COPPER TELEPHONE CABLES
a>
Iso 9001 : 2008
a
RIYADH CABLES GROUP OF COMPANIESDH TELEPHONE
INTRODUCTION
Based on HIGH TECHNOLOGY manufacturing process and the MOST-UP-
TO-DATE production facilities incorporating Robot Reel Handling system
and with the COMMITMENT TO HIGH QUALITY Riyadh Telephone
Cables Co. started production in 1994.
RIYADH TELEPHONE CABLES produces all types and sizes of Telephone
Cables up to 3600 pairs in accordance with Saudi MOPTT/STC Specification
as well as the following international standards.
* IEC, International
* VDE, Germany
* NP, France
* REA, US.America
* BS, United Kingdom
STANDARD PRODUCTS
* Air-Core Telephone Cables.
* Jelly-Filled Telephone Cables.
* Self Supporting Aerial Telephone Cables.
* Indoor PVC Telephone Cables.
* Buried Service Telephone Wires.
* Indoor Telephone Wires.
* Jumper Wires.
* Drop Wires
* Pilot Cables.
RZ Tee oy -1 TyAPPLICABL
MAl
= Coppes Wire
EACTURING PR:
HEAVY DRAWING
DESCRIPTION
+ Drawn from 8 0mm to 2.6mm
= Polyethylene ¥ 1) Drawn copper conductor
Solid (1) Drawing. ‘Min, 0.4mm di,
= Cellular 2) Annealing |¢4—) Max. 0.9mm dia,
~ Foam Skin 3) Insulating 2) Conductor is annealed
continuously by electical heat
3) Conductor is insulated with
Polyethylene.
—Y = Two insulated conductors are twisted into
Pair Twisting apairOR
OR [7 Four insulated conductors are twisted into
Quad Twisting 4 sar-quad.
—Y
= 10 paits subunit OR
(Sub-Uiait OR
Binding Tape [Stranding | |29 pas subunit O
Intermediate
Inspection
v
Filling Compound *Diawine-op
= Binding Tape 2Filing J —
ies
Invemediate
Inspection
—_—~—_,
Filling Compound Fling
“Lap Tape 2) Lap Serving |<¢—
“Identification Tape 5) Sheating
+ Black Polyethylene
Final
Inspection
v
Shipping
=-_
<4
~ 5 quads subunit,
Subunits are inspected according to the
specifications,
specified number of subunits ae lid up
Specified number of units are laid up into
cable core
= Cable cores axe filled with filling com-
pound.
= Core wrapping tape applied helically
Units and cable cores are inspected accord-
ing to the specifications
1) Cable cores are filled with
‘compound,
2) Filled cores are served with Lap tape lon-
‘itudinaly applied
3) Lap served cable cores are
sheathed with polyethylene
Finished cables are inspected finally accord
ing to the specifications
* The MARK means that all manufacturing processes are in tandem operation.
RIYADH TELEPHONE CABLESCommitment to quality Control at all production stages as well
as personnel activities.
Quality control includes the following inspections and testing:
* In-coming raw material Inspection.
* On-line testing and control equipment
*In-between process testing of subunits, units and cable
cores.
* Final testing equipment for low frequency and high
frequency cable characteristics
* Statistical records for the testing standards.
1- Specify quality target data.
2- Recognize problems.
3- Analyse
4- Identify problem solution.
5- Formulate action plan.
6- Implement action plan.
7- Check for success.
8- Set new quality target data.
9- Zero defect.
Zee oy -V- TeExe
1. Copper Conductor 2. Solid PE insulation
3. Identification tape 4, Core wrapping tape
5, Aluminium moisture batier tape (for cables over 100 pairs ) 6. Black PE sheath
7, Sheath masking
Description : Plain solid annealed copper conductor, high density solid polyethylene insulated, paired,
ten pairs sub-unit type, air core, polyethylene sheathed, cable cores over 100 pairs manufactured with a
rmoistute baie, generally complying with Saudi Arabia MOPTT MAT 1011 (EES).
Application : sub cable is used for outside plant networks, installed between manholes and cabinets,
Cables up to 100 paits are connected to cabinets or distribution pillar terminal boxes, Ii suitable for
twopical environmental conditions (from-10°C to + 59°C ambient )
Related Specifications 16 708-1
Dimensions and Standard Packing :
RTC Cable size | Approx. | Approx. | Shipping | Drum Size
Product Outer Dia, | Gross Wi. | Length | (Flange Dia)
No. (No.xmm) | (mm) (Kg) | (Meter) | (mm)
UCEEO 032 10x2x050 100 156 1000 800
UCEEO 012 202x050 125 2s 1000 1000
50x2x050 17 413 1000 1200
uckEO 072 | 100x2x0:50 240 81 1000 1400
UCELO 082 | 200x2x050 330 1664 1000 1800
cso 102 | 300x2x050 395 2363 1000 2000
uceLo 112 | 400x2x050 450 3005 1000 2200
Zee oy V- Te1. Conductor Resistance :
20°C
Maximum average :92 obms/Km
‘Maximum individual 96 obms/Kim
1.1 Resistance Unbalance (% )
Maximum average :0.75
Maximum individual : 2.5
Resistance unbalance shall be
calculated withthe following formula
R (i) =Rmax-Rain x 100
Rmax > Rin
2. Insulation Resistance
‘The Insulation resistance shall not be less than
10,000 mega ohms. ken at 20°C
2.1 Dielectric Withstand Voltage:
DC voltage shall be applied for
sinimum 3 seconde,
Conductor to Conductor: 2000 vos.
