KONE KCE Parameters Instelbaar Third Party
KONE KCE Parameters Instelbaar Third Party
10
408 Stuck Button Service Interval 1 30 Stuck call buttons service interval in minutes.
516 Door Open Time 10 600 Basic door open time in 0.1s steps
517 Door Open Time Main Add 0 300 Additional door time at main floor in 0,1 s steps
518 Door Open Time Ldg Add 0 300 Additional door time to landing call in 0,1 s steps
519 Door Reopen Time 1 150 Door reopen time in 0,1 s steps
524 Door Ensured Time For SRC 1 100 Ensured door open time after photocell cut in 0,1 s steps
525 Door Ensured Time For QCC 1 100 Ensured door open time after new car call in 0,1 s steps
526 Door Open Limit Supervision 10 300 Door open limit supervision time in 0,1 s steps
527 Door Close Limit Supervision 10 300 Door close limit supervision time in 0,1 s steps
528 Door Opening Time 10 300 Door opening time in 0,1 s steps when door open limit not in use
529 Door Open Limit In Use 0 1 Door open limit in use
0 = not in use
1 = in use
530 Door Close Limit In Use 0 1 Door close limit in use
0 = not in use
1 = in use
532 Door Nudging Time (NUD) 1 1200 Nudging time in 0,1 s steps
533 Door Nudging Short Time 1 1200 Shortened Nudging time in 0,1 s steps
534 Door Open Too Long Time 1 3000 Timeout for door open too long fault in 0,1 s steps
536 Door Closed Torque 0 3 Door torque control (close command)
0 = torque released when door closed, default
1 = torque not released when door closed/locked
2 = torque released even door locked
3 = torque released at door close limit
541 Door Contact (Car) Filter Time 0 25 Filtering time for car door contact bouncing in 0,1 s steps
542 Door Open Delay 0 50 Door opening delay at stopping in 0,1 s steps
545 Door Torque Reset Time 1 200 Door torque time when elevator vacant
Defines time to keep close command (torque) ON still after car door
contact closed in 0,1 s steps
546 Door Retiring Ramp Full Voltage 0 200 Retiring ramp magnet control full voltage time
Time Defines time to keep full voltage in RR circuitry when RR energized in 0,1
s steps
0 = Full voltage in use all the time
1 ... 200 = Full voltage time (0,1s ... 20s)
547 Door Close Limit Polarity 0 1 Polarity of door close limit contact while door closed (CDL C)
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
548 Door Open Limit Polarity 0 1 Polarity of door open limit contact while door open (CDL O)
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
4/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
552 Door Contact Bouncing Filter 0 25 Filtering time for swing door contact (H4) bouncing in 0,1 s steps
553 Door Opening Delay with Car 0 40 Delay for car door opening if LOA or retiring ramp is in use by 0,1 s steps
Door Lock (LOA)
554 Door DOE buzzer 0 1 DOE buzzer control, (DOE *I)
0 = buzzer disabled
1 = buzzer enabled
556 Door Full Speed Time Closing 0 100 Door closing time at full speed with timer controlled (inverter) door in 0,1
s steps
0 = Full speed used permanently
1 ... 100 = time for full speed (0,1s ... 10s)
557 Door Full Speed Time Opening 0 100 Door opening time at full speed with timer controlled (inverter) door in
0,1 s steps
0 = Full speed used permanently
1 ... 100 = time for full speed (0,1s ... 10s)
559 Door Retiring Ramp Control at 0 1 Defines retiring ramp control for manual landing door at stopping phase
Stop when automatic car door is in use.
0 = retiring ramp de-energizes before car door opening
1 = retiring ramp de-energizes when car door fully opened
560 Door Retiring Ramp Control at 0 1 Defines retiring ramp control for manual landing door at starting phase
Start when automatic car door is in use.
