0% found this document useful (0 votes)
27 views3 pages

Dsei120 12az

The DSEI120-12AZ is a fast recovery epitaxial diode with a maximum reverse voltage of 1200 V and a forward current rating of 109 A. It features low switching losses, soft recovery behavior, and is suitable for various applications including high-frequency switching devices and uninterruptible power supplies. The document includes detailed specifications, ratings, and dimensions for the diode, as well as terms and conditions for usage.

Uploaded by

danielptr221
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
27 views3 pages

Dsei120 12az

The DSEI120-12AZ is a fast recovery epitaxial diode with a maximum reverse voltage of 1200 V and a forward current rating of 109 A. It features low switching losses, soft recovery behavior, and is suitable for various applications including high-frequency switching devices and uninterruptible power supplies. The document includes detailed specifications, ratings, and dimensions for the diode, as well as terms and conditions for usage.

Uploaded by

danielptr221
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd

DSEI120-12AZ

Fast Recovery IFAVM = 109 A


VRRM = 1200 V
Epitaxial Diode (FRED) trr = 40 ns

TO-268 AA
VRSM VRRM Type
V V
1
1200 1200 DSEI 120-12AZ 4
3

Symbol Conditions Maximum Ratings Features

IFRMS 100 A • International standard package


TVJ = TVJM
IFAVM • 109 A JEDEC TO-268AA
TC = 60°C; rectangular, d = 0.5
IFAV 75 A • Planar passivated chips
TC = 95°C; rectangular, d = 0.5
IFRM 1200 A • Very short recovery time
tP < 10 µs; rep. rating, pulse width limited by TVJM
• Extremely low switching losses
IFSM TVJ = 45°C; t = 10 ms (50 Hz), sine 600 A • Low IRM-values
t = 8.3 ms (60 Hz), sine 660 A • Soft recovery behaviour
TVJ = 150°C; t = 10 ms (50 Hz), sine 540 A • Epoxy meets UL 94V-0
t = 8.3 ms (60 Hz), sine 600 A
Applications
I2t TVJ = 45°C; t = 10 ms (50 Hz), sine 1800 A2 s
t = 8.3 ms (60 Hz), sine 1800 A2 s • Antiparallel diode for high frequency
switching devices
TVJ = 150°C; t = 10 ms (50 Hz), sine 1450 A2 s • Anti saturation diode
t = 8.3 ms (60 Hz), sine 1500 A2 s • Snubber diode
TVJ -40...+150 °C • Free wheeling diode in converters
TVJM 150 °C and motor control circuits
Tstg -40...+150 °C • Rectifiers in switch mode power
supplies (SMPS)
Ptot TC = 25°C 357 W
• Inductive heating and melting
Md mounting torque 0.8...1.2 Nm • Uninterruptible power supplies (UPS)
Weight typical 6 g • Ultrasonic cleaners and welders

Symbol Conditions Characteristic Values Advantages


typ. max. • High reliability circuit operation
• Low voltage peaks for reduced
IR VR = VRRM TVJ = 25°C 3 mA
protection circuits
VR = 0.8·VRRM TVJ = 25°C 1.5 mA
• Low noise switching
VR = 0.8·VRRM TVJ = 125°C 20 mA
• Low losses
VF IF = 70 A TVJ = 150°C 1.55 V • Operating at lower temperature or
TVJ = 25°C 1.8 V space saving by reduced cooling
VT0 for power-loss calculations only 1.2 V
rT TVJ = TVJM 4.6 mΩ
RthJC 0.35 K/W
RthCH 0.15 K/W
RthJA 35 K/W
trr IF = 1 A; -di/dt = 200 A/µs; VR = 30 V; TVJ = 25°C 40 60 ns
IRM VR = 350 V; IF = 75 A; -diF/dt = 200 A/µs 25 30 A
L < 0.05 µH; TVJ = 100°C
• Chip capability Data according to IEC 60747

IXYS reserves the right to change limits, test conditions and dimensions. 20160530a

