Rolling Stock Cables Catalog Overview

Caledonian & Addison is a manufacturer of copper and fiber optic cables established in 1978 with annual revenues exceeding $40 million. It has manufacturing facilities in the UK and China and sells products in over 35 countries. The company produces a wide range of rolling stock cables from 300V to 6kV meeting various international railway standards for underground, mass transit, and diesel/regional trains. It aims to meet new challenges in the industry through advanced technologies and a complete product range.

Uploaded by

two traveller
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
226 views102 pages

Rolling Stock Cables Catalog Overview

Caledonian & Addison is a manufacturer of copper and fiber optic cables established in 1978 with annual revenues exceeding $40 million. It has manufacturing facilities in the UK and China and sells products in over 35 countries. The company produces a wide range of rolling stock cables from 300V to 6kV meeting various international railway standards for underground, mass transit, and diesel/regional trains. It aims to meet new challenges in the industry through advanced technologies and a complete product range.

Uploaded by

two traveller
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 102

Rolling Stock Cables

www.caledonian-cables.co.uk
www.addison-cables.com
   Caledonian & Addison, established in 1978, produced a wide range of copper and fiber optic cables for
communication, power and electronics in its 2 plants in UK and 5 plants in China, with turnover exceeding USD
exceeding USD 40 million in Yr 2004. Caledonian products are sold in more than 35 countries around the globe.
Our extensive global network of manufacturing facilities gives us significant scale and the flexibility to fulfill
our customer requirements. This global presence provides design and consultancy solutions that are combined
with core cable manufacturing and logistics services, and vertically integrated with our E commerce technologies,
to optimize customer operations by lowering costs and reducing time to market.
Caledonian & Addison has been respected for its high standards of quality, excellent service level, competitive
pricing and a unique and innovative spirit. With our latest technologies, we are both inspired and well-positioned to
meet the changing needs of our customers. We have the resources to diversify and to enhance our product lines
and services. We understand the need for change and with our accurate planning we are ready for the future and
the promise of new marketing opportunities. Our tradition of growth through excellence is assured.
  

Our Design Centers work closely with customers to constantly improve its
standard range of products and technologies and to develop customized, country
and industry-specific solutions. Caledonian has established an extensive network
of design, manufacturing, and logistics facilities in the world's major markets to
serve the growing outsourcing needs of both multinational and regional customers.
Caledonian
Standard Wall power and control cables
> according to EN 50264

FIREROL FRL-SW-1SU / FRL-SW-3SU


0.6/1 or 1.8/3 kV - single core P10
FIREROL FRL-SW-3S / FRL-SW-6S
1.8/3 or 3.6/6 kV - sheathed single core P12
FIREROL FRL-SW-05M / FRL-SW-1M
300/500 V or 0.6/1 kV - multi-core P14
FIREROL FRL-SW-05M-OS / FRL-SW-1M-OS
300/500 V or 0.6/1 kV - multi-core screened P17

Medium Wall power and control cables


> according to EN 50264

FIREROL FRL-MW-1SU / FRL-MW-3SU


0.6/1 or 1.8/3 kV - single core P20
FIREROL FRL-MW-3S / FRL-MW-6S
1.8/3 or 3.6/6 kV - sheathed single core P22
FIREROL FRL-MW-05M / FRL-MW-1M
300/500 V or 0.6/1 kV - multi-core P24
FIREROL FRL-MW-05M-OS / FRL-MW-1M-OS
300/500 V or 0.6/1 kV - multi-core screened P27

Thin Wall instrumentation and control cables


> according to EN 50306

FIREROL FRL-TW-05SU
300/500 V - single core P30
FIREROL FRL-TW-05S-OS
300/500 V - single core screened P32
FIREROL FRL-TW-05M-OS
300/500 V - multi-core screened P34
FIREROL FRL-TW-05M-SW
300/500 V - multi-core with Standard Wall sheath P36
FIREROL FRL-TW-05M-ESW
300/500 V - multi-core with exposed Standard Wall sheath P38
FIREROL FRL-TW-05M-SW-OS
300/500 V - multi-core screened with Standard Wall sheath P40
FIREROL FRL-TW-05M-ESW-OS
300/500 V - multi-core screened with exposed Standard Wall sheath P42
FIREROL FRL-TW-05MP-SW-IOS
300/500 V - multipair screened with Standard Wall sheath P44
FIREROL FRL-TW-05MP-ESW-IOS
300/500 V - multipair screened with exposed Standard Wall sheath P46

High Temperature cables


> according to EN 50382
FIREROL FRL-HT-3SU/FRL-HT-6SU
1.8/3kV or 3.6/6kV – High Temperature Single Core Unsheathed cables P48
FIREROL FRL-HT-3S/FRL-HT-6S
1.8/3kV or 3.6/6kV - High Temperature Single Core Sheathed cables P50
FIREROL FRL-HT-6SURI
3.6/6kV - High Temperature Single core cables with Reinforced Insulation P52
Caledonian
Databus Cables
WTB (Wired Train Bus) Cables
FRA-WTB-02YCH-2C0.75S/FRA-WTB-02YSCH-1P0.75S P54
MVB(Multifunction Vehicle Bus)Cables
FRA-MVB-02YS(ST+C)H-1P0.5S+1C0.5S FRA-MVB-02YS(ST+C)H-2P0.5S P56
MVB(Multifunction Vehicle Bus)Cables(Redundant Version)
FRA-MVB-02YS(ST+C)H-1Q0.5S+4C0.25S P58
WTB(Wired Train Bus)/MVB(Multifunction Vehicle Bus)Cables
FRA-WTB/MVB-02YS(ST+C)H-1P20A P60
Integrated 9/11/18/20 Cores 0.75mm sq UIC Databus Cables P62
Category 5E Databus Cables
FRA-Cat5E-4C0.5S/FRA-Cat5E-4C22A FRA-Cat5E-4P22A P65
DATABUS RS 485 CABLE 300/500V P67

RSE/STD/024 PART 6 Rolling Stock Cables


RSE/STD/024 Part 6 Types IV Rolling Stock Cables
30/50V Singlecore Reduced Wall Unsheathed Cables P69
RSE/STD/024 Part 6 Types V Rolling Stock Cables
30/50V Singlecore Standard Wall Unsheathed Cables P70
RSE/STD/024 Part 6 Types VII Rolling Stock Cables
30/50V Multicore Standard Wall Cables P71
RSE/STD/024 Part 6 Types VIII Rolling Stock Cables
30/50V Multipair Screened Standard Wall Cables P72
RSE/STD/024 Part 6 Types IX Rolling Stock Cables
30/50V Multipair Reduced Wall Screened Cables P73
RSE/STD/024 Part 6 Types XII Rolling Stock Cables
300/500V Multicore Standard Wall Unsheathed Cables P74
RSE/STD/024 Part 6 Types XIII Rolling Stock Cables
300/500V Multicore Standard Wall Cables P75
RSE/STD/024 Part 6 Types I Rolling Stock Cables
600/1000V Multicore Reduced Wall Unsheathed Cables P76
RSE/STD/024 Part 6 Types II Rolling Stock Cables
600/1000V Multicore Standard Wall Unsheathed Cables P77
RSE/STD/024 Part 6 Types III Rolling Stock Cables
600/1000V Multicore Enhanced Wall Unsheathed Cables P79
RSE/STD/024 Part 6 Types VI Rolling Stock Cables
600/1000V Multicore Standard Wall Cables P80
RSE/STD/024 Part 6 Types XI Rolling Stock Cables
600/1000V Singlepair Reduced Wall Screened Cables P81

NF F 63-808 Rolling Stock Cables


NF F 63-808 Thin Wall Unsheathed Single Core 250V P82
NF F 63-808 Thin Wall Screened Single Core 250V P83
NF F 63-808 Thin Wall Screened Multicore P85

NF F 63-826 Rolling Stock Cables


NF F 63-826 Standard Wall Unsheathed Single Core 500V, 1000V, 1500V, 3000V P87
NF F 63-826 Standard Wall Sheathed Single Core 1500V, 3000V P89
NF F 63-826 Standard Wall Unscreened Multicore 500V P91
NF F 63-826 Extra-Flexible Standard Wall Unsheathed Single Core 1500V P93

NF F 63-827 Rolling Stock Cables


NF F 63-827 High Temperature Unsheathed Single Core 3000V P95
NF F 63-827 Extra-Flexible High Temperature Sheathed Single Core 3000V P97
Caledonian
Rolling Stock Cable
This catalog covers rolling stock for underground, mass transit lines and tramlines as well as diesel and regional trains. The increasing
need to reduce both volume and weight has lead to the development of miniaturized cables, as well as high temperature cables with
enhanced performance. This leads to highly stressed materials being used in the harsh environment of rolling stock. Caledonian &
Addison provides a full range of products from Medium Voltage to Instrumentation cables, and from Standard Wall, Medium Wall to Thin
Wall designs. The materials used have been specially developed to improve mechanical and thermal properties, fire performance and
extended life using advanced technologies, such as electron beam irradiation and silan.

New challenges in the rolling stock industry must be met due to long-awaited equipment
upgrades, booming freight traffic and high-speed train projects, and the growing need for
conventional subways, fully-automated metros,and light-rail suburban vehicles worldwide.
Caledonian & Addison manufactures a complete range of rolling stock cables and components, meeting national and international
standards, We supply wide range of rolling stock cables from 300V to 6kV in diameter of 0.5mm sq to 400mm sq covering diverse
railway standards. All cables meet strict technical requirements in terms of electrical safety, fire-performance (low-smoke and toxicity,
continuous operation in the event of fire).

As an OEM, Caledonian rolling stock cables provides our railway customers with future headroom by meeting the following European
Norms (EN) and international standards :
• EN 50264 European railway standard
• EN 50306 European railway standard
• BS 6853 British railway standard
• DIN 5510-2 German railway standard
• NF F 16 101 French railway standard
• UIC (International Union of Railways) 895

This catalog covers rolling stock for underground, mass transit lines and tramlines as well as diesel and regional trains. The increasing
need to reduce both volume and weight has lead to the development of miniaturized cables, as well as high temperature cables with
enhanced performance. This leads to highly stressed materials being used in the harsh environment of rolling stock. Caledonian
provides a full range of products from Medium Voltage to Instrumentation cables, and from Standard Wall, Medium Wall to Thin Wall
designs. The materials used have been specially developed to improve mechanical and thermal properties, fire performance and
extended life using advanced technologies, such as electron beam irradiation and silan.

CENELEC Standard
According to CENELEC Standards, railway rolling stock are designed to meet the following criticall requirements:
1) 2 levels of low temperature: -25°C and -40° C resistant
2) 2 levels of fluids resistance: oil resistant, or extra oil and fuel resistant
3) 3 levels of hazard: HL1. HL2-HL3. HL4
Low temperature, oil resistant (-25° C, IRM 902) A B C
Extra low temperature, oil resistant (-40° C, IRM 902) D E F
Low temperature, extra oil and fuel resistant (-25° C, IRM 902. IRM 903) G H J
Extra low temperature, extra oil and fuel resistant (-40° C, IRM 902. IRM 903) K L M
Extra low temperature, no oil and fuel resistant (-40° C) O O O
Caledonian Rolling Stock cables, branded as FIREROL, are mainly classified as follows:

EN 50264
Caledonian standard wall and medium wall rolling stock cables conform to EN 50264 for use in power cars, diesel-electric locomotives,
electric and diesel multiple units EMU / DMU, high-capacity rails, mono rail and light rail vehicles, sleeping cars and passenger coaches.
FIREROL are very flexible cables.
Application:
Strictly halogen free, these wires combine the advantages of small size, lightweight, high chemical resistance, high mechanical
properties. They are recommended for installation in railway vehicles (locomotives, trains, trolleybusses...).
A 120°C conductor temperature is allowed for a 20000 hours cumulative working time.
The external sheath is oil and diesel oil resistant, ozone and UV resistant
Conductors:
Flexible stranded tinned copper class 5 according to IEC 60228 with optional separator tape. Conductors temperature +90°/105° C
Standard:
EN 50264-1: General requirements applicable to cables, including detailed requirement for the insulating and sheathing materials

1
Caledonian
Standard Wall rolling stock cables having special fire performance
EN50264-2 = pr Standard wall single core cables with crosslinked elastomeric insulation
2 2
EN50264-2-1 0.6/1kV Unscreened, unsheathed 1mm -400mm FRL-SW-1SU
2 2
1.8/3kV Unscreened, unsheathed 1mm -400mm FRL-SW-3SU
2
1.8/3kV Unscreened, sheathed 1mmsq-400mm FRL-SW-3S
2
3.6/6kV Unscreened, sheathed 1mmsq-400mm FRL-SW-6S
EN50264-3 = pr Standard wall multi-core cables with crosslinked elastomeric insulation
2
EN50264-2-2 300/500V Unscreened or screened 1/1.5/2.5 mm ( 2-40 Cores) FRL-SW-05M / FRL-SW-05M-OS
2
0.6/1kV Unscreened or screened 1 mmsq-50 mm ( 2.3.4 cores) FRL-SW-1M / FRL-SW-1M-OS
Insulation Crosslinked halogen free rubber EI 101 (for A, B, C), EI 102 (for D, E, F), EI 103 (for G, H, J), EI 104 (for
compounds: K, L, M) and EI 105 (for O, EPDM compound)
Sheathing Special crosslinked halogen free black rubber type: EM 101 (for A, B, C), EM 102 (for D, E, F), EM 103
compounds: (for G, H, J), EM 104 (for K, L, M)
Medium Wall rolling stock cables having special fire performance
pr EN50264-3-1: Medium wall single core cable with crosslinked elastomeric insulation with reduced dimensions
2 2
0.6/1kV Unscreened, unsheathed 1mm -400mm FRL-MW-1SU
2 2
1.8/3kV Unscreened, unsheathed 1mm -400mm FRL-MW-3SU
2 2
1.8/3kV Unscreened, sheathed 1mm -400mm FRL-MW-3S
2 2
3.6/6kV Unscreened, sheathed 1mm -400mm FRL-MW-6S
pr EN50264-3-2: Medium wall multi-core cables with crosslinked elastomeric insulation with reduced dimensions
2
300/500V Unscreened or screened 1/1.5/2.5 mm ( 2-40 Cores) FRL-MW-05M / FRL-SW-05M-OS
2 2
0.6/1kV Unscreened or screened 1 mm -50 mm ( 2.3.4 cores ) FRL-MW-1M / FRL-SW-1M-OS
Insulation compounds: Crosslinked halogen free black rubber EI 106 (for A, B, C), EI 107 (for D, E, F), EI 108 (for G, H, J), EI
109 (for K, L, M) and EI 110 (for O, EPDM compound)
Sheathing compounds: Special crosslinked halogen free rubber type: EM 101 (for A, B, C), EM 102 (for D, E, F), EM 103 (for
G, H, J), EM 104 (for K, L, M)

EN 50306
Caledonian thin wall rolling stock cables conform to EN 50306 are resistant to chemicals, acids, oils, fuels and UV light. Anti-termite
cables and anti-rodent cables can also be offered upon customer request.
Application:
Strictly halogen free, these wires combine the advantages of small size, lightweight, high chemical resistance, high mechanical
properties. They are recommended for installation in railway vehicles (locomotives, trains, trolleybusses...).
A 120°C conductor temperature is allowed for a 20000 hours cumulative working time.
The external sheath is oil and diesel oil resistant, ozone and UV resistant
Conductors:
Flexible stranded tinned copper class 5 according to IEC 60228 with optional separator tape. Conductors temperature +90°/105° C or
+105°/125° C
Insulation: Crosslinked halogen free polyethylene or polymer
Sheathing: Cables sheathed with special S1 and S2 compounds (described in EN 50306-1) or EN 50264 sheathing compounds (EM
101. EM 102. EM 103 and EM 104)
Standard:
EN 50306-1: General requirements applicable to cables, including detailed requirement for the insulating and sheathing materials
Thin Wall rolling Thin wall single core cables
2 2
stock cables 300/500V Unscreened 0.5mm -2.5 mm FRL-TW-05SU
having special
fire
performanceEN
50306-2:
EN 50306-3: Thin wall single core and multi core cables (pairs, triads, and quads) screened
2 2
300/500V Screened 0.5mm -2.5 mm ( 1-4 Cores ) FRL-TW-05S-OS or FRL-TW-05M-OS
EN 50306-4: Thin wall multi-core and multi pair cables
2 2
Unscreened, sheathed for either exposed or protected wiring 0.5mm -2.5mm (2-48 Cores)
FRL-TW-05M-SW, FRL-TW-05M-ESW
2 2
Screened, sheathed for either exposed or protected wiring 0.5mm -2.5mm (2-8 Cores)
FRL-TW-05M-SW-OS, FRL-TW-05M-ESW-OS
2 2
Screened, sheathed for either exposed or protected wiring 0.5mm -1.5mm (2-7 Pairs/Cores)
FRL-TW-05MP-SW-IOS, FRL-TW-05MP-ESW-IOS

2
Caledonian
EN 50382
Caledonian High Temperature cable is characterized by its lightweight and small size which provide high flexibility and easy handling
required for high-speed train cable applications. High temperature cables implies higher current capacity for the same cross-section. The
higher the continuous temperature load, the longer the life time of the cable at a given working temperature. Caledonian High
Temperature cable allow greater safety margins and higher current capacity, with the following features:
• Low weight cable
• Low size cable
• Thin wall cable
• Wide operating temperature range (+125°C down to -60°C)
• Low smoke density (>90% light transmission)
• Short circuit cable and Earth fault-proof cables (>250°C)
Conductors:
For 120°C class : Flexible stranded tinned copper
For 150°C class : Flexible plain annealed copper
Class 5 (or class 6 on request) according to IEC 60228 with optional separator tape
Braiding:
Optional textile braid (for reinforced versions)
Insulation: Type EI 111 or EI 112 (if sheathed) cross-linked halogen free silicone rubber
Sheathing: Low temperature, oil resistant, ozone and UV resistant
For 120°C class : special cross-linked black rubber type EM106 according to EN 50382-1
For 150°C class : special cross-linked black silicone rubber type EM 107 according to EN 50382-1
Miniumum bending radius:
Dynamic use : 5 to 8 x outer diameter
Static use : 4 x outer diameter
Standard:
EN 50382-1: General requirements applicable to cables, including detailed requirement for the insulating and sheathing materials
High temperature rolling stock cables having special fire performance
EN 50382-2 Single core, silicon rubber insulated cables for +120° C and +150° C
2 2
1.8/3 kV unscreened, unsheathed with or without textile braid 1.5mm -400mm
FRL-HT-3SU
2 2
1.8/3 kV unscreened, sheathed with or without textile braid 1.5mm -400mm
FRL-TW-3S
2 2
3.6/6 kV unscreened, unsheathed with or without textile braid 2.5mm -400mm
FRL-TW-6SU
2 2
3.6/6 kV unscreened, sheathed with or without textile braid 2.5mm -400mm
FRL-TW-6S

