0% found this document useful (0 votes)
213 views37 pages

TelephoneCables PDF

Uploaded by

7esabat7033
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
0% found this document useful (0 votes)
213 views37 pages

TelephoneCables PDF

Uploaded by

7esabat7033
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF or read online on Scribd
S COPPER TELEPHONE CABLES a> Iso 9001 : 2008 a RIYADH CABLES GROUP OF COMPANIES DH TELEPHONE INTRODUCTION Based on HIGH TECHNOLOGY manufacturing process and the MOST-UP- TO-DATE production facilities incorporating Robot Reel Handling system and with the COMMITMENT TO HIGH QUALITY Riyadh Telephone Cables Co. started production in 1994. RIYADH TELEPHONE CABLES produces all types and sizes of Telephone Cables up to 3600 pairs in accordance with Saudi MOPTT/STC Specification as well as the following international standards. * IEC, International * VDE, Germany * NP, France * REA, US.America * BS, United Kingdom STANDARD PRODUCTS * Air-Core Telephone Cables. * Jelly-Filled Telephone Cables. * Self Supporting Aerial Telephone Cables. * Indoor PVC Telephone Cables. * Buried Service Telephone Wires. * Indoor Telephone Wires. * Jumper Wires. * Drop Wires * Pilot Cables. RZ Tee oy -1 Ty APPLICABL MAl = Coppes Wire EACTURING PR: HEAVY DRAWING DESCRIPTION + Drawn from 8 0mm to 2.6mm = Polyethylene ¥ 1) Drawn copper conductor Solid (1) Drawing. ‘Min, 0.4mm di, = Cellular 2) Annealing |¢4—) Max. 0.9mm dia, ~ Foam Skin 3) Insulating 2) Conductor is annealed continuously by electical heat 3) Conductor is insulated with Polyethylene. —Y = Two insulated conductors are twisted into Pair Twisting apairOR OR [7 Four insulated conductors are twisted into Quad Twisting 4 sar-quad. —Y = 10 paits subunit OR (Sub-Uiait OR Binding Tape [Stranding | |29 pas subunit O Intermediate Inspection v Filling Compound *Diawine-op = Binding Tape 2Filing J — ies Invemediate Inspection —_—~—_, Filling Compound Fling “Lap Tape 2) Lap Serving |<¢— “Identification Tape 5) Sheating + Black Polyethylene Final Inspection v Shipping =-_ <4 ~ 5 quads subunit, Subunits are inspected according to the specifications, specified number of subunits ae lid up Specified number of units are laid up into cable core = Cable cores axe filled with filling com- pound. = Core wrapping tape applied helically Units and cable cores are inspected accord- ing to the specifications 1) Cable cores are filled with ‘compound, 2) Filled cores are served with Lap tape lon- ‘itudinaly applied 3) Lap served cable cores are sheathed with polyethylene Finished cables are inspected finally accord ing to the specifications * The MARK means that all manufacturing processes are in tandem operation. RIYADH TELEPHONE CABLES Commitment to quality Control at all production stages as well as personnel activities. Quality control includes the following inspections and testing: * In-coming raw material Inspection. * On-line testing and control equipment *In-between process testing of subunits, units and cable cores. * Final testing equipment for low frequency and high frequency cable characteristics * Statistical records for the testing standards. 1- Specify quality target data. 2- Recognize problems. 3- Analyse 4- Identify problem solution. 5- Formulate action plan. 6- Implement action plan. 7- Check for success. 8- Set new quality target data. 9- Zero defect. Zee oy -V- Te Exe 1. Copper Conductor 2. Solid PE insulation 3. Identification tape 4, Core wrapping tape 5, Aluminium moisture batier tape (for cables over 100 pairs ) 6. Black PE sheath 7, Sheath masking Description : Plain solid annealed copper conductor, high density solid polyethylene insulated, paired, ten pairs sub-unit type, air core, polyethylene sheathed, cable cores over 100 pairs manufactured with a rmoistute baie, generally complying with Saudi Arabia MOPTT MAT 1011 (EES). Application : sub cable is used for outside plant networks, installed between manholes and cabinets, Cables up to 100 paits are connected to cabinets or distribution pillar terminal boxes, Ii suitable for twopical environmental conditions (from-10°C to + 59°C ambient ) Related Specifications 16 708-1 Dimensions and Standard