Electrical Machines [EE/EEE] Answer Keys
Synchronous Machine Sheet - 01
1. 2. 3. 4. 5. 6. 7. 8. 9. 10.
A C A B A B D D A D
11. 12. 13. 14. 15. 16. 17. 18. 19. 20.
A B C C B B B D C C
21. 22. 23. 24. 25. 26. 27. 28. 29. 30.
D D D C B D A B A C
31. 32. 33. 34. 35. 36. 37. 38. 39. 40.
D C A A D C B B C B
41. 42. 43. 44. 45. 46. 47. 48. 49.
A B C B A D B D C
Electrical Machines [EE/EEE] Answer Keys
Synchronous Machine Sheet - 02
50
B
51. 52. 53. 54. 55. 56. 57. 58. 59. 60.
D C C A A B D 0.844 D C
61. 62. 63. 64. 65. 66. 67. 68. 69. 70.
D B D A A B C B B D
71. 72. 73. 74. 75. 76. 77. 78. 79. 80.
B B A B B A B B 8 B
81. 82. 83. 84. 85. 86. 87. 88. 89. 90.
18 B A A C B C A C 0.8186
91. 92. 93. 94. 95. 96. 97. 98. 99. 100.
0.075 0.25 0.943 37 D C B B 49.85 988
101. 102. 103. 104. 105. 106. 107. 108. 109. 110.
9.9 C D C C A C D B A
111. 112. 113. 114. 115. 116. 117. 118. 119. 120.
0.935 D C B A A 0.894 A 12.93 A
121. 122. 123. 124. 125. 126. 127. 128. 129. 130.
C A B C B A D B D B
131. 132. 133. 134. 135. 136. 137. 138. 139. 140.
A A B C B 1.5 1.06 C 282.8 A
141. 142. 143. 144. 145. 146. 147. 148. 149. 150.
C B D D B 1.675 C 0.9127 B B
151. 152. 153. 154. 155. 156. 157. 158. 159. 160.
A D B B B C B C C A
161. 162. 163. 164. 165. 166. 167.
B C B C B A A
2 Synchronous Machine
S 180 1800 1800
149. m 5 12
P P 12 3 S / P 180 / 12
sin(m / 2) sin(5 120 / 2)
Kd1 0.9567
m sin( / 2) 5sin(120 / 2)
sin(3 5 120 / 2)
Kd 3 0.6472
5sin(3 120 / 2)
conductors 180 slots
Z ph 5 300
slot 3 phase
E ph1 2.22 0.9567 50 0.02 300 637.16 V
K d 3 33 0.6472
E ph 3 E ph1 637.16 3 0.1 129.31 V
K d 1 1 0.9567
Order of slot harmonics :
2S 2 180
n 1 1 29, 31
P 12
K dn K d 1 K d 29 K d 31 K d 1 0.9567
Slot harmonic flux generates two emfs of 2% each for 29th and 31st harmonics. Since the winding factors are equal, a
slot harmonic flux of 4% generates harmonic emfs of 2% of the fundamental frequency emfs.
E ph 29 E ph 31 0.02 E ph1 0.02 637.16 12.74 V
E ph E ph
2
1 E ph 3 E ph 29 E ph 31
2 2 2
E ph 637.162 129.312 12.742 12.742 650.4 V
EL 3 E 2
ph1 E 2
ph 29 E 2
ph 31
EL 3 637.162 12.742 12.742 1104 V
Ans. (B)
ESE Conventional Answers :
2. 5701.68 V
3. 994.37 V
Electrical Machines [EE/EEE] Answer Keys
Synchronous Machine Sheet - 03
168. B 169. C 170. B
171. D 172. 0.855 173. A 174. C 175. A
176. B 177. C 178. C 179. C 180. C
181. B 182. D 183. D 184. A 185. B
186. C 187. B 188. A 189. A 190. B
191. A 192. C 193. 150 194. A 195. C
196. D 197. B 198. A 199. C 200. D
201. B 202. A 203. B 204. 40 205. 3.84
206. 15.15 207. 3.41 208. 11.145 209. B 210. A
211. 0.843 212. D 213. B 214. D 215. 140
216. 1200 217. B 218. C 219. B 220. D
221. A 222. 48 223. B 224. D 225. C
226. * 227. * 228. * 229. 13.56 230. –14.55
231. 15.06 232. D 233. C 234. A 235. A
236. A 237. C 238. D 239. B 240. C
241. B 242. C 243. A 244. A 245. A
246. A 247. A 248. C 249. C 250. A
251. A 252. D 253. B 254. C 255. C
