HT7051 Insulation Meter Specifications

The document describes an insulation meter that can measure up to 5kVDC. It provides specifications for voltage measurement range and accuracy, insulation resistance measurement range and accuracy, generated test voltage levels and accuracy, test current levels, and measurement ranges and accuracy for leakage current, polarization index, dielectric absorption ratio, capacitance, and environmental specifications. It also lists general characteristics of the device including its display, memory, interface, power supply, battery life, environment tolerances, mechanical dimensions, certifications, and safety guidelines.

Uploaded by

Muaf Faizudeen
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
256 views3 pages

HT7051 Insulation Meter Specifications

The document describes an insulation meter that can measure up to 5kVDC. It provides specifications for voltage measurement range and accuracy, insulation resistance measurement range and accuracy, generated test voltage levels and accuracy, test current levels, and measurement ranges and accuracy for leakage current, polarization index, dielectric absorption ratio, capacitance, and environmental specifications. It also lists general characteristics of the device including its display, memory, interface, power supply, battery life, environment tolerances, mechanical dimensions, certifications, and safety guidelines.

Uploaded by

Muaf Faizudeen
Copyright
© Attribution Non-Commercial (BY-NC)
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

HT7051 Rel.1.

01 of 12/09/2008

Professional insulation meter up to 5kVDC Pag 1 of 3

1. ELECTRICAL SPECIFICATION
Uncertainty is indicated as ± (% rdgs + no. of dgt) at 23°C ± 5°C, con relative humidity <80%HR

DC/AC TRMS VOLTAGE


Range Resolution Uncertainty Overload protection
10 ÷ 660V 1V ±(2%rdg+2dgt) CAT IV 600 to ground

INSULATION RESISTANCE
Range Test Voltage Resolution Uncertainty (*)
0.01MΩ ÷ 0.19MΩ ±(5%rdg + 7dgt)
≥ 100V DC
0.20MΩ ÷ 199GΩ Test Voltage
0.20MΩ ÷ 499GΩ ≥ 250V DC ±(5%rdg.+3dgt) if Rmis ≤
0.20MΩ ÷ 999GΩ ≥ 500V DC ≤1%rdg 5nA
0.20MΩ ÷ 1.99TΩ ≥ 1000V DC
Test Voltage
0.20MΩ ÷ 4.99TΩ ≥ 2500V DC ±(20%rdg.+3dgt) if Rmis >
0.20MΩ ÷ 9.99TΩ 5000V DC 5nA
(*) Load Capacitance < 1nF

GENERATED TEST VOLTAGE (compliance to IEC/EN61557-2)


Test mode Nominal test voltage Uncertainty
FIX 100V,250V,500V,1kV, 2.5kV, 5kV
100 ÷ 1kV in steps of 25V
AJUSTABLE
1kV ÷ 5kV in steps of 50V -0%, +10% +15V
100 ÷ 1kV in steps of 25V
RAMP
1kV ÷ 5kV in steps of 50V

TEST CURRENT
Test Voltage Test current
100 ÷ 5000V 1mA ≤ Test Current ≤ 3mA (**)
(**) Test current automatically controlled.

TEST TIME
Setting Range Resolution
5s – 99min 59s 1s

CAPACITANCE
Range Resolution Resistance Load Test Voltage (Vn) Uncertainty
1nF ÷ 999nF 1nF
Vn ≤ 5kV
1.00µF ÷ 5.00µF 0.01µF
1nF ÷ 999nF 1nF
1.00µF ÷ 9.99µF 0.01µF Vn ≤ 2.5kV
≥ 5MΩ ±(10%rdg+5dgt)
10.0µF ÷ 19.9µF 0.1µF
1nF ÷ 999nF 1nF
1.00µF ÷ 9.99µF 0.01µF Vn ≤ 1kV
10.0µF ÷ 49.9µF 0.1µF
Capacitor charge time (OVÆ 5000V): < 3s x 1µF
Capacitor discharge time (5000VÆ 25V): < 5s x 1µF

