PEDESTAL P1 & P4.
CONCRETE CHECK FOR ANCHOR BOLT CAPACITY (DUCTILE)
1. CHECK FOR REINFORCEMENT FOR CONCRETE BREAKOUT
Grade of Bolt : MPa A105
Grade of Reinforcement Steel : MPa 500
Bolt Dia : mm 42
Effective cross-sectional area of anchor; mm2 950
Ase
Nominal tensile strength of Anchor N/mm2 860
futa shall be <1.9 fya or 860 Mpa
Nominal strength of anchor in tension kN 817.0
Nsa = Ase ´ futa
Strength of anchor in tension kN 612.8
fNsa = 0.75*Ase*futa
Allowable Bolt Tensile Capacity (LRFD) kN 367.65 Option-1: Pedestal Rebars
Ast, required based on Anchor Bolt Capacity
(Ductile) : mm2 980.40
Type of additional reinforcement U-Bars
Clear Cover to reinforcement : mm 50
Distance of bolt edge from reinf edge X : mm Wh/2
mm 75
Diameter of Reinforcement Provided, d : mm 20
No of Contributory Reinf bars : 4
Ast,provided : mm2 1256.64
Ldh mm 622
Height required to the bottom of additional mm 1294
bar
Pedestal height provided mm 1775
Foundation mat thickness provided mm 1400
Check for pedestal height provided mm 3060.000
mm Safe
Embedment Depth required : mm 736.00
Total Length of Anchor Bolt (Type-A) mm 945.00
Projection of Anchor Bolt mm 240
Anchor Plate thickness, T mm 30.00
Length after bottom plate, U mm 95.00
Embedment Depth provided : hef mm 850.00
Safe
2. CHECK FOR PULLOUT
Grade of concrete, fc' MPa 32.00
Anchor Bearig Area, Abrg (bottom plate) mm2 22500 150mm x 150mm Option-2: Hairpin / U-Bars
Strength reduction factor, f 0.7 Table 17.5.3 of ACI 318-19
Pullout strength Np = f8.Abrg.fc' kN 504.00
Safe
3. SIDE FACE BLOWOUT
Edge distance to conc, Cx1 mm 300
Edge distance to conc, Cx2 mm 300
Edge distance to conc, Cy1 mm 300
Edge distance to conc, Cy2 mm 300
Spacing of Bolt in X-dir, Sx1 mm 300
Spacing of Bolt in X-dir, Sy1 mm 300
Embedment Depth of anchor bolt, hef mm 850.00
Square anchor plate size mm 150
Net bearing area of the head of anchor;, Abrg mm2 21380
Nsb = 13ca1Abrg1/2lf'c1/2 (Equation 17.6.4.1)
Nsbg = (1 + s/6ca1)Nsb (Equation 17.6.4.2)
Ca1 mm 300.00
Ca2 mm 300.00
Ca2 / Ca1 1.00 Φ= 0
Factor 0.50
Nsb kN 1612.92 Ca1 < 0.4 hef (Section 17.6.4.1)
Nsbg kN 1881.74 Ca1 < 0.4 hef & s < 6ca1 (Section 17.6.4.2)
Concrete sideface blowout strength in tension ΦN kN 1411.307
4. TIES CAPACITY CHECK FOR SHEAR BREAKOUT (DUCTILE)
Allowable Bolt Shear Capacity (LRFD) kN 245.10
Nos of total anchor bolts (bolts at the edge) Nos 2.00
Brakout capacity required kN 490.20
Number of Tie layers in AB region Nos 3
Number of legs per layer Nos 6
Diameter of Reinforcement Provided : mm 12
Total number of legs for Shear Nos 18.00
Strength reduction factor for tension, f 0.675 Check
Shear Capacity of Ties kN 687.07 (Anchor bolt shear shall be transferred through tension in Ties)
Safe
5. CONCRETE PRYOUT CHECK
Nominal Pryout strength, Vcp kN Kcp.Ncp Eqn. 17.7.3.1a of ACI 318-19
Ncp = Ncb = Nominal concrete breakout strength As supplementary rebars are already provided for breakout strength
this check is not applicable