256. 3.32 257. 2.24 258. C 259. 36.18 260. 21.64
261. D 262. C 263. * 264. B 265. C
266. B 267. B 268. D 269. A 270. B
271. C 272. B 273. D 274. A 275. D
276. D 277. B 278. D 279. C 280. A
281. C 282. C 283. A 284. B 285. D
226. (1) 38.97 (2) 72.76%
(3) 22.80 (4) 750 kW
(5) 3.81 kV, 1000 kVA
227. (1) 0.974 lead (2) 0.08 lag
(3) 29% (4) 10%
228. (1) 7372.6 V (2) 10.5%
(3) 14.110
263. (1) 0.12 ohm, 1.068 ohm
(2) 22.8%
Electrical Machines [EE/EEE] Answer Keys
Synchronous Machine Sheet - 04
286. 0.808 287. 0.109 288. 33.47 289. 2.731 290. *
291. A 292. D 293. C 294. A 295. D
296. 1.8 297. D 298. * 299. B 300. D
301. B 302. C 303. D 304. A 305. D
306. A 307. B 308. C 309. C 310. A
311. C 312. B 313. C 314. B 315. D
316. C 317. A 318. D 319. A 320. C
321. A 322. B 323. D 324. B 325. A
326. D 327. C 328. D 329. A 330. B
331. C 332. C 333. B 334. B 335. C
336. A 337. B 338. C 339. C 340. B
341. C 342. B 343. C 344. B 345. C
346. A 347. D 348. A 349. B 350. C
351. D 352. D 353. D 354. D 355. D
356. B
298. (a) 24 MW
(b) 1775 A, 0.706 lead
301. (B)
VT 10000 / 3 5773.5 V
E f 5773.5 300 36.860 (0.4 j 6)
7082.6711.140 V
No change in losses Pin Ploss Pout constant
Steam input is constant P VT I a cos constant
I a cos I a1 cos 1 300 0.8 I a1 1
The current at unity power factor, I a1 240 00 A
EF 1 5773.5 24000 (4 j 6) 6043.5613.770 V
EF EF 1 7082.67 6043.56
Percentage change (decrease) in emf 100 % 14.67 %
EF 7082.67
316. (C)
208 9 103
Vt 120.1 V Ia 24.98 A
3 3 208
EF (Vt cos I a Ra )2 (Vt sin I a X s )2
(120.1 0.8 24.98 0.3)2
EF 222.52 V
(120.1 0.6 24.98 5) 2
2 Synchronous Machine
317. (A)
Pout 3 120.1 24.98 0.8 7200.23 W
Pcu 3 24.982 0.3 561.6 W
Pfield 52 4.5 112.5 W
Pin 7200.23 561.6 500 112.5 8374.33 W
Pout 7200.23
100 100 86%
Pin 8374.33
ESE Conventional Solutions :
11 7 MVA
3. Terminal voltage, VT 6.351 kV Armature current, I a 367.4 A
3 3 11 kV
(1) Load angle, 400
( I a X S ) 2 E F2 VT2 2 E F VT cos (367.4 12) 2 E F2 (6351) 2 2 E F 6351 cos 40 0
E F2 9730.3 E F 20897683.56 0 EF 6530.1 V, 3200.2 V
As steam input is increased EF VT , so, EF 6530.1 V
EF VT 00 6530.1 400 6351
Ia 367.417.810 A
jX S j 12
Armature current is 367.4 A and power factor is cos17.810 = 0.952 lead Ans.
3EF VT 3 6530.1 6351
Active power delivered, P sin sin 400 = 6.664 MW Ans.
XS 12
3VT 3 6351
Reactive power delivered, Q
XS
EF cos VT 12 6530.1cos 400 6351 2.141 MVAR Ans.
The alternator is absorbing reactive power and operating at leading power factor i.e. under excited.
(2) No reactive power flow
Without any change in steam input, alternator can be made to deliver zero reactive power at unity power
factor condition. By increasing the excitation the alternator’s power factor can be changed from leading to
unity (under excited to normal excited).
3EF VT
P 3VT I a cos sin constant I a 'cos ' I a cos
XS
I a ' 1 367.4 0.952 Armature current, I a ' = 349.76 A Ans.