0 = retiring ramp energizes when landing door and car door are closed
1 = retiring ramp energizes when landing door is closed
564 Door Close Button Polarity 0 1 Door Close Button (DCB) polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
565 Door Open Button Polarity 0 1 Door Open Button (DOB) polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
566 Door Photocell Polarity 0 1 Photocell (SRC) polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
567 Door Pressure Limiter Polarity 0 1 Door Pressure Limiter polarity
0 = Normally Open (NO) contact
1 = Normally Closed (NC) contact
568 Door Direction Change Delay 0 100 Interval time between door open and close commandi in 10 ms steps.
569 Car Gate Vacant State 0 1 Automatic car door position when elevator is vacant
0 = door parked open
1 = door closed
571 Door Photocell Supervisions 2 10 Number of stops for photocell uninterrupted monitoring
573 Door Ensured Opening Time 1 40 Ensured door opening time in 0,1 s steps
574 Door Landing Door Lock 5 50 Defines monitoring time for landing door lock contact in 0,1 s steps
Monitoring Time
581 Door Landing Door Type 0 7 Door Type at Landing
0 = automatic landing doors in use
1 = manual door at landing, A side
2 = manual door at landing, B side
3 = manual door at landing, A & B side
4 = manual door at landing, C side
5 = manual door at landing, A & C side
6 = manual door at landing, B & C side
7 = manual door at landing, A & B & C side
699 Door Motion Profile 20 200 Door motion profile adjustment in percentage (%).
This affects to normal opening speed, closing speed and acceleration
profile of serial interface door.
740 Timezone Offset 0 72000 Current timezone offset
5/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
NOTE: Lock type selection needs to be done only when using LOC/LOL
inputs.
1008 Locking Input Type 0 3 Type of locking inputs
0 = Soft lock for car and landing calls
1 = Hard lock for car and landing calls
2 = Hard lock for car calls and soft lock for landing calls
3 = Hard lock for landing calls and soft lock for car calls
Soft lock does NOT cancel registered call when lock activates.
Hard lock DOES cancel registered call when lock activates.
1010 DOB Operation at Car Call 0 2 Door open button (DOB) operation at floor with car call locks
Locked Floor 0 = DOB enabled
1 = DOB enabled when door opened once
2 = DOB disabled when door is closed
1011 Locked Floor Door Closed Torque 0 3 Locked floor door closed torque control
Control 0 = torque releasing allowed
1 = torque releasing not allowed when when car call locked
2 = torque releasing not allowed when when landing call locked
3 = torque releasing not allowed when when car or landing call locked
1013 DOB Operation at Landing Call 0 2 Door open button (DOB) operation at floor with landing call locks
Locked Floor 0 = DOB enabled
1 = DOB enabled when door opened once
2 = DOB disabled when door is closed
1014 Landing Call Lock Indication Type 0 1 Landing call locking indication type at display
0 = lock icon is shown always when floor is locked
1 = lock icon is shown only when call is pressed at locked floor
1017 Landing Lock Operation Group 0 3 Landing call lock operation when group elevator operates as single lift.
Disconnected 0 = Follow IO, Landing call lock status follows locking I/O
1 = Last known, Last known landing call lock status copied from group
2 = All open, All landing call locks are set unlocked
3 = All locked, All landing call locks are set locked
1070 Gong Volume 0 10 Landing/car gong volume at floors other than main floor
0 = off
1 ... 10 = volume level
1071 Gong Volume Main 0 10 Landing/car gong volume at main floor
0 = off
1 ... 10 = volume level
1073 Out of Service Return Floor 0 252 Out of service (OSS) return floor.
(OSS) In use when OSS switch connected to OPT or PIO board.
6/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
1081 Landing Call Light Cancel Point 0 2 Landing call registering light cancel point
0 = when elevator has stopped at destination floor or door starts to open
1 = when elevator starts to decelerate to destination floor
2 = when elevator has stopped to destination floor and doors are fully
opened or retiring ramp has released
1102 Automatic Fault Recovery Time 0 300 Timeout for automatic fault recovering in seconds
1103 Battery Supervision Disabled 0 22 Car roof battery supervision disabled time in hours (h).
Time Car roof battery supervision will be disabled for the time given by this
parameter.
1107 Fault Call Cancel Delay 0 240 Delay in seconds to cancel existing calls in system when fault happens.
1109 Buzzer Volume 0 10 Buzzer volume at floors other than main floor
0 = off
1 ... 10 = volume level
1110 Buzzer Volume Main 0 10 Buzzer volume at main floor
0 = off
1 ... 10 = volume level
7/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
8/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
9/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
10/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
1203 Start Supervision Timeout 1 120 Start supervision timeout in 0,1 s steps.
1205 Stop Delay 0 100 Stop delay in 0,1 s steps between two consecutive starts.
1206 Stop Delay for Relevelling 0 100 Stop delay for relevelling in 0,1 s steps
1207 Final Stopping Point 0 126 Final stopping point
Distance in 1 mm steps from accurate floor level, normal run
1209 V3F Stop Delay Normal Drive 10 200 Time interval in 10 ms steps from speed level signal to stop signal at
stopping phase.