PEDESTAL P2. CONCRETE CHECK FOR ANCHOR BOLT CAPACITY (DUCTILE)
1. CHECK FOR REINFORCEMENT FOR CONCRETE BREAKOUT
Grade of Bolt : MPa A105
Grade of Reinforcement Steel : MPa 500
Bolt Dia : mm 42
Effective cross-sectional area of anchor; mm2 950
Ase
Nominal tensile strength of Anchor N/mm2 860
futa shall be <1.9 fya or 860 Mpa
Nominal strength of anchor in tension kN 817.0
Nsa = Ase ´ futa
Strength of anchor in tension kN 612.8
fNsa = 0.75*Ase*futa
Allowable Bolt Tensile Capacity (LRFD) kN 367.65 Option-1: Pedestal Rebars
Ast, required based on Anchor Bolt Capacity
(Ductile) : mm2 980.40
Type of additional reinforcement U-Bars
Clear Cover to reinforcement : mm 50
Distance of bolt edge from reinf edge X : mm Wh/2
mm 75
Diameter of Reinforcement Provided, d : mm 20
No of Contributory Reinf bars : 4
Ast,provided : mm2 1256.64
Ldh mm 622
Height required to the bottom of additional mm 1294
bar
Pedestal height provided mm 1775
Foundation mat thickness provided mm 1400
Check for pedestal height provided mm 3060.000
mm Safe
Embedment Depth required : mm 736.00
Total Length of Anchor Bolt (Type-A) mm 945.00
Projection of Anchor Bolt mm 240
Anchor Plate thickness, T mm 30.00
Length after bottom plate, U mm 95.00
Embedment Depth provided : hef mm 850.00
Safe
2. CHECK FOR PULLOUT
Grade of concrete, fc' MPa 32.00
Anchor Bearig Area, Abrg (bottom plate) mm2 22500 150mm x 150mm Option-2: Hairpin / U-Bars
Strength reduction factor, f 0.7 Table 17.5.3 of ACI 318-19
Pullout strength Np = f8.Abrg.fc' kN 504.00
Safe
3. SIDE FACE BLOWOUT
Edge distance to conc, Cx1 mm 325
Edge distance to conc, Cx2 mm 325
Edge distance to conc, Cy1 mm 325
Edge distance to conc, Cy2 mm 325
Spacing of Bolt in X-dir, Sx1 mm 350
Spacing of Bolt in X-dir, Sy1 mm 350
Embedment Depth of anchor bolt, hef mm 850.00
Square anchor plate size mm 150
Net bearing area of the head of anchor;, Abrg mm2 21380
Nsb = 13ca1Abrg1/2lf'c1/2 (Equation 17.6.4.1)
Nsbg = (1 + s/6ca1)Nsb (Equation 17.6.4.2)
Ca1 mm 325.00
Ca2 mm 325.00
Ca2 / Ca1 1.00 Φ= 0
Factor 0.50
Nsb kN 1747.33 Ca1 < 0.4 hef (Section 17.6.4.1)
Nsbg kN 2060.96 Ca1 < 0.4 hef & s < 6ca1 (Section 17.6.4.2)
Concrete sideface blowout strength in tension ΦN kN 1545.7172
4. TIES CAPACITY CHECK FOR SHEAR BREAKOUT (DUCTILE)
Allowable Bolt Shear Capacity (LRFD) kN 245.10
Nos of total anchor bolts (bolts at the edge) Nos 2.00
Brakout capacity required kN 490.20
Number of Tie layers in AB region Nos 3
Number of legs per layer Nos 7
Diameter of Reinforcement Provided : mm 12
Total number of legs for Shear Nos 21.00
Strength reduction factor for tension, f 0.675 Check
Shear Capacity of Ties kN 801.58 (Anchor bolt shear shall be transferred through tension in Ties)
Safe
5. CONCRETE PRYOUT CHECK
Nominal Pryout strength, Vcp kN Kcp.Ncp Eqn. 17.7.3.1a of ACI 318-19
Ncp = Ncb = Nominal concrete breakout strength As supplementary rebars are already provided for breakout strength
this check is not applicable