Packing : RTC Cable size | Approx. | Approx. | Shipping | Drum Size Product Outer Dia, | Gross Wi. | Length | (Flange Dia) No. (No.xmm) | (mm) (Kg) | (Meter) | (mm) UCEEO 032 10x2x050 100 156 1000 800 UCEEO 012 202x050 125 2s 1000 1000 50x2x050 17 413 1000 1200 uckEO 072 | 100x2x0:50 240 81 1000 1400 UCELO 082 | 200x2x050 330 1664 1000 1800 cso 102 | 300x2x050 395 2363 1000 2000 uceLo 112 | 400x2x050 450 3005 1000 2200 Zee oy V- Te 1. Conductor Resistance : 20°C Maximum average :92 obms/Km ‘Maximum individual 96 obms/Kim 1.1 Resistance Unbalance (% ) Maximum average :0.75 Maximum individual : 2.5 Resistance unbalance shall be calculated withthe following formula R (i) =Rmax-Rain x 100 Rmax > Rin 2. Insulation Resistance ‘The Insulation resistance shall not be less than 10,000 mega ohms. ken at 20°C 2.1 Dielectric Withstand Voltage: DC voltage shall be applied for sinimum 3 seconde, Conductor to Conductor: 2000 vos. Conductor to Sereen = 5000 volts Mutual Capacitance (at 10004 200 Hz) Maximum average 442m F/Km ‘Maximum individual + 50 aFKn 4. Capacitance Unbalance (at 1000 + 200 Hz) 4.a) Pair to Pair within sub-unit: Maximum average 20pF/500 m, ‘Maximum individual : 150 pF/500 m. 4.b) Pair to Pair between adjacent subsunits or units, ‘Maximum average + 20 pF/S00 m. ‘Maximum individual: SO pF/S00 m, 4.c) Ps to Earth: ‘Maximum average : 500 pF/Km ‘Maximum individual : 2500 pP/Kma 5. Attenuation ‘The attenuation of cables at 1 KHz and MH shall not exceed the following values shen corrected 0 4 Max. average attenuation (4B/Km) AUL KHz, AUL MHz 145 26 Zee oy -V- Te Pair to P: coupling loss: ‘The measurement shall be performed on one randomly selected outer unit and 99% of pair combinations shall exceed the following values at the specified frequencies, Frequency Min. NEXT! (KHz) Limit (4B/Km ) 1 85 2 80 80 or 1000 48 6 T and Power Sums: ‘The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed the following values at the specified frequencies Frequency ‘Within Unit ( dB/Km ) (KHz) Min, NEXT ‘Min. ELFEXT : 70 ™ Rp o a o 55 38 1000 37 - Zee oy -V- Te 7 Copper Conductor 2. Cellular PE insulation 3. Identification tape 4. Core wrapping tape 5, Aluminium moisture bavier 6, Black PE sheath 47. Sheath marking Description : Plain solid annealed copper conductor, high density solid polyethylene insulated, ‘ited, fen pairs sub-unit type, air core, sereened with aluminium moisture barrier and polyethylene sheathed. compliance with Saudi Arabia MOPTT MAT 1011 (CES), Application : Air core duct cable is placed in duct and wsed for primary underground distabation network between manholes and exchanges, having a single jacket cis suitable for tropical environmental conditions (from-10 ‘C to $5 °C ambien) Related Sp ns : TEC 708-1 Zee oy -V- Te RTC Cable size | Approx. | Approx. | Shipping | Drum Size Product, Outer Dia. | Gross Wt. | Length | lange Dia) No, (No.xmm) | (mm) (Kg) | (Meter) | (mm) ACCLO 101 | 300x2x0.40 290 1460 1000 1800 ACCLO 121 | 600x2x0.40 390 2500 1000 2000 ACCLO 131 | 900%2x0.40 410 2250 600 2000 ACCLO 141 | 1200x2040 540 1550 300 1800 ACCLO 151 | 1500x2x0.40 600 1950 300 2000 ACCLO 161 | 1800x2040 655 2210 300 2000 accto 1 | 2100x2x040 700 275 300 2200 Acco 181 | 2400x2x040 750 2850 300 2200 ACCLO 102 | 300x2x0.50 350 1960 1000 1800 ACCLO 122 | 600x2x0.50 a5 2325 600 2000 ACCLO 132 | 900%2x0.50 518 10 300 1800 ACCLO 142 | 1200x2050 660 2280 300 2000 ACCLO 152 | 1500x2x050 BS 2705 300 200 ACCLO 162 | 1800x2050 800 sila 300 2200 ACCLO 104 | 300x205 45 1850 600 1800 ACCLO 126 | 600x2x065 61s 1900 300 1800 ACCLO 134 | 900x2x0.65 146 2150 300 2000 ACCLO 144 | 1200x2x 0.65 850 3550 300 2200 ACCLO 076 | 100x2 x090 360 1500 600 1600 ACCLO 106 | 300%2x0.90 59.60 212s 300 1800 Zee oy -V- Te oi AIRCOR! 