Catalog Hycel 2017 1
Catalog Hycel 2017 1
Hangelsgesellschaft m.b.H.
- Catalog -
With Hycount 3 you save space, time and costs.
Hycount 3 is ideal for cost sensitive, environment conscious
HYCOUNT 3 users, open to embrace new solutions based on innovative
technology and trendsetting design.
• Hycount 3 has a footprint of an • This space-saving device has a 10 By eliminating the need of
A4 sheet of paper – probably inch high resolution touch screen transporting tons of reagents to
the smallest dimensions of its user interface that can handle long distances and using a “green”
class worldwide. motion sensing gestures - an result printing concept, Hycount 3
• Despite its ultra-compact sizing entirely new interaction experience helps saving a significant part of
Hycount 3 has a throughput of 60 with the unit. the running expenses, keeping
samples per hour*. • Hycount 3 is designed to be cost per test low and protecting
remote-supported. System check, the environment.
• Hycount 3 can process closed
or open vials. trouble shooting, software upgrade
can be carried out at the user’s site
• Hycount 3 aspirates 9.8 µL whole
at any time if internet access
blood* but processes only 2.4
is available.
µL – the smallest sample volume
ever processed by a hematology • Small reagent volumes help keep
analyzer. down the wasteful, polluting
usage of laboratory chemicals.
HYCOUNT 3
Automated 3-part
differential haematology system
Technical
specifications
Measured and calculated parameters WBC, LYM, MID, NEU, LYM%, MID%, NEU%, HGB, RBC, HCT,
MCV, RDW-CV, RDW-SD, MCH, MCHC, PLT, MPV, PCT, PDW-
SD, PDW-CV, P-LCR%, P-LC
User interface 10,1 inch 1,200 x 800 dots high resolution graphic LCD
with touch screen
Power 12 Vdc, 5 A
Hycel Handelsges.m.b.H
Awarenfeldsiedlung 1
A-2322 Zwölfaxing
Autria
www.hycel-medical.com
T+41 22 782 77 17
EXCEED IN QUALITY AND MORE
Hycount
3N
Auto Hematology Analyzer
Hycount 3N
Auto Hematology
Analyzer
All rights reserved. Specifications subject to changes without prior notice V ersion 2.0
3N
Impedance for cell counting Thermal printer, support external printer
Cyanide-free method for H G
B
Parameters Temperature
Reagent
Well-organized software allow user WBC (0-99.9×10 9 )/L
to interact with the instrument easily, Lyse(500mL) and Diluent(20L)
easy to run Q C, sample and check RBC (0-9.99×10 1 2 )/L
results, etc.
HGB (0-300.0)g/L
PLT (0-999×109)/L
Intelligent design
One press for sample analysis with
throughput of 60 sec per test.
High voltage shock and back-flush
to remove blockage, auto and manual
print is support.
Hycount3N
VET
Auto Hematology Analyzer
Hycount 3N VET
Auto Hematology
Analyzer
Allrightsreserved.Specificationssubjecttochangeswithoutpriornotice Ve r s i o n 2 .
VET
Impedance for cell counting Thermal printer, support external printer
Cyanide-free method for HGB
Parameters Temperature
Reagent
Well-organized software allow user WBC (0-99.9×10 9 )/L
to interact with the instrument easily, Lyse(500mL) and Diluent(20L)
easy to run QC, sample and check RBC (0-9.99×10 1 2 )/L
results, etc.
HGB (0-300.0)g/L
PLT (0-999×109)/L
Intelligent design
One press for sample analysis with
throughput of 60 sec per test.
High voltage shock and back-flush
to remove blockage, auto and manual
print is support.
T echnical Specification
• Principles • Display
Impedance method for RBC and PLT l 0.4 inch TFT Touch
Sc reen
counting Cyanide free reagent for
hemoglobin test • Throughput
Flow Cytometry (FCM) + Tri-angle laser scatter method 60 samples per hour
MCH, MCHC,RDW-CV, RDW-SD, PLT, MP\/, PDW, PCT, UC%, UC#, • Data Storage Capacity
ALY%, /!>J..Y# Up to 50 ,000 results including numeric and
graphical
3 histograms for WBC, RBC and
PLT • Communication
3 DIFF scattergrams and l BASO LAN port supports HL7
• Reagent
scattergram protocol
Hycount 5
WBC:s:2.0% RBC:S HGB:S • Net Weight
l .5%
l .5% PLT:s:4.0% 26.5KG
MCV:s:1.0%
F eatures
i·
•
precise.