Cable design in accordance with EN 50264 & EN 50306


Cable Make Up
Conductors
Tinned fine copper strands according to VDE 0295 / IEC 60228. class 5 are generally used for railway cables. For nominal cross section
of over 50mm sq, 0.41mm strand wire will be used instead of 0.51mm as stipulated in IEC 60228. The IEC 60228 Class 5 enhances
flexibility and the ease of handling, thus lengthening the product life of the cable. These class 5 class conductors are extremely flexible,
and easy-to-install in the compact rolling stock environment.
Insulation and outer sheath
Crosslinked polyolefine copolymer or EPR will generally be used for insulation whereas electron-beam cross-linked elastomer is
employed for sheathing. Cross-linked elastomer compounds offer very good durability that can resist heat, oil, vibration, chemical
aggression, etc
Electrical Characteristics
Nominal voltage
Nominal voltage of a cable refers to the reference voltage for which the cable is intended to be used. In EN 50264. applicable to power
cables, different voltage ranges ranging from 0.6/1 kV, 1.8/3 kV to 3.6/6 kV are defined. For each of these voltage ranges, specific
insulation thickness requirements are also stipulated in this standard. The operating voltage should not exceed the corresponding
maximum nominal voltage allowed.
Current Carrying Capacity
Current carrying capacity is defined as the amperage a conductor can carry before melting either the conductor or the insulation. There
are many factors which will limit the amount of current that can be passed through a wire. These major determining factors are:
Conductor Size:
The larger the circular mil area, the greater the current carrying capacity. The amount of heat generated should never exceed the
3
Caledonian
maximum temperature rating of the insulation
Ambient temperature:
The higher the ambient temperature, the less heat required to reach the maximum temperature rating of the insulation.
Conductor Number:
Heat dissipation is lessened as the number of individually insulated conductors, bundled together, is increased
Installation Conductors:
Restricting the heat dissipation by installing the conductors in conduit, duct, trays or raceways lessens the current carrying capacity. This
restriction can be alleviated somewhat by using proper ventilation methods, forced air cooling, etc.
According to EN 50343. “Railway applications - Rolling stock – Rules for installation of cabling” current carrying capacity are based on
maximum conductor temperatures of 90°C and 150°C defined in 3 b. The ambient temperature is 45°C. The following table shows the
current carrying capacities for a cable installed in mid air.
Current carrying capacity for cables in accordance with EN 50264
Nominal Current carrying capacity Current carrying capacity
cross section of Conductor temp. 90 °C (max) Conductor temp. 150 °C (max)
copper conductor
2
Ambient temp. 45 °C Ambient temp. 45 °C
mm I [A] I [A]
0.5 14 -
0.75 16 -
1 20 -
1.5 25 -
2.5 33 46
4 46 64
6 60 84
10 85 119
16 110 154
25 150 211
35 190 267
50 240 337
70 300 422
95 360 506
120 425 598
150 490 689
185 560 788
240 675 950
300 775 1091
400 950 1337
Ambient temperature
External conditions such as ambient temperature and bundling must be taken into account when
determining actual current carrying capacity. The following tables show the corresponding k1 modification factors depending on an
ambient temperature differing from 45 °C. Current carrying capacity decreases or increases depending on these factors
Maximum conductor temperature 90°C
Temperature °C 10 20 30 40 45 50 60 70
k1 1.33 1.25 1.15 1.05 1 0.94 0.82 0.66
Maximum conductor temperature 150°C
Temperature °C – 50 – 30 – 10 10 30 45 60 80 100 120
k1 1.38 1.3 1.23 1.15 1.06 1 0.92 0.81 0.69 0.53

Physical Characteristics
Temperatures and overload temperatures
EN 50264 defines two overload categories for cables at 90°C and 150°C : 160°C/50 h for 90°C and 250°C /50 h for 150°C. This means
that for a period of less than or equal to 50 hours, increased conductor temperatures can be withstood, while the operability of the cables
remains unimpaired. This has the advantage that short-time temperature increases can be identified and more serious damage such as
fires can be prevented.
Environmental conditions
Cables are suitable for fixed installation in rail vehicles up to – 40°C and are resistant to oil according to EN 50305. EN 60811-2-1. UIC
895 and resistant to fuel according to
EN 50305. EN 60811-2-1. UIC 895.
Fire Performance
EN 50264 and EN 50306 only describe cables and wires made from halogen free materials that minimise the risk of damage to persons
and property. These materials refer to hazard levels 1 – 4 as defined in EN 45545-1( fire protection on railway vehicles). These levels

4
Caledonian
define the degree of possibility of personal injury as the result of a fire. Amongst other things, they also form the basis of the
requirements for materials used in rail vehicles.
Halogen Free
The test is for determination of the amount of halogen acid gas, other than the hydrofluoric acid evolved during combustion of compound.
When tested in accordance with IEC 60754-1. the hydrochloric acid yield should be less than 0.5% (5mg/g) for LSOH compound.
Corrosivity
Corrosive gases produced in case of fire cause damage to vehicles and facilities and therefore should be avoided. According to EN
50267-2-2. a material is not corrosive if its combustion gases meet the stipulated target values for conductivity (≤10  s/mm) and pH
value (≥4.3).
This is equivalent to IEC 61034
Toxicity
In accordance with EN 50305- 9.2. or NFC-20454 a toxicity index (ITC) is calculated following analysis and titration of combustion gases.
The aforementioned hazard levels require that certain toxicity indices are not exceeded.
The toxicity indices for power cables listed in the following table are derived from EN 50264.
HL ITC
HL 1 not specified
HL 2 / HL 3 5 (max)
HL 4 3 (max)
The required toxicity indices for cables and wires, depending on hazard level, in accordance with EN 50306 (thin wall) are displayed in
the following table:
HL ITC
Insulation and sheath S1 EM101-104 and sheath S2

HL 1 not stipulated not stipulated


HL 2 / HL 3 10 (max) 5 (max)
HL 4 6 (max) 3 (max)
Toxic Fumes
Naval standard NES713 burns a set amount of material and analyses the gases given off. The volume of each gas is multiplied by the
toxicity index for each gas. The toxicity index for each gas are added together to give an overall toxicity index for the material. LFH
materials should have a toxicity index maximum of 10.
Flame Retardance
In accordance with EN 50265- 2-1 or IEC 60332-1. testing is carried out for a single insulated wire or cable. The specimen is deemed to
have passed this test, if after burning has ceased, the charred or affected position does not reach within 50mm of the lower edge of the
top clamp.
In accordance EN 50266-2-4. EN 50305 9.1 and IEC 60332-3. testing is carried out for bunched cables. A gas burner flame is applied to
the bottom of a vertically arranged conductor bundle in a test furnace. Following completion of the flame test, the specimen consisting of
3.5m, is deemed to have met the requirements, if after burning has ceased, the extent of charred of affected portion does not reach a
height exceeding 2.5m above the bottom edge of the burner
Smoke Density
For smoke density testing, the cube test is employed according to EN 50268-2-1 or IEC 61034. The 3 metre cube test measures the
generation of smoke from electric cables during fire. A light beam emitted from a window is projected across the enclosure of to a photo
cell connected to a recorder at the opposite window.
The recorder is adjusted to register from 0% for complete obscuration to 100% luminous transmission. A 1 metre cable sample is placed
in the centre of the enclosure and then subjected to fire. The minimum light transmission of the smoke is then measured.
The following table shows the minimum percentages of light transmission depending on hazard level:
HL Light transmission
HL 1 not specified
HL 2 / HL 3 60 %
HL 4 70 %
BS 6853.
In 1999. BS 6853 was introduced in UK and whose highest categories are probably the most demanding in the world. BS 6853 covers
both smoke emission testing and flammability testing. BS 6853 also introduced the concept of an R-Index, which is a single number
quantification of the toxic gas risk associated with candidate composite materials for use in railway rolling stock. The R-Indices are split
into the following categories:
Category 1a Trains which predominantly use tunnels R < 1.0
Category 1b Trains which use tunnels, but infrequently R < 1.6
Category 2 Trains which run, predominantly, overground R < 3.6

5
Caledonian
The R-Index is generated by analysing eight gases of combustion, for which critical concentrations have been established by
NIOSH/OSHA and reported as IDLH, (Immediately Dangerous to Life and Health), values.
Toxicity is the most important factor to address during the cable design. Toxicity limit for the UK and France are identical because both
require the same test method for elastomers (NF X 70-100). The only difference is that the U.K.'s specification requires an addendum for
nitrous oxides. Toxicity limits for French and the U.K. standards are developed from the IDLH values published in the National Institute
for Occupational Safety and Health (NIOSH) Guide. IDLH, or Immediately Dangerous to Life or Health, values are calculated based on
levels of gas in a particular atmosphere for 30 min that would pose an immediate riskthe U.K.'s BS 6853 specification is the most
stringent, closely followed by the French, and finally the U.S. It's important to note that Germany does not have a toxicity requirement.
R Index IDLH Values
3 3
U.K.(mg/m ) French (mg/m ) U.S. (ppm)
Gases
BS 6853 NF X 70-100 SMP 800C
CO 1.400 1.750 3.500
CO2 73.000 90.000 90.000
HCl 76 150 500
HBr 101 170 100
HCN 56 55 100
HF 25 17 100
NO/NO2 38 100
SO2 270 260 100
NFF 16-101/2
In France the French Railway’s standard NFF 16-101/2 combines reaction to fire, (M rating), with smoke and toxicity, (F rating), to
provide a true FST evaluation of the fire safe properties of a composite material.
As with the UK BS 6853 standard, the M/F rating required in NFF 16-101 is dependent on
the type of rolling stock, the extent to which it uses tunnels and the position and orientation of the composite part in the vehicle.
Test methods
The standard comprises the following test methods:
Flammability
NF-EN 60695-2 Glowing Wire at 850+/-15C and 960+/-15C
NF-EN ISO 4589-2 Oxygen index determination
Smoke Density
NFX 10-702 Smoke density determination
Toxicity
NFX 70-100 Pyrolysis and combustion gas analysis
M rating
M rating refers for the fire resistance classification of the materials to be used in the transportation industry
This classification rates the material in five categories

M0: incombustible
M1: non flammable
M2: burns with difficulty
M4: easily inflammable
M5: very easily inflammable

I/F rating
I/F rating refers to ignition resistance and fume classification of non metallic electrical components used in the underground
transporation industry.
Test description
1. Ignition
The ignition characteristics is determined by a combination of glow wire test (GWT) and oxygen index.
The material under test is categorized in the following tables:
Class Oxygen Index Glow Wire
I0 >70 No ignition at 960C
I1 >45 No ignition at 960C
I2 >32 No ignition at 850C
I3 >28 Ignition does not persist at 850C after glow wire is withdrawn
I4 >20
NC <70
(Not classified)
2. Fume composition
The parameters tested are fume opacity and analysis of pyrolysis as well as combustion gases.

6
Caledonian
All 3 parameters are used to calculate the smoke index ( SI) which in turns determines the fume class
F as follows:
F Class S.I Values
F0 ≤5
F1 ≤20
F2 ≤40
F3 ≤80
F4 ≤120
F5 >120

Classification
Each material will receive I/F rating, the smaller the number the better. Unfortunately, good I and good F are difficult to achieve: low I
values frequently means addition of fire retardant packages which in turns leads to high F values.

Consequently, 4 overall I/F performance classes are defined as follows:


I0 I1 I2 I3 I4 I5
F0 IV IV IV II I I
F1 IV IV IV II I I
F2 IV IV III II I I
F3 IV III III I I I
F4 IV III I I I I
F5 IV I I I I I

I Performance class 1. least demanding


II Performance class 2
III Performance class 3
IV Performance class 4. most demanding
DIN 5510
In Germany, the fire standards requirements in railways are defined by the DIN 5510. which does not include any measurement of toxic
gases but focuses only on reaction to fire and smoke produced in a fire scenario.
According to DIN5510. the test samples, vertically arranged in the test chimney, are stressed by a special bunsen burner for 3 minutes.
The combustibility, smoke release and dripping behaviour are then assessed.
The extent of destroyed surface area is decisive of the fire performance rating. The following are the fire performance classification:
Class
B1 Easily ignitable Damaged area 90%-100%
B2 Combustible Damaged area 76%-90%
B3 Difficult to ignite Damaged area <75%
B4 Incombustible No damage
The rating with respect to burning dripping are also observed in the chimney test. Differentiation between the classes is based on visual
observation by T1 burning dripping to T4 no visible deformation/ no softening.
The smoke release during the chimney test will be done by the reduced transmission value. Two classes, SR1 10% min and SR2 < 50%
min are used.
EN 45545
En 45545 is a common new EU standard is to replace the existing national regulations for fire safety in trains and track-guided vehicles.
This new standard constitutes a harmonising of the existing national standards based on the highest common denominator – and will
therefore represent a stiffening of the fire safety regulations applied in the individual countries.
The new standard divides railway vehicles into four operation categories. As seen below, it particularly targets safety in connection with
tunnels and bridges:
Category Services Infrastructure
1 Mainline, regional, urban and Operation not determined by underground sections, tunnels and/or
suburban elevated structures
2 Urban and suburban Operation determined by underground sections, tunnels and/or
elevated structures with walkways or other means for safe side
evacuation from the vehicles
3 Mainline and regional Operation determined by underground sections, tunnels and/or
elevated structures with walkways or other means for safe side
evacuation from the vehicles
4 Mainline, regional, urban and Mainline, regional, urban and suburban operation determined by
suburban underground sections, tunnels and/or elevated structures without any
means for safe side evacuation from the vehicles

7
Caledonian
The standard also establishes four hazard levels that determine the requirements for protection against fire and smoke formation. Most
new railway vehicles will be designed to hazard level 3. but some vehicles, for example for light rail systems, will have to conform to
hazard level 4.:

Category Design category


Standard vehicles Automatic vehicles Double-decked vehicles Sleeping cars
1 HL 2 HL 2 HL 2 HL 2
2 HL 2 HL 3 HL 3 N/A
3 HL 3 HL 4 HL 3 HL 4
4 HL 4 HL 4 HL 4 HL 4
HL 1 Long distance train

HL2 Regional train without tunnel

HL3 High speed trains


City and regional trains
Trams with party going through tunnels.

HL4 Metro
Night train with sleeping coaches

Ordering Code

FRL-A-BC-D-E-F-G
A- Wall Type
SW- Standard Wall
MW- Medium Wall
TW- Thin Wall
HT- High Temperature
B- Voltage Type
05-300/500V
06-0.6/1KV
3-1.8/3KV
6-3.6/6KV
C- Core Type
S- Single Core
M-Multi Core
MP-Multi Pair
D-Insulation or Sheath Type
U-Unsheathed
SW-Standard Wall Sheath
ESW-Exposed Standard Wall Sheath
RI-Reinforced Insulation
E- Screen Type
OS-Overall Screen
IOS-Individual & Overall Screen
F-Number of Cores and Pairs
10C- 10 Cores
G- Cross Section Areas
1.5- 1.5mm2

8
Caledonian
Test Method

EN 50305
Test Methods
Special test are stipulated in EN 50305 for each European railway rolling stock. Below is the test method for the rolling stock cables to
En 50264 and EN 50306 and EN 50382 :
For Standard Wall and Medium Wall cables according to EN 50264
Ageing test at: +120° C
Fluid Resistance: IRM 902 for mineral oil resistance
IRM 903 for fuel resistance
N oxalic acid
N sodium hydroxide
Test at low temperature: -25° C or -40° C
Fire Propagation: Single core test EN 50265-2-1 (IEC 60332-1)
Bundle core test EN 50266-2-4 (IEC 60332-3C) + EN 50305
Toxicity Test: Toxicity EN 50305
Smoke Density Test: Low smoke EN 50268-2 (IEC 61034)
Halogen Test: acid and toxic gases EN 50267-2-1/8-2-2 (IEC 60754-1&2)
Electrical Test: Dielectric test and direct current stability test at +85° C

For Thin Wall cables according to EN 50306


Standard Wall tests plus
Long Term Ageing Test: (20.000 h at +125° C) EN 50305
Notch Propagation Test: EN 50305
Abrasion Test: EN 50305

For High Temperature cables according to EN 50382


Standard Wall tests plus
Ageing Test for silicon insulation at +200° C and long term sheath ageing test (20.000 h
at +140° C)

Flexible Anti-UV Fire Retardant Low Fire Load

Anti-Weather Anti-Oil Impact Resistant Low Smoke

9
Caledonian
FIREROL Standard Wall
Single Core Unsheathed
0.6/1 kV or 1.8/3 kV
to EN 50264-2-1 (FRL-SW-1SU, FRL-SW-3SU)

A. Conductor B. Insulation
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and
installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction
Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 101 to EI 104)

Electrical & Mechanical Properties


Nominal Voltage 0.6/1 kV or 1.8/3 kV
Maximum Conductor Temperature +90 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

10
Caledonian
FRL-SW-1SU 0.6/1 kV

MIN. MEAN OVERALL CONDUCTOR INSULATION INSULATION


NOMINAL CONDUCTOR THICKNESS DIAMETER RESISTANCE RESISTANCE RESISTANCE
CROSS-SECTIONAL DIAMETER OF WEIGHT AT 20°C AT 20°C AT 90°C
AREA (a) INSULATION
min max max min min
2
mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km
1.0 1.25 0.8 2.8 3.2 18 20 65 0.65
1.5 1.5 0.8 3.0 3.5 20 13.7 55 0.55
2.5 1.95 0.8 3.4 3.9 30 8.21 50 0.5
4.0 2.5 0.8 3.9 4.6 50 5.09 40 0.4
6.0 3.0 0.9 4.6 5.4 70 3.39 35 0.35
10 3.9 1.1 5.8 6.8 130 1.95 30 0.3
16 5.0 1.1 7.2 8.5 170 1.24 30 0.3
25 6.4 1.3 8.6 10 260 0.795 30 0.3
35 7.7 1.3 10.2 11.5 350 0.565 25 0.25
50 9.2 1.5 11.6 13.5 500 0.393 25 0.25
70 11.0 1.5 13.3 15.5 690 0.277 20 0.2
95 12.5 1.6 14.9 17.4 910 0.210 20 0.2
120 14.2 1.6 16.5 19.3 1120 0.164 20 0.2
150 15.8 1.9 18.5 21.7 1430 0.132 15 0.15
185 17.5 1.9 20.1 23.6 1720 0.108 15 0.15
240 20.1 2.1 22.9 26.8 2290 0.0817 15 0.15
300 22.5 2.2 25.4 29.7 2810 0.0654 10 0.1
400 25.8 2.3 28.7 33.6 2690 0.0495 10 0.1
(a) = for information, indicative only
FRL-SW-3SU 1.8/3 kV
RESISTANCE INSULATION INSULATION
NOMINAL CONDUCTOR MIN. MEAN OVERALL OF RESISTANCE RESISTANCE
CROSS-SECTIONAL DIAMETER THICKNESS DIAMETER WEIGHT CONDUCTOR AT 20°C AT90°C
AREA (a) OF AT 20°C
INSULATION min max max min min
2
mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km
1.5 1.5 2.5 6.2 7.3 70 13.7 120 1.2
2.5 1.95 2.5 6.6 7.8 90 8.21 100 1.0
4.0 2.5 2.5 7.1 8.4 110 5.09 90 0.9
6.0 3.0 2.5 7.6 8.9 130 3.39 80 0.8
10 3.9 2.5 8.4 9.9 190 1.95 65 0.65
16 5.0 2.5 9.5 11.1 250 1.24 50 0.55
25 6.4 2.5 10.8 12.7 330 0.795 45 0.45
35 7.7 2.5 12.0 14.1 430 0.565 40 0.4
50 9.2 2.5 13.4 15.7 570 0.393 35 0.35
70 11.0 2.5 15.1 17.7 760 0.277 30 0.3
95 12.5 2.7 16.9 19.8 980 0.210 30 0.3
120 14.2 2.7 18.5 21.7 1210 0.164 25 0.25
150 15.8 2.7 20.0 23.4 1500 0.132 20 0.2
185 17.5 2.7 21.6 25.3 1800 0.108 20 0.2
240 20.1 2.7 24.1 28.2 2360 0.0817 20 0.2
300 22.5 2.7 26.3 30.8 2840 0.0654 15 0.15
400 25.8 2.9 29.8 34.9 3800 0.0495 15 0.15

(a) = for information, indicative only

11
Caledonian
FIREROL Standard Wall
Single Core Sheathed
1.8/3 kV or 3.6/6 kV
to EN 50264-2-1 (FRL-SW-3S / FRL-SW-6S)

A. Conductor B. Insulation C. Sheath


Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and
installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 101 to EI 104)
Sheath
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104)
Electrical & Mechanical Properties
Nominal Voltage 1.8/3 kV or 3.6/6 kV
Maximum Conductor Temperature +90 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