Conductor to Sereen = 5000 volts
Mutual Capacitance
(at 10004 200 Hz)
Maximum average 442m F/Km
‘Maximum individual + 50 aFKn
4. Capacitance Unbalance
(at 1000 + 200 Hz)
4.a) Pair to Pair within sub-unit:
Maximum average
20pF/500 m,
‘Maximum individual : 150 pF/500 m.
4.b) Pair to Pair between adjacent
subsunits or units,
‘Maximum average + 20 pF/S00 m.
‘Maximum individual: SO pF/S00 m,
4.c) Ps
to Earth:
‘Maximum average : 500 pF/Km
‘Maximum individual : 2500 pP/Kma
5. Attenuation
‘The attenuation of cables at 1 KHz and
MH shall not exceed the following values
shen corrected 0 4
Max. average attenuation (4B/Km)
AUL KHz,
AUL MHz
145
26
Zee oy -V- TePair to P:
coupling loss:
‘The measurement shall be performed on one randomly selected outer unit and 99% of pair
combinations shall exceed the following values at the specified frequencies,
Frequency Min. NEXT!
(KHz) Limit (4B/Km )
1 85
2 80
80 or
1000 48
6 T and
Power Sums:
‘The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed
the following values at the specified frequencies
Frequency ‘Within Unit ( dB/Km )
(KHz)
Min, NEXT ‘Min. ELFEXT
: 70 ™
Rp o a
o 55 38
1000 37 -
Zee oy -V- Te7
Copper Conductor 2. Cellular PE insulation
3. Identification tape 4. Core wrapping tape
5, Aluminium moisture bavier 6, Black PE sheath
47. Sheath marking
Description : Plain solid annealed copper conductor, high density solid polyethylene insulated,
‘ited, fen pairs sub-unit type, air core, sereened with aluminium moisture barrier and polyethylene
sheathed. compliance with Saudi Arabia MOPTT MAT 1011 (CES),
Application : Air core duct cable is placed in duct and wsed for primary underground distabation
network between manholes and exchanges, having a single jacket cis suitable for tropical
environmental conditions (from-10 ‘C to $5 °C ambien)
Related Sp ns : TEC 708-1
Zee oy -V- TeRTC Cable size | Approx. | Approx. | Shipping | Drum Size
Product, Outer Dia. | Gross Wt. | Length | lange Dia)
No, (No.xmm) | (mm) (Kg) | (Meter) | (mm)
ACCLO 101 | 300x2x0.40 290 1460 1000 1800
ACCLO 121 | 600x2x0.40 390 2500 1000 2000
ACCLO 131 | 900%2x0.40 410 2250 600 2000
ACCLO 141 | 1200x2040 540 1550 300 1800
ACCLO 151 | 1500x2x0.40 600 1950 300 2000
ACCLO 161 | 1800x2040 655 2210 300 2000
accto 1 | 2100x2x040 700 275 300 2200
Acco 181 | 2400x2x040 750 2850 300 2200
ACCLO 102 | 300x2x0.50 350 1960 1000 1800
ACCLO 122 | 600x2x0.50 a5 2325 600 2000
ACCLO 132 | 900%2x0.50 518 10 300 1800
ACCLO 142 | 1200x2050 660 2280 300 2000
ACCLO 152 | 1500x2x050 BS 2705 300 200
ACCLO 162 | 1800x2050 800 sila 300 2200
ACCLO 104 | 300x205 45 1850 600 1800
ACCLO 126 | 600x2x065 61s 1900 300 1800
ACCLO 134 | 900x2x0.65 146 2150 300 2000
ACCLO 144 | 1200x2x 0.65 850 3550 300 2200
ACCLO 076 | 100x2 x090 360 1500 600 1600
ACCLO 106 | 300%2x0.90 59.60 212s 300 1800
Zee oy -V- Te oiAIRCOR!
1. Conductor Resistance:
20°C
‘Copper
Conductor
Dia. (mm) [Average
040 144 150
050 2 96
065 s4 7
090 28 30
3. Mutual Capacitance:
(1000 + 200812)
‘Maximum average 42 nF/Km
‘Maximum individual : 50 nB/Km,
4. Capacitance Unbalance:
(at 1000+ 200 Ha)
4a ) Pair to Earth:
‘Maximum average © 500 pFcm
1.1 Resistance Unbalance: ‘Maximum individual : 2500 pF/kea
Resistance unbalance shall be calculated with the
following forma
R (= Buax-Rmin x 100 . .