E F ' ' VT jI a ' X S 63510 0 j 349.7600 12 7612.5533.460 V
Excitation voltage is 3 7612.55 = 13.185 kV and load angle is 33.460 Ans.
.1 V .55
V
5 30 2
=6 jI a X S
= 761 jI a ' X S
EF I a = 367.4 A EF
f = 17.810 d ' = 33.460
d = 400 VT = 6351 V I a ' = 349.76 A VT = 6351 V
3 Synchronous Machine
4. Ra 0.01 pu X s 1 pu cos 0.8 E F VOC 2.1 pu I a 1 pu (Rated power)
Induced emf at lagging p.f. : EF2 (VT cos I a Ra ) 2 (VT sin I a X s ) 2
2.12 (VT 0.8 1 0.01) 2 (VT 0.6 1 1) 2 2.12 0.64VT2 0.012 0.016VT 0.36VT2 1 1.2VT
VT2 1.216VT 3.4099 0 VT 1.336 pu, 2.552 pu
Terminal voltage, VT 1.336 pu Ans.
For minimum excitation voltage, power factor is zero leading i.e. cos 0 and sin 1
When I a Constant
Induced emf at leading p.f., EF2 (VT cos I a Ra ) 2 (VT sin I a X s ) 2
EF2 (0 1 0.01) 2 (1.336 1 1 1) 2 Minimum excitation voltage, E F min 0.3361 pu Ans.
5. Terminal voltage, VT 1 pu Excitation voltage, EF 1.5 pu
Total synchronous reactance, X s 0.725 0.11 0.835 pu Active power output, Pout 0.25 pu
EF VT 1.5 1
Pout sin 0.25 sin 80
Xs 0.835
VT 1
Reactive power output, Qout EF cos VT
1.5cos80 1 0.5813 pu
Xs 0.835
(1) Turbine torque is increased by 100% keeping the excitation constant i.e. active power output is increased by
100% so Pout ' 0.5 pu at constant EF .
EF VT 1.5 1
Pout ' sin ' 0.5 sin ' ' 16.160
Xs 0.835
VT 1
New reactive power output, Qout ' EF cos ' VT 1.5 cos16.160 1 0.5278 pu
Xs 0.835
Qout ' Qout 0.5278 0.5813
% change in reactive power 100 100 9.2% Ans.
Qout 0.5813
(2) Turbine torque is constant at the initial value but the excitation is increased by 20% i.e. E f '' 1.2 E f
1.2 1.5 1.8 pu and Pout is constant at 0.25 pu .
E f ''VT 1.8 1
Pout sin '' 0.25 sin '' '' 6.660
Xs 0.835
VT 1
New reactive power output, Qout '' E ''cos '' VT 1.8cos 6.660 1 0.9435 pu
Xs F 0.835
Qout '' Qout 0.9435 0.5813
% change in reactive power 100 100 = 62.3% Ans.
Qout 0.5813
11000 15 MW
6. Terminal voltage, VT 6350.85 V Armature current, I a 984.12 A
3 3 11 kV 0.8
Excitation emf is increased to 130% i.e. EF 1.3VT 1.3 6350.85 8256.1 V
At lagging power factor, E F2 (VT cos I a Ra ) 2 (VT sin I a X s ) 2
8256.12 (6350.85 0.8 0) 2 (6350.85 0.6 984.12 X s ) 2
Synchronous reactance, X s 2.74 Ans.
4 Synchronous Machine
Before the excitation emf is increased (at the time of synchronizing), EF VT 6350.85 V
3EF VT 3 6350.85 6350.85
P sin 15 106 sin
Xs 2.74
Load angle, 19.850 Ans.
EF VT 00 6350.85 19.850 6350.85
Armature current, I a 799 9.9250 A
jX s j 2.74
Armature current is 799 A at power factor cos 9.9250 = 0.985 lead Ans.
OR
EF VT 19.850 9.9250 cos 9.9250 0.985 lead
2
I X I a 2.74 19.850
sin sin a s sin I a 799 A
2 2VT 2 6350.8 2
7. Terminal voltage, VT 11/ 3 6.351 kV Armature current, I a 220 A
Synchronous reactance, X s 10 Armature resistance, Ra 0
Generated emf at unity pf, EF (VT I a Ra ) 2 ( I a X s ) 2 (6351 0) 2 (220 10) 2 6721.25 V
Emf is raised by 25% i.e., E F ' 1.25 E F 1.25 6721.25 8401.56 V
Power input, Pin 3VL I a cos 3 11k 220 1 4191.56 kW
3EF VT 3 6.351k 8401.56
For Ra 0 , Pin sin ' 4191.56 k sin '
Xs 10
EF ' ' VT 8401.5615.180 6351
' 14.180 Ia ' 281.573 38.620 A
jX s j10
New armature current is 281.573 A and new power factor is cos 38.620 = 0.7831 lag Ans.