12
Caledonian
FRL-SW-3S 1.8/3 kV

CONDUCTOR INSULATION INSULATION


NOMINAL MIN. MEAN MIN. MEAN OVERALL
CONDUCTOR RESISTANCE RESISTANCE RESISTANCE
CROSS-SECTIONAL THICKNESS OF THICKNESS DIAMETER WEIGHT
DIAMETER (a) AT 20°C AT 20°C AT 90°C
AREA INSULATION OF SHEATH

min max max min min


2
mm mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km
1.5 1.5 1.3 1.4 6.7 7.8 80 13.7 960 9.6
2.5 1.95 1.3 1.4 7.1 8.3 100 8.21 850 8.5
4.0 2.5 1.3 1.4 7.6 8.9 120 5.09 750 7.5
6.0 3.0 1.3 1.4 8.1 9.5 140 3.39 670 6.7
10 3.9 2.2 1.4 10.6 12.4 250 1.95 550 5.5
16 5.0 2.2 1.4 11.7 13.6 310 1.24 450 4.5
25 6.4 2.2 1.4 13.0 15.2 410 0.795 390 3.9
35 7.7 2.2 1.4 14.2 16.6 520 0.565 350 3.5
50 9.2 2.2 1.4 15.6 18.3 660 0.393 300 3.0
70 11.0 2.2 1.5 17.5 20.5 880 0.277 260 2.6
95 12.5 2.4 1.6 19.6 22.3 1130 0.210 250 2.5
120 14.2 2.4 1.6 21.1 24.6 1370 0.164 220 2.2
150 15.8 2.4 1.7 22.7 26.6 1690 0.132 210 2.1
185 17.5 2.4 1.7 24.0 28.1 2000 0.108 200 2.0
240 20.1 2.4 1.8 27.0 31.6 2620 0.0817 180 1.8
300 22.5 2.4 1.9 29.4 34.4 3140 0.0654 170 1.7
400 25.8 2.6 2.0 32.7 38.3 4140 0.0495 150 1.5
FRL-SW-6S 3/6 kV
MIN. MEAN CONDUCTOR INSULATION INSULATION
NOMINAL MIN. MEAN OVERALL
CONDUCTOR THICKNESS RESISTANCE RESISTANCE RESISTANCE
CROSS-SECTIONAL THICKNESS DIAMETER WEIGHT
DIAMETER (a) OF AT 20°C AT 20°C AT 90°C
AREA OF SHEATH
INSULATION min max max min min
2
mm mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km
2.5 1.95 3.0 1.4 10.5 12.3 170 8.21 1300 13
4.0 2.5 3.0 1.4 11.0 12.9 190 5.09 1150 11.5
6.0 3.0 3.0 1.4 11.5 13.4 230 3.39 1050 10.5
10 3.9 3.0 1.4 12.3 14.4 300 1.95 850 8.5
16 5.0 3.0 1.4 13.3 15.6 360 1.24 710 7.1
25 6.4 3.0 1.4 14.7 17.2 450 0.795 630 6.3
35 7.7 3.0 1.4 15.9 18.6 560 0.565 550 5.5
50 9.2 3.0 1.5 17.5 20.5 720 0.393 500 5.0
70 11.0 3.0 1.5 19.2 22.4 930 0.277 430 4.3
95 12.5 3.0 1.6 20.8 24.3 1160 0.210 400 4.0
120 14.2 3.1 1.7 22.7 26.6 1430 0.164 360 3.6
150 15.8 3.1 1.7 24.2 28.4 1740 0.132 340 3.4
185 17.5 3.2 1.8 26.2 30.7 2080 0.108 330 3.3
240 20.1 3.4 1.9 29.2 34.2 2730 0.0817 300 3.0
300 22.5 3.4 1.9 31.5 36.9 3230 0.0654 250 2.5
400 25.8 3.4 2.0 34.8 40.7 4210 0.0495 230 2.3
(a)= for information, indicative only

13
Caledonian
FIREROL Standard Wall
Multi Core Unscreened
300/500 V or 0.6/1 kV
to EN 50264-2-2 (FRL-SW–05M / FRL-SW-1M)

A. Conductor B. Insulation C. Sheath


Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and
installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 101 to EI 105)
Outer sheath
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104)
Electrical & Mechanical Properties
Nominal Voltage 300/500 V or 0.6/1 kV
Maximum Conductor Temperature +90 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

14
Caledonian
FRL-SW-05M 300/500 V

NUMBER INSULATION INSULATION


AND MIN. MEAN OVERALL CONDUCTOR RESISTANCE RESISTANCE
MAX WIRE MIN. MEAN DIAMETER RESISTANCE AT 20°C AT 90°C
NOMINAL CONDUCTOR THICKNESS DIAMETER
DIAMETER THICKNESS UNSREENED WEIGHT AT 20°C
CROSS DIAMETER (b) OF OF CORE (b)
OF SCREEN OF SHEATH
SECTIONAL INSULATION EI 105 EI 101- EI 104
AREA (a)
min max max min min
2
n x mm mm mm mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km

2x1 1.2 0.6 2.6 0.16 1.4 7.2 8.5 100 20.0 140 70

4x1 0.6 2.6 0.16 1.4 8.2 9.6 130 20.0 140 70

7x1 0.6 2.6 0.16 1.4 9.6 11.2 180 20.0 140 70

9x1 0.6 2.6 0.21 1.4 11.5 13.4 220 20.0 140 70

12x1 0.6 2.6 0.21 1.4 12.3 14.4 280 20.0 140 70

19x1 1.25 0.6 2.6 0.26 1.4 14.5 16.6 400 20.0 140 70

24x1 0.6 2.6 0.26 1.5 16.7 19.6 530 20.0 140 70

32x1 0.6 2.6 0.26 1.6 18.5 21.7 660 20.0 140 70

37x1 0.6 2.6 0.26 1.6 19.2 22.4 720 20.0 140 70

40x1 0.6 2.6 0.26 1.6 19.9 23.3 750 20.0 140 70

4x1.5 0.7 3.0 0.16 1.4 9.2 10.8 170 13.7 120 60

7x1.5 0.7 3.0 0.21 1.4 10.9 12.8 250 13.7 120 60

9x1.5 0.7 3.0 0.21 1.4 13.1 15.3 310 13.7 120 60

12x1.5 0.7 3.0 0.21 1.4 14.0 16.4 400 13.7 120 60
1.5
19x1.5 0.7 3.0 0.26 1.5 16.5 19.4 570 13.7 120 60

24x1.5 0.7 3.0 0.26 1.6 19.5 22.8 760 13.7 120 60

32x1.5 0.7 3.0 0.26 1.7 21.5 25.2 940 13.7 120 60

37x1.5 0.7 3.0 0.26 1.7 22.4 26.2 1040 13.7 120 60

4x2.5 0.8 3.7 0.21 1.4 10.7 12.5 240 8.21 90 45

7x2.5 0.8 3.7 0.21 1.4 12.7 14.9 360 8.21 90 45

9x2.5 0.8 3.7 0.26 1.5 15.6 18.3 450 8.21 90 45


1.95
12x2.5 0.8 3.7 0.26 1.5 16.7 19.6 590 8.21 90 45

19x2.5 0.8 3.7 0.26 1.6 19.7 23.1 860 8.21 90 45

24x2.5 0.8 3.7 0.26 1.8 23.5 27.5 1150 8.21 90 45

(a)= One earth conductor (green/yellow) can be included upon request


(b)= For information,indicative only

15
Caledonian
FRL-SW-1M 0.6/1 kV
NUMBER CONDUCTOR INSULATION INSULATION
AND MIN. MEAN OVERALL RESISTANCE RESISTANCE RESISTANCE
CORE CORE MIN. MEAN
NOMINAL CONDUCTOR THICKNESS DIAMETER AT AT +20°C AT +20°C
DIAMETER DIAMETER THICKNESS WEIGHT
CROSS DIAMETER (a) OF +20°C EI 105 EI 101-EI 104
MIN.(mm) MAX.(mm) OF SHEATH
SECTIONAL INSULATION
AREA (a) min max max min min
2
n x mm mm mm mm mm mm mm mm kg/km mm Ω/km MΩ·km

TWO CORES

1.5 1.5 0.8 3.0 3.5 1.4 8.5 9.9 140 13.7 150 75

2.5 1.95 0.8 3.4 3.9 1.4 9.3 10.9 180 8.21 130 65

4 2.5 0.8 3.9 4.6 1.4 10.3 12.1 230 5.09 110 55

6 3.0 0.9 4.6 5.4 1.4 11.8 13.9 300 3.39 90 45

10 3.9 1.1 5.8 6.8 1.4 14.3 16.7 480 1.95 85 45

16 5.0 1.1 7.2 8.5 1.5 16.5 19.4 630 1.24 70 35

25 6.4 1.3 8.6 10.0 1.6 20.1 23.5 920 0.795 65 35

35 7.7 1.3 10.2 11.5 1.7 22.7 26.6 1200 0.565 60 30

50 9.2 1.5 11.6 13.5 1.9 26.7 31.2 1670 0.393 55 30

THREE CORES

1.5 1.5 0.8 3.0 3.5 1.4 8.9 10.5 160 13.7 150 75

2.5 1.95 0.8 3.4 3.9 1.4 9.9 11.6 210 8.21 130 65

4 2.5 0.8 3.9 4.6 1.4 11.0 12.9 270 5.09 110 55

6 3.0 0.9 4.6 5.4 1.4 12.5 14.6 360 3.39 90 45

10 3.9 1.1 5.8 6.8 1.5 15.3 17.9 600 1.95 85 45

16 5.0 1.1 7.2 8.5 1.6 17.8 20.8 790 1.24 70 35

25 6.4 1.3 8.6 10.0 1.7 21.6 25.3 1170 0.795 65 35

35 7.7 1.3 10.2 11.5 1.8 24.4 28.6 1530 0.565 60 30

50 9.2 1.5 11.6 13.5 1.9 28.2 33.3 2120 0.393 55 30

FOUR CORES

1.5 1.5 0.8 3.0 3.5 1.4 9.7 11.3 190 13.7 150 75

2.5 1.95 0.8 3.4 3.9 1.4 10.7 12.5 250 8.21 130 65

4 2.5 0.8 3.9 4.6 1.4 11.9 14.0 330 5.09 110 55

6 3.0 0.9 4.6 5.4 1.4 13.7 16.1 450 3.39 90 45


10 3.9 1.1 5.8 6.8 1.5 16.9 19.8 740 1.95 85 45

16 5.0 1.1 7.2 8.5 1.6 19.6 22.9 980 1.24 70 35

25 6.4 1.3 8.6 10.0 1.8 24.1 28.2 1460 0.795 65 35

3X35+25 7.7/6.4 1.3/1.3 10.2/8.6 11.5/10.0 1.9 28.5 34.2 1610 0.565/0.795 60 30

3X50+25 9.2/6.4 1.5/1.3 11.6/8.6 13.5/10.0 2.0 33.4 40.0 2230 0.393/0.795 55 30

(a)= For information,indicative only

16
Caledonian
FIREROL Standard Wall
Multi Core Overall Screened
300/500 V or 0.6/1 kV
to EN 50264-2-2 (FRL-SW-05M-OS / FRL-SW-1M-OS)

A. Conductor B. Insulation C. Screen D. Sheath


Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and
installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 101 to EI 105)
Overal screen
Tinned annealed copper wires
Outer sheath
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104)
Electrical & Mechanical Properties
Nominal Voltage 300/500 V or 0.6/1 kV
Maximum Conductor Temperature +90 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

17
Caledonian
FRL-SW-05M-OS 300/500 V
NUMBER INSULATION INSULATION
AND MIN. MEAN MIN. MEAN OVERALL CONDUCTOR RESISTANCE RESISTANCE
DIAMETER MAX WIRE DIAMETER RESISTANCE AT 20°C AT 20°C
NOMINAL CONDUCTOR THICKNESS THICKNESS
OF CORE DIAMETER SCREENED WEIGHT AT 20°C
CROSS DIAMETER (b) OF OF SHEATH
(b) OF SCREEN EI 105 EI 101-EI 104
SECTIONAL INSULATION (SCREENED)
AREA (a)
min max max min min
2
n x mm mm mm mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km

2x1 0.6 2.6 0.16 1.4 8.1 9.5 110 20.0 140 70

4x1 0.6 2.6 0.16 1.4 9.0 10.6 150 20.0 140 70

7x1 0.6 2.6 0.16 1.4 10.4 12.2 210 20.0 140 70

9x1 0.6 2.6 0.21 1.4 12.5 14.6 290 20.0 140 70

12x1 0.6 2.6 0.21 1.4 13.3 15.6 330 20.0 140 70
1.25
19x1 0.6 2.6 0.26 1.5 15.7 18.4 490 20.0 140 70

24x1 0.6 2.6 0.26 1.6 18.1 21.2 630 20.0 140 70

32x1 0.6 2.6 0.26 1.6 19.7 23.1 760 20.0 140 70

37x1 0.6 2.6 0.26 1.7 20.7 24.2 840 20.0 140 70

40x1 0.6 2.6 0.26 1.7 21.4 25.1 910 20.0 140 70

4x1.5 0.7 3.0 0.16 1.4 10.1 11.8 200 13.7 120 60

7x1.5 0.7 3.0 0.21 1.4 11.9 14.0 290 13.7 120 60

9x1.5 0.7 3.0 0.21 1.4 14.1 16.5 380 13.7 120 60

12x1.5 0.7 3.0 0.21 1.5 15.8 18.5 450 13.7 120 60
1.5
19x1.5 0.7 3.0 0.26 1.5 17.8 20.8 660 13.7 120 60

24x1.5 0.7 3.0 0.26 1.6 20.7 24.2 850 13.7 120 60

32x1.5 0.7 3.0 0.26 1.7 22.7 26.6 1050 13.7 120 60

37x1.5 0.7 3.0 0.26 1.7 23.6 27.6 1160 13.7 120 60

4x2.5 0.8 3.7 0.21 1.4 11.8 13.9 280 8.21 90 45

7x2.5 0.8 3.7 0.21 1.4 13.7 16.1 400 8.21 90 45

9x2.5 0.8 3.7 0.26 1.5 16.8 19.7 560 8.21 90 45


1.95
12x2.5 0.8 3.7 0.26 1.5 18.0 21.1 660 8.21 90 45
19x2.5 0.8 3.7 0.26 1.6 21.1 24.6 950 8.21 90 45

24x2.5 0.8 3.7 0.26 1.8 24.7 28.9 1260 8.21 90 45

(a)= One earth conductor (green/yellow) can be included upon request


(b)= For information,indicative only

18
Caledonian

FRL-SW-1M-OS 0.6/1 kV
NUMBER INSULATION INSULATION
AND MIN. MEAN MIN. MIN. CONDUCTOR
CORE CORE OVERALL RESISTANCE RESISTANCE
NOMINAL CONDUCTOR THICKNESS SCREEN AVERAGE DIAMETER RESISTANCE
DIAMETER DIAMETER WEIGHT AT +20°C AT +20°C
CROSS DIAMETER (a) OF WIRE SHEATH AT +20°C
MIN.(mm) MAX.(mm) EI 105 EI 101-EI 104
SECTIONAL INSULATION DIAMETER THICKNESS
AREA (a) min max max min min

N x mm2 mm mm mm mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km

TWO CORES

1.5 1.5 0.8 3.0 3.5 0.16 1.4 9.3 10.9 150 13.7 150 75

2.5 1.95 0.8 3.4 3.9 0.16 1.4 10.2 11.9 180 8.21 130 65

4 2.5 0.8 3.9 4.6 0.21 1.4 11.5 13.4 240 5.09 110 55

6 3.0 0.9 4.6 5.4 0.21 1.4 12.9 15.1 300 3.39 90 45

10 3.9 1.1 5.8 6.8 0.21 1.5 15.5 18.2 460 1.95 85 45

16 5.0 1.1 7.2 8.5 0.26 1.5 17.9 20.9 610 1.24 70 35

25 6.4 1.3 8.6 10.0 0.26 1.7 21.6 25.3 830 0.795 65 35

35 7.7 1.3 10.2 11.5 0.31 1.8 24.4 28.6 1130 0.565 60 30

50 9.2 1.5 11.6 13.5 0.31 1.9 28.2 33.0 1500 0.393 55 30

THREE CORES

1.5 1.5 0.8 3.0 3.5 0.16 1.4 9.8 11.4 180 13.7 150 75

2.5 1.95 0.8 3.4 3.9 0.16 1.4 10.7 12.5 220 8.21 130 65

4 2.5 0.8 3.9 4.6 0.21 1.4 12.0 14.1 300 5.09 110 55

6 3.0 0.9 4.6 5.4 0.21 1.4 13.6 16.0 380 3.39 90 45

10 3.9 1.1 5.8 6.8 0.26 1.5 16.7 19.6 620 1.95 85 45

16 5.0 1.1 7.2 8.5 0.26 1.6 19.1 22.3 800 1.24 70 35

25 6.4 1.3 8.6 10.0 0.26 1.7 22.9 26.8 1140 0.795 65 35

35 7.7 1.3 10.2 11.5 0.31 1.8 26.0 30.5 1500 0.565 60 30

50 9.2 1.5 11.6 13.5 0.31 2.0 30.3 35.4 2050 0.393 55 30
FOUR CORES
1.5 1.5 0.8 3.0 3.5 0.16 1.4 10.5 12.3 210 13.7 150 75

2.5 1.95 0.8 3.4 3.9 0.21 1.4 11.8 13.9 280 8.21 130 65

4 2.5 0.8 3.9 4.6 0.21 1.4 13.1 15.3 360 5.09 110 55

6 3.0 0.9 4.6 5.4 0.21 1.4 14.9 17.4 470 3.39 90 45

10 3.9 1.1 5.8 6.8 0.26 1.6 18.4 21.6 780 1.95 85 45

16 5.0 1.1 7.2 8.5 0.26 1.7 21.1 24.6 1020 1.24 70 35

25 6.4 1.3 8.6 10.0 0.31 1.8 25.6 29.9 1490 0.795 65 35
3X35+25 7.7/6.4 1.3/1.3 10.2/8.6 11.5/10.0 0.31 1.9 30.0 35.1 1820 0.565/0.795 60 30

3X50+25 9.2/6.4 1.5/1.3 11.6/8.6 13.5/10.0 0.31 2.1 34.9 40.8 2480 0.393/0.795 55 30

(a)= For information,indicative only

19
Caledonian
FIREROL Medium Wall
Single Core Unsheathed
0.6/1 kV or 1.8/3 kV
to EN 50264-3-1 (FRL-MW-1SU / FRL-MW-3SU)

A. Conductor B. Insulation
Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and
installation cost are an important factor.
-Used in control,l auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 109)
Electrical & Mechanical Properties
Nominal Voltage 0.6/1 kV or 1.8/3 kV
Maximum Conductor Temperature +90 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

20
Caledonian
FRL-MW-1SU 0.6/1 kV

NOMINAL MIN. MEAN CONDUCTOR INSULATION INSULATION


CONDUCTOR OVERALL OVERALL RESISTANCE RESISTANCE RESISTANCE
CROSS-SECTIONAL THICKNESS WEIGHT
AREA DIAMETER (a) OF DIAMETER DIAMETER AT +20°C AT +20°C AT +90°C
(a) INSULATION MIN.(mm) MAX.(mm)
max min min
2
mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km
1.0 1.25 0.6 2.4 2.8 10 20 11.4 0.114
1.5 1.5 0.7 2.8 3.3 20 13.7 11.0 0.110
2.5 1.95 0.7 3.2 3.8 30 8.21 9.1 0.091
4 2.5 0.7 3.8 4.4 50 5.09 7.5 0.075
6 3.0 0.7 4.2 5.0 60 3.39 6.5 0.065
10 3.9 0.7 5.1 5.9 110 1.95 5.2 0.052
16 5.0 0.7 6.1 7.2 160 1.24 4.2 0.042
25 6.4 0.9 7.8 9.1 240 0.795 4.1 0.041
35 7.7 0.9 9.0 10.6 330 0.565 3.5 0.035
50 9.2 1.0 10.6 12.4 460 0.393 3.3 0.033
70 11.0 1.1 12.5 14.6 660 0.277 3.0 0.030
95 12.5 1.1 13.9 16.3 860 0.210 2.7 0.027
120 14.2 1.2 15.7 18.4 1080 0.164 2.7 0.027
150 15.8 1.4 17.6 20.6 1370 0.132 2.7 0.027
185 17.5 1.6 19.6 22.9 1690 0.108 2.6 0.026
240 20.1 1.7 22.2 26.0 2230 0.0817 2.6 0.026
300 22.5 1.8 24.6 28.8 2780 0.0654 2.4 0.024
400 25.8 2.0 28.1 32.9 3740 0.0495 2.4 0.024