:-·
Hycount 5 XL
HYCOUNT 5 Auto Hematology Analyzer
XL
Product
Specifications
• Detection principle: • Test
modes:
3-angle semiconductor laser scatter, flow CBC and
cytometry (WBC Diff) CBC+Diff
• Counting modes:
Impedance method
(WBC/RBC/PLT) Cyanide free Venous blood, capillary blood and pre-
(HGB) diluted
• Parameters: • Sample volume:
I
- - ••• •
I � �
�v
'
..
"
.. ,..
. . Floatin threshold Detection aperture
, ..
- -
Linearity for
WBC: 0.00-
300 X l 09/L
Linearity for
PLT: 0-3,000
X l 09/L
••••
uo
Trac
e ultra-low sample volume Multiple counting modes:
1 0 a.
• • • SI••
�·
� 6 • ' ' ; .. . (ii•• • • • • � q •
. . . '.::..·r.i- �• [i']• • · r-
i· �,�2 �r - . . . �� ..
�1[ : �-
_!§_ .: .:: :::
________ .. ..,,,.
- .IIII !l
IJ!i
20 µ L Loading up to 60 samples . , _
l�
JIII,
( ; & ( ( ' ,1 4 8 $ / , 7 < $ 1 '
6SHFILFDWLR 025(
Q
6DPSOH GLVN
7KURXJKSXW 1 0 5 VDP SOH SRVLWLRQV
&RQVWDQW 4 0 0 7 / +
3UREH DVVHPEO\ &RPSDWLEOH ZLWK SULPDU\ WXEH, VDPSOH
FXS, HWF
2 SUREHV,FHUDPLF V\ULQJH
/LTXLG OHYHO GHWHFWLRQ
,QWHUQDO EDUFRGH UHDGHU (RSWLRQDO) +<&+(04
&DOLEUDWLRQ
$ XWR GHSWK
DGMXVWP HQW /LQHDU (RQH-SRLQW, WZR-SRLQW DQG PXOWL-
SRLQW),
80
, QWHULRU DQG H[ WHULRU
SUREH Z DVK / RJ LW-/ RJ 4 3 , / RJ LW-/ RJ 5 3 , 6 SOLQH,
AƵƚŽ CŚĞŵŝƐƚƌLJ
&ROOLVLRQ SURWHFWLRQ H[ SRQHQWLDO, 3RO\QRPLDO,3DUDEROD
AŶĂůLJnjĞƌ
6DPSOH YROXPH: 2- &RQWURO
0L[HU
30XO DVVHPEO\ : HVWJDUG PXOWL-UXOH, /HY\--HQQLQJV,
5HDJHQW YROXPH: &XP XODWLYH VXP FKHFN, WZ LQ SORW
2 PL[HUV
20-400XO
1DQR-SROLVKHG 2SHUDWLRQ 8QLW
6LOHQW PL[LQJ : LQ 7 , : LQ 8
&DUU\ RYHU<0.1% ,QWHUIDFH: 1HWZRUN SRUW
: DVK VWDWLRQ : RUNLQJ &RQGLWLRQV
9-VWHS ZDVK 3 RZ HU 6 XSSO\ : 1 0 0 a 2 4 0 9 , 5 0 /6 0 + ] ,
&RQFHQWUDWHG VROXWLRQ WR DYRLG FDUU\- 11 0 0 9 $
RYHU 7HPSHUDWXUH: 1 5 a 3 0 &
: KLWH EORFN WR UHP RYH DQ\ EXEEOH +XPLGLW\: 3 5 a 8 5 %
: DWHU FRQVXPSWLRQ< 2 0 / / + : DWHU FRQVXPSWLRQ: 15//KRXU
3KRWRPHWHU 'LPHQVLRQ: 11 0 0 P P [ 8 1 0 P P [ 11 2 0 P P (:
[ ' [ +)
$ GYDQFHG J UDWLQJ WHFKQRORJ \
: HLJ KW: 3 0 0 . J
&RPSOHWH VHDOHG, PDLQWHQDQFH-IUHH
+DORJHQ-WXQJVWHQ ODPS
13
ZDYHOHQJWKV:340QP,380QP,412QP,450
QP,
510QP,546QP,570QP,605QP,670QP,7
00QP,
740QP,800QP,850QP
$EVRUEDQFH: 0- 4. 0$EV
5HDFWLRQ GLVN
5HDJHQW GLVN VHPL-SHUPDQHQW
1 2 0 SODVWLF FXYHWWHV,
XVH
9 0 UHJHQW SRVLWLRQV
6 ROLG KHDWLQJ
24-KRXU QRQ-VWRS, VWDEOH
FRROLQJ DW 3 7 0 . 1 &
R
+\FHO +DQGHOVJHVHOOVFKDIW P. E . + .