© 2016 IXYS All rights reserved 1-3


DSEI120-12AZ

150 16 120
TVJ = 100°C
TVJ = 100°C VR = 600 V
14
125 VR = 600 V 100
12
IF = 140 A
100 80 70 A
10 35 A
IF Qr IRM
IF = 140 A
75 8 70 A 60
TVJ = 150°C 35 A
[A] [ C] [A]
6
50 40
TVJ = 100°C
4
25 20
2
TVJ = 25°C
0 0 0
0.5 1.0 1.5 2.0 100 1000 0 200 400 600 800 1000

VF [V] -diF /dt [A s] -diF /dt [A s]


Fig. 1 Forward current IF vs. VF Fig. 2 Reverse recovery charge Fig. 3 Peak reverse current
Qr versus -diF /dt IRM versus -diF /dt

1.4 500 60 1.5


TVJ = 100°C TVJ = 100°C
VR = 600 V IF = 100 A
450 50
1.2

400 40 1.0
1.0 tfr VFR
VFR
trr 350
IF = 140 A tfr
Kf 70 A 30
IRM 35 A
[ s]
0.8 [ns] [V]
300 20 0.5
Qr
0.6
250 10

0.4 200 0 0.0


0 40 80 120 160 0 200 400 600 800 1000 0 200 400 600 800 1000
TVJ [°C] -diF /dt [A s] -diF /dt [A s]
Fig. 4 Dynamic parameters Fig. 5 Recovery time Fig. 6 Peak forward voltage
Qr, IRM versus TVJ trr versus -diF /dt VFR and tfr versus -diF /dt

D=0.7

ZthJC 0.5
Constants for ZthJC calculation:
0.3

0.1 0.2

0.01
i Rthi (K/W) ti (s)
[K/W]
0.05
1 0.017 0.00038
2 0.0184 0.0026
Single Pulse
3 0.1296 0.0387
4 0.185 0.274
0.01
0.001 0.01 0.1 1 10
t [s]

Fig. 7 Transient thermal resistance junction to case at various duty cycles


IXYS reserves the right to change limits, test conditions and dimensions. 20160530a

© 2016 IXYS All rights reserved 2-3


DSEI120-12AZ

Dimensions TO-268AA

Millimeter Inches
Dim.
min max min max
A 4.90 5.10 0.193 0.201
A1 2.70 2.90 0.106 0.114
A2 0.02 0.25 0.001 0.010
b 1.15 1.45 0.045 0.057
C 0.40 0.65 0.016 0.026
C2 1.45 1.60 0.057 0.063
D 13.80 14.00 0.543 0.551
D1 11.80 12.10 0.465 0.476
D2 7.50 7.80 0.295 0.307
D3 2.90 3.20 0.114 0.126
E 15.85 16.05 0.624 0.632
E1 13.30 13.60 0.524 0.535
e 5.450 BSC 0.215 BSC
H 18.70 19.10 0.736 0.752
L 1.70 2.00 0.067 0.079
L2 1.00 1.15 0.039 0.045
L3 0.250 BSC 0.010 BSC
L4 3.80 4.10 0.150 0.161

Terms & Conditions of usage


The data contained in this product data sheet is exclusively intended for technically trained staff. The user will have to evaluate the suitability of the product for the intended application and the completeness of the product
data with respect to his application. The specifications of our components may not be considered as an assurance of component characteristics. The information in the valid application- and assembly notes must be consi-
dered. Should you require product information in excess of the data given in this product data sheet or which concerns the specific application of your product, please contact the sales office, which is responsible for you.
Due to technical requirements our product may contain dangerous substances. For information on the types in question please contact the sales office, which is responsible for you.
Should you intend to use the product in aviation, in health or live endangering or life support applications, please notify. For any such application we urgently recommend
- to perform joint risk and quality assessments;
- the conclusion of quality agreements;
- to establish joint measures of an ongoing product survey, and that we may make delivery dependent on the realization of any such measures.

IXYS reserves the right to change limits, test conditions and dimensions. 20160530a

© 2016 IXYS All rights reserved 3-3

You might also like