FRL-MW-3SU 1.8/3 kV

NOMINAL MIN. MEAN CONDUCTOR INSULATION INSULATION


CROSS-SECTIONAL CONDUCTOR THICKNESS OVERALL OVERALL RESISTANCE RESISTANCE RESISTANCE
AREA DIAMETER (a) OF DIAMETER DIAMETER WEIGHT AT +20°C AT +20°C AT +90°C
MIN.(mm) MAX.(mm)
(a) INSULATION
max min min
2
mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km
1.5 1.5 2.0 5.3 6.2 50 13.7 21.0 0.210
2.5 1.95 2.0 5.7 6.7 60 8.21 18.0 0.180
4 2.5 2.0 6.2 7.3 80 5.09 15.5 0.155
6 3.0 2.0 6.7 7.8 100 3.39 13.7 0.137
10 3.9 2.0 7.5 8.8 150 1.95 11.5 0.115
16 5.0 2.0 8.6 10.0 220 1.24 9.5 0.095
25 6.4 2.0 9.9 11.6 290 0.795 7.9 0.079
35 7.7 2.0 11.1 13.0 390 0.565 6.8 0.068
50 9.2 2.0 12.5 14.6 530 0.393 5.9 0.059
70 11.0 2.0 14.2 16.6 720 0.277 5.0 0.050
95 12.5 2.2 16.0 18.7 940 0.210 4.5 0.045
120 14.2 2.2 17.6 20.6 1160 0.164 4.0 0.040
150 15.8 2.2 19.1 22.3 1440 0.132 3.7 0.037
185 17.5 2.4 20.9 24.4 1760 0.108 3.4 0.034
240 20.1 2.4 23.7 27.5 2350 0.0817 3.0 0.030
300 22.5 2.4 25.6 30.1 2820 0.0654 2.7 0.027
400 25.8 2.6 29.2 34.2 3730 0.0495 2.4 0.024

(a)= For information,indicative only

21
Caledonian
FIREROL
Medium Wall
Single Core Sheathed
1.8/3 kV or 3.6/6 kV
to EN 50264-3-1 (FRL-MW-3S / FRL-MW-6S)

A. Conductor B. Insulation C. Sheath


Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and
installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 109)
Sheath
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104)
Electrical & Mechanical Properties
Nominal Voltage 1.8/3 kV or 3.6/6 kV
Maximum Conductor Temperature +90 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

22
Caledonian
FRL-MW-3S 1.8/3 kV

NOMINAL MIN. MEAN SHEATH CONDUCTOR INSULATION INSULATION


OVERALL OVERALL RESISTANCE RESISTANCE RESISTANCE
CROSS-SECTIONAL CONDUCTOR THICKNESS NOMINAL
AREA DIAMETER DIAMETER WEIGHT AT +20°C AT +20°C AT +90°C
DIAMETER (a) OF THICKNESS MIN.
(a) MAX.
INSULATION MIN.

max min min


2
mm mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km
1.5 1.5 1.3 0.8 5.7 6.7 60 13.7 21.8 0.218
2.5 1.95 1.3 0.8 6.0 7.0 70 8.21 18.8 0.188
4 2.5 1.3 0.8 6.5 7.6 90 5.09 16.2 0.162
6 3.0 1.3 0.8 7.0 8.1 110 3.39 14.4 0.144
10 3.9 1.5 0.8 8.2 9.6 170 1.95 12.8 0.128
16 5.0 1.5 0.8 9.2 10.8 240 1.24 10.7 0.107
25 6.4 1.8 1.0 11.5 13.4 350 0.795 10.3 0.103
35 7.7 1.8 1.0 12.7 14.9 450 0.565 8.9 0.089
50 9.2 1.8 1.0 14.1 16.5 590 0.393 7.8 0.078
70 11.0 1.8 1.0 15.8 18.5 790 0.277 6.7 0.067
95 12.5 2.2 1.0 18.0 21.0 1050 0.210 6.5 0.065
120 14.2 2.2 1.0 19.6 22.9 1270 0.164 6.1 0.061
150 15.8 2.2 1.2 21.4 25.1 1590 0.132 5.8 0.058
185 17.5 2.4 1.2 23.4 27.4 1900 0.108 5.6 0.056
240 20.1 2.4 1.2 25.9 30.3 2490 0.0817 5.0 0.050
300 22.5 2.4 1.2 28.1 32.9 3010 0.0654 4.5 0.045
400 25.8 2.6 1.4 32.0 37.4 3980 0.0495 4.4 0.044
FRL-MW-6S 3.6/6KV

CONDUCTOR INSULATION INSULATION


NOMINAL CONDUCTOR MIN. MEAN SHEATH OVERALL OVERALL
RESISTANCE RESISTANCE RESISTANCE
CROSS-SECTIONAL DIAMETER THICKNESS NOMINAL DIAMETER DIAMETER WEIGHT AT +20°C AT +20°C AT +90°C
AREA (a) OF THICKNESS MIN. MAX.
INSULATION MIN.

max min min


2
mm mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km
2.5 1.95 2.6 0.8 8.6 10.1 120 8.21 24.6 0.246
4 2.5 2.6 0.8 9.1 10.7 140 5.09 21.6 0.216
6 3.0 2.6 0.8 9.6 11.2 165 3.39 19.5 0.195
10 3.9 2.6 0.8 10.4 12.2 220 1.95 16.7 0.167
16 5.0 2.6 0.8 11.5 13.4 290 1.24 14.2 0.142
25 6.4 2.9 1.0 13.7 16.1 430 0.795 13.1 0.131
35 7.7 2.9 1.0 14.9 17.5 540 0.565 11.6 0.116
50 9.2 2.9 1.0 16.4 19.1 670 0.393 10.2 0.102
70 11.0 2.9 1.0 18.0 21.1 880 0.277 8.9 0.089
95 12.5 2.9 1.0 19.5 22.8 1100 0.210 8.0 0.080
120 14.2 2.9 1.2 21.4 25.1 1380 0.164 7.5 0.075
150 15.8 2.9 1.2 22.9 26.8 1660 0.132 6.9 0.069
185 17.5 3.2 1.2 25.1 29.4 2010 0.108 6.7 0.067
240 20.1 3.4 1.4 28.3 33.1 2670 0.0817 6.4 0.064
300 22.5 3.4 1.4 30.6 35.8 3170 0.0654 5.9 0.059
400 25.8 3.4 1.4 33.7 39.4 4150 0.0495 5.2 0.052

(a)= For information,indicative only

23
Caledonian
FIREROL Medium Wall
Multi Core Unscreened
300/500 V or 0.6/1 kV
to EN 50264-3-2 (FRL-MW-05M / FRL-MW-1M)

A. Conductor B. Insulation C. Sheath


Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and
installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EI 104)
Outer sheath
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104)
Electrical & Mechanical Properties
Nominal Voltage 300/500 V or 0.6/1 kV
Maximum Conductor Temperature +90 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

24
Caledonian

FRL-MW-05M 300/500V
CORE RESISTANCE INSULATION INSULATION
NOMINAL MIN. MEAN DIMENSIONS MIN. OF RESISTANCE RESISTANCE
OVERALL OVERALL
CROSS-SECTIONAL CONDUCTOR THICKNESS AVERAGE CONDUCTOR AT +20°C AT +20°C
MIN. MAX. DIAMETER DIAMETER WEIGHT
AREA DIAMETER (b) OF SHEATH AT +20°C EI 110 EI 106/7/8/9
ACC.TO ACC.TO MIN. MAX.
(a) INSULATION THICKNESS
EN EN max min min

mm2 mm mm mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km

2x1 1.25 0.4 2.0 2.4 0.6 5.3 6.2 40 20.0 15.0 7.5

4x1 1.25 0.4 2.0 2.4 0.6 6.1 7.2 70 20.0 15.0 7.5

7x1 1.25 0.4 2.0 2.4 0.7 7.5 8.7 120 20.0 15.0 7.5

9x1 1.25 0.4 2.0 2.4 0.7 9.1 10.6 160 20.0 15.0 7.5

12 x 1 1.25 0.4 2.0 2.4 0.7 9.8 11.5 190 20.0 15.0 7.5

19 x 1 1.25 0.4 2.0 2.4 0.8 11.7 13.7 290 20.0 15.0 7.5

24 x 1 1.25 0.4 2.0 2.4 1.0 14.1 16.5 390 20.0 15.0 7.5

32 x 1 1.25 0.4 2.0 2.4 1.0 15.5 18.2 490 20.0 15.0 7.5

37 x 1 1.25 0.4 2.0 2.4 1.0 16.1 18.9 550 20.0 15.0 7.5

40 x 1 1.25 0.4 2.0 2.4 1.0 16.7 19.6 600 20.0 15.0 7.5

4 x 1.5 1.5 0.5 2.4 2.9 0.7 7.3 8.6 110 13.7 14.0 7.0

7 x 1.5 1.5 0.5 2.4 2.9 0.7 8.7 10.2 170 13.7 14.0 7.0

9 x 1.5 1.5 0.5 2.4 2.9 0.8 10.9 12.7 230 13.7 14.0 7.0

12 x 1.5 1.5 0.5 2.4 2.9 0.8 11.8 13.8 280 13.7 14.0 7.0

19 x 1.5 1.5 0.5 2.4 2.9 1.0 14.2 16.6 440 13.7 14.0 7.0

24 x 1.5 1.5 0.5 2.4 2.9 1.0 16.6 19.5 560 13.7 14.0 7.0

32 x 1.5 1.5 0.5 2.4 2.9 1.2 18.7 21.9 720 13.7 14.0 7.0

37 x 1.5 1.5 0.5 2.4 2.9 1.2 19.5 22.8 820 13.7 14.0 7.0

4 x 2.5 1.95 0.5 2.9 3.4 0.7 8.3 9.8 150 8.21 13.0 6.5

7 x 2.5 1.95 0.5 2.9 3.4 0.8 10.2 11.9 240 8.21 13.0 6.5

9 x 2.5 1.95 0.5 2.9 3.4 1.0 12.9 15.1 350 8.21 13.0 6.5

12 x 2.5 1.95 0.5 2.9 3.4 1.0 13.9 16.3 420 8.21 13.0 6.5

19 x 2.5 1.95 0.5 2.9 3.4 1.0 16.3 19.1 640 8.21 13.0 6.5

24 x 2.5 1.95 0.5 2.9 3.4 1.2 19.6 22.9 840 8.21 13.0 6.5

(a)= One earth conductor (green/yellow) can be included upon request


(b)= For information,indicative only

25
Caledonian

FRL-MW-1M 0.6/1kV
CORE RESISTANCE INSULATION INSULATION
MIN. MEAN MIN.
NOMINAL DIMENSIONS OVERALL OVERALL OF RESISTANCE RESISTANCE
CONDUCTOR THICKNESS AVERAGE
CROSS-SECTIONAL DIAMETER DIAMETER WEIGHT CONDUCTOR AT +20°C AT +20°C
MIN. MAX.
DIAMETER (a) OF SHEATH
AREA MIN. MAX. AT +20°C EI 110 EI 106/7/8/9
ACC.TO ACC.TO
INSULATION THICKNESS
EN EN max min min

mm2 mm mm mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km

TWO CORES

1.5 1.5 0.7 2.8 3.3 0.70 7.2 9.0 70 13.7 21.0 10.5

2.5 1.95 0.7 3.2 3.8 0.70 8.0 10.0 100 8.21 17.2 8.6

4 2.5 0.7 3.8 4.4 0.70 9.1 11.3 130 5.09 14.2 7.1

6 3.0 0.7 4.2 5.0 0.80 10.1 12.4 170 3.39 12.2 6.1

10 3.9 0.7 5.1 5.9 1.00 12.5 15.4 290 1.95 9.8 4.9

16 5.0 0.7 6.1 7.2 1.00 14.9 18.4 390 1.24 7.9 3.9

25 6.4 0.9 7.8 9.1 1.20 18.7 23.0 590 0.795 7.3 3.6

35 7.7 0.9 9.0 10.6 1.20 21.2 25.9 790 0.565 6.7 3.3

50 9.2 1.0 10.6 12.4 1.40 25.1 30.7 1140 0.393 6.3 3.1

THREE CORES

1.5 1.5 0.7 2.8 3.3 0.70 7.7 9.5 100 13.7 21.0 10.5

2.5 1.95 0.7 3.2 3.8 0.70 8.5 10.5 130 8.21 17.2 8.6

4 2.5 0.7 3.8 4.4 0.70 9.7 12.0 180 5.09 14.2 7.1

6 3.0 0.7 4.2 5.0 0.80 10.7 13.2 250 3.39 12.2 6.1

10 3.9 0.7 5.1 5.9 1.00 13.3 16.5 410 1.95 9.8 4.9

16 5.0 0.7 6.1 7.2 1.00 16.0 19.6 570 1.24 7.9 3.9

25 6.4 0.9 7.8 9.1 1.20 20.0 24.7 850 0.795 7.3 3.6

35 7.7 0.9 9.0 10.6 1.40 23.0 28.2 1160 0.565 6.7 3.3

50 9.2 1.0 10.6 12.4 1.60 26.3 32.2 1680 0.393 6.3 3.1

FOUR CORES

1.5 1.5 0.7 2.8 3.3 0.70 8.5 10.5 120 13.7 21.0 10.5

2.5 1.95 0.7 3.2 3.8 0.70 9.4 11.6 170 8.21 17.2 8.6

4 2.5 0.7 3.8 4.4 0.80 10.9 13.4 240 5.09 14.2 7.1

6 3.0 0.7 4.2 5.0 1.00 12.2 14.9 330 3.39 12.2 6.1

10 3.9 0.7 5.1 5.9 1.00 14.7 18.2 540 1.95 9.8 4.9

16 5.0 0.7 6.1 7.2 1.20 18.0 22.1 750 1.24 7.9 3.9

25 6.4 0.9 7.8 9.1 1.40 22.6 27.6 1140 0.795 7.3 3.6

3 x 35 + 25 7.7/6.4 0.9/0.9 9.0/7.8 10.6/9.1 1.40 25.7 31.2 1486 0.565/0.795 6.7 3.3

3 x 50 + 25 9.2/6.4 1.0/0.9 10.6/7.8 12.4/9.1 1.60 30.0 36.5 2106 0.393/1.795 6.3 3.1

(a)= For information,indicative only

26
Caledonian
FIREROL Medium Wall
Multi Core Overall Screened
300/500 V or 0.6/1 kV
to EN 50264-3-2 (FRL-MW-05M-OS / FRL-MW-1M-OS)

A. Conductor B. Insulation C. Screen D. Sheath


Application
-Used as power and control cable for protected installations inside and outside of rail and transport vehicles, where handling and
installation cost are an important factor.
-Used in control, auxillary and main circuit wiring such as cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Flexible tinned annealed copper wires, stranded as per HD 383 (IEC 60228) class 5
Insulation
LSZH elastomeric compound as defined in EN 50264-1 (EI 106 to EI 110)
Overal screen
Tinned annealed copper wires
Outer sheath
LSZH elastomeric compound as defined in EN 50264-1 (EM 101 to EM 104)
Electrical & Mechanical Properties
Nominal Voltage 300/500 V or 0.6/1 kV
Maximum Conductor Temperature +90 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

27
Caledonian
FRL-MW-05M-OS 300/500 V
NOMINAL CORE RESISTANCE INSULATION INSULATION
MIN. MEAN MIN. MIN.
CROSS DIMENSIONS OVERALL OVERALL OF RESISTANCE RESISTANCE
CONDUCTOR THICKNESS SCREEN AVERAGE
-SECTIONAL DIAMETER DIAMETER WEIGHT CONDUCTOR AT +20°C AT +20°C
DIAMETER (b) OF WIRE SHEATH
AREA MIN. MAX. MIN. MAX. AT +20°C EI 110 EI 106/7/8/9
INSULATION DIAMETER THICKNESS
(a) max min min

2
mm mm mm mm mm mm mm mm mm kg/km Ω/km MΩ·km MΩ·km

2x1 1.25 0.4 2.0 2.4 0.16 0.6 6.0 7.1 70 20.0 15.0 7.5

4x1 1.25 0.4 2.0 2.4 0.16 0.7 7.0 8.2 110 20.0 15.0 7.5

7x1 1.25 0.4 2.0 2.4 0.16 0.7 8.2 9.6 150 20.0 15.0 7.5

9x1 1.25 0.4 2.0 2.4 0.21 0.8 10.2 11.9 220 20.0 15.0 7.5

12x1 1.25 0.4 2.0 2.4 0.21 0.8 10.9 12.7 260 20.0 15.0 7.5

19x1 1.25 0.4 2.0 2.4 0.26 1.0 13.2 15.4 400 20.0 15.0 7.5

24x1 1.25 0.4 2.0 2.4 0.26 1.0 15.2 17.8 500 20.0 15.0 7.5

32x1 1.25 0.4 2.0 2.4 0.26 1.0 16.6 19.4 610 20.0 15.0 7.5

37x1 1.25 0.4 2.0 2.4 0.26 1.0 17.2 20.1 670 20.0 15.0 7.5

40x1 1.25 0.4 2.0 2.4 0.26 1.2 18.2 21.3 740 20.0 15.0 7.5

4x1.5 1.5 0.5 2.4 2.9 0.16 0.7 8.0 9.4 140 13.7 14.0 7.0

7x1.5 1.5 0.5 2.4 2.9 0.21 0.7 9.6 11.3 220 13.7 14.0 7.0

9x1.5 1.5 0.5 2.4 2.9 0.21 1.0 12.1 14.2 290 13.7 14.0 7.0

12x1.5 1.5 0.5 2.4 2.9 0.21 1.0 13.0 15.2 360 13.7 14.0 7.0

19x1.5 1.5 0.5 2.4 2.9 0.26 1.0 15.3 17.9 540 13.7 14.0 7.0

24x1.5 1.5 0.5 2.4 2.9 0.26 1.2 18.1 21.2 700 13.7 14.0 7.0

32x1.5 1.5 0.5 2.4 2.9 0.26 1.2 19.8 23.2 860 13.7 14.0 7.0

37x1.5 1.5 0.5 2.4 2.9 0.26 1.2 20.5 24.0 960 13.7 14.0 7.0

4x2.5 1.95 0.5 2.9 3.4 0.21 0.7 9.2 10.8 200 8.21 13.0 6.5

7x2.5 1.95 0.5 2.9 3.4 0.21 0.8 11.1 13.0 310 8.21 13.0 6.5

9x2.5 1.95 0.5 2.9 3.4 0.26 1.0 13.9 16.3 440 8.21 13.0 6.5

12x2.5 1.95 0.5 2.9 3.4 0.26 1.0 15.0 17.5 520 8.21 13.0 6.5

19x2.5 1.95 0.5 2.9 3.4 0.26 1.2 17.8 20.8 770 8.21 13.0 6.5

24x2.5 1.95 0.5 2.9 3.4 0.26 1.2 20.6 24.1 970 8.21 13.0 6.5

(a)= One earth conductor (green/yellow) can be included upon request


(b)= For information,indicative only

28
Caledonian
FRL-MW-1M-OS 0.6/1kV

CORE RESISTANCE INSULATION INSULATION


DIMENSIONS OF RESISTANCE RESISTANCE
NOMINAL MIN. MEAN MIN. MIN.
CROSS-SECTIONAL CONDUCTOR
DIAMETER THICKNESS SCREEN OVERALL OVERALL
AVERAGE DIAMETER DIAMETER WEIGHT
CONDUCTOR AT +20°C AT +20°C
AREA OF WIRE SHEATH AT +20°C EI 105 EI 101-EI 104
(a) (a) INSULATION DIAMETER THICKNESS MIN. MAX.
MIN. MAX.
max min min
2
mm mm mm mm mm mm mm mm mm Kg/km Ω/km MΩ·km MΩ·km