1210 V3F Stop Delay At Inspection 10 200 Time interval in 10 ms steps from speed signal to stop signal at stopping
Drive phase.
1211 V3F Stop Delay for Releveling 10 200 Time interval in 10 ms steps from speed signal to stop signal at stopping
phase.
1212 V3F Stop Delay for EBD Drive 10 200 Time interval in 10 ms steps from speed signal to stop signal at stopping
phase.
1216 Maximum Drive Time for 10 200 Maximum drive time in 0,1 s steps for releveling.
1217 Final Releveling Stopping Point 0 126 Defines distance in 1 mm steps from accurate floor level.
1221 Short Floor Length 200 3000 Maximum length for short floor in millimeters
1231 Star Time for Hydro 0 20 Star time in 0,1 s steps for DOL or Star/Delta pump start sequence with a
hydraulic elevator.
0 = Direct (DOL) start
1 ... 20 = Star ON time before Delta
1232 Pump Off Delay for Hydro 0 50 Delay in 0,1 s steps to keep pump on after up valve is switched off
1234 Delay After Delta 1 50 Delay in 0,1 s steps between delta on and control signals.
1235 Final Stopping Point Up for 0 126 Final stopping point for up direction, hydraulic elevator
Hydro Distance in 1 mm steps from accurate floor level
1236 Final Stopping Point Down for 0 126 Final stopping point for down direction, hydraulic elevator
Hydro Distance in 1 mm steps from accurate floor level
11/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
12/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
1386 EAQ Primary Wave Timer, EN81 1 300 Return floor for Emergency Power Drive (EPD).
77 0 = return drive to nearest floor
1...250 = return floor number
1387 EAQ Seismic Detection Test 2 1440 Door opening side at Emergency Power Drive (EPD) return floor
Time, EN81 77 0 = doors closed
1 = A side door open
2 = B side door open
3 = A & B side doors open
4 = C side door open
5 = A & C side doors open
6 = B & C side doors open
7 = A & B & C side doors open
1389 Hydro Oil Temperature Recovery 0 600 Car light and car fan operation after EPD return drive.
Time 0 = OFF immediately
1 = OFF after timeout defined by parameter
1391 EPD Return Floor 0 250 Car light control during service drive modes
0 = car light permanently OFF
1 = car light permanently ON
2 = car light OFF after car light delay when elevator is stopped
13/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
1406 FID Return Floor Alternative 0 250 Door opening side at floor for machine room fire detection (FID M)
0 = doors closed, at TTC floor all door opens and stay closed
1 = A side door parked open
2 = B side door parked open
3 = A & B side doors parked open
4 = C side door parked open
5 = A & C side doors parked open
6 = B & C side doors parked open
7 = A & B & C side doors parked open
8 = At TTC floor A-side door opens and stays closed
9 = At TTC floor B-side door opens and stays closed
10 = At TTC floor C-side door opens and stays closed
1408 FID Door Open Side Main 0 10 Car light and car fan operation after fire detection return drive.
0 = OFF immediately
1 = OFF after timeout defined by parameter
1409 FID Door Open Side Alternative 0 10 Fire service access floor level for firefighters to gain access to the
fireman's lift.