Rmax + Risin 4.b ) Pair to Pair:
Copper | Max Resisance Unblancet%) ‘Max. Capacitance Unbalance (pF/S00m)
Conductor
Dia. (mm) [Average | Individual ‘Average | Individual
040 100 2s Within sub-unit 25 150
050 075 25
065 075 20 Between adjacent 7 ss
090 075 20 subunits & units
2. Insulation Resistancs
‘The insulation resistance shall not be less than
5000 mega obs. km. at 20°C
2.1 Dielectric Withstand Voltage
[DC voltage shall be applied for minimum 3 sec
5. Attenuation:
The corrected attenuation Values to 45°C shall
not exceed the following valves
‘onds as given below. Copper ‘Max. Average allenuation
Conductor SEE
Copper ‘Min, Test Voltage (Volts de) Dia (mm) | AtIKHz | Ati MHz
Conductor
Dia. (mm) | Conductor to | Conductor to
Conductor Seren ogo pa &s
050 14s, 26
040 1700 5000 0.65 1 185
050 2000 5000 0.90) 0.80, B33
06s 2500 10000
0.90 3500 10000
Zee oy -V- Te a6. Cross Tall
6.a) Pair to Pair Near-End (NEXT )
coupling loss:
‘The measurement shall be performed on one randomly selected outer unit and 99% of pair
‘combinations shall exceed the following values at the specified frequencies.
Frequency Min, NEXT
(KHz) Limit ( dB/Km )
1 85
2 80
80 6
1000 48
the following values at the specified frequencies.
:X7) and equal level fat-end (ELFEXT) individual power sums shall exceed,
Zee oy -V- Te
Prey Within Unit ( dB/Km )
Min, NEXT Min, ELFEXT
1 0 ”
a 6 n
* 55 58
1000 37 361. Copper Conductor 2. Cellular PE insulation
3, Identification tape 4, Core wrapping tape
5, Aluminium moisture bartier 6. Inner sheath, black PE
7, Water swellable tape 8. Outer sheath, black PE
9, Sheath marking
Description - Plain solid annealed copper conductor, high density cellular polyeth
ylene insulated, paired, ten pairs sub-unit type, air core, screened with aluminium
‘moisture barrier and double polyethylene sheathed with a water swellable tape or
flooding compound between the sheaths, generally complying with Saudi Arabia
MOPTT MAT 1011 specification (CESE),
Application ; Cellular polyethylene insulated, air core, direct buried type cable is
used for primary underground distribution network between manholes and exchanges,
having double polyethylene sheaths for direct buried applications. It is suitable for
topical environmental conditions
(from-10C to + 55 T ambient).
Related Specifications : IEC 708-1
Zee oy -V- TeaT
Dimensions and Standard Packin;
RTC Cable size | Approx. | Approx. | Shipping | Drum Size
Product, Outer Dia. | Gross We | Length | (Flange Dia)
No, (No.xmm) | (mm) (Kg) | (Meter) | (mm)
Acco 101 | 300x2x0.40 33.0 1585 1000 1800
Acco 121 | 600x2x0.40 32 2700 1000 2000
AccDo 131 | 900x2x0.40 sLo 2400 600 2000
AccDO 141 | 1200x2040 58.10 1610 300 1800
AccDO 151 | 1500x2x0.40 640 1880 300 1800
AccDo 161 | 1300x2x0.40 695 2310 300 2000
Acco 171 | 2100x2x0.40 140 2675 300 2200
accpo 181 | 2400x2x040 790 2960 300 2200
accpo 102 | — 300x2x0:50 390.0 2285 1000 2000
AccDo 122 | 600x2x050 sis 2470 600 2000
accpo 132 | 900x2x0.50 ol imo 300 1600
accpo 142 | 1200x2x0.50 700 2380 300 2000
AccDo 152 | 1500x2x0.50 n0 2850 300 2000
accpo 162 | 1800x2x050 840 3325 300 2200
Acco 104 | 300x2x065 485 2s 600 2000
AccDO 124 | 600x2x0.65 657) 1980 300 1800
‘Accpo 134 | 9900x2065 788 2860 300 2000
AccDo 144 | 1200x2065 892 3670 300 2200
acco 076 | 100x2 x0.90 405 1500 600 1600
AccDo 106 | 300x2x090 os 1910 300 1800
Zee oy -V- Te Cited1.Condu
at 20
‘Copper Max, Resistance (OhmsiKi)
Conductor
Dia. (mm) | Average | Individual
040 144 150
050 2 96
06s SA 37
080 28 30
1.1 Resistance Unbalance (%
Resistance unbalance shall be calculated with the
following formula
(v =Rmax-Ruin x 100
Rmax + Ria
Copper | Max Resistance Unbalance(%)
Conductor
Dia. (mm) [Average | Individual
040 1.00) 25
050 075 25
065 075 20
0890 075 20
2. Insulation Resistance:
‘he insulation resistance shall not be es than
5000 mega hm, km. a 20%
2.1 Dielectric Withstand Voltage:
3. Mutual Capacitance
(at 1000 + 200H%2)
Maximum average 44:2 nF/Km
Maximum individual: 50 nF/Km,
4, Capacitance Unbalance:
(at 1000 + 200 Hz)
4.a) Pair to Earth:
500 pF
2500 pm
Maximum average
‘Maximum individual
4. ) Pair to Pais
Max. Capacitance Ui
Within a sub-unit
Between adjacent 1”
‘units or sub-units
5. Attenuation:
‘The comected atenuation Values to 45°C shall
not exceed the following values,
Max. Average avtensation
Copper
[DC voltage shall be applied for minimum 3 see- | Conductor (IK
Dia (mm) | ACIKRR | APTN
nds as given blow
Cor Min. Test Voltage (Volts de) 040 1.81 265
Condictor 050 14s 26
Dia. (nm) | Condictorw | Cendctorto oss un 185
Conductor | Screen 090 080 13
040 1700 000
050 2000 5000
065 2500 10000
030 3500 10000
RIYADH TELEPHONE CABLES 136. Cross Talk:
‘The measurement shall be performed on one randomly selected outer unit and 99% of pair
combinations shall exceed the following values
6.b) NEXT and ELFEXT Individual
Power Sums:
Frequency Min, NEXT
(Kitz) Limit (d18/Km )
1 85
n 80
x0 0
1000 8
‘The near-end (NEXT) and equal evel far-end (ELFEXT) individual power sums shall exceed
the following values at the specified frequencies
Freguney Within Unit (B/Kin )
Min, NEXT Min, ELFEXT
1 70 ™
2 or 1
0 ss a
1000 0 -
Zee oy -V- Te rr1, Copper Conductor 2. Insulation (Foam - skin )
3. Filling compound(jelly) 4. Identification tape
5. Core wrapping tape 6, Aluminium moisture barrier
7. Outer sheath, black PE 8. Sheath marking
Description : Plain solid annealed copper conductor, high density polyethylene
foam skin insulated, paired, ten pairs sub-unit type, jelly filled, screened and black
polyethylene sheathed, duct type primary and secondary local telephone cable,
generally complying with Saudi Arabia MOPTT MAT 1101 specification (CEP).