TWO CORES

1.5 1.5 0.7 2.8 3.3 0.16 0.70 7.9 9.9 90 13.7 21.0 10.5

2.5 1.95 0.7 3.2 3.8 0.16 0.70 8.7 10.7 120 8.21 17.2 8.6

4 2.5 0.7 3.8 4.4 0.21 0.80 10.2 12.7 170 5.09 14.2 7.1

6 3.0 0.7 4.2 5.0 0.21 0.80 10.9 13.6 210 3.39 12.2 6.1

10 3.9 0.7 5.1 5.9 0.21 1.00 13.4 16.6 320 1.95 9.8 4.9

16 5.0 0.7 6.1 7.2 0.26 1.00 16.0 19.8 470 1.24 7.9 3.9

25 6.4 0.9 7.8 9.1 0.26 1.20 19.8 24.6 690 0.795 7.3 3.6

35 7.7 0.9 9.0 10.6 0.31 1.40 22.8 27.9 940 0.565 6.7 3.3

50 9.2 1.0 10.6 12.4 0.31 1.40 26.4 32.3 1260 0.393 6.3 3.1

THREE CORES

1.5 1.5 0.7 2.8 3.3 0.16 0.70 8.4 10.4 120 13.7 21.0 10.5

2.5 1.95 0.7 3.2 3.8 0.16 0.70 9.2 11.4 160 8.21 17.2 8.6

4 2.5 0.7 3.8 4.4 0.21 0.80 10.8 13.3 230 5.09 14.2 7.1

6 3.0 0.7 4.2 5.0 0.21 0.80 11.6 14.3 300 3.39 12.2 6.1

10 3.9 0.7 5.1 5.9 0.26 1.00 14.4 18.0 500 1.95 9.8 4.9

16 5.0 0.7 6.1 7.2 0.26 1.20 17.4 21.3 680 1.24 7.9 3.9

25 6.4 0.9 7.8 9.1 0.26 1.20 21.3 26.1 970 0.795 7.3 3.6

35 7.7 0.9 9.0 10.6 0.31 1.40 24.5 29.8 1330 0.565 6.7 3.3

50 9.2 1.0 10.6 12.4 0.31 1.60 28.3 34.6 1820 0.393 6.3 3.1

FOUR CORES

1.5 1.5 0.7 2.8 3.3 0.16 0.70 9.1 11.3 150 13.7 21.0 10.5

2.5 1.95 0.7 3.2 3.8 0.21 0.80 10.4 12.9 220 8.21 17.2 8.6

4 2.5 0.7 3.8 4.4 0.21 0.80 11.8 14.5 290 5.09 14.2 7.1

6 3.0 0.7 4.2 5.0 0.21 1.00 13.1 16.1 400 3.39 12.2 6.1

10 3.9 0.7 5.1 5.9 0.26 1.00 15.9 19.5 640 1.95 9.8 4.9

16 5.0 0.7 6.1 7.2 0.26 1.20 19.3 23.6 860 1.24 7.9 3.9

25 6.4 0.9 7.8 9.1 0.31 1.40 24.0 29.3 1290 0.795 7.3 3.6

3x35+25 7.7/6.4 0.9/0.9 9.0/7.8 10.6/9.1 0.31 1.4 26.9 32.9 1910 0.565/0.795 6.7 3.3

3x50+25 9.2/6.4 1.0/0.9 10.6/7.8 12.4/9.1 0.31 1.6 31.5 38.2 2560 0.393/0.795 6.3 3.1

(a)= For information,indicative only

29
Caledonian
FIREROL Thin Wall
Single Core Unsheathed
300/500 V to EN 50306-2 (FRL-TW-05SU)

A Conductor B. Insulation

Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are
an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.

Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound

Electrical & Mechanical Properties


Nominal Voltage 300/500V
Maximum Conductor Temperature +120/+150 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

30
Caledonian
FRL-TW-05SU 300/500 V
NOMINAL NUMBER X RESISTANCE
THICKNESS OVERALL
CROSS NOMINAL DIAMETER OF
SECTIONAL DIAMETER OF OF DIAMETER CONDUCTOR
INSULATION WEIGHT
AREA WIRE AT 20°C

2
min max min min max max
mm mm
mm mm mm mm mm kg/km Ω/km
0.5 19 x 0.18 0.80 0.95 0.18 1.15 1.45 7 40.1
0.75 37 x 0.16(a) 1.00 1.15 0.18 1.35 1.65 8 26.7
1.0 37 x 0.18(a) 1.10 1.30 0.18 1.45 1.80 10 20.0
1.5 37 x 0.23(a) 1.45 1.65 0.22 1.95 2.30 20 13.7
2.5 37 x 0.30(a) 1.85 2.15 0.28 2.50 2.85 25 8.21
-This cable may be supplied in 19 strand conductor providing all product performance requirements in the specification are met

31
Caledonian
FIREROL Thin Wall
Single Core Overall Screened
300/500V to EN 50306-3 (FRL-TW-05S-OS)

A Conductor B. Insulation C. Screen D. Sheath


Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are
an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Overal screen
Tinned annealed copper wires
Outer sheath
LSZH special compound (S1 & S2)
Electrical & Mechanical Properties
Nominal Voltage 300/500V
Maximum Conductor Temperature +120/+150 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

32
Caledonian
FRL-TW-05S-OS 300/500V
NUMBER OF CORES AND NOMINAL MINIMUM THICKNESS OF SHEATH
OVERALL DIAMETER WEIGHT
CROSS SECTION AT ANY POINT
2
(mm ) (mm) min. (mm) max. (mm) (kg/km)
1 x 0.5 0.20 2.3 2.8 10

1 x 0.75 0.20 2.5 3.0 20

1x1 0.20 2.7 3.2 25

1 x 1.5 0.20 3.1 3.6 30

1 x 2.5 0.20 3.6 4.4 40

33
Caledonian
FIREROL Thin Wall
Multi-Core Overall Screened
300/500V to EN 50306-3 (FRL-TW-05M-OS)

A Conductor B. Insulation C. Screen D. Sheath


Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are
an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Overal screen
Tinned annealed copper wires
Outer sheath
LSZH special compound (S1 & S2)
Electrical & Mechanical Properties
Nominal Voltage 300/500V
Maximum Conductor Temperature +120/+150 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

34
Caledonian
FRL-TW-05M-OS 300/500 V
NUMBER OF CORES AND NOMINAL MINIMUM THICKNESS OF SHEATH
OVERALL DIAMETER WEIGHT
CROSS SECTION AT ANY POINT
2
(mm ) (mm) min. (mm) max. (mm) (kg/km)

2 x 0.5 0.20 3.5 4.3 30

3 x 0.5 0.20 3.7 4.5 30

4 x 0.5 0.20 4.0 5.0 40

2 x 0.75 0.20 3.9 4.7 30

3 x 0.75 0.20 4.0 5.0 40

4 x 0.75 0.20 4.5 5.5 60

2x1 0.20 4.2 5.2 40

3x1 0.20 4.5 5.5 55

4x1 0.20 5.0 6.0 70

2 x 1.5 0.20 5.1 6.1 60

3 x 1.5 0.20 5.4 6.4 80

4 x 1.5 0.20 6.0 7.0 100

2 x 2.5 0.20 6.4 7.4 90

3 x 2.5 0.20 6.8 7.8 120

4 x 2.5 0.20 7.5 8.5 140

35
Caledonian
FIREROL Thin Wall
Multi-Core Cables with Standard Wall Sheath
300/500 V to EN 50306-4 (FRL-TW-05MSW)

A. Conductor B. Insulation C Sheath


Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are
an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Outer sheath
LSZH special compound (S2. EM101- EM104)
Electrical & Mechanical Properties
Nominal Voltage 300/500V
Maximum Conductor Temperature +120/+150 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

36
Caledonian
FRL-TW-05MSW 300/500 V
NUMBER OF CORES AND NOMINAL MINIMUM THICKNESS OF SHEATH
OVERALL DIAMETER WEIGHT
CROSS SECTION AT ANY POINT
2
(mm ) (mm) min. (mm) max. (mm) (kg/km)

4 x 0.5 0.42 4.1 5.1 30

7 x 0.5 0.42 4.9 5.9 50

13 x 0.5 0.56 7.3 8.3 100

19 x 0.5 0.56 8.1 9.1 140

37 x 0.5 0.56 10.8 12.0 250

4 x 0.75 0.42 4.6 5.6 40

7 x 0.75 0.42 5.5 6.5 70

13 x 0.75 0.56 8.2 9.2 130

19 x 0.75 0.56 9.0 10.2 180

37 x 0.75 0.56 12.2 13.4 340

48 x 0.75 0.56 13.9 15.5 440

4 x 1.0 0.42 4.9 5.9 50

7 x 1.0 0.42 6.0 7.0 90

13 x 1.0 0.56 8.7 9.9 160

19 x 1.0 0.56 9.8 11.0 230

37 x 1.0 0.56 13.3 14.5 430

4 x 1.5 0.42 6.0 7.0 80

7 x 1.5 0.56 7.7 9.8 140

13 x 1.5 0.56 10.7 11.9 250

19 x 1.5 0.56 12.0 13.2 350

37 x 1.5 0.56 16.2 17.8 650

2 x 2.5 0.56 6.7 7.7 70

3 x 2.5 0.56 7.7 8.1 110

4 x 2.5 0.56 7.9 8.9 140

37
Caledonian
FIREROL Thin Wall
Multi-Core Cables with Exposed Standard Wall Sheath
300/500 V to EN 50306-4 (FRL-TW-05MESW)

A. Conductor B. Insulation C. Sheath


Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are
an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Outer sheath
LSZH special compound (S2. EM101-EM104)
Electrical & Mechanical Properties
Nominal Voltage 300/500V
Maximum Conductor Temperature +120/+150 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

38
Caledonian
FRL-TW-05MESW 300/500V
NUMBER OF CORES AND NOMINAL MINIMUM THICKNESS OF SHEATH
OVERALL DIAMETER WEIGHT
CROSS SECTION AT ANY POINT
2
(mm ) (mm) min. (mm) max. (mm) (kg/km)

4 x 0.5 1.0 5.5 6.5 50

7 x 0.5 1.0 6.3 7.3 70

13 x 0.5 1.0 8.3 9.3 120

19 x 0.5 1.0 9.0 10.2 150

37 x 0.5 1.0 12.3 13.5 290

4 x 0.75 1.0 6.0 7.0 60

7 x 0.75 1.0 6.9 7.9 90

13 x 0.75 1.0 9.1 10.3 150

19 x 0.75 1.0 10.0 11.2 200

37 x 0.75 1.0 13.2 14.4 360

48 x 0.75 1.0 14.8 16.4 460

4 x 1.0 1.0 6.3 7.3 70

7 x 1.0 1.0 7.3 8.3 110

13 x 1.0 1.0 9.7 10.9 180

19 x 1.0 1.0 10.7 11.9 250

37 x 1.0 1.0 14.0 15.6 450

4 x 1.5 1.0 7.4 8.4 100

7 x 1.5 1.0 8.6 9.8 150

13 x 1.5 1.0 11.7 12.9 270

19 x 1.5 1.0 13.0 14.2 370


37 x 1.5 1.0 17.2 18.8 690

2 x 2.5 1.0 7.7 8.7 90

3 x 2.5 1.0 8.1 9.1 120

4 x 2.5 1.0 8.8 10.0 150

39
Caledonian
FIREROL Thin Wall
Multi-Core Overall Screened Cables with
Standard Wall Sheath
300/500 V
to EN 50306-4 (FRL-TW-05MSW-OS)

A. Conductor B. Insulation C. Screen D. Sheath


Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are
an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Overal screen
Tinned annealed copper wires
Outer sheath
LSZH special compound as defined in EN 50264-1 (S2. EM 101 - EM 104)
Electrical & Mechanical Properties
Nominal Voltage 300/500 V
Maximum Conductor Temperature +90/+105 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

40
Caledonian
FRL-TW-05MSW-OS 300/500V
NUMBER OF CORES AND NOMINAL MINIMUM THICKNESS OF SHEATH AT
CROSS SECTION ANY POINT OVERALL DIAMETER WEIGHT
2
(mm ) (mm) min. (mm) max. (mm) (kg/km)

2 x 0.5 0.42 4.1 5.1 30

3 x 0.5 0.42 4.3 5.3 40

4 x 0.5 0.42 4.7 5.7 50

6 x 0.5 0.42 5.5 6.5 70

8 x 0.5 0.42 6.0 7.0 90

2 x 0.75 0.42 4.5 5.5 40

3 x 0.75 0.42 4.7 5.7 50

4 x 0.75 0.42 5.2 6.2 60

6 x 0.75 0.42 6.1 7.1 90

8 x 0.75 0.42 6.6 7.6 110

2 x 1.0 0.42 4.7 5.7 50

3 x 1.0 0.42 5.1 6.0 60

4 x 1.0 0.42 5.5 6.5 80

6 x 1.0 0.42 6.6 7.6 110

8 x 1.0 0.56 7.7 8.7 140

2 x 1.5 0.42 5.7 6.7 70

3 x 1.5 0.42 6.0 7.0 90

4 x 1.5 0.42 6.6 7.6 100

6 x 1.5 0.56 8.3 9.3 160

8 x 1.5 0.56 8.9 10.1 200

2 x 2.5 0.56 7.3 8.3 100

3 x 2.5 0.56 7.7 8.7 130

4 x 2.5 0.56 8.4 9.6 160

41
Caledonian
FIREROL Thin Wall
Multi-Core Overall Screened with
Exposed Standard Wall Sheath
300/500 V
to EN 50306-4 (FRL-TW-05MESW-OS)

A. Conductor B. Insulation C. Screen D. Sheath


Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are
an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc
Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Overal screen
Tinned annealed copper wires
Outer sheath
LSZH special compound as defined in EN 50264-1 (S2. EM 101 - EM 104)
Electrical & Mechanical Properties
Nominal Voltage 300/500 V
Maximum Conductor Temperature +90/+105 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

42
Caledonian
FRL-TW-05MESW-OS 300/500 V
NUMBER OF CORES AND NOMINAL MINIMUM THICKNESS OF
CROSS SECTION SHEATH AT ANY POINT OVERALL DIAMETER WEIGHT
2
(mm ) (mm) min. (mm) max. (mm) (kg/km)

2 x 0.5 1.0 5.5 6.5 50

3 x 0.5 1.0 5.7 6.7 50

4 x 0.5 1.0 6.1 7.1 60

6 x 0.5 1.0 6.9 7.9 90

8 x 0.5 1.0 7.5 8.5 110

2 x 0.75 1.0 5.9 6.9 60

3 x 0.75 1.0 6.2 7.2 70

4 x 0.75 1.0 6.5 7.5 80

6 x 0.75 1.0 7.5 8.5 110

8 x 0.75 1.0 8.2 9.2 130

2 x 1.0 1.0 6.2 7.2 60

3 x 1.0 1.0 6.5 7.5 80

4 x 1.0 1.0 6.9 7.9 90

6 x 1.0 1.0 8.0 9.0 130

8 x 1.0 1.0 8.6 9.8 160

2 x 1.5 1.0 7.1 8.1 90

3 x 1.5 1.0 7.4 8.4 110

4 x 1.5 1.0 8.0 9.0 130

6 x 1.5 1.0 9.2 10.4 170


8 x 1.5
1.0 10.2 11.4 220

2 x 2.5 1.0 8.3 9.3 120

3 x 2.5 1.0 8.6 9.8 150

4 x 2.5 1.0 9.4 10.6 180

43
Caledonian
FIREROL Thin Wall Multipair Individually Screened & Sheathed,
Overall Screened with Standard Wall sheath
300/500 V to EN 50306-4 (FRL-TW-05MPSW-IOS)

A. Conductor B. Insulation C. Screen D. Sheath

Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are
an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.

Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Overall screen
Tinned annealed copper wires
Pair screen
Individual screened and sheathed. Screened according to EN 50306-3; Sheathed according to EN 50306-3 (S1. S2)
Pair Identification
Pairs numbered according to EN 50306-4
Outer sheath
LSZH special compound (S2. EM 101 - EM 104)

Electrical & Mechanical Properties


Nominal Voltage 300/500 V
Maximum Conductor Temperature +90/+105 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 10 x Overall Diameter

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

44
Caledonian
FRL-TW-05MPSW-IOS 300/500 V
NUMBER OF CORES AND NOMINAL MINIMUM THICKNESS OF
CROSS SECTION SHEATH AT ANY POINT OVERALL DIAMETER WEIGHT
2
(mm ) (mm) min. (mm) max. (mm) (kg/km)

2 x 2 x 0.5 0.56 9.0 10.2 90

3 x 2 x 0.5 0.56 9.6 10.8 120

4 x 2 x 0.5 0.56 10.7 11.9 160

7 x 2 x 0.5 0.56 13.0 14.2 240

2 x 2 x 0.75 0.56 9.8 11.0 90

3 x 2 x 0.75 0.56 10.5 11.7 150

4 x 2 x 0.75 0.56 11.6 12.8 180

7 x 2 x 0.75 0.56 14.0 15.6 290

2 x 2 x 1.0 0.56 10.2 11.6 110

3 x 2 x 1.0 0.56 10.9 12.1 160

4 x 2 x 1.0 0.56 12.1 13.3 200

7 x 2 x 1.0 0.56 14.6 16.2 330

2 x 2 x 1.5 0.56 12.2 13.4 150

3 x 2 x 1.5 0.56 13.1 14.3 230

4 x 2 x 1.5 0.56 14.3 15.9 290

7 x 2 x 1.5 0.56 17.6 19.2 490

45
Caledonian
FIREROL Thin Wall
Multipair Individually Screened & Sheathed, with Exposed Standard Wall Sheath
300/500V to EN 50306-4 (FRL-TW-05MPESW-IOS)

A. Conductor B. Insulation C. Screen D. Sheath


Application
-Used as signal and control cable for protected installations inside and outside of rail and transport vehicles, where space and weight are
an important factor.
-Used in cable harnesses, switchboards and control panels, driver desks etc.
Construction
Conductor
Tinned annealed copper wires as defined in EN 50306-2
Insulation
LSZH special compound
Overall screen
Tinned annealed copper wires
Pair screen
Individual screened and sheathed. Screened according to EN 50306-3; Sheathed according to EN 50306-3 (S1. S2)
Pair Identification
Pairs numbered according to EN 50306-4
Outer sheath
LSZH special compound (S2. EM 101 - EM 104)
Electrical & Mechanical Properties
Nominal Voltage 300/500V
Maximum Conductor Temperature +90/+105 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 10 x Overall Diameter
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

46
Caledonian
FRL-TW-05MPESW-IOS 300/500 V
NUMBER OF CORES AND NOMINAL MINIMUM THICKNESS OF SHEATH AT ANY
CROSS SECTION POINT OVERALL DIAMETER WEIGHT
2
(mm ) (mm) min. (mm) max. (mm) (kg/km)

