This document provides information on DQM-II series explosion-proof cable glands. The glands are approved for use in hazardous zones and provide gas and dust explosion protection. Tables are included specifying the technical details and dimensions for different gland sizes to accommodate a range of cable and pipe diameters.

Uploaded by

Lucas Moreno
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
144 views2 pages

DQM Ii

This document provides information on DQM-II series explosion-proof cable glands. The glands are approved for use in hazardous zones and provide gas and dust explosion protection. Tables are included specifying the technical details and dimensions for different gland sizes to accommodate a range of cable and pipe diameters.

Uploaded by

Lucas Moreno
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

CABLE GLANDS & BUSHINGS CABLE GLANDS & BUSHINGS

Cable Glands Cable Glands


DQM-II Series Explosion-proof Cable Glands (Ex d IIC Ex e IIC) DQM-II Series Explosion-proof Cable Glands (Ex d IIC Ex e IIC)
Unarmored Single Seal Unarmored Single Seal
◆ Explosion protection to
Selection table of cable wiring
-CENELEC
Cable outer Minimum Nominal Across Across
-IEC Gland Entry thread “A” Ordering Weight
diameter B (mm) thread length protrusion flats corners
size code (kg)
-NEC Metric NPT G Min Max C (mm) length D (mm) E (mm) F (mm)
◆ Can be used in 20 M20 1/2" 1/2" 6.5 10 16 37 30 34 708001 0.15
Zone 1 and Zone 2
25 M25 3/4" 3/4" 10 14 16 40 36 41 708002 0.20
Zone 21 and Zone 22
Class I, Zone 1 and Zone 2 32 M32 1" 1" 11 18 16 40 41 46 708003 0.30

Class I, Division 1, Groups A , B, C, D 40 M40 1 1/4" 1 1/4" 14 23 16 45 50 55 708004 0.45


◆ Ex d, Ex e structure; available in stainless steel, nickel plated
50 M50 1 1/2" 1 1/2" 20 27 16 50 60 65 708005 0.70
Cable wiring brass or galvanized carbon steel.
63 M63 2" 2" 25 34 16 57 70 75 708006 0.90
◆ Single seal, suitable for unarmored cable.
Steel pipe wiring 75 M75 2 1/2" 2 1/2" 38 57 19 65 102 110 708007 2.30

90 M90 3" 3" 55 67 19 85 110 115 708008 2.50

115 M115 4" 4" 48 80 19 105 140 145 708009 4.60

Selection table of steel pipe wiring


Entry Entry Cable outer Minimum Nominal Across Across
Gland thread “A” thread “H” diameter B (mm) thread length protrusion Ordering Weight
flats corners
Technical data size code (kg)
Metric NPT G Metric NPT G Min Max C (mm) length D (mm) E (mm) F (mm)
Explosion-proof cable glands DQM-II (unarmored single seal)
20 M20 1/2" 1/2" M20 1/2" 1/2" 10 14 15 51 31 33 708010 0.20
Explosion protection
25 M25 3/4" 3/4" M25 3/4" 3/4" 12 17 15 51 38 40 708011 0.25
Gas explosion protection II 2 G Ex d IIC Gb II 2 G Ex e IIC Gb
Dust explosion protection II 2 D Ex tb IIIC Db IP66 32 M32 1" 1" M32 1" 1" 15 22 19 65 45 48 708012 0.40
Certificates LCIE 06 ATEX 6100X; IECEx LCI 08.0011X; RU C-CN.ГБ05.B.00345(CU-TR)
40 M40 1 1/4" 1 1/4" M40 1 1/4" 1 1/4" 20 30 19 68 60 63 708013 0.60
KZ.7500525.22.01.00376 (CU-TR)
Conformity to standards EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-31 50 M50 1 1/2" 1 1/2" M50 1 1/2" 1 1/2" 26 37 19 68 70 75 708014 0.75
IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-31 63 M63 2" 2" M63 2" 2" 30 47 19 73 82 85 708015 1.15
Gland material Stainless steel, nickel plated brass or galvanized carbon steel
75 M75 2 1/2" 2 1/2" M75 2 1/2" 2 1/2" 38 57 19 73 102 110 708016 1.50
Degree of protection IP66 (IP67 optional)
Ambient temperature -60℃~+100℃ 90 M90 3" 3" M90 3" 3" 55 67 19 73 110 115 708017 1.80
Connection thread Metric thread is standard type; G thread or NPT thread is optional 115 M115 4" 4" M115 4" 4" 48 80 19 78 140 145 708018 3.50