Application : Polyethylene insulated water proof (jelly filled) CEF type cables are
used for primary and secondary underground distribution networks, (i.., in the secon-
dary network between cross-connection cabinets and the subscribers connections, in
the primary network between the exchange and cross-connection cabinets). CEF pro-
duced for duct installation with a single black polyethylene sheath. It is suitable for
tropical environmental conditions ( from- 10°C to + 55 °C ambient)
Related Specifications : IEC 70:
Zee oy -V- TeDimensions and Standard eae
RTC Cable size | Approx. | Approx. | Shipping | Drum Size
Product, Outer Dia, | Gross We | Length | (Flange Dia)
No, (No.xmm) | (mm) (Kg) | (Meter) | (mm)
FCKLO 041 20x2x040 110 202 1000 800
FCKLO 061 50x2x0.40 150 369 1000 1000
FCKLO 071 | 100x2x040 195 44 1000 1200
FCKLO 091 | 200x2x0.40 260 1214 1000 1600
FCKLO 101 | 300x2x040 310 1602 1000 1600
FCKLO 121 | 600x2x040 20 1879 600 1800
FCKLO 131 | 900x2x040 sho 27 600 2000
FCKLO 141 | 1200x2x0.40 sas 1330 300 1800
FCKLO 151. | 1500x2x0.40 655 2315 300 2000
FCKLO 161 | 1800x2x040 as 2662. 300 2000
FCKLO 032 10x 2x050 100 174 1000 800
FCKLO 042 202x050 25 280 1000 1000
FCKLO 062 50x2x050 175 si0 1000 1200
FCKLO 072 | 100x2x0.50 2s 908 1000 1400
FCKLO 092 | — 200x2x0.50 ais 1730 1000 1800
FCKLO 102 | 300x2x0.50 380 167 600 1600
FCKLO 122 | 600x2x0.50 325 2816 600 2000
FCKLO 132 | 9900x2050 630 2030 300 1800
‘cKLO 142 | 1200x2%0.50 ms 20 300 2000
FCKLO 044 20x2x0.65 150 313 1000 1000
FCKLO 06¢ 50x2x 0.65 15 800 1000 1400
FCKLO 074 | 100x2x0.65 295 1 600 1400
FCKLO 094 | 200x2x0.65 405 1593 600 1600
FCKLO 10¢ | 3090x2065 480 2409 600 2000
FCKLO 126 | 6090x2065 610 2368 300 2000
‘CKLO 046 20x2x090 195 3m 600 1000
FCKLO 066 50x2x090 290 816 600 1400
FCKLO 076 | 100%2x0.90 395 sai 600 1600
FCKLO 096 | 200%2x0.90 sto 1870 300 1600
FCKLO 106 | 300x2x090 650 2m 300 2000
Zee oy -V- Tenductor Resistance:
at 20°C
Copper Max Resistance (Obna/Kim)
Conductor
Dia (am) [Average | Individual
0.40 144 150
050 92 96
0.65 54 37
0.90 2 30
1.1 Resistance Unbalance (%):
Resistance unbalance shall be ealeulated with the
following formula
R (%) =Rmax-Rmin x 109
3. Mutual Capacitance:
{at 1000 = 200112)
‘Maximum average
aK
‘Maximum individual : SO nF/K,
4. Capacitance Unbalance:
(at 1000 + 200 Hz)
4.a) Pair to Farth:
Maximum average
500 pcm
‘Maximum individual : 2500 pk
4.b ) Pair to Pais
max +Rmin fax. Capacitance Unbalance (pF/500m)
Copper Max, Resintance Unbelancel®) “Average | Individual
Condictor
Dia (am) [Average | Individual
‘Within a sub-unit 2s 150
0.40 1.00 25
ooo bos Bs Saal ” 35
0.65 075 20 suns oF sub units
0.90 07s 20
2. Insulation Resistance:
‘The insulation resistance shall not he less than
2500 mege ohm. km, at 20°C
2.1 Diclect thstand Voltage
DC voltage shal be applied for minimum 3 sec
fonds as given below.