2 x 2 x 0.5 1.0 10.1 11.3 100

3 x 2 x 0.5 1.0 10.8 12.0 150

4 x 2 x 0.5 1.0 11.8 13.0 180

7 x 2 x 0.5 1.0 13.9 15.5 270

2 x 2 x 0.75 1.0 10.9 12.1 120

3 x 2 x 0.75 1.0 11.6 12.8 170

4 x 2 x 0.75 1.0 12.8 14.0 220

7 x 2 x 0.75 1.0 15.1 16.7 330

2 x 2 x 1.0 1.0 11.3 12.5 130

3 x 2 x 1.0 1.0 12.0 13.2 190

4 x 2 x 1.0 1.0 13.2 14.4 235

7 x 2 x 1.0 1.0 15.7 17.3 370

2 x 2 x 1.5 1.0 13.3 14.5 180

3 x 2 x 1.5 1.0 14.0 15.6 260


4 x 2 x 1.5
1.0 15.5 17.1 340

7 x 2 x 1.5 1.0 18.7 20.3 540

47
Caledonian
FIREROL High Temperature
Single Core Unsheathed cables
1.8/3 kV or 3.6/6 kV
to EN 50382-2 (FRL-HT-3SU / FRL-HT-6SU)

A. Conductor B. Insulation
Construction
Conductor
flexible tinned annealed copper wires (red copper only for 150° C core temperature) class 5 according to HD 383
Insulation
silicon rubber according to EN 50382-1 (EI 111)

Electrical & Mechanical Properties


Nominal Voltage 1.8/3 kV or 3.6/6 kV
Maximum Conductor Temperature +120/+150 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

48
Caledonian
FRL-HT-3SU 1.8/3 kV
MIN.
OVERALL RESISTANCE OF INSULATION
NOMINAL CONDUCTOR MIN. MEAN DIAMETER CONDUCTOR AT 20°C
CROSS-SECTIONAL DIAMETER THICKNESS RESISTANCE
WEIGHT
AREA (a) OF
INSULATION TINNED PLAIN AT AT
min max CONDUCTOR CONDUCTOR +20℃ +150℃
MIN. MIN.
2
mm mm mm mm mm kg/km Ω/km Ω/km MΩ·km MΩ·km
1.5 1.5 2.5 6.3 7.3 50 13.7 13.3 970 1.90
2.5 1.95 2.5 6.7 7.8 70 8.21 7.98 840 1.60
4 2.5 2.5 7.2 8.4 80 5.09 4.95 720 1.40
6 3.0 2.5 7.7 9.0 100 3.39 3.30 650 1.30
10 3.9 2.5 8.5 10.0 160 1.95 1.91 540 1.00
16 5.0 2.5 9.6 11.2 210 1.24 1.21 460 0.90
25 6.4 2.5 10.9 12.7 290 0.795 0.780 380 0.70
35 7.7 2.5 12.1 14.1 380 0.565 0.554 330 0.60
50 9.2 2.5 13.5 15.8 520 0.393 0.386 290 0.50
70 11.0 2.5 15.2 17.8 720 0.277 0.272 250 0.50
95 12.5 2.7 17.0 19.9 930 0.210 0.206 230 0.40
120 14.2 2.7 18.6 21.7 1140 0.164 0.161 210 0.40
150 15.8 2.7 20.1 23.5 1430 0.132 0.129 190 0.30
185 17.5 2.7 21.7 25.4 1720 0.108 0.106 170 0.30
240 20.1 2.7 24.1 28.2 2270 0.0817 0.0801 150 0.30
300 22.5 2.7 26.4 30.9 2750 0.0654 0.0641 140 0.20
400 25.8 2.9 29.9 34.9 3730 0.0495 0.0486 130 0.20
FRL-HT-6SU 3.6/6kV
MIN.
OVERALL RESISTANCE OF
NOMINAL CONDUCTOR MIN. MEAN INSULATION
DIAMETER CONDUCTOR AT 20°C RESISTANCE
CROSS-SECTIONAL DIAMETER THICKNESS WEIGHT
AREA (a) OF
INSULATION TINNED PLAIN AT AT
min max CONDUCTOR CONDUCTOR +20℃ +150℃
MIN. MIN.
2
mm mm mm mm mm kg/km Ω/km Ω/km MΩ·km MΩ·km
2.5 1.95 3.0 7.6 8.9 80 8.21 7.98 920 1.80
4 2.5 3.0 8.1 9.5 100 5.09 4.95 800 1.60
6 3.0 3.0 9.0 10.6 120 3.39 3.30 750 1.50
10 3.9 3.0 9.5 11.1 180 1.95 1.91 610 1.20
16 5.0 3.0 10.5 12.3 230 1.24 1.21 520 1.00
25 6.4 3.0 11.8 13.8 310 0.795 0.780 430 0.80
35 7.7 3.0 13.0 15.2 410 0.565 0.554 380 0.70
50 9.2 3.0 14.4 16.9 550 0.393 0.386 330 0.60
70 11.0 3.0 16.1 18.9 740 0.277 0.272 280 0.50
95 12.5 3.0 17.5 20.5 940 0.210 0.206 260 0.50
120 14.2 3.1 19.3 22.6 1170 0.164 0.161 240 0.40
150 15.8 3.1 20.8 24.4 1460 0.132 0.129 220 0.40
185 17.5 3.2 22.6 26.5 1760 0.108 0.106 200 0.40
240 20.1 3.4 25.4 29.8 2340 0.0817 0.0801 190 0.30
300 22.5 3.4 27.7 32.4 2820 0.0654 0.0641 170 0.30
400 25.8 3.4 30.8 36.0 3780 0.0495 0.0486 150 0.30
(a)= For information,indicative only

49
Caledonian
FIREROL High Temperature
Single Core Sheathed cables
1.8/3kV or 3.6/6 kV
to EN 50382-2 (FRL-HT-3S / FRL-HT-6S)

A. Conductor B. Insulation C. Sheath


Construction
Conductor
flexible tinned annealed copper wires(red copper only for 150° C core temperature)class 5 according to HD 383
Insulation
silicon rubber according to EN 50382-1 (EI 112)
Outer sheath
LSZH elastomeric compound according to EN 50382-1 (EM 105. EM 106 or EM 107)

Electrical & Mechanical Properties


Nominal Voltage 1.8/3kV or 3.6/6 kV
Maximum Conductor Temperature +90 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

50
Caledonian
FRL-HT-3S 1.8/3 kV
MIN.
OVERALL RESISTANCE OF INSULATION
NOMINAL MIN. MEAN MIN. DIAMETER CONDUCTOR AT 20°C
CROSS-SECTIONAL CONDUCTOR THICKNESS AVERAGE
WEIGHT
RESISTANCE
DIAMETER (a) OF SHEATH
AREA AT AT
INSULATION THICKNESS TINNED PLAIN
min max CONDUCTOR CONDUCTOR 20℃ 150℃
MIN. MIN.
2
mm mm mm mm mm mm kg/km Ω/km Ω/km MΩ·km MΩ·km
1.5 1.5 1.3 1.4 6.8 7.9 70 13.7 13.3 670 1.30
2.5 1.95 1.3 1.4 7.2 8.4 80 8.21 7.98 570 1.10
4 2.5 1.3 1.4 7.7 9.0 100 5.09 4.95 480 0.90
6 3.0 1.3 1.4 8.2 9.6 120 3.39 3.30 420 0.80
10 3.9 1.5 1.4 9.4 11.0 190 1.95 1.91 380 0.70
16 5.0 1.5 1.4 10.5 12.2 240 1.24 1.21 310 0.60
25 6.4 1.8 1.4 12.3 14.4 340 0.795 0.780 300 0.60
35 7.7 1.8 1.4 13.6 15.9 440 0.565 0.554 250 0.50
50 9.2 1.8 1.4 15.0 17.5 580 0.393 0.386 220 0.40
70 11.0 1.8 1.5 16.8 19.7 780 0.277 0.272 200 0.40
95 12.5 2.2 1.5 19.0 22.2 1020 0.210 0.206 190 0.40
120 14.2 2.2 1.6 20.8 24.3 1270 0.164 0.161 180 0.30
150 15.8 2.2 1.6 22.3 26.1 1560 0.132 0.129 160 0.30
185 17.5 2.4 1.7 24.5 28.6 1890 0.108 0.106 160 0.30
240 20.1 2.4 1.8 27.1 31.7 2480 0.0817 0.0801 140 0.20
300 22.5 2.4 1.9 29.5 34.6 2990 0.0654 0.0641 120 0.20
400 25.8 2.6 2.0 33.2 38.9 4010 0.0495 0.0486 120 0.20
FRL-HT-6S 3.6/6 kV
MIN.
OVERALL RESISTANCE OF INSULATION
NOMINAL MIN. MEAN MIN. DIAMETER CONDUCTOR AT 20°C
CROSS-SECTIONAL CONDUCTOR THICKNESS AVERAGE
WEIGHT
RESISTANCE
DIAMETER (a) OF SHEATH
AREA AT AT
INSULATION THICKNESS TINNED PLAIN
min max CONDUCTOR CONDUCTOR 20℃ 150℃
MIN. MIN.
2
mm mm mm mm mm mm kg/km Ω/km Ω/km MΩ·km MΩ·km
2.5 1.95 2.6 1.4 9.9 11.6 130 8.21 7.98 870 1.70
4 2.5 2.6 1.4 10.4 12.2 150 5.09 4.95 750 1.50
6 3.0 2.6 1.4 10.9 12.8 180 3.39 3.30 670 1.30
10 3.9 2.6 1.4 11.8 13.8 240 1.95 1.91 570 1.10
16 5.0 2.6 1.4 12.8 15.0 300 1.24 1.21 480 0.90
25 6.4 2.9 1.4 14.7 17.2 410 0.795 0.780 430 0.80
35 7.7 2.9 1.4 15.9 18.6 510 0.565 0.554 380 0.70
50 9.2 2.9 1.5 17.5 20.5 660 0.393 0.386 330 0.60
70 11.0 2.9 1.5 19.2 22.4 870 0.277 0.272 280 0.50
95 12.5 2.9 1.6 20.8 24.3 1100 0.210 0.206 250 0.50
120 14.2 2.9 1.6 22.4 26.2 1330 0.164 0.161 230 0.40
150 15.8 2.9 1.7 24.1 28.2 1640 0.132 0.129 210 0.40
185 17.5 3.2 1.8 26.4 30.9 1990 0.108 0.106 210 0.40
240 20.1 3.4 1.9 29.4 34.4 2620 0.0817 0.0801 190 0.30
300 22.5 3.4 1.9 31.7 37.1 3120 0.0654 0.0641 170 0.30
400 25.8 3.4 2.0 35.0 40.9 4150 0.0495 0.0486 150 0.30
(a)= For information,indicative only

51
Caledonian
FIREROL High Temperature
Single core cables with Reinforced Insulation
3.6/6 kV to EN 50382-2 (FRL-HT-6SURI)

A. Conductor B. Insulation

Construction
Conductor
extra flexible tinned annealed copper wires(red copper only for 150° C core temperature)class 6 according to HD 383
Insulation
silicon rubber according to EN 50382-1 (EI 112)
Electrical & Mechanical Properties
Nominal Voltage 3.6/6kV
Maximum Conductor Temperature +120/+150 °C (fixed installation)
Minimum Permissible Ambient Temperature -25/-40 °C (fixed installation)
Bending Radius 3 x Overall Diameter (D<12mm);
4 x Overall Diameter (D>12mm)
Chemical & Environmental Properties
EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRL-HT-6SURI 3.6/6 kV
OVERALL RESISTANCE OF MIN.
NOMINAL MIN. MEAN DIAMETER CONDUCTOR AT 20°C INSULATION
CROSS-SECTIONAL CONDUCTOR THICKNESS RESISTANCE
AREA DIAMETER OF WEIGHT
(a) TINNED PLAIN AT +20 AT
(a) INSULATION min max CONDUCTOR CONDUCTOR ℃ +150℃
MIN. MIN.
2
mm mm mm mm mm kg/km Ω/km Ω/km MΩ·km MΩ·km
50 9.2 3.0 15.2 17.8 560 0.393 0.386 340 0.70
70 11.0 3.0 16.9 19.8 770 0.277 0.272 300 0.60
95 12.5 3.0 18.3 21.4 970 0.210 0.206 270 0.55
120 14.2 3.1 20.1 23.5 1200 0.164 0.161 250 0.50
150 15.8 3.1 21.6 25.3 1480 0.132 0.129 220 0.45
185 17.5 3.2 23.4 27.4 1800 0.108 0.106 210 0.40
(a)= For information,indicative only

52
Caledonian
DATABUS CABLES
WTB (Wired Train Bus) Cables
FRA-WTB-02YCH-2C0.75S/FRA-WTB-02YSCH-1P0.75S

Stranded Tin Plated Copper Conductor


Foam Skin Insulation
Plastic Tape
Tin Plated Copper Braid
Cross-linked Oil Resistance LSZH Sheath

Application
The cables are designed for permanent installation inside of rolling stock to connect fixed parts. A typical application is a
communication system in a locomotive. The system uses a wire backed bus system to the TCN standard for control and
instrumentation and for diagnostics. This bus system consists of the rail bus WTB (Wired Train Bus) and the road bus MVB
(Multifunction Vehicle Bus) which are connected via redundant gateways.

Construction
Conductors
Stranded tin plated copper conductor according to IEC 60228 class 5
Insulation
Foam skin-composite PE made of inner cellular layer and outer solid skin
Core Wrapping
Plastic tape(s)
EMC Screen
Tin plated copper braid
Outer Sheath
Cross-linked oil resistant LSZH compound

Electrical & Mechanical Properties


Nominal Voltage 300V
Maximum Temperature +100℃
Minimum Temperature -40℃
Bending Radius 10OD

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables

54
Caledonian
DATABUS CABLES
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRA-WTB-02YSCH-2C0.75S
Nominal Nominal Maximum Maximum
Nominal Nominal
Cross Diameter Nominal Conductor Impedance Transfer Maximum Attenuation
Sheath Overall
Sectional of Weight Resistance Impedance
Thickness Diameter
Area Strands 20℃ @1-10MHz f<=30MHz @1MHz @1.5MHz @2MHz @3MHz
mm2 No/mm2 mm mm kg/km Ω/km Ω mΩ/m dB/km dB/km dB/km dB/km
0.75 19/0.22 1.4 8.3 97 26.7 120+/-12 30 10 13 14 18

FRA-WTB-02YSCH-1P0.75S
Nominal Nominal Maximum Maximum
Nominal Nominal Conductor Impedance Transfer Maximum Attenuation
Cross Diameter Nominal
Sheath Overall Resistance Impedance
Sectional of Weight
Thickness Diameter
Area Strands 20℃ @1-10MHz f<=30MHz @1MHz @1.5MHz @2MHz @3MHz
mm 2
No/mm 2
mm mm kg/km Ω/km Ω mΩ/m dB/km dB/km dB/km dB/km
0.75 19/0.22 1.4 9.0 110 26.7 120+/-12 30 10 13 14 18

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


55
Caledonian
DATABUS CABLES
MVB(Multifunction Vehicle Bus)Cables
FRA-MVB-02YS(ST+C)H-1P0.5S+1C0.5S
FRA-MVB-02YS(ST+C)H-2P0.5S

Cross-linked Oil Resistance LSZH Sheath


Tin Plated Copper Braid
Plastic Tape
Foam Skin Insulation
Stranded Tin Plated Copper Conductor

Application
The cables are designed for permanent installation inside of rolling stock to connect fixed parts. A typical application is a
communication system in a locomotive. The system uses a wire backed bus system to the TCN standard for control and
instrumentation and for diagnostics. This bus system consists of the rail bus WTB (Wired Train Bus) and the road bus MVB
(Multifunction Vehicle Bus) which are connected via redundant gateways.

Construction
Conductor
Stranded tin plated copper conductor according to IEC 60228 class 5
Insulation
Foam skin-composite PE made of inner cellular layer and outer solid skin
Core Wrapping
Plastic tape(s)
EMC Screen
Tin plated copper braid
Outer Sheath
Cross-linked oil resistant LSZH compound

Electrical & Mechanical Properties


Nominal Voltage 300V
Maximum Temperature +90℃
Minimum Temperature -40℃
Bending Radius 10OD

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 nterior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

56
Caledonian
DATABUS CABLES
Fire Performance in general
EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRA-MVB-02YS(ST+C)H-1P0.5S+1C0.5S
Nominal Nominal Maximum Maximum
Nominal Nominal Conductor Impedance Transfer Maximum Attenuation
Cross Diameter Nominal
Sheath Overall
Sectional of Weight Resistance Impedance
Thickness Diameter
Area Strands 20℃ @0.5-2MHz f<=20MHz @1MHz @1.5MHz @2MHz @3MHz
mm2 No/mm2 mm mm kg/km Ω/km Ω mΩ/m dB/km dB/km dB/km dB/km
0.5 19/0.18 1.2 6.8 62 41 120+/-12 20 12.5 15 18 21

FRA-MVB-02YS(ST+C)H-2P0.5S
Nominal Nominal Maximum Maximum
Nominal Nominal
Cross Diameter Nominal Conductor Impedance Transfer Maximum Attenuation
Sheath Overall Resistance Impedance
Sectional of Weight
Thickness Diameter
Area Strands 20℃ @1-10MHz f<=20MHz @1MHz @1.5MHz @2MHz @3MHz
mm2 No/mm2 mm mm kg/km Ω/km Ω mΩ/m dB/km dB/km dB/km dB/km
0.5 19/0.18 1.2 8.3 100 41 120+/-12 20 12.5 15 18 21

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


57
Caledonian
DATABUS CABLES

MVB(Multifunction Vehicle Bus)Cables(Redundant Version)


FRA-MVB-02YS(ST+C)H-1Q0.5S+4C0.25S

Cross-linked Oil Resistance HFFR Sheath


Tin Plated Copper Braid
Plastic Tape
Stranded Tin Plated Copper Conductor
Foam Skin Insulation

Application
The cables are designed for permanent installation inside of rolling stock to connect fixed parts. A typical application is a
communication system in a locomotive. The system uses a wire backed bus system to the TCN standard for control and
instrumentation and for diagnostics. This bus system consists of the rail bus WTB (Wired Train Bus) and the road bus MVB
(Multifunction Vehicle Bus) which are connected via redundant gateways.

Construction
Conductor
Stranded tin plated copper conductor according to IEC 60228 class 5
Insulation
Foam skin-composite PE made of inner cellular layer and outer solid skin
Core Wrapping
Plastic tape(s)
EMC Screen
Tin plated copper braid
Outer Sheath
Cross-linked oil resistant LSZH compound.

Electrical & Mechanical Properties


Nominal Voltage 300V
Maximum Temperature +100℃
Minimum Temperature -40℃
Bending Radius 10OD

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable

58
Caledonian
DATABUS CABLES
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRA-MVB-02YS(ST+C)H-1Q0.5S+4C0.25S
Nominal Maximum Maximum
Nominal Nominal Conductor Impedance Transfer Maximum Attenuation
Nominal Cross Diameter Nominal
Sheath Overall Resistance Impedance
Sectional Area of Weight
Thickness Diameter
Strands 20℃ @0.75-3MHz f<=20MHz @1.5MHz @3MHz
mm 2
No/mm 2
mm mm kg/km Ω/km Ω mΩ/m dB/km dB/km
0.5 19/0.18 1.2 7.9 95 41 120+/-12 20 17 25

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


59
Caledonian
DATABUS CABLES

WTB(Wired Train Bus)/MVB(Multifunction Vehicle Bus)Cables


FRA-WTB/MVB-02YS(ST+C)H-1P20A

Cross-linked Oil Resistance LSZH Sheath


Plastic Tape
Stranded Tin Plated Copper Conductor
Aluminium Clad Polyester Foil
Plastic Tape
Foam Skin Insulation
Tin Plated Copper Braid

Application
The cables are designed for permanent installation inside of rolling stock to connect fixed parts. A typical application is a
communication system in a locomotive. The system uses a wire backed bus system to the TCN standard for control and
instrumentation and for diagnostics. This bus system consists of the rail bus WTB (Wired Train Bus) and the road bus MVB
(Multifunction Vehicle Bus) which are connected via redundant gateways.

