISP
ANT
xDSL
LT
Eth
NT
NT
xDSL
LT
App
HTTP
Phys
HTTP
TCP connection
TCP
IP
App
IP
routing
IP
Phys
TCP
Public
IP
PPP
IP
802.3
802.3
802.3
802.3
PPP
PPPoE
802.3
VLAN
VLAN
LLC
SNAP
LLC
SNAP
Phys
Phys
PHYS
PHYS
AAL5
AAL5
ATM
ATM
PPPoE
802.3
ADSL
xDSL
21
ADSL
xDSL
Configuration of port via AWS
Administrative state
Locked or unlocked
EML USM
Board view
Transfer mode
ATM for ADSL flavor, EFM for VDSL2
ATM or EFM for SHDSL
Assign xDSL profiles:
xDSL line service profile
xDSL line spectrum profile
Port
Port
Configure
For SHDSL ports no spectrum or service profiles are used!
All parameters configured under port configure window
Operational modes of the port
ADSL flavors or VDSLx
minimum severity for alarm reporting on the port
22
Configuration of a xdsl port for CLI
. xDSL profiles
Physical port configuration
. xDSL line
Physical
Associate xDSL profiles
Operational modes
TCA thresholds
. xDSL-line interface .
. Configure xdsl profiles
*xDSL service profile
*xDSL spectrum profile
Management parameters
desired state
. Configure xdsl line
threshold for alarm reporting
. Configure xdsl-line
. QoS
CAC, scheduling and BAC
Assign QoS profiles
23
DSL ports on ASAM-CORE
interface
. configure DSL port
QoS profiles
XDSL Profiles
XDSL service profile
Rate adaption mode
ANEL
Net bitrates
L2 lower power bitrate
Latency characteristics
Templates
Profile
Create
XDSL
Spectrum
24
XDSL
Service
XDSL spectrum profile
supported modes (ADSL2, VDSL, )
noise parameters, carrier masking & RFI
bands
mode specific power & PSD parameters
Profile
Type x
xDSL line profiles: Where used ?
7302
ISAM
EBLT
Port 2
1-16
NT I/O
ASAM links
Port 1
xDSL line configuration
Service profile
Spectrum profile
Port 3
Port 4
E1LT
NT I/O
ACU
EBLT
1-16
SMAS
ASAM links
NT
Port 1
Port 2
NT
Port 3
SMAS
ACU
25
Port 4
7302
ISAM
Profiles & Templates
Profile Templates
on AWS
ANEL
Profile 1
Profile 2
Profile 3
Profile 4
Profile 5
Profile 6
Profile x
Templates
Profile
26
Profile
Type y
Profile 2
Profile 5
Profile 6
.
.
.
Create
Profile
Type x
DOWNLOAD TO NE
Profiles on ISAM
ISAM
Profile
Type z
Global set
XDSL service :
Profile 1
Profile 2
Profile u
XDSL spectrum :
Profile 1
Profile 2
Profile v
ANEL
CREATE
GLOBAL SET xxx
XDSL service :
Profile 1
Profile 8
Profile 9
...
Global set : Set 1
Set 2
Set x
Templates
XDSL spectrum :
Profile 2
Profile 4
Global Set
DOWNLOAD
GLOBAL SET xxx
Create
AWS
27
ISAM
Download
to NE
Delete
Modify
Show
xDSL line service profile
Configuration of:
Rate adaption mode
Net bitrates
L2 lower power bitrate
Latency characteristics
Interleaving
INP
Rely on erasure
detection
28
xDSL line spectrum profile: modes
Defines allowed
modes on the
port
ADSL ... VDSL2
29
Overview of the new standards
ITU-T
G.dmt = G.992.1
= current ADSL
G.dmt.bis = G.992.3
= ADSL2
G.dmt = G.992.1 = ADSL
G.dmt.bis = G.992.3 = ADSL2
better performance
loop diagnostics
improved initialization & fast start-up
power management
G.adslplus = G.992.5 = ADSL2+
More downstream bandwidth
G.adslplus = on G.992.3
= ADSL2+
READSL2 = G.992.3 annex L
= Reach Extended ADSL2
(spectrum 2.2 MHz)
up to 24 Mbps / at least 16 Mbps
READSL2 = Annex L G.992.3
Reach Extended ADSL2
30
Annex A
POTS
Some examples of new annexes: Annex I, J and M
UP
DOWN
1.1 MHz
138kHz
ISDN
Annex B
UP
120kHz
Annex I
31
DOWN
POTS
UP
UP
UP
DOWN
DOWN
All digital
Annex M
276kHz
UP
Annex J
DOWN
ADSL2+ doubles the frequency spectrum
32
Noise margins
If maximum
NM not
enabled,
default: 51dB
Used for SRA
33
DSL Line Profiles: SNR/QAM relationship
Bits/symbol
QAM
QAM-16
Signal/Noise ratio (dB)
for BER<10-7
21,8
QAM-64
27,8
QAM-256
33,8
QAM-512
36,8
10
QAM-1.024
39,9
12
QAM-4.096
45,9
14
QAM-16.384
51,9
Relation between the SNR and the max. QAM.