Copper ‘Min. Test Voltage (Volts de)
Conductor
Dia. (am) [ Conductor to | Conductor to
Conductor Screen
0.40 2400 5000
0.50 2400 000
06s 3000 10000
030, 3600 10000
5. Attenuation
The corrected atfenation values to 45°C shall not
exceed the following values.
Copper Max, Average attenuation
Conductor (aB/Kmn)
Dia. (mm) | AtKHe ‘ACMHz
0.40 181 253
050 145 210
065 110. 163
0.90 0.30 136
Zee oy -V- Te me6. Cross Talk:
6.a) Pair to Pair Near-End (NEXT.
coupling loss:
‘The measurement shall be performed on one randomly selected outer unit and 99% of pair
combinations shall exceed the following values at the specified frequencies.
Frequency Min, NEXT
(KHz) Limit (4B/Km
1 85
2 80
80 a
1000 48
‘The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed
the following values at the specified frequencies
Zee oy -V- Te
Fregueey Within Unit (dB/Km )
. Min. NEXT Min, ELFEXT
' 0 "
2 1 1
so 55 58
1000 a xuPAO LOTTO
10 9 8 76543 2 1
1. Copper Conductor 2. Insulation (Foam - skin )
3. Filling compound(jelly) 4, Identification tape
5. Core wrapping tape 6. Aluminium moisture barrier
7. Inner sheath, black PE 8. Water swellable tape
9. Outer sheath, black PE, 10, Sheath marking
Description : Plain solid annealed copper conductor, high density polyethylene
foam skin insulated, paired, ten pairs sub-unit type, jelly filled, screened with alumin-
ium moisture barrier and double black polyethylene sheathed, with water swellable
tape or flooding compound between the inner and outer sheaths, direct buried type, pri-
mary and secondary local telephone cable, (CEFE) generally complying with Saudi
Arabia MOPTT MAT 1101 specification
Application : Polyethylene insulated water proof (jelly filled) CEFE type cables
are used for primary and secondary underground distribution networks, (i.¢., in the sec-
ondary network between cross-comnection cabinets and the subscribers connections, in
the primary network between the exchange and cross-connection cabinets). CEFE pro-
duced for direct buried installation with double black PE sheath itis suitable for tropi-
cal environmental conditions ( from- 10°C to + 55 °C ambient)
Related Specifications : IEC 70!
RIYADH TELEPHONE CABLESJELLY FILLED CABLE DIRECT BURIED TYP!
Dimensions and Standard Packin;
RTC Cable size] Approx. ] Approx. | Shipping | Drum Size
Product Outer Dia, | Gross Wi. | Length | (Flange Dia)
No. (No.xmm) | (mm) | (KG) | (Meter) | (mm)
FCKDO 041 20x2x040 14s 300 1000 1000
FCKDO 061 50x2x040 Iss 500 1000, 1200
FCKDO 071 | 100x2x0.40 230 sil 1000, 1400
FcKDO 091 | 200x2x0.40 300) 1440 1000 1800
FCKDO 101 | 300x2x040 34s 1985 1000, 2000
FKDO 121 | 6002x040 460 2160 600 2000
FCKDO 131 | 900x2x0.40 550 2073 600 2200
FCKDO 141 | 1200x2x040 20 1908 300 1800
FCKDO 151 | 1500x2x0.40 69.0 2413 300 2000
FCKDO 161 | 1800x2040 750 2870 300 2200
FCKDO 032 10x2x050 Bs 269 1000 1000
FCKDO 042 202x050 1690 348 1000 1000
FCKDO 052 50x2x050 210 653 1000 1400
FeKDo 072, | 1002x050 210 16 1000 1600
FCKDO 092 | 200x2.x050 350 2020 1000 2000
FCKDO 102 | 300x2x0.50 41s 1615 600 1800
FCKDO 122 | 600x200 560 3033 600 2200
FCKDO 132 | 900x200 665 2s 300 2000
FcKDO 142 | 1200x2050 760 2930 300 2200
FCKDO 044 202x065 iss. 506 1000, 1200
FCKDO 054 50x2x065 250 1008 1000, 1600
FCKDO 074 | 100x2.x0.65 330 1087 600 1600
FCKDO 094 | 200x2.x0.65 440 1794 600 1800
FCKDO 104 | 300x2x0.65 51s 2553 600 2000
FCKDO 124 | 600x2.x0.65 0S 2467 300 2000
FCKDO 046 202x090 230 489 600 1200
FCKDO 056 50x2x080 325 1005 600 1600
FcKDO 076 | 1002x090 430 1739 600 1800
FCKDO 086 | 1502x090 505 600 2000
FCKDO 096 | 2002x090 51s 1670 300 1800
FCKDO 105 | 300x200 100 24 300 2000
Zee oy -V- Te1. Conductor Resistance
at 20°C
Copper ‘Max Resistance (Obns/Km)
Condictor
Dia. (mm) [Average | Individual
0.40 14 150
0.50 92 96
0.65 54 37
0.90 28 30
1.1 Resistance Unbalance(%):
Resistance unbalance shall be calculated with the
following formula
R (%) =Rmax-Rmin x 100
imax +Rmin
Copper Max. Resistance Usblanc()
Condictor
Dia (mm) [Average | Individual
0.40 1.00 25
0.50 075 25
0.65 075 20
0.90 07s 20
2. Insulation Resistance:
‘The insulation resistance shall not be less than
2500 megs ohm. km, at 20°C
24 Dielectric
stand Voltage:
DC voltage shall be applied for minimum 3 seo
ionds as given below.