Construction
Conductor
Stranded tin plated copper conductor according to IEC 60228 class 5
Insulation
Foam skin-composite PE made of inner cellular layer and outer solid skin
Cable Element
Twisted pair
Core Wrapping
Plastic tape(s)
EMC Screen1
Aluminium clad polyester foil
EMC Screen2
Tin plated copper braid
Core Wrapping
Plastic tape(s)
Outer Sheath
Cross-linked oil resistant LSZH compound

Electrical & Mechanical Properties


Nominal Voltage 300V
Maximum Temperature +100℃
Minimum Temperature -40℃
Bending Radius 12OD

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

60
Caledonian
DATABUS CABLES
Fire Performance for rolling stock application
EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRA-WTB/MVB-02YS(ST+C)H-1P20A
Maximum
Nominal Nominal Nominal Conductor Impedance Maximum Attenuation
Nominal Cross Nominal
Diameter of AWG Sheath Overall Resistance
Sectional Area Weight
Strands Thickness Diameter
20℃ @0.75-3MHz @1MHz @2MHz
mm2 No/mm mm mm kg/km Ω/km Ω dB/km dB/km
0.62 19/0.2 20 1.2 8.3 80 33.1 120+/-12 10 15

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


61
Caledonian
DATABUS CABLES

Integrated 9/11/18/20 Cores 0.75mm sq UIC Databus Cables


FRA-UIC-4C10S+2C6S+1C2.5S+2C0.75S
FRA-UIC-4C10S+2C6S+1C2.5S+2C1S+2C0.75S
FRA-UIC-4Q1S+2C0.75S/FRA-UIC-4Q1S+2P0.75S

Cross-linked LSZH Sheath


Combined Element
Plastic Foil(s)
2x0.75mmsq Data Bus with Foam Skin Insulation
4x10mmsq with LSZH Insulation

Application
The cables are used as connecting cables to transmit digital signals inside railway rolling stocks

Construction
For 9 cores UIC databus cables
4 cores: 10 mm2 stranded tinned copper conductor with LSZH insulation..
Combined Element: 3 cores (with Cu-strand 2 x 6mm2, 1 x 2.5mm2) are twisted with a filling element to a
combined element.
Core Wrapping:Overlapped plastic-foil(s).
Elements sheaths:TPE
UIC Data Bus 0.75mm2: Two foam skin insulated tinned copper stranded conductors are twisted together with
two filling elements to a pair.
Core Wrapping:Overlapped plastic-foil(s).
Screen:Tin plated copper braid
Elements sheaths:TPE
Core Wrapping:Overlapped plastic-foil(s).
Stranding: 4 strands are twisted to a core together with 3 cored element, the UIC data bus and two fillers
Core Wrapping:Overlapped plastic-foil(s).
Outer Sheath:Cross-linked oil resistant LSZH compound.

Cross-linked LSZH Sheath


Combined Element
Plastic Foil(s)
2x0.75mmsq Data Bus with Foam Skin Insulation
4x10mmsq with LSZH Insulation

For 11 cores UIC databus cables


4 cores: 10 mm2 stranded tinned copper conductor with LSZH insulation
Combined Element: 5 cores (with Cu-strand 2 x 6mm2, 1 x 2.5mm2 and 2 x 1.0 mm2) are twisted with a filling
element to form a combined element.
Core Wrapping:Overlapped plastic-foil(s).

62
Caledonian
DATABUS CABLES
Element sheaths:TPE
UIC Data Bus 0.75mm2: Two foam skin insulated tinned copper r stranded conductors are twisted together
with two filling elements to a pair.
Core Wrapping:Overlapped plastic-foil(s).
Screen:Tin plated copper braid.
Element sheaths:TPE
Core Wrapping:Overlapped plastic-foil(s).
Stranding:4 strands are twisted to a core together with 5 cored element, the UIC data bus and two fillers.
Core Wrapping:Overlapped plastic-foil(s).
Outer Sheath:Cross-linked oil resistant LSZH compound.

Cross-linked LSZH Sheath


Tinned Copper Wire Braid Screen
Plastic Foil(s)
2x0.75mmsq Data Bus with Foam Skin Insulation
Star Quad

For 18/20 cores UIC databus cables


Star Quad: Four LSZH insulated 1mm2 stranded tinned copper conductors are twisted to form a star quad.
UIC Data Bus 0.75mm2: Two foam skin insulated tinned copper stranded conductors are twisted together with
two filling elements to form a pair.
Core Wrapping:Overlapped plastic-foil(s).
Screen:Tin plated copper braid
Element sheaths:TPE.
Core Wrapping:Overlapped plastic-foil(s).
Stranding: 4 star quads are stranded together with 2 or 4 UIC data bus cable and several fillers.
Core Wrapping:Overlapped plastic-foil(s).
Screen:Tin plated copper braid.
Outer Sheath:Cross-linked oil resistant LSZH compound.

Electrical & Mechanical Properties


Nominal Voltage 300V
Maximum Temperature +90℃
Minimum Temperature -40℃
Bending Radius 12OD

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density

63
Caledonian
DATABUS CABLES
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRA-UIC-4C10S+2C6S+1C2.5S+2C0.75S
Nominal Maximum
Nominal Nominal Nominal Conductor Impedance Maximum Attenuation
Cross Nominal
Diameter Sheath Overall Resistance
Sectional Weight
of Strands Thickness Diameter
Area 20℃ @0.75-3MHz @1MHz @1.5MHz @2MHz @3MHz
mm 2
No/mm mm mm kg/km Ω/km Ω dB/km dB/km dB/km dB/km
0.75 19/0.22 26.7 120+/-12 10 13 14 18
10 80/0.4 1.95 - - - - -
1.8 25 917
6 84/0.3 3.39 - - - - -
2.5 37/0.29 8.21 - - - - -

FRA-UIC-4C10S+2C6S+1C2.5S+2C1S+2C0.75S
Nominal Maximum
Nominal Nominal Nominal Conductor Impedance Maximum Attenuation
Cross Nominal
Diameter of Sheath Overall Resistance
Sectional Weight
Strands Thickness Diameter
Area 20℃ @0.75-3MHz @1MHz @1.5MHz @2MHz @3MHz
mm 2
No/mm mm mm kg/km Ω/km Ω dB/km dB/km dB/km dB/km
0.75 19/0.22 26.7 120+/-12 10 13 14 18
10 80/0.4 1.95 - - - - -
1.8 25 969
6 84/0.3 3.39 - - - - -
2.5 37/0.29 8.21 - - - - -

FRA-UIC-4Q1S+2C0.75S
Maximum
Nominal Nominal Nominal Conductor Impedance Maximum Attenuation
Nominal Cross Nominal
Diameter Sheath Overall Resistance
Sectional Area Weight
of Strands Thickness Diameter
20℃ @0.75-3MHz @1MHz @1.5MHz @2MHz @3MHz
mm2 No/mm mm mm kg/km Ω/km Ω dB/km dB/km dB/km dB/km
0.75 19/0.22 26.7 120+/-12 10 13 14 18
1.8 18.5 498
1 19/0.25 20 - - - - -

FRA-UIC-4Q1S+2P0.75S
Nominal Maximum
Nominal Nominal Nominal Conductor Impedance Maximum Attenuation
Cross Nominal
Diameter Sheath Overall Resistance
Sectional Weight
of Strands Thickness Diameter
Area 20℃ @0.75-3MHz @1MHz @1.5MHz @2MHz @3MHz
mm2 No/mm mm mm kg/km Ω/km Ω dB/km dB/km dB/km dB/km
0.75 19/0.22 26.7 120+/-12 10 13 14 18
1.5 23 530
1 19/0.25 20 - - - - -

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


64
Caledonian
DATABUS CABLES

Category 5E Databus Cables


FRA-Cat5E-4C0.5S/FRA-Cat5E-4C22A
FRA-Cat5E-4P22A

Plastic Tape
Electron Beam Crosslinkable LSZH Insulation
Plastic Laminated Aluminium-tape
Tin Plated Copper Braid
Stranded Silver Plated Copper Conductor
Electron Beam Crosslinkable LSZH Sheath

Application
The cables are designed for permanently protected installation, inside and outside railway rolling stock, buses and other
vehicles to connect fixed parts. Ethernet based networks as: infotainment, multimedia, passenger information system etc.

Construction
For 4 x 0.5, 4 x 22AWG cables
Conductors: Stranded tin plated copper conductor (for 0.5mm2 cables) or stranded silver plated copper conductor (for
22AWG cables) according to IEC 60228 class 5.
Insulation:Electron beam crosslinkable compound.
Cable Element: Individual conductor stranded together
EMC Screen1:Plastic laminated aluminium-tape.
EMC Screen2:Tin plated copper braid
Core Wrapping:Plastic tape(s).
Outer Sheath:Electron beam crosslinkable compound.
For 4 x 2 x 22AWG cables
Center: PE filler.
4 pairs 2 x 22AWG: Stranded tin plated copper conductor according to IEC 60228 class 5
Insulation:Electron beam crosslinkable compound.
EMC Screen1:Plastic laminated aluminium-tape.
EMC Screen2:Tin plated copper braid
Core Wrapping:Plastic tape(s).
Outer Sheath:Electron beam crosslinkable compound.

Electrical & Mechanical Properties


Nominal Voltage 300V
Maximum Temperature +90℃
Minimum Temperature -40℃
Bending Radius 6OD

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4

65
Caledonian
DATABUS CABLES
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

FRA-Cat5E-4C0.5S
Maximum Characteristic Transfer Maximum
Nominal Nominal Maximum
Nominal Cross Nominal Conductor Impedance Impedance Capacitance
Sheath Overall Resistance
Sectional Area Weight Resistance
Thickness Diameter Unbalance core to Core to
20℃ @100MHz f<=30MHz
core screen
mm2 mm mm kg/km Ω/km Ω/km Ω mΩ/m pF/m pF/m
0.5 1.2 8.3 102 40.1 1.1 100+/-5 200 65 100

FRA-Cat5E-4C22A
Maximum Characteristic Transfer Maximum
Nominal Nominal Maximum
Nominal Conductor Impedance Impedance Capacitance
AWG Sheath Overall Resistance
Weight Resistance core to Core to
Thickness Diameter Unbalance @100MHz f<=30MHz
20℃ core screen
mm mm kg/km Ω/km Ω/km Ω mΩ/m pF/m pF/m
22 1.2 7.25 81 54.4 1.1 100+/-5 200 65 100

FRA-Cat5E-4P22A
Maximum Characteristic Transfer Maximum
Nominal Nominal Maximum
Nominal Conductor Impedance Impedance Capacitance
AWG Sheath Overall Resistance
Weight Resistance core to Core to
Thickness Diameter Unbalance @100MHz f<=30MHz
20℃ core screen
mm mm kg/km Ω/km Ω/km Ω mΩ/m pF/m pF/m
22 1.2 12.6 174 54.4 1.1 100+/-5 200 65 100

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


66
Caledonian
DATABUS CABLES

DATABUS RS 485 CABLE 300/500V

Application
120Ohm data transmission cables

Construction
Multipair Databus RS 485 Double screened Cable
Conductor: Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2).
Insulation: Cross linked Foam PE.
Cable Element:Twisted pair.
Individual Screen:Individual Aluminium Tape.
Overall Screen: Copper Wire Braid
Outer Sheath:Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1.
Multipair Databus RS 485 Single screened Cable
Conductor: Stranded tin plated copper conductor according to IEC 60228 class 5(0.22mm2-1mm2).
Insulation: Cross linked Foam PE.
Cable Element:Twisted pair.
Overall Screen: Copper Wire Braid
Outer Sheath:Cross linked EVA rubber type EM 104 or equivalent, in accordance with EN 50264-1.

Electrical & Mechanical Properties


Nominal Voltage 300/500V
Impedance 120Ω+/-15%
Capacitance@1KHz 41nF/km
Insulation Resistance 5000MΩ

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density

67
Caledonian
DATABUS CABLES
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

300/500V Multipair Databus RS 485 Double screened Cable


Nominal Cross Sectional Nominal Diameter of
Nominal Overall Diameter Nominal Weight
No.of pair Area Strands
mm2 No/mm mm kg/km
1 0.22 7/0.2 4.5 58
2 0.22 7/0.2 6.2 79
4 0.22 7/0.2 6.5 118
1 0.5 16/0.2 6.6 79
2 0.5 16/0.2 9.0 105
4 0.5 16/0.2 9.8 145
1 0.75 24/0.2 9.5 115
2 0.75 24/0.2 10.3 135
4 0.75 24/0.2 11.6 182
1 1 30/0.2 11.5 125
2 1 30/0.2 12.5 150
4 1 30/0.2 13.5 180

300/500V Multipair Databus RS 485 Single screened Cable


Nominal Cross Sectional Nominal Diameter of
Nominal Overall Diameter Nominal Weight
No.of pair Area Strands
mm2 No/mm mm kg/km
1 0.22 7/0.2 4.2 55
2 0.22 7/0.2 5.9 75
4 0.22 7/0.2 6.2 115
1 0.5 16/0.2 6.3 75
2 0.5 16/0.2 8.5 100
4 0.5 16/0.2 9.4 140
1 0.75 24/0.2 9.0 110
2 0.75 24/0.2 9.7 130
4 0.75 24/0.2 11.1 178
1 1 30/0.2 11.0 120
2 1 30/0.2 12.0 145
4 1 30/0.2 13.0 175

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


68
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types IV Rolling Stock Cables
30/50V Singlecore Reduced Wall Unsheathed Cables

A.Conductor B.Insulation

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of core Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
1 0.5 19/0.18 1.34 6 40.1
1 0.75 37/0.16 1.56 8 26.7
1 1.0 37/0.18 1.69 10 20.0
1 1.5 37/0.23 2.07 16 13.7
1 2.5 37/0.30 2.66 27 8.21
1 4.0 37/0.37 3.32 41 5.09

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


69
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types V Rolling Stock Cables
30/50V Singlecore Standard Wall Unsheathed Cables

A.Conductor B.Insulation

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of core Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
1 0.5 16/0.2 2.32 10 40.1
1 0.75 24/0.2 2.53 13 26.7
1 1.0 32/0.2 2.71 15 20.0
1 1.5 30/0.25 3.23 22 13.7
1 2.5 50/0.25 3.7 34 8.21
1 4.0 56/0.3 4.5 50 5.09
1 6.0 84/0.3 5.09 75 3.39
1 10.0 80/0.4 6.3 123 1.95

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


70
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types VII Rolling Stock Cables
30/50V Multicore Standard Wall Cables

A.Conductor B.Insulation C.Sheath

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107
Sheath
Cross linked EVA rubber type EM 104

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor


Nominal Weight
No.of core Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
12 1.0 32/0.20 20.25 309 20.0
42 1.5 30/0.25 38.35 1661 13.7

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


71
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types VIII Rolling Stock Cables
30/50V Multipair Screened Standard Wall Cables

A.Conductor B.Insulation C.Screen D.Sheath

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
IEC 60332-1/IEC 60332-3C

Conductor

Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107
Screen Low Fire Load Iow
Copper Braid Screen
Sheath
Cross linked EVA rubber type EM 104

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor


Nominal Weight
No.of Pair Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
1 0.5 16/0.2 8.45 99 40.1
1 0.75 24/0.2 9.2 110 26.7
1 1.0 32/0.2 9.5 139 20.0
1 1.0 32/0.2 11.7 186 20.0
1 1.0 32/0.2 15.6 306 20.0
2 1.0 32/0.2 15.7 443 20.0
3 1.0 32/0.2 21.7 662 20.0

72
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types IX Rolling Stock Cables
30/50V Multipair Reduced Wall Screened Cables

A.Conductor B.Insulation C.Screen D.Sheath

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles。

Construction
IEC 60332-1/IEC 60332-3C

Conductor

Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107
Screen Low Fire Load Iow
Copper Braid Screen
Sheath
Cross linked EVA rubber type EM 104

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of pair Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
1 0.5 19/0.18 6.1 57 40.1
2 0.5 19/0.18 10.2 110 40.1
1 1.0 37/0.18 7.0 86 20.0
2 1.0 37/0.18 12.2 188 20.0
3 1.0 37/0.18 12.9 217 20.0
4 1.0 37/0.18 14.0 290 20.0

73
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types XII Rolling Stock Cables
300/500V Multicore Standard Wall Unsheathed Cables

A.Conductor B.Insulation

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of core Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
1 1.0 32/0.2 3.3 19 20.0
1 1.5 30/0.25 3.7 26 13.7
1 2.5 50/0.25 4.2 38 8.21
1 4.0 56/0.3 5.0 57 5.09
1 6.0 84/0.3 5.6 80 3.39

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


74
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types XIII Rolling Stock Cables
300/500V Multicore Standard Wall Cables

A.Conductor B.Insulation C.Sheath

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107
Sheath
Cross linked EVA rubber type EM 104

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of core Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
12 1.0 32/0.2 20.3 309 20.0
42 1.5 30/0.25 38.1 1775 13.7

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


75
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types I Rolling Stock Cables
600/1000V Multicore Reduced Wall Unsheathed Cables

A.Conductor B.Insulation

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of core Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
1 0.5 19/0.18 1.5 6 40.1
1 0.75 37/0.16 1.76 9 26.7
1 1.0 37/0.18 1.9 11 20.0
1 1.5 37/0.23 2.25 17 13.7
1 2.5 37/0.30 2.84 28 8.21
1 4.0 37/0.37 3.44 42 5.09

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


76
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types II Rolling Stock Cables
600/1000V Multicore Standard Wall Unsheathed Cables

A.Conductor B.Insulation

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of core Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
1 0.75 24/0.20 2.99 15 26.7
1 1.0 32/0.20 3.3 19 20.0
1 1.5 30/0.25 3.69 26 13.7
1 2.5 50/0.25 4.16 38 8.21
1 4.0 56/0.30 4.95 57 5.09
1 6.0 84/0.30 5.55 81 3.39
1 10.0 80/0.40 7.0 135 1.94
1 16.0 128/0.40 8.35 202 1.24
1 25.0 196/0.40 10.2 309 0.795
1 35.0 276/0.40 11.75 404 0.565

77
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
1 50.0 396/0.40 13.7 562 0.393
1 70.0 360/0.50 16.25 768 0.277
1 95.0 476/0.50 18.05 1003 0.210
1 150.0 756/0.50 22.95 1583 0.132
1 240.0 1221/0.50 27.9 2516 0.0817
1 300.0 1525/0.50 31.35 3089 0.0654

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


78
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types III Rolling Stock Cables
600/1000V Multicore Enhanced Wall Unsheathed Cables

A.Conductor B.Insulation

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of core Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
1 50.0 396/0.40 16.45 657 0.393
1 70.0 360/0.50 18.35 873 0.277
1 95.0 476/0.50 19.5 1108 0.210
1 150.0 756/0.50 24.1 1663 0.132
1 185.0 925/0.50 26.5 2024 0.108
1 240.0 1221/0.50 29.0 2598 0.0817
1 300.0 1525/0.50 31.0 3181 0.0654

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


79
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types VI Rolling Stock Cables
600/1000V Multicore Standard Wall Cables

A.Conductor B.Insulation C.Sheath

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107
Sheath
Cross linked EVA rubber type EM 104

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of core Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
10 2.5 50/0.25 28.1 1148 8.21
20 4.0 56/0.30 42.7 2421 5.09

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


80
Caledonian
RSE/STD/024 PART 6 Rolling Stock Cables
RSE/STD/024 Part 6 Types XI Rolling Stock Cables
600/1000V Singlepair Reduced Wall Screened Cables

A.Conductor B.Insulation C.Screen D.Sheath

Application
These cables are used as power and control cables for protected, fixed installation inside railway vehicles

Construction
Conductor
Flexible Stranded Tinned Copper
Insulation
Cross linked EPR rubber type EI 107
Screen
Copper Braid Screen
Sheath
Cross linked EPR rubbe type EM 107

Chemical & Environmental Properties


EN 60684-2 No fluorine
EN 50305; EN 60811-2-1 Resistance to oil & fuel
EN 50305 Resistance to ozone