1. Conductor Resistance: 20°C ‘Copper Conductor Dia. (mm) [Average 040 144 150 050 2 96 065 s4 7 090 28 30 3. Mutual Capacitance: (1000 + 200812) ‘Maximum average 42 nF/Km ‘Maximum individual : 50 nB/Km, 4. Capacitance Unbalance: (at 1000+ 200 Ha) 4a ) Pair to Earth: ‘Maximum average © 500 pFcm 1.1 Resistance Unbalance: ‘Maximum individual : 2500 pF/kea Resistance unbalance shall be calculated with the following forma R (= Buax-Rmin x 100 . . Rmax + Risin 4.b ) Pair to Pair: Copper | Max Resisance Unblancet%) ‘Max. Capacitance Unbalance (pF/S00m) Conductor Dia. (mm) [Average | Individual ‘Average | Individual 040 100 2s Within sub-unit 25 150 050 075 25 065 075 20 Between adjacent 7 ss 090 075 20 subunits & units 2. Insulation Resistancs ‘The insulation resistance shall not be less than 5000 mega obs. km. at 20°C 2.1 Dielectric Withstand Voltage [DC voltage shall be applied for minimum 3 sec 5. Attenuation: The corrected attenuation Values to 45°C shall not exceed the following valves ‘onds as given below. Copper ‘Max. Average allenuation Conductor SEE Copper ‘Min, Test Voltage (Volts de) Dia (mm) | AtIKHz | Ati MHz Conductor Dia. (mm) | Conductor to | Conductor to Conductor Seren ogo pa &s 050 14s, 26 040 1700 5000 0.65 1 185 050 2000 5000 0.90) 0.80, B33 06s 2500 10000 0.90 3500 10000 Zee oy -V- Te a 6. Cross Tall 6.a) Pair to Pair Near-End (NEXT ) coupling loss: ‘The measurement shall be performed on one randomly selected outer unit and 99% of pair ‘combinations shall exceed the following values at the specified frequencies. Frequency Min, NEXT (KHz) Limit ( dB/Km ) 1 85 2 80 80 6 1000 48 the following values at the specified frequencies. :X7) and equal level fat-end (ELFEXT) individual power sums shall exceed, Zee oy -V- Te Prey Within Unit ( dB/Km ) Min, NEXT Min, ELFEXT 1 0 ” a 6 n * 55 58 1000 37 36 1. Copper Conductor 2. Cellular PE insulation 3, Identification tape 4, Core wrapping tape 5, Aluminium moisture bartier 6. Inner sheath, black PE 7, Water swellable tape 8. Outer sheath, black PE 9, Sheath marking Description - Plain solid annealed copper conductor, high density cellular polyeth ylene insulated, paired, ten pairs sub-unit type, air core, screened with aluminium ‘moisture barrier and double polyethylene sheathed with a water swellable tape or flooding compound between the sheaths, generally complying with Saudi Arabia MOPTT MAT 1011 specification (CESE), Application ; Cellular polyethylene insulated, air core, direct buried type cable is used for primary underground distribution network between manholes and exchanges, having double polyethylene sheaths for direct buried applications. It is suitable for topical environmental conditions (from-10C to + 55 T ambient). Related Specifications : IEC 708-1 Zee oy -V- Te aT Dimensions and Standard Packin; RTC Cable size | Approx. | Approx. | Shipping | Drum Size Product, Outer Dia. | Gross We | Length | (Flange Dia) No, (No.xmm) | (mm) (Kg) | (Meter) | (mm) Acco 101 | 300x2x0.40 33.0 1585 1000 1800 Acco 121 | 600x2x0.40 32 2700 1000 2000 AccDo 131 | 900x2x0.40 sLo 2400 600 2000 AccDO 141 | 1200x2040 58.10 1610 300 1800 AccDO 151 | 1500x2x0.40 640 1880 300 1800 AccDo 161 | 1300x2x0.40 695 2310 300 2000 Acco 171 | 2100x2x0.40 140 2675 300 2200 accpo 181 | 2400x2x040 790 2960 300 2200 accpo 102 | — 300x2x0:50 390.0 2285 1000 2000 AccDo 122 | 600x2x050 sis 2470 600 2000 accpo 132 | 900x2x0.50 ol imo 300 1600 accpo 142 | 1200x2x0.50 700 2380 300 2000 AccDo 152 | 1500x2x0.50 n0 2850 300 2000 accpo 162 | 1800x2x050 840 3325 300 2200 Acco 104 | 300x2x065 485 2s 600 2000 AccDO 124 | 600x2x0.65 657) 1980 300 1800 ‘Accpo 134 | 9900x2065 788 2860 300 2000 AccDo 144 | 1200x2065 892 3670 300 2200 acco 076 | 100x2 x0.90 405 1500 600 1600 AccDo 106 | 300x2x090 os 1910 300 1800 Zee oy -V- Te Cited 1.Condu at 20 ‘Copper Max, Resistance (OhmsiKi) Conductor Dia. (mm) | Average | Individual 040 144 150 050 2 96 06s SA 37 080 28 30 1.1 Resistance Unbalance (% Resistance unbalance shall be calculated with the following formula (v =Rmax-Ruin x 100 Rmax + Ria Copper | Max Resistance Unbalance(%) Conductor Dia. (mm) [Average | Individual 040 1.00) 25 050 075 25 065 075 20 0890 075 20 2. Insulation Resistance: ‘he insulation resistance shall not be es than 5000 mega hm, km. a 20% 2.1 Dielectric Withstand Voltage: 3. Mutual Capacitance (at 1000 + 200H%2) Maximum average 44:2 nF/Km Maximum individual: 50 nF/Km, 4, Capacitance Unbalance: (at 1000 + 200 Hz) 4.a) Pair to Earth: 500 pF 2500 pm Maximum average ‘Maximum individual 4. ) Pair to Pais Max. Capacitance Ui Within a sub-unit Between