Copper ‘Min, Test Voliage (Volts de)
Conductor
Dia. (mm) | Conductorto | Conductor to
Conductor Sereen
040 2400 5000
050 2400 5000
065 3000 10000
0.90) 3600 10000
3. Mutual Capacitance:
{at 1000 + 200TK2)
Maximum average 44% 2 aF/Km
‘Maximum individual 50 nF 7K,
4. Capacitance Unbalance:
(at 1000 + 200 Hz)
4a) Pair to Earth:
500 pF
‘Maximum individual : 2500 pF/km
Maximum average
4.b ) Pair to Pair:
‘Max. Capacitance Unbalance (pF/500m)
‘Average | Individual
‘Within sub-unit 2s 150
Between adjacent ” 5s
“units or sub-units
ttenuation: ;
‘The corrected attenuation values to 45 C shall not ex-
ceed the following values.
Copper ‘Max, Average atenuation
Condicioe (aB/Km)
Dia. (mm) | AUIKHz | AUIMHz
040 181 257
050 14s 210
065 110 163
0.90 0.30 B6
Zee oy -V- Te6. Cross Talk:
6.a) Pair to Pair Near-End (NEXT )
coupling loss:
‘The measurement shall be performed on one randomly selected outer unit and 99% of pair
combinations shall exceed the following values at the specified frequencies.
Frequency Min, NEXT
(Kuz) Limit (aB/Km)
1 85
2 %0
%0 a
1000 6
6.b) NEXT and ELFEXT Individual
Power Sum:
‘The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed
the following values atthe specified frequencies.
Frequency Within Unit (4B/Km )
oe) Min, NEXT Min ELFEXT
1 7 ™
2 o n
% 8 ss
1000 30 46
Zee oy -V- Te LSELF TING AERIAL
8 7 54 3 20 21
1, Copper Conductor 2. Solid PE Insulation
3. Identification tape 4, Core Wrapping tape
5, Aluminium moisture barrier 6, Stranded Support Messenger
7. Polyethylene black sheath (galvanized steel wires )
8. Sheath marking
Description : Plain solid annealed copper conductor, high density solid polyethy-
lene insulated, paired, ten pairs sub-unit type, aluminium moisture barrier screened,
black polyethylene sheathed self supporting aerial cables (EEMS) generally comply-
ing with Saudi Arabia MOPTT MAT - 1201 specification.
Application : EEMS self supporting aerial cable is used in the telecommunication
network, particularly in local networks on poles and walls.
Related Specifications 708-1
Zee oy -V- TeDimensions and Standard Packin;
pire, ] cose | pamees, | Be S| nan ads eat ame
No. (No. x mm ) (mm) (mm) (mm) | (Kg) | (Meter) | (mm)
Serta] eoeeees (eee (mer eee (ero es
sesto os] wox2xas0)9sxssxsio] 118 | 20428]502| 100 | 200
Zee oy -V- Te i1. Conductor Resistance
at 20°C
Copper ‘Max, Resistance (Ohms/K)
Conductor
Dia. (mm) [Average | Individual
oo 144 150
030 2 96
065, 54 7
090 28 30
L
Resistance unbalance shall be calculated with the
following formula
3. Mutual Capacitance:
{at 1000 + 200F%2)
‘Maximum average
4422 oP /Km
‘Maximum individual 50 nF/Km,
4, Capacitance
(at 1000 + 200 Hz)
4.a) Pair to Karth:
Maximum average
500 pF/km
Unbalance:
R() =Rmax-Rmin x 109 Maximum individval : 2500 pm
max + Rin
Copper | Max Resistance Unbalnce(®) | 4.b ) Pair to Pair:
Conductor
Dia. (mm) [Average | Individual
040 Ma og ‘Max. Capacitance Unbalance (pF/500m)
os ons & ‘Average | Individual
065 075 20
on on 20 ‘Within a sub-unit n 150
2. Insulation Resistance: Between adjacent 2» 50
‘The instlation resistance shall not be less than ay
10000 mega ohms. ka, at 20°C
24 Dielectric Withstand Voltage:
DC voltage shall be applied for minimum 3 sec
5. Attenuation:
‘The corrected attenuation values to 45°C shall not
exceed the following values.