$ZDUHQIHOGVLHGOXQJ 1 ,
2 3 2 2 =Z|OID[LQJ, Austria
7HO: + 43 6 5 0 6 3 0 7 6 7 0 +WWS:
//ZZZ.K\FHO-PHGLFDO.FRP
+<&+(04
80 5REXVW
KDUGZDUH
AƵƚŽ CŚĞŵŝƐƚƌLJ 6DPSOLQJ DQG P L[LQJ P RGXOH
AŶĂůLJnjĞƌ + LJ K TXDOLW\ FHUDP LF V\ ULQJ H DQG QDQR P DWHULDO SUREH P DNH LWV
*HQHUDO DVSLUDWLRQ SUHFLVLRQ 0 . 1 XO, Z KLFK HQVXUH WURXEOH-IUHH LQ DVSLUDWLRQ RI VPDOO
IHDWXUH YROXPH VDPSOH
0DWHULDOV RI SUREH LV P DNH RI VWDLQOHVV VWHHO, HQVXUH ORQJ OLIH,
5DQGRP DFFHVV, IXOO\ DXWRPDWHG,
6 7$ 7 DOVR SUREH LQVLGH LV FRDWHG Z LWK QDQR P DWULDO IRU OHVV
0DLQWHQDQFH IUHH J UDWLQJ 0 DWHULDOV RI P L[ HU LV QDQR P DWHULDO, Z KLFK P DNH VXUH OLW
WOH
SKRWRPHWHU GURSOHW RQ WKH VXUIDFH RI P L[ HU, PLQLPL]H FDUU\ RYHU EHWZHHQ HDFK
24-KRXU QRQ-VWRS FRROLQJ V\VWHP WHVWV
(QKDQFHG OLTXLG V\VWHP
9-VWHS ZDVK ODXQGU\ V\VWHP
1 2 0 SODVWLF FXYHWWHV, VHPL- , P SRUWHG SXP S DQG YDOYH WR P DNH OHVV EUHDN-GRZ Q IRU
SHUPDQHQW XVH OLTXLG V\ VWH P
9 0 UHDJHQW SRVLWLRQV, 1 0 5 VDPSOH 9 -VWHS Z DVK WR P DNH VXUH FXYHW
WH LV FOHDQHG FRP SOHWHO\
SRVLWLRQV IRU EHWWHU SHUIRUPDQFH
6 LP SOH OLTXLG V\ VWHP GHVLJ Q IRU HQJ LQHHU HDV\ WR SHUIRUP
P DLQWHQDQFH
HYCHEM 300
Entièrement automatisé accès aléatoire, système, ouvert dégazeur intégré assure un échantillonnage précis la conception de refroidissement de l'eau sans bruit
Jusqu'à 240 T / H (Sans ISE) Laver par une solution de lavage alcaline 40 postes pour l'échantillon, compatible
Laver et système non-wash deux disponibles Entretien rotor libre avec mouvement stable avec régulière tube d'échantillon / tasse, vide,
81 cuvettes en plastique spéciaux, le quartz en option tube en plastique, etc.
24 heures du système de refroidissement de réactif lecteur de code à barres en option
40 positions réactifs et 40 positions d'échantillons
Système complet scellé spectrométrique matrice
lecteur de codes à barres et PC interne en option
A l is subject to the real objec:t if there is eorne di!ference with the model,specification or price.
HY-LYTE
300
Electrolyte Analyzer
HY-LYTE 300
Electrolyte Analyzer
CV
1.0%
1.0%
1.0%
1.5%
1.5%
0.5%
HY-PRO
C
w
HY-
PRO
Add:
H yc e l H a n d e l s g e s e l l s c h a f t m . b . H .