adjacent 1” ‘units or sub-units 5. Attenuation: ‘The comected atenuation Values to 45°C shall not exceed the following values, Max. Average avtensation Copper [DC voltage shall be applied for minimum 3 see- | Conductor (IK Dia (mm) | ACIKRR | APTN nds as given blow Cor Min. Test Voltage (Volts de) 040 1.81 265 Condictor 050 14s 26 Dia. (nm) | Condictorw | Cendctorto oss un 185 Conductor | Screen 090 080 13 040 1700 000 050 2000 5000 065 2500 10000 030 3500 10000 RIYADH TELEPHONE CABLES 13 6. Cross Talk: ‘The measurement shall be performed on one randomly selected outer unit and 99% of pair combinations shall exceed the following values 6.b) NEXT and ELFEXT Individual Power Sums: Frequency Min, NEXT (Kitz) Limit (d18/Km ) 1 85 n 80 x0 0 1000 8 ‘The near-end (NEXT) and equal evel far-end (ELFEXT) individual power sums shall exceed the following values at the specified frequencies Freguney Within Unit (B/Kin ) Min, NEXT Min, ELFEXT 1 70 ™ 2 or 1 0 ss a 1000 0 - Zee oy -V- Te rr 1, Copper Conductor 2. Insulation (Foam - skin ) 3. Filling compound(jelly) 4. Identification tape 5. Core wrapping tape 6, Aluminium moisture barrier 7. Outer sheath, black PE 8. Sheath marking Description : Plain solid annealed copper conductor, high density polyethylene foam skin insulated, paired, ten pairs sub-unit type, jelly filled, screened and black polyethylene sheathed, duct type primary and secondary local telephone cable, generally complying with Saudi Arabia MOPTT MAT 1101 specification (CEP). Application : Polyethylene insulated water proof (jelly filled) CEF type cables are used for primary and secondary underground distribution networks, (i.., in the secon- dary network between cross-connection cabinets and the subscribers connections, in the primary network between the exchange and cross-connection cabinets). CEF pro- duced for duct installation with a single black polyethylene sheath. It is suitable for tropical environmental conditions ( from- 10°C to + 55 °C ambient) Related Specifications : IEC 70: Zee oy -V- Te Dimensions and Standard eae RTC Cable size | Approx. | Approx. | Shipping | Drum Size Product, Outer Dia, | Gross We | Length | (Flange Dia) No, (No.xmm) | (mm) (Kg) | (Meter) | (mm) FCKLO 041 20x2x040 110 202 1000 800 FCKLO 061 50x2x0.40 150 369 1000 1000 FCKLO 071 | 100x2x040 195 44 1000 1200 FCKLO 091 | 200x2x0.40 260 1214 1000 1600 FCKLO 101 | 300x2x040 310 1602 1000 1600 FCKLO 121 | 600x2x040 20 1879 600 1800 FCKLO 131 | 900x2x040 sho 27 600 2000 FCKLO 141 | 1200x2x0.40 sas 1330 300 1800 FCKLO 151. | 1500x2x0.40 655 2315 300 2000 FCKLO 161 | 1800x2x040 as 2662. 300 2000 FCKLO 032 10x 2x050 100 174 1000 800 FCKLO 042 202x050 25 280 1000 1000 FCKLO 062 50x2x050 175 si0 1000 1200 FCKLO 072 | 100x2x0.50 2s 908 1000 1400 FCKLO 092 | — 200x2x0.50 ais 1730 1000 1800 FCKLO 102 | 300x2x0.50 380 167 600 1600 FCKLO 122 | 600x2x0.50 325 2816 600 2000 FCKLO 132 | 9900x2050 630 2030 300 1800 ‘cKLO 142 | 1200x2%0.50 ms 20 300 2000 FCKLO 044 20x2x0.65 150 313 1000 1000 FCKLO 06¢ 50x2x 0.65 15 800 1000 1400 FCKLO 074 | 100x2x0.65 295 1 600 1400 FCKLO 094 | 200x2x0.65 405 1593 600 1600 FCKLO 10¢ | 3090x2065 480 2409 600 2000 FCKLO 126 | 6090x2065 610 2368 300 2000 ‘CKLO 046 20x2x090 195 3m 600 1000 FCKLO 066 50x2x090 290 816 600 1400 FCKLO 076 | 100%2x0.90 395 sai 600 1600 FCKLO 096 | 200%2x0.90 sto 1870 300 1600 FCKLO 106 | 300x2x090 650 2m 300 2000 Zee oy -V- Te nductor Resistance: at 20°C Copper Max Resistance (Obna/Kim) Conductor Dia (am) [Average | Individual 0.40 144 150 050 92 96 0.65 54 37 0.90 2 30 1.1 Resistance Unbalance (%): Resistance unbalance shall be ealeulated with the following formula R (%) =Rmax-Rmin x 109 3. Mutual Capacitance: {at 1000 = 200112) ‘Maximum average aK ‘Maximum individual : SO nF/K, 4. Capacitance Unbalance: (at 1000 + 200 Hz) 4.a) Pair to Farth: Maximum average 500 pcm ‘Maximum individual : 2500 pk 4.b ) Pair to Pais max +Rmin fax. Capacitance Unbalance (pF/500m) Copper Max, Resintance Unbelancel®) “Average | Individual Condictor Dia (am) [Average | Individual ‘Within a sub-unit 2s 150 0.40 1.00 25 ooo bos Bs Saal ” 35 0.65 075 20 suns oF sub units 0.90 07s 20 2. Insulation Resistance: ‘The insulation resistance shall not he less than 2500 mege ohm. km, at 20°C 2.1 Diclect thstand Voltage DC voltage shal be applied for minimum 3 sec fonds as given below. Copper ‘Min. Test Voltage (Volts de) Conductor Dia. (am) [ Conductor to | Conductor to Conductor Screen 0.40 2400 5000 0.50 2400 000 06s 3000 10000 030, 3600 10000 5. Attenuation The corrected atfenation values to 45°C shall not exceed the following values. Copper Max, Average attenuation Conductor (aB/Kmn) Dia. (mm) | AtKHe ‘ACMHz 0.40 181 253 050 145 210 065 110. 