onds as given below. Each insulated conductor — iS
shall be able to withstand 220 V. de. for one mnie (aB/Km)
minute Dia. (mm) | ACIKAz | AUIME
Copper Min Test Volage (Vis d) 040 a a
armed oso 1st 42
Dia (mm) [ Conductor to | Conductor to oe a ae
Conductor Screen
0.90 os 143
040 1700 5000
050 2000 5000
065 2500 10000
090 3500 10000
Zee oy -V- Te6. Cross Talk:
6.a) Pair to Pair Near-End (NEXT )
coupling loss:
‘The measurement shall be performed on one randomly selected outer unit and 99% of pair
combinations shall exceed the following values at the specified frequencies
Frequency ‘Min. NEXT,
(KHz) Limit ( 4B/Km )
1 85
2 80
80 a
1000 48
6.b) NEXT and ELFEXT
Individual Power Sums:
‘The near-end (NEXT) and equal level far-end (ELFEXT) individual power sums shall exceed
the following values at the specified frequencies
Frequency ‘Within Unit (dB/Km )
cM) Min, NEXT ‘Min, ELFEXT
1 70 “
rey 6 n
80 55 38
1000 7 36
Zee oy -V- TeBURIED SERV i
6 5 43 2 1
1, Copper Conductor 2. High density PE Insulation
3. PVC inner sheath 4. Identification Tape.
5. Aluminium moisture barrier 6. Outer Sheath, PE black
Description : Plain solid annealed copper conductor, high density solid poly-
ethylene insulated, quad form, air core, PVC inner sheathed moisture barrier
aluminium screen and low density polyethylene outer sheathed buried service
wire (BSW) complying with MOPTT MAT - 1301 specification.
Application : Buried service wire is used for direct buried installation in the
outside plant network between distribution points and subscribers terminal
boxes.
Dimensions and Standard Packing:
RTC cablesize | Approx. | Approx. | Shipping | Drm Suze
Product Outer Dia. | Gross We. | Length | (Flange Dia)
No. (No.xmm) | (mm) | (Kg) | (Meter) | (mm)
BCEMO 022 | 1X4x050 83 110 1000 600
Zee oy -V- Te rea1. Conductor Resistance: 3. Mutual Capacitance:
{at 1000 +200 Hz)
sge 92 ohms/Km ‘Maximum average 44+ 2 nF/Km
‘Maximum individual : 96 obms/Kin ‘Maximum individual. 50 nF/Kin
1.1 Resistance Unbalance (%):
4. Capacitance Unbalance:
(at 1000 + 200 Hz)
Maximum average 075
Maximum individual 2.5
Resistance unbalance shall be calculated with
the following formula 4.a) Pair to Pair:
‘Maximum average ‘500 pF/km_
AR (%) =Rmax-Rmin Xx 100 Maximum individual :2500 pF/km.
5, Attenuation:
‘The attenuation of cables at 1 KHz and 1 MHz
shall not exceed the following values when cor:
less than 10,000 mega of km at 20% rected 10 45°C
2.1 Dielectric Withstand Voltage:
“The insulation resistance shall not be
DC voltage shall be applied for minimum 3 sec-
ond.
Conducta to Conductor: 3000 Valts
Conducta to Screen: 10000 vols
Each con
inctor shall be able o withstand a po-
tential 250V de, for 1 minute
Maximum average attenuation dB/Km
1 KHz 1 MHz
145 22.6
RIYADH TELEPHONE CABLES GDROP WIR!
PRODUCT CODE :DSEO.
1. Copper coated Steel Wire
2. High density polyethylene Insulation
Description : Hard drawn copper coated steel parallel laid conductors, high
density solid polyethylene insulated telephone drop wire complying’ with
MOPTT MAT- 1311
Application : Drop wires are used for outdoor connections between distribu-
tion points and subscribers premises.
ensions and Standard Packing:
RTC Cable size | Approx. | Approx. | Shipping ] Coil Size
Product, Outer Dia. | Gross We. | Length | (odfid/width)
No. (No.xmm) | (mm) (Kg) | (Meter) | (mm)
DSEO 015 2x0.80 60x30 50 250 [282x150 x100|
Zee oy -V- TeDROP WIRE
ELECTRICAL AND TRANSMISSION CHARACTERISTICS
1 Conductor Resistance:
at 20°C
Maximum average: 88 obms/Km
Maximum individval: 92 obms/Kim
1.1 Resistance Unbalance (%):
Maximum average: 10
Maximum individual 3.6
Resistance unbalance shall be calculated with
the following formula
2, Insulation Resistance:
The insulation resistance shall not be
less than 500 mega obm km at 20°C
2.1 Dielectric Withstand Voltage:
DC voltage shall be applied for minimum 60
seconds
Conductor to Conductor: 1500 Volts
3. Insulation Integrity between
‘h conductor t rt
To withstand 1Sky ac. for five minutes.
4. Mutual Capacitance:
(at 1000 + 200 Hz)
‘Maximum average 40 n5/KM
Zee oy -V- TeRDANT INDOOR TELEPHONE CABLE
6 4 3 2 1
1. Copper Conductor 2. PVC Insulation
3. Identification Tape 4, Core Wrapping Tape
5. Sheath Rip Cord 6, Halogen free Flame Retardant Grey
coloured sheath.
Description : Plain solid annealed copper conductor, PVC insulated,paired
ten pairs sub-unit type, air core , flame retardant halogen free polymer
sheathed indoor telephone cable with rip cord (VRB) complying with
MOPTT MAT-1401 specification
Application ; VRB Indoor Cable is used for indoor installation in the tele-
communication network.