Fire Performance for rolling stock application


EN 50306-2 Hazard levels HL1, HL2/HL3, HL4
DIN 5510-2 Protection level 1/2/3/4
BS 6853 Interior use 1a, 1b, II; Exterior use 1a, 1b, II
NF F 16-101 FO

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propogation for a single insulated wire/cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
Nominal Cross Nominal Diameter of Nominal Overall Maximum Conductor
Nominal Weight
No.of Pair Sectional Area Strands Diameter Resistance@20℃
mm2 No/mm mm kg/km Ω/km
1 1.0 37/0.18 7.3 76 20.0

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


81
Caledonian
NF F 63-808 Rolling Stock Cables
NF F 63-808 Thin Wall Unsheathed Single Core
250 V

A. Conductor B. Insulation

Application
These cables are used as signal and control cable for protected installations inside and outside of rail and transport
vehicles, where space and weight are an important factor, suitable for used in cable harnesses, switchboards and control
panels, driver desks etc

Construction
Conductor
Stranded tinned copper wires
IEC 60332-1/IEC 60332-3C


Insulation
Radiation crosslinkable LSZH compound

Electrical & Mechanical Properties


Nominal Voltage 250V Low Fire Load Iow
Maximum Conductor Temperature +105/+125℃
Temperature Range -40℃ ~105℃
Bending Radius 5×OD

Standards
NF F 63-808
NF F 16-101
BS 6853
DIN 5510

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propagation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

Nominal Cross Sectional Number & Nominal Overall Diameter


Weight
Area Diameter of Strands
Min. Max.
mm² No/mm mm mm kg/km
0.38 19/0.16 1.15 1.35 4.7
0.60 19/0.20 1.30 1.55 6.5
0.93 19/0.25 1.55 1.80 9.9
1.34 19/0.30 1.80 2.00 14.0
1.82 37/0.25 2.10 2.40 18.4
2.61 37/0.30 2.50 2.80 27.8
4.32 61/0.30 3.00 3.30 44.2

82
Caledonian
NF F 63-808 Rolling Stock Cables
NF F 63-808 Thin Wall Screened Single Core
250 V

A. Conductor B. Insulation C. Screen D. Sheath

Application
These cables are used as signal and control cable for protected installations inside and outside of rail and transport
vehicles, where space and weight are an important factor, suitable for used in cable harnesses, switchboards and control
panels, driver desks etc

Construction
Conductor IEC 60332-1/IEC 60332-3C

Stranded tinned copper wires 0°

Insulation
Radiation crosslinkable LSZH compound
Screen
Tinned copper braid Low Fire Load Iow

Sheath
Radiation crosslinkable LSZH compound

Electrical & Mechanical Properties


Nominal Voltage 250 V
Maximum Conductor Temperature +105/+125℃
Temperature Range -40℃ ~105℃
Bending Radius 5×OD

Standards
NF F 63-808
NF F 16-101
BS 6853
DIN 5510

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propagation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

83
Caledonian
NF F 63-808 Rolling Stock Cables

Nominal Cross Sectional Number & Nominal Overall Diameter


Weight
Area Diameter of Strands
Min. Max.
mm² No/mm mm mm kg/km
0.38 19/0.16 2.05 2.55 11.5
0.60 19/0.20 2.30 2.80 15.0
0.93 19/0.25 2.50 3.00 18.8
1.34 19/0.30 2.70 3.20 24.2
1.82 37/0.25 3.30 3.75 32.0
2.61 37/0.30 3.60 4.20 43.0
4.32 61/0.30 4.15 4.75 63.0

84
Caledonian
NF F 63-808 Rolling Stock Cables
NF F 63-808 Thin Wall Screened Multicore
250 V

A. Conductor B. Insulation C. Screen D. Sheath

Application
These cables are used as signal and control cable for protected installations inside and outside of rail and transport
vehicles, where space and weight are an important factor, suitable for used in cable harnesses, switchboards and control
panels, driver desks etc.

Construction
Conductor
Stranded tinned copper wires
Insulation
Radiation crosslinkable LSZH compound
Screen
Tinned copper braid
Sheath
Radiation crosslinkable LSZH compound

Electrical & Mechanical Properties


Nominal Voltage 250 V
Maximum Conductor Temperature +105/+125℃
Temperature Range -40℃ ~105℃
Bending Radius 5×OD

Standards
NF F 63-808
NF F 16-101
BS 6853
DIN 5510

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propagation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


85
Caledonian
NF F 63-808 Rolling Stock Cables

Nominal Cross Number & Nominal Overall Diameter


Number of Cores Weight
Sectional Area Diameter of Strands
Min. Max.
- mm² No/mm mm mm kg/km
2 0.38 19/0.16 3.20 4.00 20.0
2 0.60 19/0.20 3.70 4.50 32.0
2 0.93 19/0.25 4.25 5.05 39.5
2 1.34 19/0.30 4.80 5.60 54.0
2 1.82 37/0.25 5.55 6.35 66.0
2 2.61 37/0.30 6.35 7.15 87.0
2 4.32 61/0.30 7.50 8.30 128.0
3 0.38 19/0.16 3.55 4.35 30.0
3 0.60 19/0.20 4.00 4.80 39.0
3 0.93 19/0.25 4.50 5.30 55.0
3 1.34 19/0.30 5.10 5.90 66.0
3 1.82 37/0.25 4.80 6.60 84.0
3 2.61 37/0.30 6.80 7.60 117.0
3 4.32 61/0.30 8.10 8.90 182.0
4 0.38 19/0.16 4.05 4.85 39.0
4 0.60 19/0.20 4.50 5.30 51.0
4 0.93 19/0.25 5.00 5.80 70.0
4 1.34 19/0.30 5.70 6.50 89.0
4 1.82 37/0.25 6.45 7.25 109.0
4 2.61 37/0.30 7.65 8.45 157.0
4 4.32 61/0.30 9.05 9.85 237.0

86
Caledonian
NF F 63-826 Rolling Stock Cables
NF F 63-826 Standard Wall Unsheathed Single Core
500V, 1000V, 1500V, 3000V

A. Conductor B. Insulation
Application
These cables are used as power and control cable for protected installations inside and outside of rail and transport
vehicles, where handling and installation cost are an important factor, suitable for used in control, auxiliary and main circuit
wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction
Conductor
Stranded tinned copper wires to IEC 60228 Class 5 IEC 60332-1/IEC 60332-3C

Insulation 0°

Special halogen free compound

Electrical & Mechanical Properties


Nominal Voltage 500V, 1000V, 1500V, Low Fire Load Iow
3000V
Maximum Conductor Temperature +90/+105℃
Temperature Range -25℃ ~90℃
Bending Radius 4×OD

Standards
NF F 63-826
NF F 16-101
BS 6853

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propagation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index
500V
Nominal Cross Number & Nominal Nominal Insulation Overall Diameter
Weight
Sectional Area Diameter of Strands Thickness Min. Max.
mm² No/mm mm mm mm kg/km
1.0 32/0.20 1.3 3.8 4.5 26
1.5 30/0.25 1.3 4.1 4.8 33
2.5 50/0.25 1.3 4.5 5.2 43
4.0 56/0.30 1.3 5.0 5.8 59
6.0 84/0.30 1.4 5.7 6.5 82
10.0 80/0.40 1.5 6.9 8.1 135
16.0 126/0.40 1.5 8.2 9.2 210

87
Caledonian
NF F 63-826 Rolling Stock Cables
1000V
Nominal Cross Number & Nominal Nominal Insulation Overall Diameter
Weight
Sectional Area Diameter of Strands Thickness
Min. Max.
mm² No/mm mm mm mm kg/km
1.5 30/0.25 1.5 4.4 5.2 42
2.5 50/0.25 1.5 4.8. 5.6 55
4.0 56/0.30 1.5 5.4 6.2 72
6.0 84/0.30 1.6 6.1 6.9 96
10.0 80/0.40 1.6 7.0 8.3 154
16.0 126/0.40 1.6 8.3 9.4 218
25.0 196/0.40 1.7 9.8 11.0 316
35.0 276/0.40 1.8 11.2 12.5 440
50.0 396/0.40 1.9 13.0 14.3 580
70.0 360/0.50 2.0 14.7 16.3 830
95.0 475/0.50 2.0 16.6 18.4 1040
120.0 608/0.50 2.1 18.6 20.5 1310

1500V
Nominal Cross Number & Nominal Nominal Insulation Overall Diameter
Weight
Sectional Area Diameter of Strands Thickness
Min. Max.
mm² No/mm mm mm mm kg/km
1.5 30/0.25 2.3 6.0 6.8 59
2.5 50/0.25 2.3 6.4 7.2 73
4.0 56/0.30 2.3 7.0 7.8 91
6.0 84/0.30 2.3 7.5 8.3 120
10.0 80/0.40 2.3 8.4 9.7 160
16.0 126/0.40 2.3 9.7 10.8 235
25.0 196/0.40 2.3 11.0 12.2 330
35.0 276/0.40 2.4 12.4 13.7 480
50.0 396/0.40 2.5 14.2 15.5 610
70.0 360/0.50 2.7 16.1 17.7 860
95.0 475/0.50 2.7 18.0 19.8 1070
120.0 608/0.50 2.8 20.0 21.9 1340
150.0 756/0.50 2.8 21.8 23.8 1620
185.0 925/0.50 2.9 23.7 25.9 1940
240.0 1221/0.50 3.1 26.6 29.1 2550
300.0 1525/0.50 3.45 29.4 31.9 2950

3000V

Nominal Cross Number & Nominal Nominal Insulation Overall Diameter


Weight
Sectional Area Diameter of Strands Thickness
Min. Max.
mm² No/mm mm mm mm kg/km
2.5 50/0.25 3.1 8.0 8.8 94
4.0 56/0.30 3.1 8.5 9.5 124
6.0 84/0.30 3.1 8.8 9.9 135
10.0 80/0.40 3.1 10.0 11.3 200
16.0 126/0.40 3.1 11.2 12.4 265
25.0 196/0.40 3.1 12.5 13.8 375
35.0 276/0.40 3.2 13.9 15.3 493
50.0 396/0.40 3.3 15.7 17.2 680
70.0 360/0.50 3.4 17.5 19.1 930
95.0 475/0.50 3.5 19.5 21.4 1066
120.0 608/0.50 3.6 21.6 23.5 1530
150.0 756/0.50 3.6 23.3 25.5 1740
185.0 925/0.50 3.7 25.2 27.6 2100
240.0 1221/0.50 3.9 28.1 31.7 2460
300.0 1525/0.50 4.45 31.4 35.0 3050

88
Caledonian
NF F 63-826 Rolling Stock Cables
NF F 63-826 Standard Wall Sheathed Single Core
1500V, 3000V

A. Conductor B. Insulation C. Sheath

Application
These cables are used as power and control cable for protected installations inside and outside of rail and transport
vehicles, where handling and installation cost are an important factor, suitable for used in control, auxiliary and main circuit
wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction
Conductor
Stranded tinned copper wires to IEC 60228 Class 5
Insulation
Halogen free compound
Sheath
Halogen free compound

Electrical & Mechanical Properties


Nominal Voltage 1500V, 3000V
Maximum Conductor Temperature +90/+105℃
Temperature Range -25℃ ~90℃
Bending Radius 4×OD

Standards
NF F 63-826
NF F 16-101
BS 6853

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propagation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


89
Caledonian
NF F 63-826 Rolling Stock Cables
1500V
Number & Nominal Overall Diameter
Nominal Cross Nominal Sheath
Nominal Diameter Insulation Weight
Sectional Area Thickness
of Strands Thickness Min. Max.
mm² No/mm mm mm mm mm kg/km
1.5 30/0.25 2.3 1.5 8.9 9.9 130
2.5 50/0.25 2.3 1.5 9.3 10.3 145
10.0 80/0.40 2.3 1.8 11.9 13.3 290
50.0 396/0.40 2.5 2.2 18.3 20.3 850
120.0 608/0.50 2.8 2.6 25.0 27.5 1770
150.0 756/0.50 2.8 2.6 26.7 29.3 2150
185.0 925/0.50 2.9 2.8 29.0 31.8 2530

3000V
Nominal Overall Diameter
Nominal Cross Number & Nominal Nominal Sheath
Insulation Weight
Sectional Area Diameter of Strands Thickness
Thickness Min. Max.
mm² No/mm mm mm mm mm kg/km
150.0 756/0.50 3.6 2.6 28.2 30.9 2270
185.0 925/0.50 3.7 2.8 30.5 33.4 2660

90
Caledonian
NF F 63-826 Rolling Stock Cables
NF F 63-826 Standard Wall Unscreened Multicore
500V

A. Conductor B. Insulation C. Sheath

Application
These cables are used as power and control cable for protected installations inside and outside of rail and transport
vehicles, where handling and installation cost are an important factor, suitable for used in control, auxiliary and main circuit
wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction
Conductor
Stranded tinned copper wires to IEC 60228 Class 5
Insulation
Halogen free compound
Sheath
Halogen free compound

Electrical & Mechanical Properties


Nominal Voltage 500V
Maximum Conductor Temperature +90/+105℃
Temperature Range -25℃ ~90℃
Bending Radius 4×OD

Standards
NF F 63-826
NF F 16-101
BS 6853

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propagation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


91
Caledonian
NF F 63-826 Rolling Stock Cables
Number & Overall Diameter
Nominal Cross Nominal Sheath
Number of Cores Nominal Diameter Weight
Sectional Area Thickness
of Strands Min. Max.
- mm² No/mm mm mm mm kg/km
2 1.5 30/0.25 1.0 8.6 9.9 115
4 1.5 30/0.25 1.1 10.1 11.4 160
7 1.5 30/0.25 1.1 11.9 13.3 245
13 1.5 30/0.25 1.2 16.5 18.0 425
19 1.5 30/0.25 1.2 18.3 19.9 675
37 1.5 30/0.25 1.5 25.1 27.1 1170
2 2.5 50/0.25 1.1 10.0 11.3 185
4 2.5 50/0.25 1.2 11.7 13.1 275
13 2.5 50/0.25 1.4 19.5 21.1 750
19 2.5 50/0.25 1.4 21.6 23.4 980

92
Caledonian
NF F 63-826 Rolling Stock Cables
NF F 63-826 Extra-Flexible Standard Wall Unsheathed Single Core
1500V

A. Conductor B. Insulation

Application
These cables are used as power and control cable for protected installations inside and outside of rail and transport
vehicles, where handling and installation cost are an important factor, suitable for used in control, auxiliary and main circuit
wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction
Conductor
Stranded tinned copper wires to IEC 60228 Class 6
Insulation
Special halogen free compound

Electrical & Mechanical Properties


Nominal Voltage 1500V
Maximum Conductor Temperature +90/+105℃
Temperature Range -25℃ ~90℃
Bending Radius 3×OD

Standards
NF F 63-826
NF F 16-101
BS 6853

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propagation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


93
Caledonian
NF F 63-826 Rolling Stock Cables

Nominal Cross Number & Nominal Nominal Insulation Overall Diameter


Weight
Sectional Area Diameter of Strands Thickness
Min. Max.
mm² No/mm mm mm mm kg/km
10.0 320/0.20 2.3 8.4 9.5 187
16.0 512/0.20 2.3 9.7 10.8 266
25.0 800/0.20 2.3 11.0 12.2 354
35.0 1120/0.20 2.4 12.4 13.7 440
50.0 705/0.30 2.5 14.2 15.5 613
70.0 990/0.30 2.7 16.1 17.7 875
95.0 1340/0.30 2.7 18.0 19.8 1045
120.0 1690/0.30 2.8 20.0 21.9 1350
150.0 2123/0.30 2.8 21.8 23.8 1650
185.0 1470/0.40 2.9 23.7 25.9 2130

94
Caledonian
NF F 63-827 Rolling Stock Cables
NF F 63-827 High Temperature Unsheathed Single Core
3000V

A. Conductor B. Insulation

Application
These cables are used as power and control cable for protected installations inside and outside of rail and transport
vehicles, where handling and installation cost are an important factor, suitable for used in control, auxiliary and main circuit
wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction
Conductor
Stranded tinned copper wires to IEC 60228 Class 5
Separator
Polyester tape
Insulation
Silicone halogen free rubber

Electrical & Mechanical Properties


Nominal Voltage 3000V
Maximum Conductor Temperature +120/+140℃
Temperature Range -40℃ ~135℃
Bending Radius 4×OD

Standards
NF F 63-827
NF F 16-101

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propagation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


95
Caledonian
NF F 63-827 Rolling Stock Cables

Nominal Cross Number & Nominal Nominal Insulation Overall Diameter


Weight
Sectional Area Diameter of Strands Thickness
Min. Max.
mm² No/mm mm mm mm kg/km
2.5 50/0.25 2.3 6.4 7.2 65
4.0 56/0.30 2.3 7.0 7.8 85
6.0 84/0.30 2.3 7.5 8.3 108
10.0 80/0.40 2.3 8.4 9.5 160
16.0 126/0.40 2.3 9.7 10.8 230
25.0 196/0.40 2.3 11.0 12.2 310
35.0 276/0.40 2.4 12.2 13.5 420
50.0 396/0.40 2.5 14.2 15.5 580
70.0 360/0.50 2.7 16.1 17.7 790
95.0 475/0.50 2.7 18.0 19.8 1030
120.0 608/0.50 2.8 20.0 21.9 1250
150.0 756/0.50 2.8 21.8 23.8 1560
185.0 925/0.50 2.9 23.7 25.9 1880
240.0 1221/0.50 3.1 26.6 29.1 2420

96
Caledonian
NF F 63-827 Rolling Stock Cables
NF F 63-827 Extra-Flexible High Temperature Sheathed Single Core
3000V

A. Conductor B. Insulation C. Sheath

Application
These cables are used as power and control cable for protected installations inside and outside of rail and transport
vehicles, where handling and installation cost are an important factor, suitable for used in control, auxiliary and main circuit
wiring such as cable harnesses, switchboards and control panels, driver desks etc.

Construction
Conductor
Stranded tinned copper wires to IEC 60228 Class 6
Insulation
Silicone halogen free rubber
Reinforcement
Textile braid
Sheath
Silicone halogen free rubber

Electrical & Mechanical Properties


Nominal Voltage 3000V
Maximum Conductor Temperature +120/+140℃
Temperature Range -40℃ ~135℃
Bending Radius 3×OD

Standards
NF F 63-827
NF F 16-101

Fire Performance in general


EN 50265-2-1; IEC 60332-1; BS 4066-1 Vertical flame propagation for a single insulated wire or cable
EN 50266-2-4 + EN 50305; IEC 60332-3C; Fire propagation of bunched wires and cables;
VDE 0472 Teil 804; BS 4066-3; NFC 32070
EN 50268-2; IEC 61034-2; VDE 0472 Teil 816 Smoke density
EN 50267-2-1; IEC 60754-1; VDE 0472 Teil 815 Halogen Free
EN 50267-2-2/3; IEC 60754-2; VDE 0472 Teil 813 Corrosivity of gases (Acidity & Conductivity)
EN 50305; NFX 70-100; NFF 63808; TM1-04; BS6853 Toxicity index
NFF 16101; NFF 63808; BS6853 Smoke index

IEC 60332-1/IEC 60332-3C

Low Fire Load Iow


97
Caledonian
NF F 63-827 Rolling Stock Cables

Nominal Cross Number & Nominal Nominal Insulation Overall Diameter


Weight
Sectional Area Diameter of Strands Thickness
Min. Max.
mm² No/mm mm mm mm kg/km
25.0 800/0.20 2.8 12.0 13.2 390
35.0 1120/0.20 2.8 13.2 14.7 500
50.0 705/0.30 3.0 15.2 16.7 680
70.0 990/0.30 3.2 17.1 18.8 930
95.0 1340/0.30 3.2 19.0 21.0 1150
120.0 1690/0.30 3.3 21.0 23.1 1470
150.0 2123/0.30 3.3 22.8 25.0 1800
185.0 1470/0.40 3.4 24.7 27.1 2240
240.0 1905/0.40 3.6 27.6 31.2 2820

98