D.
Mechanical fittings, when used, shall be specifically designed for, or tested and found to be acceptable for
use with HDPE pipe.
E. Fittings used to connect with dissimilar pipe materials shall be provided as per Section 15062 "Ductile Iron
Pipe and Fittings."
PART 3 - EXECUTION
3.1 PIPING APPLICATIONS
A. Transition and special fittings with pressure ratings at least equal to piping pressure ratings may be used in
applications below, unless otherwise indicated.
Comply for
C. Aboveground, Soil, Waste and Rain Water Piping and under building sewer piping: Use Non
Pressure UPVC piping with solvent cement joint for DN50 and push fit joint for DN75 and above.
Misr El Hegaz
D. Underground or under tiles Soil, Waste and Rain Water Piping and under building sewer piping: Use Non
Pressure UPVC piping with solvent cement joint for DN50 and push fit joint for DN75 and above.
E. Vent pipe: UPVC
F. Force Pipe: pressure pipe UPVC PN16
Misr Elhegaz For pipe and plastic products
Compliance sheet
project
Contractor
Consultant
UPVC non-pressure pipes and fittings shall be manufactured and tested to DIN 19534
standard & product
for pipes underground and DIN 19531 for pipes used in drainage system inside
descriptions
buildings; and to BS 3505 for pressure pipes
Standard DIN 19534 & BS 3505 & DIN 19531
Test Requirements Results evalutions
PVC non-pressure pipes and fittings shall be manufactured and tested to DIN 19534
for pipes underground and DIN 19531 for pipes used in drainage system inside
buildings; and to BS 3505 for pressure pipes
Dimensional :- must be comply with all dimansion
General according to DIN 19534
The pipe and fitting shall be homogeneous throughout for pipes underground and DIN 19531
and free of visible cracks , foreign inclusions , or other for pipes used in drainage system pass
injurious defects , the pipe shall be as uniform as inside
commerically practicable in color , opacity , density and buildings; and to BS 3505 for pressure
other physical properties . pipes
≤ 3 % Original appearance of the pipe
Heat reversion pass ( 2% )
shall remain.
Comply with all speces of the
When testing as in 6.4.2 the True following standards :
Impact Rate (TIR) shall not be greater DIN 19534 & DIN 19531
Impact strength No faluir BS 3505
than 10 %
Resistance to dichleromethan Testing shall be as in DIN EN 580. No faluir
Compound density ≥ 1.4 : 1.47 kg/m3 pass ( 1.46 kg/m3 )
No failure during test period of any test
Hydrostatic pressure resistance at 20 C⁰ at 420 M. Pa pieces pass
Durations time : 1 hour
Eng .Yasser El-Kady
Sales director
UPVC & HDPE sector
Misr El Hegaz
0
Misr Elhegaz For pipe and plastic products
Compliance sheet
project
Contractor
Consultant
Material type UPVC pipes according to EOS 1717 & DIN 19534& DIN 8062 & DIN 8061 & ISO EN 1452 & EOS 848
Standard DIN 8061 / 8062
Product Description UPVC pipes
Test Requirements Results evalutions
UPVC pipes according to EOS 1717 & DIN 19534& DIN 8062 & DIN 8061 & ISO EN 1452 & EOS 848
Dimensional :-
General
must be comply with all dimansion
The pipe and fitting shall be homogeneous throughout
according to EOS 1717 & DIN 19534&
and free of visible cracks , foreign inclusions , or other pass
DIN 8062 & DIN 8061 & ISO EN 1452 &
injurious defects , the pipe shall be as uniform as
EOS 848
commerically practicable in color , opacity , density and
other physical properties .
≤ 3 % Original appearance of the pipe
Heat reversion pass ( 2% )
shall remain.
compy dimansion according to EOS
When testing as in 6.4.2 the True 1717 & DIN 19534& DIN 8062 & DIN
Impact Rate (TIR) shall not be greater 8061 & ISO EN 1452 & EOS 848
Impact strength No faluir
than 10 %
Resistance to dichleromethan Testing shall be as in DIN EN 580. No faluir
Compound density ≥ 1.4 : 1.47 kg/m3 pass ( 1.46 kg/m3 )
No failure during test period of any test
Hydrostatic pressure resistance at 20 C⁰ pass
pieces
Yasser elkady
Sales technical support director
Misr Elhegaz For pipe and plastic products
Compliance sheet
project ------------------------------------------------------------
Contractor -------------------------------------------------------------
Consultant -----------------------------------------------------------------
Material type UPVC
Standard ASTM D 2665
Poly(Vinyl Chloride) (PVC) Plastic Drain, Waste, and Vent
Test Requirements Results evalutions
the pipe and fittings shall be homogeneous
throughout and free of visible cracks, holes, foreign
inclusions,
General or other injurious defects. The pipe shall be as 1- pipes & fitting free from visible crack , holes , foreign inclusions or
uniform as other r injurious defects comply
commercially practicable in color, opacity, density, 2- the pipes & fitting comply with all general physical properties .
and other
physical [Link] be comply with all general
requirments
out utside Diameter. The outside diameter and wall thicknesses of pipe
shall meet the requirements of Table 2.
The patterns, dimensions, and laying lengths of
Out - of-Roundness fittings, including adaptors, shall meet the requirements of
Specification D3311 and Table 1.
Dimensions and Mean wall thickness (ovality) and tolerances The patterns, dimensions, and laying lengths ofShort-Pattern fittings Comply
Tolerances Socket entrance Diameter shall meet the requirements of Specification F2135.
all fittings having taper pipe threads, threads
shall conform to Specification F1498 and be gaged in accordance with
Fitting & taper pipe threads
7.5. Fittings of nominal sizes not given in Specification F1498 shall not
have threads
Fabricated DWV fittings shall comply with Specification F1866.
Fabricated DWV fitting
Deflection Load and Flattening:
-Pipe : The minimum pipe stiffness at 5 %
deflectionshall be in accordance with Table 3.
The pipe shall deflect by60 % of the nominal
outside diameter (flattening) without cracking,
Pipes Stiffness rupture. pass comply
Fittings : Individual fittings unassembled shall
withstand a minimum load of 750 lbf/ft (11
kN/m) of centerlinelength without cracking or
other visible evidence of failure
The minimum impact resistance of All pipe sizes (81) (J) 73°F (23°C)
Fitting sizes and types
pipe and fittings, when tested at the time of
Impact Resistance (larger than 2 in. nominal OD) = 23 j 73°F (23°C). comply
manufacture, shall Fitting sizes and types (2 in. and smaller nonimal OD) = 12 j 73°F
comply with Table 4 (23°C)
Tensile strength ≥ 45 N/mm2 ≥ 52 N/mm2 comply
Compound density ≥ 1.39 kg/m3 pass ( 1.39 kg/m3 )
comply
Thermal expansion for installations
Thermal Expansion subject to temperature changes may be pass comply
determined from Table TABLE X1.1
Eng .Yasser elkady
Sales director for pipes sector
01002555120