Note: 1. Standard material is galvanized carbon steel. Nickel plated brass or stainless steel is optional. Above weight is based
D C E upon galvanized carbon steel.
2. Earth lug and shroud on request. See P7/32~33.
3. Metric threads are 1.5mm pitch as standard, others thread pitch can be customized, please specify when ordering.
A
B

Cable wiring

D C E
H

A
B

Steel pipe wiring

20 | [Link] AS / RIGHT THE FIRST TIME [Link] [Link] RIGHT THE FIRST TIME / [Link] AS | 21
6 6
CABLE GLANDS & BUSHINGS CABLE GLANDS & BUSHINGS
Cable Glands Cable Glands
DQM-II Series Explosion-proof Cable Glands (Ex d IIC Ex e IIC) DQM-II Series Explosion-proof Cable Glands (Ex d IIC Ex e IIC)
Armored Dual Seal Armored Dual Seal

◆ Explosion protection to
Selection table of cable wiring
-CENELEC
Cable outer diameter B (mm) Cable outer Minimum Nominal Across Range of
diameter Across
-IEC Gland Entry thread “A” thread protrusion armored Ordering Weight
Standard Seal Alternative Seal C (mm) flats corners thickness code
size length length (kg)
-NEC F (mm) G (mm) h (mm)
Metric NPT G Min Max Min Max Min Max D (mm) E (mm)
◆ Can be used in 20A M20 1/2" 1/2" 4.0 8.0 - - 5.5 12.0 15 59 27 30 0.3~1.0 709001 0.12
Zone 1 and Zone 2 20B M20 1/2" 1/2" 6.5 10.5 - - 9.5 16.0 15 59 27 30 0.3~1.0 709002 0.15
Zone 21 and Zone 22 20C M20 1/2" 1/2" 10 14.5 8.5 13.0 12.5 20.5 15 61 32 35 0.3~1.0 709003 0.15
25A M25 3/4" 3/4" 6.5 10.5 - - 9.5 16.0 15 59 34 37 0.3~1.0 709004 0.15
Class I, Zone 1 and Zone 2
25B M25 3/4" 3/4" 10.0 14.5 8.5 13.0 12.5 20.5 15 61 34 37 0.3~1.0 709005 0.19
Class I, Division 1, Groups A , B, C, D 25C M25 3/4" 12.5 19.5 9.5 15.5 17.0 26.0 15 68 41 45 0.4~1.2 709006 0.18
3/4"
◆ Ex d, Ex e structure; available in stainless steel, nickel plated 32A M32 1" 1" 10 14.5 8.5 13.0 12.5 20.5 19 61 41 45 0.4~1.2 709007 0.18
brass or galvanized carbon steel. 32B M32 1" 1" 12.5 19.5 9.5 15.5 17.0 26.0 19 68 41 45 0.4~1.2 709008 0.22
◆ Dual seal, suitable for both armored and unarmored cable. 32C M32 1" 1" 19 25.5 14.5 21.0 22.0 33.0 19 76 49 54 0.4~1.4 709009 0.30
Cable wiring 40A M40 1 1/4" 1 1/4" 12.5 19.5 9.5 15.5 17.0 26.0 19 68 49 54 0.4~1.4 709010 0.30
40B M40 1 1/4" 1 1/4" 19.0 25.5 14.5 21.0 22.0 33.0 19 76 49 54 0.6~1.9 709011 0.40
40C M40 1 1/4" 1 1/4" 25.0 32.0 22.0 28.0 28.0 41.0 19 83 60 65 0.6~2.2 709012 0.40
Steel pipe wiring
50A M50 1 1/2" 1 1/2" 19.0 25.5 14.5 21.0 22.0 33.0 19 76 60 65 0.6~2.2 709013 0.40
50B M50 1 1/2" 1 1/2" 25.0 32.0 22.0 28.0 28.0 41.0 19 83 60 65 0.8~2.3 709014 0.60
50C M50 1 1/2" 1 1/2" 31.5 39.0 27.5 35.0 36.0 52.5 19 101 72 77 0.8~2.3 709015 0.80
63A M63 2" 2" 25.0 32.0 22.0 28.0 28.0 41.0 19 83 72 77 0.8~2.3 709016 0.90