163 0.90 0.30 136 Zee oy -V- Te me 6. Cross Talk: 6.a) Pair to Pair Near-End (NEXT. coupling loss: ‘The measurement shall be performed on one randomly selected outer unit and 99% of pair combinations shall exceed the following values at the specified frequencies. Frequency Min, NEXT (KHz) Limit (4B/Km 1 85 2 80 80 a 1000 48 ‘The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed the following values at the specified frequencies Zee oy -V- Te Fregueey Within Unit (dB/Km ) . Min. NEXT Min, ELFEXT ' 0 " 2 1 1 so 55 58 1000 a xu PAO LOTTO 10 9 8 76543 2 1 1. Copper Conductor 2. Insulation (Foam - skin ) 3. Filling compound(jelly) 4, Identification tape 5. Core wrapping tape 6. Aluminium moisture barrier 7. Inner sheath, black PE 8. Water swellable tape 9. Outer sheath, black PE, 10, Sheath marking Description : Plain solid annealed copper conductor, high density polyethylene foam skin insulated, paired, ten pairs sub-unit type, jelly filled, screened with alumin- ium moisture barrier and double black polyethylene sheathed, with water swellable tape or flooding compound between the inner and outer sheaths, direct buried type, pri- mary and secondary local telephone cable, (CEFE) generally complying with Saudi Arabia MOPTT MAT 1101 specification Application : Polyethylene insulated water proof (jelly filled) CEFE type cables are used for primary and secondary underground distribution networks, (i.¢., in the sec- ondary network between cross-comnection cabinets and the subscribers connections, in the primary network between the exchange and cross-connection cabinets). CEFE pro- duced for direct buried installation with double black PE sheath itis suitable for tropi- cal environmental conditions ( from- 10°C to + 55 °C ambient) Related Specifications : IEC 70! RIYADH TELEPHONE CABLES JELLY FILLED CABLE DIRECT BURIED TYP! Dimensions and Standard Packin; RTC Cable size] Approx. ] Approx. | Shipping | Drum Size Product Outer Dia, | Gross Wi. | Length | (Flange Dia) No. (No.xmm) | (mm) | (KG) | (Meter) | (mm) FCKDO 041 20x2x040 14s 300 1000 1000 FCKDO 061 50x2x040 Iss 500 1000, 1200 FCKDO 071 | 100x2x0.40 230 sil 1000, 1400 FcKDO 091 | 200x2x0.40 300) 1440 1000 1800 FCKDO 101 | 300x2x040 34s 1985 1000, 2000 FKDO 121 | 6002x040 460 2160 600 2000 FCKDO 131 | 900x2x0.40 550 2073 600 2200 FCKDO 141 | 1200x2x040 20 1908 300 1800 FCKDO 151 | 1500x2x0.40 69.0 2413 300 2000 FCKDO 161 | 1800x2040 750 2870 300 2200 FCKDO 032 10x2x050 Bs 269 1000 1000 FCKDO 042 202x050 1690 348 1000 1000 FCKDO 052 50x2x050 210 653 1000 1400 FeKDo 072, | 1002x050 210 16 1000 1600 FCKDO 092 | 200x2.x050 350 2020 1000 2000 FCKDO 102 | 300x2x0.50 41s 1615 600 1800 FCKDO 122 | 600x200 560 3033 600 2200 FCKDO 132 | 900x200 665 2s 300 2000 FcKDO 142 | 1200x2050 760 2930 300 2200 FCKDO 044 202x065 iss. 506 1000, 1200 FCKDO 054 50x2x065 250 1008 1000, 1600 FCKDO 074 | 100x2.x0.65 330 1087 600 1600 FCKDO 094 | 200x2.x0.65 440 1794 600 1800 FCKDO 104 | 300x2x0.65 51s 2553 600 2000 FCKDO 124 | 600x2.x0.65 0S 2467 300 2000 FCKDO 046 202x090 230 489 600 1200 FCKDO 056 50x2x080 325 1005 600 1600 FcKDO 076 | 1002x090 430 1739 600 1800 FCKDO 086 | 1502x090 505 600 2000 FCKDO 096 | 2002x090 51s 1670 300 1800 FCKDO 105 | 300x200 100 24 300 2000 Zee oy -V- Te 1. Conductor Resistance at 20°C Copper ‘Max Resistance (Obns/Km) Condictor Dia. (mm) [Average | Individual 0.40 14 150 0.50 92 96 0.65 54 37 0.90 28 30 1.1 Resistance Unbalance(%): Resistance unbalance shall be calculated with the following formula R (%) =Rmax-Rmin x 100 imax +Rmin Copper Max. Resistance Usblanc() Condictor Dia (mm) [Average | Individual 0.40 1.00 25 0.50 