Electrical Machines [EE/EEE] Answer Keys
Synchronous Machine Sheet - 05
357. B 358. C 359. D 360. B
361. B 362. D 363. A 364. A 365. B
366. B 367. B 368. B 369. B 370. A
371. C 372. A 373. D 374. A 375. A
376. C 377. B 378. D 379. A 380. A
381. C 382. B 383. D 384. C 385. 206
386. 0.999 387. 99.2 388. 838.2 389. 47.26 390. C
391. C 392. * 393. 91.827 394. 25, 26.3 395. 39, 0.387
41.8,
396. 397. B 398. B 399. B 400. A
0.767
401. C 402. A 403. D 404. B 405. 5687
406. 0.968 407. B 408. C 409. B 410. D
411. C 412. A 413. D 414. 0.8828 415. 0.819
416. A 417. D 418. B 419. D 420. A
421. C 422. D 423. C 424. B 425. B
426. C 427. B 428. D 429. B 430. 0.9163
431. 4.53 432. B 433. C 434. D 435. A
436. B 437. B 438. C 439. A 440. A
441. D 442. D 443. A 444. A 445. D
446. A 447. D 448. A 449. A 450. A
451. B 452. A 453. B 454. D 455. B
456. A 457. C 458. B 459. C 460. A
461. C 462. D 463. D 464. D 465. D
392. (242.9 V, 35.38 kW, 0.9845 lag)
358. (C)
EF VT 1.4 1
P sin 0.5 sin
Xs 1.2
25.40 T P
dT dP
T 1% P 1% 1%
d d
EF VT VT2 dQ EF VT
Q cos sin
Xs Xs d Xs
dP EF VT
cos
d Xs
dQ
tan tan 25.40 0.475
dP
dQ 0.475 1% 0.475%
387. (99.2)
100 k 480
Ia 120.3 A Vt 277.13 V
3 480 1 3
2 Synchronous Machine
E f (Vt I a Ra ) 2 ( I a X s ) 2 Unity p.f.
E f (277.13) 2 (120.3 1.5) 2 330.7 V
N1 P 300 6
f1 15 Hz
120 120
N 2 P 1000 6
f2 50 Hz
120 120
Ef 2 f2 15
Ef 2 330.7 99.2 V
Ef1 f1 50
422. (D)
VT 6600 / 3 3810.5 V
E F VT I a Z s 3810.5 (2.2 j 22) 8036.860 4962 17.76 0 V
Pin 3 3810.5 80 0.8 731.616 kW
Pout Pin 3I a 2 Ra Stray loss
Pout 731.616 3 80 2 2.2 3200 686.176 kW
686.176
93.8%
731.616
423. (C)
Pout 120
Pin 131.86 kW
0.91
131.86 k
Ia 190.32 A
3 500 0.8
The power converted from electrical to mechanical form is Pconverted Pin Pcu Pin 3 I a2 Ra
Pconv 131.86 k 3 190.32 2 0.08 123.16 kW 3(190) 2 (0.08) 8.66 kW
424. (B)
Pout 10 746 7460 W
Pin Pout Pl 7460 230 70 7760 W
Pout 7460
100 100 96.1%
Pin 7760
7760 230
Ia 19.48 A Vt 132.8 V
3 230 1 3
E F 132.8 j 5 19.480 0 164.7 36.250 V
425. (B)
VT 400 / 3 231 V I a 5000
EF VT jI a X s 240 15.70 15.70
Pin Pout no losses
Pelec Pmech VT I a cos constant
I a ' cos ' I a cos I a ' 0.8 50 1
I a ' 62.536.86 A 0
EF ' VT jI a ' X s 287.2 13.10 V
E F 240 V I F 0.9 A
E F ' 287.2 V I F 1.077 A
3 Synchronous Machine
426. (C)
6600 500 k
VT 3810.5 V Ia 43.74 A
3 3 6.6 k
( I a Z s ) 2 E F2 VT2 2 E F VT cos
(43.74 20) 2 E F2 3810.52 2 E F 3810.5 cos10 0
E F2 7505.22 E F 13754635.21 0
EF 4324.84 V EF VT Leading p.f.