HT ITALIA srl Tel: +39-0546-621002 - Fax: +39-0546-621144


Via della Boaria 40 - 48018 Faenza (RA)- Italy email: [email protected] - web: http://www.htitalia.com
HT7051 Rel.1.01 of 12/09/2008

Professional insulation meter up to 5kVDC Pag 2 of 3

LEAKAGE CURRENT
Range Resolution Uncertainty
1nA ÷ 99.9nA 0.1nA Test Voltage
100nA ÷ 999nA 1nA ±(7%rdg+3dgt) if Rmis ≤
1.00µA ÷ 9.99µA 0.01µA 5nA
10.0µA ÷ 9.99µA 0.1µA
Test Voltage
100µA ÷ 999µA 1µA ±(22%rdg+3dgt) if Rmis >
1.00mA ÷ 2.5mA 0.01mA 5nA

P.I (Polarization Index) – D.A.R (Dielectric Absorption Ratio)


Range Resolution Uncertainty
Test Voltage
±(5%rdg+3dgt) if Rmis ≤
5nA
0.01 ÷ 9.99 0.01
Test Voltage
±(20%rdg+3dgt) if Rmis >
5nA
(*) Load Capacitance < 1nF

HT ITALIA srl Tel: +39-0546-621002 - Fax: +39-0546-621144


Via della Boaria 40 - 48018 Faenza (RA)- Italy email: [email protected] - web: http://www.htitalia.com
HT7051 Rel.1.01 of 12/09/2008

Professional insulation meter up to 5kVDC Pag 3 of 3

2. GENERAL CHARACTERISTICS
DISPLAY, MEMORY, SERIAL INTERFACE
• Backlight LCD with three simultaneous readings:
Group 1 (main) Æ Insulation Resistance, Leakage Current, PI, DAR, Capacitance
Group 2 Æ Test voltage (nominal and generated)
Group 3 Æ Test Time
• Bargraph: 32 segments
• Low battery indications
• Memory: 700 test
• Communication interface: RS232 optoinsulated

POWER SUPPLY:
• Internal battery charger, power supply: 220-240V 50/60Hz, 20VA
• Internal NiMH rechargeable battery
• Protection fuse on power supply: T 200mA/250V, Ir: 1.5kA
• Low battery indication: symbol at display
• Battery life: >1000 Test @ 5kV on 5MΩ (test time: 5s, delay between two test: 25s)
according to IEC/EN61557-2. (par. 6.7)
• AutoPowerOFF: after 5min since last operation

ENVIRONMENT:
• Ref. Temperature: 23°C ± 5°C
• Working temperature: 0° ÷ 40°C
• Maximum relative humidity: < 80%UR
• Storage temperature: -10 ÷ 60°C
• Storage humidity: < 80%UR

MECHANICAL DATA:
• Dimensions: 360(L) x 310(W) x 195(H) mm
14.2‘’ (L) x 12.2’’(W) x 7.7’’(H)
• Weight: about 3.5kg
about 7.8lv

GUIDELINES
Instrument’s safety IEC/EN61010-1, IEC/EN61557-1, IEC/EN61557-2
Technical documentatiion : IEC/EN61187
Accessories safety : IEC/EN61010-031
Insulation: Double insulation
Type of Protection: 2
Mechanical protection: IP40 (open case), IP53 (closed case)
Over voltage category: CAT IV 600V to ground, max 600V between inputs
Maximum altitude max altitude 2000m
Patented certification: TÜV protocol conformity

This instrument complies with the requirements of the European Low Voltage Directives 2006/95/EEC
(LVD) and EMC 2004/108/EEC

HT ITALIA srl Tel: +39-0546-621002 - Fax: +39-0546-621144


Via della Boaria 40 - 48018 Faenza (RA)- Italy email: [email protected] - web: http://www.htitalia.com