075 25 0.65 075 20 0.90 07s 20 2. Insulation Resistance: ‘The insulation resistance shall not be less than 2500 megs ohm. km, at 20°C 24 Dielectric stand Voltage: DC voltage shall be applied for minimum 3 seo ionds as given below. Copper ‘Min, Test Voliage (Volts de) Conductor Dia. (mm) | Conductorto | Conductor to Conductor Sereen 040 2400 5000 050 2400 5000 065 3000 10000 0.90) 3600 10000 3. Mutual Capacitance: {at 1000 + 200TK2) Maximum average 44% 2 aF/Km ‘Maximum individual 50 nF 7K, 4. Capacitance Unbalance: (at 1000 + 200 Hz) 4a) Pair to Earth: 500 pF ‘Maximum individual : 2500 pF/km Maximum average 4.b ) Pair to Pair: ‘Max. Capacitance Unbalance (pF/500m) ‘Average | Individual ‘Within sub-unit 2s 150 Between adjacent ” 5s “units or sub-units ttenuation: ; ‘The corrected attenuation values to 45 C shall not ex- ceed the following values. Copper ‘Max, Average atenuation Condicioe (aB/Km) Dia. (mm) | AUIKHz | AUIMHz 040 181 257 050 14s 210 065 110 163 0.90 0.30 B6 Zee oy -V- Te 6. Cross Talk: 6.a) Pair to Pair Near-End (NEXT ) coupling loss: ‘The measurement shall be performed on one randomly selected outer unit and 99% of pair combinations shall exceed the following values at the specified frequencies. Frequency Min, NEXT (Kuz) Limit (aB/Km) 1 85 2 %0 %0 a 1000 6 6.b) NEXT and ELFEXT Individual Power Sum: ‘The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed the following values atthe specified frequencies. Frequency Within Unit (4B/Km ) oe) Min, NEXT Min ELFEXT 1 7 ™ 2 o n % 8 ss 1000 30 46 Zee oy -V- Te L SELF TING AERIAL 8 7 54 3 20 21 1, Copper Conductor 2. Solid PE Insulation 3. Identification tape 4, Core Wrapping tape 5, Aluminium moisture barrier 6, Stranded Support Messenger 7. Polyethylene black sheath (galvanized steel wires ) 8. Sheath marking Description : Plain solid annealed copper conductor, high density solid polyethy- lene insulated, paired, ten pairs sub-unit type, aluminium moisture barrier screened, black polyethylene sheathed self supporting aerial cables (EEMS) generally comply- ing with Saudi Arabia MOPTT MAT - 1201 specification. Application : EEMS self supporting aerial cable is used in the telecommunication network, particularly in local networks on poles and walls. Related Specifications 708-1 Zee oy -V- Te Dimensions and Standard Packin; pire, ] cose | pamees, | Be S| nan ads eat ame No. (No. x mm ) (mm) (mm) (mm) | (Kg) | (Meter) | (mm) Serta] eoeeees (eee (mer eee (ero es sesto os] wox2xas0)9sxssxsio] 118 | 20428]502| 100 | 200 Zee oy -V- Te i 1. Conductor Resistance at 20°C Copper ‘Max, Resistance (Ohms/K) Conductor Dia. (mm) [Average | Individual oo 144 150 030 2 96 065, 54 7 090 28 30 L Resistance unbalance shall be calculated with the following formula 3. Mutual Capacitance: {at 1000 + 200F%2) ‘Maximum average 4422 oP /Km ‘Maximum individual 50 nF/Km, 4, Capacitance (at 1000 + 200 Hz) 4.a) Pair to Karth: Maximum average 500 pF/km Unbalance: R() =Rmax-Rmin x 109 Maximum individval : 2500 pm max + Rin Copper | Max Resistance Unbalnce(®) | 4.b ) Pair to Pair: Conductor Dia. (mm) [Average | Individual 040 Ma og ‘Max. Capacitance Unbalance (pF/500m) os ons & ‘Average | Individual 065 075 20 on on 20 ‘Within a sub-unit n 150 2. Insulation Resistance: Between adjacent 2» 50 ‘The instlation resistance shall not be less than ay 10000 mega ohms. ka, at 20°C 24 Dielectric Withstand Voltage: DC voltage shall be applied for minimum 3 sec 5. Attenuation: ‘The corrected attenuation values to 45°C shall not exceed the following values. onds as given below. Each insulated conductor — iS shall be able to withstand 220 V. de. for one mnie (aB/Km) minute Dia. (mm) | ACIKAz | AUIME Copper Min Test Volage (Vis d) 040 a a armed oso 1st 42 Dia (mm) [ Conductor to | Conductor to oe a ae Conductor Screen 0.90 os 143 040 1700 5000 050 2000 5000 065 2500 10000 090 3500 10000 Zee oy -V- Te 6. Cross Talk: 6.a) Pair to Pair Near-End (NEXT ) coupling loss: ‘The measurement shall be performed on one randomly selected outer unit and 99% of pair combinations shall exceed the following values at the specified frequencies Frequency ‘Min. NEXT, (KHz) Limit ( 4B/Km ) 1 85 2 80 80 a 1000 48 6.b) NEXT