Dimensions and Standard Packing:
RTC Cable size | Approx. | Approx. | Shipping | Drum Size
Product, Outer Dia. | Gross We | Length | (Flange Dia)
No. (No.xmm) | (mm) | (Kg) | (Meter) | (mm)
IcvHo 032 | 10x2x050 85 157 1000 800
Icvnoo42 | 20x2x050 | 1s 233 1000 800
IcvHo 052 | 30x2x050 | 135 342 1000 1000
IcvHo0s2 | 50x2x0.50 170 533, 1000 1200
IcvHo 072 | 100x2x050 | 23.0 936 1000 1400
IcvHO 082 | 150x2x050 | 275 1374 1000 1600
ICVHO 092 | 200x2x050 | 315 1406 1000 1600
IcvHO 102 | 300x2x050 | 380 2585 1000 2000
RIYADH TELEPHONE CABLES1, Conductor Resistance:
at 20°C
‘Maximum average: 92 ohms/Km
‘Maximum individual : 96 ohms/Kmn
1.1 Resistance Unbalance (%):
‘Maximum average 0.75
Maximum individual 2.5
Resistance unbalance shall be ealeulsted with
the following formula
(go) =Rmax-Rmin x 100
max + Rin
2. Insulation Resistan
“The insulation resistance shall not be
less than $00 mega ohm km at 20°C
2.1 Dielectric Withstand Voltag
DC voltage shall be applied for minimum 60
seconds
‘Conductor to Conductor: 1500 Volts
3. Mutual Capacitance:
‘at 1000 — 200 Hz)
Maximum average: 75-2 nF/Km.
‘Maximum individual: 90 nF/Km
4. Capacitance Unbalance:
(at 1000 + 200 Hz)
Pair to Pair within a sub-unit:
‘Maximum average: 22 pF/S00m
‘Maximum individual :150 pF500m.
4.b) Pair to Pair between adjacent
sub-units or units:
‘Maximum average = 20 p/500m
‘Maximum individual: 50 pF/S00m,
RIYADH TELEPHONE CABLESJUMPER WIRE
PRODUCT CoD!
1. Copper Conductor
2.. PVC or high density polyethylene Insulation
3. Transparent Nylon Sheath
Description : Plain solid annealed copper conductor, PVC or high density
polythylene insulated, single pair, and nylon jacketed jumper telephone wire
complying with MOPTT MAT 1501 specification types OP-CAB and CO -
AX2
Application : The polyethylene insulated jumper wires are generally used in
‘outdoor cabinets for cross connection between primary and secondary terminal
block. The PVC insulated jumper wires are used in main distribution frames in
exchangebuildings.
Dimensions and Standard Packing:
RTC able | Cable size | Approx. | Approx. | Shipping Coil Size
Product. | ‘Type OvierDia.| Gross We] Length | (odiawicth)
No. (Noxmm)| (am) | (ke) | (Meter) (mm)
scwo 013 J op-can | 1x2x060 | 25 41 | 500 | 250x 150x100
sceno 013 | co-ax2 | 1x2x060 | 20 34 | s00 | 220% 150% 100
Zee oy -V- Tejuctor Resistance:
at 20
Maximum average = 62 obms/Km
‘Maximum individual : 66 ohms/Kin
2. Resistance Unbalance (%):
‘Maximum average 0.75
Maximum individual 2.0
Resistance unbalance shall be
calculated withthe following formula
R(%) =Rmax-Rmin x 109
Rmax+ Rmin
Zee oy -V- Te
3. Insulation Resistance:
The insulation resistance for PVC shall not be
less than 5000 mega olin kam and for polyethy=
lene insulation shall not be less than 10,000
‘mega ohm km. at 20°C
4. Dielectric Withstand
Voltage:
DC voltage shall be applied for
‘minimum 60 seconds
Conductor ta Conductor: 1500 VoltsOT
1, Copper Conductor
2, PVC Sheath (Flame Retardant) light grey.
Type-B
1. Copper Conductor
2. PVC Insulation
3. PVC Sheath (Flame Retardant) light grey.
Description: Two types of Indoor Telephone Wire complying to MOPTT,
MAT-1411
‘Type A. : Plain solid annealed one pair parallel copper conductors, flame re-
tardant PVC sheathed indoor telephone wire.
Type B : Plain solid annealed copper conductor PVC insulated, quad form,
flame retardent PVC sheathed indoor telephone wire.
Application ; The Indoor Wires are used for installation between internal
distribution points on subscribers termination blocks to the wall mounted tele-
phone sockets.
Dimension & Standard Packing:
RTC Cable size Approx. | Approx. | Shipping Coll Size
Product OuerDa | Gross Wt | Length | (odsidiwidthy
No. (No.xmm) | (omy _| (Key | (Meter) (om)
RcHo 014 | A-2x065 | sox1a | 225 250. | 186x 150x100
RcvHo 02 | B-1x4x065 | 62 123 250 | 36x 150x135
RIYADH TELEPHONE CABLES1, Conductor Resistance: 2. Insulation Resistance:
at 20
54 ohme/Kmn ‘The insulation resistance shall not be
Maximum average
Maximum individual : 57 ohms/Km less than 500 mega ohm km, at 20 °C
Jectric Withstand Voltage:
1.1 Resistance Unbalance (%)
Conductor to Conductor: 1500 V. de.
Maximum average 13, or a minimum 60 second,
Maximum individual 3.6
Resistance unbalance shall be
calculated withthe following formula
R(%) =Rmax=Rmin x 100
Remax + Rin
3. Mutual Capacitance
(at 1000 + 200 Hz)
‘Type A: 100 £5 nFykm
‘Type Be 75 45 nF/em
Zee oy -V- Te Ged