63B M63 2" 2" 31.5 39.0 27.5 35.0 36.0 52.5 19 101 72 77 0.9~2.4 709017 1.00
63C M63 2" 2" 42.5 50.0 39.0 46.5 46.0 65.0 19 112 86 93 0.9~2.4 709018 1.20
75A M75 2 1/2" 2 1/2" 31.5 39.0 27.5 35.0 36.0 52.5 19 101 84 90 0.9~2.4 709019 2.50
Technical data 75B M75 2 1/2" 2 1/2" 42.5 55.5 39.0 46.5 46.0 65.0 19 112 86 93 0.9~2.4 709020 2.80
Explosion-proof cable glands DQM-II (armored dual seal) 75C M75 2 1/2" 2 1/2" 54.5 64.0 48.5 58.0 57.0 78.0 19 119 102 110 0.9~2.4 709021 2.90
90 M90 3" 3" 63.0 75.0 - - 68.0 88.0 19 121 112 121 0.9~2.4 709022 3.90
Explosion protection 115 M115 4" 4" 75.0 90.0 - - 83.0 103.0 19 126 127 137 0.9~2.8 709023 4.55
Gas explosion protection II 2 G Ex d IIC Gb II 2 G Ex e IIC Gb
Dust explosion protection II 2 D Ex tb IIIC Db IP66
Selection table of steel pipe wiring
Certificates LCIE 06 ATEX 6100X; IECEx LCI 08.0011X; RU C-CN.ГБ05.B.00345(CU-TR)
Entry Entry Cable outer diameter B (mm) Cable outer Minimum Nominal Range of
KZ.7500525.22.01.00376 (CU-TR) diameter Across Across
Gland thread “A” thread “H” thread protrusion armored Ordering Weight
Standard Seal Alternative Seal C (mm) flats corners thickness code
Conformity to standards EN 60079-0, EN 60079-1, EN 60079-7, EN 60079-31 size length length (kg)
Metric NPT G Metric NPT G Min Max Min Max Min Max D (mm) E (mm) F (mm) G (mm) h (mm)
IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 60079-31
20A M20 1/2" 1/2" M20 1/2" 1/2" 4.0 8.0 - - 5.5 12.0 15 74 27 30 0.3~1.0 709024 0.15
Gland material Stainless steel, nickel plated brass or galvanized carbon steel
20B M20 1/2" 1/2" M20 1/2" 1/2" 6.5 10.5 - - 9.5 16.0 15 74 27 30 0.3~1.0 709025 0.20
Degree of protection IP66 (IP67 optional)
20C M20 1/2" 1/2" M25 3/4" 3/4" 10 14.5 8.5 13.0 12.5 20.5 15 96 32 35 0.3~1.0 709026 0.20
Ambient temperature -60℃~+100℃ 25A M25 3/4" 3/4" M20 1/2" 1/2" 6.5 10.5 - - 9.5 16.0 15 74 34 37 0.3~1.0 709027 0.20
Connection thread Metric thread is standard type; G thread or NPT thread is optional. 25B M25 3/4" 3/4" M25 3/4" 3/4" 10.0 14.5 8.5 13.0 12.5 20.5 15 76 34 37 0.3~1.0 709028 0.24
25C M25 3/4" 3/4" M32 1" 1" 12.5 19.5 9.5 15.5 17.0 26.0 15 83 41 45 0.4~1.2 709029 0.27
32A M32 1" 1" M25 3/4" 3/4" 10 14.5 8.5 13.0 12.5 20.5 19 76 41 45 0.4~1.2 709030 0.28
E D F
h 32B M32 1" 1" M32 1" 1" 12.5 19.5 9.5 15.5 17.0 26.0 19 87 41 45 0.4~1.2 709031 0.27
32C M32 1" 1" M40 1 1/4" 1 1/4" 19 25.5 14.5 21.0 22.0 33.0 19 95 49 54 0.4~1.4 709032 0.33
40A M40 1 1/4" 1 1/4" M32 1" 1" 12.5 19.5 9.5 15.5 17.0 26.0 19 87 49 54 0.4~1.4 709033 0.33
40B M40 1 1/4" 1 1/4" M40 1 1/4" 1 1/4" 19.0 25.5 14.5 21.0 22.0 33.0 19 95 49 54 0.6~1.9 709034 0.36
40C M40 1 1/4" 1 1/4" M50 1 1/2" 1 1/2" 25.0 32.0 22.0 28.0 28.0 41.0 19 103 60 65 0.6~2.2 709035 0.45
C