and ELFEXT Individual Power Sums: ‘The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed the following values at the specified frequencies Frequency ‘Within Unit (dB/Km ) cM) Min, NEXT ‘Min, ELFEXT 1 70 “ rey 6 n 80 55 38 1000 7 36 Zee oy -V- Te BURIED SERV i 6 5 43 2 1 1, Copper Conductor 2. High density PE Insulation 3. PVC inner sheath 4. Identification Tape. 5. Aluminium moisture barrier 6. Outer Sheath, PE black Description : Plain solid annealed copper conductor, high density solid poly- ethylene insulated, quad form, air core, PVC inner sheathed moisture barrier aluminium screen and low density polyethylene outer sheathed buried service wire (BSW) complying with MOPTT MAT - 1301 specification. Application : Buried service wire is used for direct buried installation in the outside plant network between distribution points and subscribers terminal boxes. Dimensions and Standard Packing: RTC cablesize | Approx. | Approx. | Shipping | Drm Suze Product Outer Dia. | Gross We. | Length | (Flange Dia) No. (No.xmm) | (mm) | (Kg) | (Meter) | (mm) BCEMO 022 | 1X4x050 83 110 1000 600 Zee oy -V- Te rea 1. Conductor Resistance: 3. Mutual Capacitance: {at 1000 +200 Hz) sge 92 ohms/Km ‘Maximum average 44+ 2 nF/Km ‘Maximum individual : 96 obms/Kin ‘Maximum individual. 50 nF/Kin 1.1 Resistance Unbalance (%): 4. Capacitance Unbalance: (at 1000 + 200 Hz) Maximum average 075 Maximum individual 2.5 Resistance unbalance shall be calculated with the following formula 4.a) Pair to Pair: ‘Maximum average ‘500 pF/km_ AR (%) =Rmax-Rmin Xx 100 Maximum individual :2500 pF/km. 5, Attenuation: ‘The attenuation of cables at 1 KHz and 1 MHz shall not exceed the following values when cor: less than 10,000 mega of km at 20% rected 10 45°C 2.1 Dielectric Withstand Voltage: “The insulation resistance shall not be DC voltage shall be applied for minimum 3 sec- ond. Conducta to Conductor: 3000 Valts Conducta to Screen: 10000 vols Each con inctor shall be able o withstand a po- tential 250V de, for 1 minute Maximum average attenuation dB/Km 1 KHz 1 MHz 145 22.6 RIYADH TELEPHONE CABLES G DROP WIR! PRODUCT CODE :DSEO. 1. Copper coated Steel Wire 2. High density polyethylene Insulation Description : Hard drawn copper coated steel parallel laid conductors, high density solid polyethylene insulated telephone drop wire complying’ with MOPTT MAT- 1311 Application : Drop wires are used for outdoor connections between distribu- tion points and subscribers premises. ensions and Standard Packing: RTC Cable size | Approx. | Approx. | Shipping ] Coil Size Product, Outer Dia. | Gross We. | Length | (odfid/width) No. (No.xmm) | (mm) (Kg) | (Meter) | (mm) DSEO 015 2x0.80 60x30 50 250 [282x150 x100| Zee oy -V- Te DROP WIRE ELECTRICAL AND TRANSMISSION CHARACTERISTICS 1 Conductor Resistance: at 20°C Maximum average: 88 obms/Km Maximum individval: 92 obms/Kim 1.1 Resistance Unbalance (%): Maximum average: 10 Maximum individual 3.6 Resistance unbalance shall be calculated with the following formula 2, Insulation Resistance: The insulation resistance shall not be less than 500 mega obm km at 20°C 2.1 Dielectric Withstand Voltage: DC voltage shall be applied for minimum 60 seconds Conductor to Conductor: 1500 Volts 3. Insulation Integrity between ‘h conductor t rt To withstand 1Sky ac. for five minutes. 4. Mutual Capacitance: (at 1000 + 200 Hz) ‘Maximum average 40 n5/KM Zee oy -V- Te RDANT INDOOR TELEPHONE CABLE 6 4 3 2 1 1. Copper Conductor 2. PVC Insulation 3. Identification Tape 4, Core Wrapping Tape 5. Sheath Rip Cord 6, Halogen free Flame Retardant Grey coloured sheath. Description : Plain solid annealed copper conductor, PVC insulated,paired ten pairs sub-unit type, air core , flame retardant halogen free polymer sheathed indoor telephone cable with rip cord (VRB) complying with MOPTT MAT-1401 specification Application ; VRB Indoor Cable is used for indoor installation in the tele- communication network. Dimensions and Standard Packing: RTC Cable size | Approx. | Approx. | Shipping | Drum Size Product, Outer Dia. | Gross We | Length | (Flange Dia) No. (No.xmm) | (mm) | (Kg) | (Meter) | (mm) IcvHo 032 | 10x2x050 85 157 1000 800 Icvnoo42 | 20x2x050 | 1s 233 