Aw a r e n f e l d s i e d l u n g 1 ,
2 3 2 2 Zwö lf axi ng, AU STR IA
Tel : + 43 6 5 0 6 30 7 6 7 0 http : / /w
ww.h yce l-me di ca l .com
HY-PRO Test
Volume
Parameter HS-CRP / CRP HbA1c mALB ASO RF Anti-CCP CYS-C D-Dimer
Buffer
Ingredient
Buffer 00 L 1000 L 00 L 300 L 320 L 30 L 300 L 300 L
Sample 2 L 20 L 20 L L L 10 L 10 L L
Features
Test Nephelometry
principle HS-CRP, CRP, HbA1c, mALB, ASO, RF, Anti-CCP, CYS-C, D-Dimer, etc. 3 simple steps,
Parameters Diode laser, wavelength 650 nm
Light source 1 (HY-PRO 50) or 4 (HY-RPO 54) independant 100,000 detailed sample results can be saved
Testing channels Whole blood, serum, plasma, urine, etc.
channel 2-100 L
Sample type 10-100 L
Sample volume Up to 40 (HY-PRO 50)/160 (HY-PRO 54) samples/hour
Reagent Specific antigen-antibody combination preventing non-
volume specific reaction, CV<5%
Throughput Results can be traced againest CRM470
Specificity Megnetic card with built-in standard calibration curve,
Traceability making stable and reliable result
Calibration Auto temperature control and mixing
free
Temperatur
e control
+ <-& 2 $ 54/51
6HPL-DXWR &RDJXODWLRQ
$QDO\]HU
+ <-& 2 $ 54/51
6HPL-DXWR &RDJXODWLRQ
$QDO\]HU
*HQHUDO ) HDWXUH
V
3 DUDP HWHUV: 3 7, $ 3 7 7, 7 7, ) ,%,
HWF.
3ULQFLSOH: &ORWWLQJ, RSWLFDO
PHWKRG 'LVSRVDEOH FXYHWWH, QR
FDUU\-RYHU 3UHFLVH HOHFWURQLF
SLSHWWH
7KHUPDO SULQW(HU,
/DQJXDJHV: DXWR&PDQXDO
QJOLVK, ) UHQFK, S6SDQLVK,
ULQW 3 RUWXJXHVH,
6XSSRUW
HWF. /,6
/$XWRPDWLF
HVV DQG HDV\
VWDUWP DLQWHQDQFH
DW UHDJHQW
DGGLWLRQ
S
6 SS
W/ 6
/ V D G H \
P LW
+ <-&2 $ 5
51 + <-&2 $ 54
1 WHVWLQJ FKDQQHO 4 LQGHSHQGHQW
'LVSOD\: 4.3-LQFK VFUHHQ FKDQQHOV 'LVSOD\: 5-
&XYHWWH LQFXEDWLRQ SRVLWLRQV: LQFK VFUHHQ
5 5HDJHQW LQFXEDWLRQ &XYHWWH LQFXEDWLRQ
SRVLWLRQV: 2 SRVLWLRQV: 24
6L]H: 2 9 0 P P 2 6 0 P P 1 3 5 P P 5HDJHQW LQFXEDWLRQ
1HW ZHLJKW: 2 .2 NJ SRVLWLRQV: 6
6L]H:
3 4 5 P P 3 2 5 P P 1 4 5 P P
1HW ZHLJKW: 6NJ
7HFKQLFDO 6SHFLILFDWLRQV
: DYHOHQJWK: / ( ' 4 7 0 Q P
0 H P R U \ : 1 0 , 0 0 0 UHVXOWV
VWRUDJH
,QSXW: . H\SDG
6DPSOH YROXPH: 2 0 - 4 0 ȝ /
5HDJHQW YROXPH: 2 0 - 4 0 ȝ /
(OHFWURQLF SLSHWWH: 2 0 -
200ȝ/
$ YDLODEOH GLPHQVLRQV:
6 HFRQGV, P J / G / , J / / , 8 / /
,QFXEDWLRQ WHPSHUDWXUH:
3 7 . 0 1 . 0¥ 5HODWLYH KXPLGLW\:
8 5 %
3UHFLVLRQ: 3 7, $ 3 7 7 , ) ,% 5 % ; 7 7 8 % (1 RUP DO
VDP SOH) 'HYLDWLRQ EHWZHHQ FKDQQHOV: 5 %
3RZHU VXSSO\: $ & 1 0 0 - 2 4 0 9 5 0 / 6 0 + ]
&( P DUNHG
General Manager
[email protected]
Sales Administration
[email protected]
www.hycel-medical.com