PEDESTAL P2. CONCRETE CHECK FOR ANCHOR BOLT CAPACITY (DUCTILE)
1. CHECK FOR REINFORCEMENT FOR CONCRETE BREAKOUT
Grade of Bolt : MPa A36
Grade of Reinforcement Steel : MPa 500
Bolt Dia : mm 36
Effective cross-sectional area of anchor; mm2 672
Ase
Nominal tensile strength of Anchor N/mm2 860
futa shall be <1.9 fya or 860 Mpa
Nominal strength of anchor in tension kN 577.9
Nsa = Ase ´ futa
Strength of anchor in tension kN 433.4
fNsa = 0.75*Ase*futa
Allowable Bolt Tensile Capacity (LRFD) kN 120.96 Option-1: Pedestal Rebars
Ast, required based on Anchor Bolt Capacity
(Ductile) : mm2 322.56
Type of additional reinforcement U-Bars
Clear Cover to reinforcement : mm 50
Distance of bolt edge from reinf edge X : mm Wh/2
mm 63
Diameter of Reinforcement Provided, d : mm 20
No of Contributory Reinf bars : 4
Ast,provided : mm2 1256.64
Ldh mm 622
Height required to the bottom of additional mm 1294
bar
Pedestal height provided mm 1775
Foundation mat thickness provided mm 1400
Check for pedestal height provided mm 3060.000
mm Safe
Embedment Depth required : mm 725.67
Total Length of Anchor Bolt (Type-A) mm 830.00
Projection of Anchor Bolt mm 240
Anchor Plate thickness, T mm 25.00
Length after bottom plate, U mm 80.00
Embedment Depth provided : hef mm 750.00
Safe
2. CHECK FOR PULLOUT
Grade of concrete, fc' MPa 32.00
Anchor Bearig Area, Abrg (bottom plate) mm2 15625 125mm x 125mm Option-2: Hairpin / U-Bars
Strength reduction factor, f 0.7 Table 17.5.3 of ACI 318-19
Pullout strength Np = f8.Abrg.fc' kN 350.00
Safe
3. SIDE FACE BLOWOUT
Edge distance to conc, Cx1 mm 325
Edge distance to conc, Cx2 mm 325
Edge distance to conc, Cy1 mm 325
Edge distance to conc, Cy2 mm 325
Spacing of Bolt in X-dir, Sx1 mm 350
Spacing of Bolt in X-dir, Sy1 mm 350
Embedment Depth of anchor bolt, hef mm 750.00
Square anchor plate size mm 125
Net bearing area of the head of anchor;, Abrg mm2 14808
Nsb = 13ca1Abrg1/2lf'c1/2 (Equation 17.6.4.1)
Nsbg = (1 + s/6ca1)Nsb (Equation 17.6.4.2)
Ca1 mm 325.00
Ca2 mm 325.00
Ca2 / Ca1 1.00 Φ= 0
Factor 0.50
Nsb kN FALSE Ca1 > 0.4 hef => Not Applicable (Section 17.6.4.1)
Nsbg kN N/A Ca1 > 0.4 hef and/or s > 6ca1=> Not Applicable (Section 17.6.4.2)
Concrete sideface blowout strength in tension ΦN kN #VALUE!
4. TIES CAPACITY CHECK FOR SHEAR BREAKOUT (DUCTILE)
Allowable Bolt Shear Capacity (LRFD) kN 80.64
Nos of total anchor bolts (bolts at the edge) Nos 2.00
Brakout capacity required kN 161.28
Number of Tie layers in AB region Nos 3
Number of legs per layer Nos 6
Diameter of Reinforcement Provided : mm 12
Total number of legs for Shear Nos 18.00
Strength reduction factor for tension, f 0.675 Check
Shear Capacity of Ties kN 687.07 (Anchor bolt shear shall be transferred through tension in Ties)
Safe
5. CONCRETE PRYOUT CHECK
Nominal Pryout strength, Vcp kN Kcp.Ncp Eqn. 17.7.3.1a of ACI 318-19
Ncp = Ncb = Nominal concrete breakout strength As supplementary rebars are already provided for breakout strength
this check is not applicable