(QAM is linked to line rate)
To obtain a certain speed we need a min. SNR!
34
Noise margin parameters
SNR (dB)
NM (dB)
S1 = SNR for max. output power at sta
STARTUP
SNR measured at
startup (Pmax)
S1
SHOWTIME
S2 = SNR needed for startup= S0 +
TNM
S3 = SNR at startup = S2 + MANM
S3
S2
S0
6dB
MAX.
NOISE
MARGIN
(MaxNM
)
Adjust output power
TARGET
NOISE
MARGIN
(TNM)
MINIMUM NOISE MARGIN
(MinNM)
SNR needed for the configured line rate
35
!
>1: RESET
t (s)
xDSL Spectrum profile: carriers
Enable/disable carriers
Not applicable for VDSL
Upstream (in)
Max. up to carrier 64
(ISDN) (max. 276kHz)
Downstream (out)
Max. up to carrier 512
(ADSL2+) (max. 2.2Mhz)
Used carrier range
Depends on actual operating
mode
36
xDSL spectrum profile: RFI
(Hamming bands)
Define modem behavior
(PSD) for radio bands
International amateur radio
bands (HAM)
37
Band start
ETSI/ITU/ANSI
kHz
Band stop
ETSI/ITU
kHz
Band stop
ANSI
kHz
1810
2000
2000
3500
3800
4000
7000
7100
7300
10100
10150
10150
14000*
14350*
14350*
18068*
18168*
18168*
21000*
21450*
21450*
24890*
24990*
24990*
28000*
29100*
29700*
RFI details: Egress vs. ingress
Egress control notched
PSDdBm/Hz
-60
or
< -80
f1
f2
fMHz
Notched: adapt PSD mask to 80dBm/Hz for that range
Ingress control
Operator informs modem of possible disturbance level of RFI
bands
Modem could decide not to charge those frequencies too heavily
38
Port configuration via CLI
. Configure profiles
configure xdsl spectrum-profile <index>
configure xdsl service-profile <index>
DSL ports on ASAM-CORE
. Configure physical parameters of xDSL line
. Configure xDSL profiles
xDSL service profile (256)
xDSL spectrum profile (256
Assign profiles to the port:
configure xdsl line rack/shelf/slot/port
service-profile <index>
spectrum-profile <index>
. Configure xDSL line
. Configure xdsl interface
configure interface port xdsl-line:
rack/shelf/slot/port
. Configure xDSL-line
interface
39
University
Interworking configuration
Alcatel-Lucent University Antwerp
40
Configuration of interworking via AWS
AWS configures Ethernet interworking point
For xDSL: at creation of the ATM TP
For VDSL (ISAM R3.1+):
At configuration of the VDSL2 port
For Eth Line: at creation of Bridge Port
EML USM
port view
Connection
Create
ATM Termination
point
41
ATM termination point
Define
PVC values
Encapsulation type
42
Configuration of interworking via CLI (1/2)
Logical flow
configuration
Configure ATM TP
. Configure ATM TP
only in case of ADSL flavors
VPI/VCI value
AAL 5 parameters
Configure Ethernet interworking point.
. Configure Ethernet
interworking point on the
LT
Configuration of bridge port
With default parameters
No VLAN association
Only necessary in case of L2
forwarding
mode on that particular port
43
Configuration of interworking via CLI (2/3)
Configure ATM TP
Only in case of ADSL flavors
configure atm pvc <rack/shelf/slot/ port:VPI:VCI)> aal5-encaptype < >
Content
Provider
Client PC
Internet
ISAM
ASP/ISP
ANT
xDSL
LT
Eth
App
HTTP
Phys
IP
routing
IP
Phys
App
xDSL
LT
TCP connection
TCP
IP
NT
NT
HTTP
TCP
Public
IP
PPP
IP
802.3
802.3
802.3
802.3
PPP
PPPoE
802.3
VLAN
VLAN
LLC
SNAP
LLC
SNAP
Phys
Phys
PHYS
PHYS
AAL5
AAL5
ATM
ATM
PPPoE
802.3
44
ADSL
ADSL
Configuration of logical flow via CLI (3/3)
Configure Ethernet interworking point
ADSL-flavors:
configure bridge port <rack/shelf/slot/port:VPI:VCI>
VDSL / Eth Line:
configure bridge port <rack/shelf/slot/port>
x/Eth
x/Phys layer
ASAM
link
x/Eth
45
FW Engine
LT
Y
IW
EFM / Logical
user port
FW Engine
LT
x
x/Eth
PVC / Logical
user port
x/ATM/Phys. Layer
x/Eth
University
Exercises - Questions
Alcatel-Lucent University Antwerp
46
www.alcatel-lucent.com
52