EF 3180.38 V EF VT Lagging p.f.
EFL 7490.84 V Leading p.f.
EFL 5508.58 V Lagging p.f.
3EF VT
Lagging : Pmech sin 3VT I a cos Pelec
Xs
3 3180.38 3810.5
P sin100 315.66 kW
20
315.66 k
cos 0.631 lag
3 3810.5 43.74
427. (B)
3 4324.84 3810.5
P sin100 429.25 kW
20
429.25 k
cos 0.858 lead
3 3810.5 43.74
428. (D)
3EF VT EFL 6600
P sin 200 k sin 900
XS 20
EFL 606.06 V
429. (B)
VT 230 / 3 132.8 V
Z s 0.6 j 3 3.0678.7 0
E F VT I a Z s 132.8 (0.6 j 3) 100 0 130.3 13.31
0
With the field current unchanged, the load on the motor is increased till it draws 40 A from the supply.
( I a Z s ) 2 E F2 VT2 2 E F VT cos
(40 3.06) 2 132.82 130.32 2 132.8 130.3 cos
55.440
VT EF ' ' 132.8 130.3 55.440
Ia '
jX s 0.6 j3
I a ' 40 17.446 0 A cos 0.954 lag
Pout Pin 3 I a2 Ra 3 132.8 40 0.954 3 40 2 0.6 12.322 kW
Pout 12.322 k
Tdev 78.44 Nm
m 2 1500 / 60
4 Synchronous Machine
ESE Conventional Solutions
1. (1) Motor shaft output power, Pout 15 hp 15 746 W 11.19 kW
Motor input electrical power, Pin Pout PFWL Pcore L 11.19 1.5 1 13.69 kW
Pin 13.69 103
‐connected : VL VT 208 V Line current, I L = 47.5 A Ans.
3 VT cos 3 208 0.8
IL 47.5
Armature current per phase, I a 27.42 36.860 A cos 0.8 lead
3 3
Induced emf (line), E f VT jX s I a 208 0 0 j 2.5 27.4 36.86 0 255.05 12.410 V Ans.
(2) As the power on the shaft is increased to 30 hp, the shaft slows momentarily, and the internal generated
voltage E f swings act to a larger angle while maintaining a constant magnitude.
Motor shaft output power, Pout 30 hp 30 746 W 22.38 kW
Motor input electrical power, Pin Pout PFWL Pcore L 22.38 1.5 1 24.88 kW
3E f VT 3 255.05 208
Pin sin ' 24.88 103 sin ' ' 230
Xs 2.5
Line induced emf, E f 255.05 230 V Ans.
VT E f ' 20800 255.05 230
Armature current, I a ' 41.27 15.040 A
jX s j 2.5
Line current, I L 3I a 3 41.27 = 71.48 A and new power factor cos15.040 = 0.9657 lead Ans.
I a = 27.41Ð36.860 A I a = 27.41A
I a ' = 41.27 A
0 0 36.860 VT = 208Ð00
q = 36.86 VT = 208Ð0 A 15.040
12.410
d = 12.410 jX s I a = 68.55Ð126.860 230
E f = 255.05Ð - 12.410
E f = 255.05 Ð – 12.410 V
Phasor diagram (1) Phasor diagram (2) E f = 255.05Ð - 230
2. Industrial load : P1 4000 kW at cos 1 0.8 lag Q1 P1 tan 1 4000 tan[cos 1 0.8] 3000 kVAR
Output 1103.25
Synchronous motor : P2 1379.06 kW
Efficiency 0.8
Total active power of the system : PT P1 P2 4000 1379.06 5379.06 kW
Total power factor of the system : cos T 0.95 lag
Total reactive power of the system : QT PT tan T 5379.06 tan cos 1 0.95
So, QT Q1 Q2 1768 kVAR Q2 QT Q1 1768 3000 1232 kVAR
Synchronous motor kVA capacity : S2 P22 Q22 1397.062 12322 = 1849.22 kVA Ans.
5 Synchronous Machine
P2 1379.06
Power factor of synchronous motor : cos 2 = 0.7457 lead Ans.
S2 1849.22
Power factor is leading because of negative reactive power.
4. V‐curve and Inverted V‐curve