1000 800 IcvHo 052 | 30x2x050 | 135 342 1000 1000 IcvHo0s2 | 50x2x0.50 170 533, 1000 1200 IcvHo 072 | 100x2x050 | 23.0 936 1000 1400 IcvHO 082 | 150x2x050 | 275 1374 1000 1600 ICVHO 092 | 200x2x050 | 315 1406 1000 1600 IcvHO 102 | 300x2x050 | 380 2585 1000 2000 RIYADH TELEPHONE CABLES 1, Conductor Resistance: at 20°C ‘Maximum average: 92 ohms/Km ‘Maximum individual : 96 ohms/Kmn 1.1 Resistance Unbalance (%): ‘Maximum average 0.75 Maximum individual 2.5 Resistance unbalance shall be ealeulsted with the following formula (go) =Rmax-Rmin x 100 max + Rin 2. Insulation Resistan “The insulation resistance shall not be less than $00 mega ohm km at 20°C 2.1 Dielectric Withstand Voltag DC voltage shall be applied for minimum 60 seconds ‘Conductor to Conductor: 1500 Volts 3. Mutual Capacitance: ‘at 1000 — 200 Hz) Maximum average: 75-2 nF/Km. ‘Maximum individual: 90 nF/Km 4. Capacitance Unbalance: (at 1000 + 200 Hz) Pair to Pair within a sub-unit: ‘Maximum average: 22 pF/S00m ‘Maximum individual :150 pF500m. 4.b) Pair to Pair between adjacent sub-units or units: ‘Maximum average = 20 p/500m ‘Maximum individual: 50 pF/S00m, RIYADH TELEPHONE CABLES JUMPER WIRE PRODUCT CoD! 1. Copper Conductor 2.. PVC or high density polyethylene Insulation 3. Transparent Nylon Sheath Description : Plain solid annealed copper conductor, PVC or high density polythylene insulated, single pair, and nylon jacketed jumper telephone wire complying with MOPTT MAT 1501 specification types OP-CAB and CO - AX2 Application : The polyethylene insulated jumper wires are generally used in ‘outdoor cabinets for cross connection between primary and secondary terminal block. The PVC insulated jumper wires are used in main distribution frames in exchangebuildings. Dimensions and Standard Packing: RTC able | Cable size | Approx. | Approx. | Shipping Coil Size Product. | ‘Type OvierDia.| Gross We] Length | (odiawicth) No. (Noxmm)| (am) | (ke) | (Meter) (mm) scwo 013 J op-can | 1x2x060 | 25 41 | 500 | 250x 150x100 sceno 013 | co-ax2 | 1x2x060 | 20 34 | s00 | 220% 150% 100 Zee oy -V- Te juctor Resistance: at 20 Maximum average = 62 obms/Km ‘Maximum individual : 66 ohms/Kin 2. Resistance Unbalance (%): ‘Maximum average 0.75 Maximum individual 2.0 Resistance unbalance shall be calculated withthe following formula R(%) =Rmax-Rmin x 109 Rmax+ Rmin Zee oy -V- Te 3. Insulation Resistance: The insulation resistance for PVC shall not be less than 5000 mega olin kam and for polyethy= lene insulation shall not be less than 10,000 ‘mega ohm km. at 20°C 4. Dielectric Withstand Voltage: DC voltage shall be applied for ‘minimum 60 seconds Conductor ta Conductor: 1500 Volts OT 1, Copper Conductor 2, PVC Sheath (Flame Retardant) light grey. Type-B 1. Copper Conductor 2. PVC Insulation 3. PVC Sheath (Flame Retardant) light grey. Description: Two types of Indoor Telephone Wire complying to MOPTT, MAT-1411 ‘Type A. : Plain solid annealed one pair parallel copper conductors, flame re- tardant PVC sheathed indoor telephone wire. Type B : Plain solid annealed copper conductor PVC insulated, quad form, flame retardent PVC sheathed indoor telephone wire. Application ; The Indoor Wires are used for installation between internal distribution points on subscribers termination blocks to the wall mounted tele- phone sockets. Dimension & Standard Packing: RTC Cable size Approx. | Approx. | Shipping Coll Size Product OuerDa | Gross Wt | Length | (odsidiwidthy No. (No.xmm) | (omy _| (Key | (Meter) (om) RcHo 014 | A-2x065 | sox1a | 225 250. | 186x 150x100 RcvHo 02 | B-1x4x065 | 62 123 250 | 36x 150x135 RIYADH TELEPHONE CABLES 1, Conductor Resistance: 2. Insulation Resistance: at 20 54 ohme/Kmn ‘The insulation resistance shall not be Maximum average Maximum individual : 57 ohms/Km less than 500 mega ohm km, at 20 °C Jectric Withstand Voltage: 1.1 Resistance Unbalance (%) Conductor to Conductor: 1500 V. de. Maximum average 13, or a minimum 60 second, Maximum individual 3.6 Resistance unbalance shall be calculated withthe following formula R(%) =Rmax=Rmin x 100 Remax + Rin 3. Mutual Capacitance (at 1000 + 200 Hz) ‘Type A: 100 £5 nFykm ‘Type Be 75 45 nF/em Zee oy -V- Te Ged

You might also like