A
B

50A M50 1 1/2" 1 1/2" M40 1 1/4" 1 1/4" 19.0 25.5 14.5 21.0 22.0 33.0 19 95 60 65 0.6~2.2 709036 0.45
50B M50 1 1/2" 1 1/2" M50 1 1/2" 1 1/2" 25.0 32.0 22.0 28.0 28.0 41.0 19 103 60 65 0.8~2.3 709037 0.70
50C M50 1 1/2" 1 1/2" M63 2" 2" 31.5 39.0 27.5 35.0 36.0 52.5 19 118 72 77 0.8~2.3 709038 0.85
63A M63 2" 2" M50 1 1/2" 1 1/2" 25.0 32.0 22.0 28.0 28.0 41.0 19 103 72 77 0.8~2.3 709039 1.20
Cable wiring
63B M63 2" 2" M63 2" 2" 31.5 39.0 27.5 35.0 36.0 52.5 19 118 72 77 0.9~2.4 709040 1.50
63C M63 2" 2" M75 2 1/2" 2 1/2" 42.5 50.0 39.0 46.5 46.0 65.0 19 131 86 93 0.9~2.4 709041 1.80
E D F
75A M75 2 1/2" 2 1/2" M63 2" 2" 31.5 39.0 27.5 35.0 36.0 52.5 19 118 84 90 0.9~2.4 709042 2.80
h 75B M75 2 1/2" 2 1/2" M75 2 1/2" 2 1/2" 42.5 55.5 39.0 46.5 46.0 65.0 19 131 86 93 0.9~2.4 709043 3.10
75C M75 2 1/2" 2 1/2" M90 3" 3" 54.5 64.0 48.5 58.0 57.0 78.0 19 138 102 110 0.9~2.4 709044 3.50
90 M90 3" 3" M115 4" 4" 63.0 75.0 - - 68.0 88.0 19 140 112 121 0.9~2.4 709045 4.10
115 M115 4" 4" M125 4 1/2" 4 1/2" 75.0 90.0 - - 83.0 103.0 19 145 127 137 0.9~2.8 709046 4.90
H

A
C

Note: 1. Standard material is nickel plated brass. Stainless steel or galvanized carbon steel is optional. Above weight is based
upon nickel plated brass.
2. Earth lug and shroud on request. See P7/32~33.
Steel pipe wiring 3. Metric threads are 1.5mm pitch as standard, others thread pitch can be customized, please specify when ordering.

6/22 | [Link] AS / RIGHT THE FIRST TIME [Link] [Link] RIGHT THE FIRST TIME / [Link] AS | 6/23

You might also like