1 ... 250 = Fireman's return floor number
14/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
Index1 (ATS)
Index2 (PRC)
1436 FRD Return Floor Side 1 7 0 = not allowed
Alternative 1 = down
2 = up
3 = down & up
1437 FRD Return Floor Door 0 1 AES door open time in seconds at main floor
1444 FRD Override Mode Timeout 0 180 AES door open time in seconds at other floors
1451 AES Stop Floors 0 3 0 = car and landing calls disabled
1 = car calls enabled and landing calls disabled
2 = car calls disabled and landing calls enabled
3 = car and landing calls enabled
1452 AES Door Time at Main Floor 10 240 0 = Main floor
1 = Floor where lift stops after serving existing calls
2 = Main floor with AES stop floors served
3 = Floor where lift stops after serving existing calls with AES stop floors
served
1453 AES Door Time at Other Floors 10 240 0 = Normal car call button lights
1 = Illuminate all car call button lights
2 = Illuminate car call button lights as per AES stop floors
1454 AES Calls 0 3 0 = No AES display
1 = AES display in car
2 = AES display at landing
3 = AES display in car and at landing
1455 AES Floor 0 3 0 = disabled
1 = enabled
1456 AES Car Call Lights 0 2 0 = not in use
1 = in use and elevator will be in normal mode
2 = in use and elevator goes to standby mode with doors closed
3 = in use and elevator goes to standby mode with doors open
1457 AES Display 0 3 0 = Out of Service Indication
1 = AES indication
1458 AES Buzzer 0 1 Car call lock from group/E-link operation when group disconnects.
0 = Last received car call lock status
1 = All open, All car call locks are set unlocked
1460 AES Clock Switch 0 3 Automatic Dispatch Floor (ADF)
1 ... 250 = floor number for automatic dispatch
15/18
1374567D03 KCECPU parameter list, KMI, KCEPU ARM9 SW release version 13.2.0.10
1481 ADF Dispatch Floor 1 250 Car roof emergency battery stress test interval time in hours (h).
1482 ADF Destination Floor 0 250 Car roof emergency battery stress test fault type
0 = warning, elevator stays in service
1 = fatal, elevator stays out of service
1483 Lantern Control at Terminal 0 3 Defines duration time in minutes for emergency battery stress test.
Floors
1490 Battery Stress Test Interval Time 72 8760 Defines voltage level for emergency battery stress test.
Value is voltage x 10.
1491 Battery Stress Test Fault Type 0 1 Car roof emergency battery stress test fault type
0 = warning, elevator stays in service
1 = fatal, elevator stays out of service
1492 Battery Stress Test Duration 1 600 Defines duration time in minutes for emergency battery stress test.
1493 Battery Stress Test Fault Level 105 125 Defines voltage level for emergency battery stress test.
Value is voltage x 10.
16/18
Menu 2 Function Description
13 Encoder polarity Motor Encoder Polarity parameter possible values are,
0 = None No encoder available
-1/1 = Shaft motor encoder is mounted directly to motor shaft.
-2/2 = Friction motor encoder is mounted with friction pulley.
14 Motor phase polarity Motor Phase Polarity parameter possible values are,
-1 = U-W-V
1 = U-V-W
17 LWD type LWD Type parameter possible values are,
-1 = clear LWD setup
0 = fixed 50% load
1 = current loop connected to Drive CPU
2 = strain gauge connected to Drive CPU
3 = current loop connected to CCG-1
4 = current loop connected to CCG-2
Menu 3 Function Description
Floor marking setup Used to change the floor markings.
Menu 4 Function Description
1 Elevator mode nor=Normal, InSP=Inspection, Frd=Fireman’s Drive, EPd=Emergency
Power Drive, OSS-C=Out of Service-Car, OSS-L=Out of Service-Landing,
OSS-O=Out of Service-OPT, GAtE=Gateway Mode, PIt=Pit Inspection,
SAFE=Well Access Protection, FId=Fire Detection, rdF=Recall Drive,
SEtUP=Setup, CLS=Car Light Failed, PEn=Pendant, PrC=Priority Call,
noSEt=No setup, IdLE=Idle, Ert=Machine/Engine Room Temperarure,
EAq=Earthquake, Ebd=Emergency Battery Drive, FrE=Fast Recall,
USC=Water Sensor Contact, USC-A=Water Sensor Contact-Marine,
Ats=Attendance Service, AES=Automatic Elevator Service,
hOuSE=Penthouse Visitor Service, PrL=Priority at Landing Low,
PrH=Priority at Landing High, HEL=Hospital Emergency Service
17/18
22 Brake 2 Test Safety inspection test for brake. Open brake 2 to test brake 1.
23 DSP break permit test Safety inspection test for DSP break permission
24 Emergency stop test Safety inspection test for traction with 125% load.
25 Full speed brake 1 test Safety inspection full speed brake 1 test
26 Full speed brake 2 test Safety inspection full speed brake 2 test