Sma Scs 3950 Up

The Sunny Central Storage UP series includes battery inverters designed for large-scale storage systems, offering outputs up to 3960 kVA and efficient cooling systems for diverse climatic conditions. These inverters support various applications with customizable monitoring, grid management functions, and high efficiency of up to 98.8%. They are suitable for outdoor use and can be transported in standard shipping containers, making them versatile for different energy management needs.

Uploaded by

Zouhair Hamza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
261 views4 pages

Sma Scs 3950 Up

The Sunny Central Storage UP series includes battery inverters designed for large-scale storage systems, offering outputs up to 3960 kVA and efficient cooling systems for diverse climatic conditions. These inverters support various applications with customizable monitoring, grid management functions, and high efficiency of up to 98.8%. They are suitable for outdoor use and can be transported in standard shipping containers, making them versatile for different energy management needs.

Uploaded by

Zouhair Hamza
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

SUNNY CENTRAL STORAGE UP

SCS 3450 UP / SCS 3600 UP / SCS 3800 UP / SCS 3950 UP

Efficient Robust Flexible Versatile


• Up to 4 inverters can be transported • Intelligent air cooling system • One device for all applications • Integrated battery communication
in one standard shipping container OptiCool for efficient cooling • Stand-alone device or turnkey • Customized monitoring and control
• Higher power density • Suitable for outdoor use in all solution with SMA medium-voltage of inverters
climatic ambient conditions system • Grid management functions for
worldwide dynamic grid support
• Integrated voltage supply for internal
consumption and external loads

SUNNY CENTRAL STORAGE UP


Battery inverter for large-scale storage systems
With an output of up to 3960 kVA and system voltages up to 1500 V DC, the SMA Sunny Central Storage allows for more
efficient and flexible system design for battery power plants. A separate voltage supply and additional space are available
for the installation of customer equipment. The intelligent cooling system OptiCool ensure smooth operation even in extreme
ambient temperature.
SUNNY CENTRAL STORAGE UP

Technical Data SCS 3450 UP SCS 3600 UP

Battery side (DC)


Operating DC voltage range VDC 880 V to 1500 V 921 V to 1500 V
Max. DC current IDC, max 4750 A
Fuse characteristic for battery connection - pre-arcing integral limit single DC busbar /
split DC busbar 12) 14) 10.75 MA²s / 8.0 MA²s
Single DC busbar 36 connections per pole / split DC busbar 12/12/12 connections per ●/○/○
pole / fused single DC busbar 22 connections per pole 15)
DC connection with terminal lug
Grid side (AC)
Nominal AC power at 1200 Vdc and cos φ =1.0 (at 25°C) 3450 kW 3620 kW
AC apparent power at 1200 Vdc (at 25°C / at 40°C / at 50°C)3) 13) 3450 kVA / 3140 kVA / 2930 kVA 3620 kVA / 3290 kVA / 3075 kVA
Max. AC current IAC, max (at 25°C / at 40°C / at 50°C) 3320 A / 3020 A / 2820 A 3320 A / 3020 A / 2820 A
Max. total harmonic distortion < 3% at nominal power
Nominal AC voltage / AC voltage range1) 8) 600 V / 480 V to 720 V 630 V / 504 V to 756 V
AC power frequency / range 50 Hz / 47 Hz to 53 Hz
60 Hz / 57 Hz to 63 Hz
Min. short-circuit ratio at the AC terminals9) >2
Cos Phi at rated power / displacement Cos Phi adjustable8) 10) 1 / 0.0 overexcited to 0.0 underexcited
AC connection with busbar system (three busbars, one per line conductor)
Efficiency
Max. efficiency2) 98.8%
Protective Devices
Input-side disconnection point DC load break switch
Output-side disconnection point AC circuit breaker
DC overvoltage protection Surge arrester, type I
AC overvoltage protection (optional) Surge arrester, class I
Lightning protection (according to IEC 62305-1) Lightning Protection Level III
Insulation monitoring ●
Degree of protection: electronics / air duct / connection area (as per IEC 60529) IP54 / IP34 / IP34
General Data
Dimensions (W / H / D) 2780 / 2318 / 1588 mm (109.4 / 91.3 / 62.5 inch)
Weight < 3700 kg / < 8200 lb
Self-consumption (max.4) / partial load5) / average6)) < 8100 W / < 1800 W / < 2000 W
Self-consumption (standby) < 370 W
Internal (8.4 kVA transformer) / external auxiliary power supply ●/○
Noise emission7) 65.0 dB(A)
Operating temperature range (optional)8) (−40°C) −25°C to 60°C / (−40°F) −13°F to 140°F
Temperature range (standby) −40°C to 60°C / −40°F to 140°F
Temperature range (storage) −40°C to 70°C / −40°F to 158°F
Max. permissible value for relative humidity (condensing / non-condensing) 95% to 100% (2 month/year) / 0% to 95%
Maximum operating altitude above MSL8) 1000 m / 2000 m11) ●/○
Fresh air consumption 6500 m³/h
Features
Grid forming / black start ready ○/○
Communication Ethernet, Modbus Master, Modbus Slave
Communication with SMA string monitor (transmission medium) Modbus TCP / Ethernet (FO MM, Cat-5)
Enclosure / roof color RAL 9016 / RAL 7004
Supply transformer for external loads ○ (2.5 kVA)
Standards and directives complied with CE, IEC / EN 62109-1 / -2, AR-N 4110 / 4120, Arrêté du 23/04/08
EMC standards IEC 61000-6-2, EN 55011, CISPR11, FCC Part 15 Class A
Quality standards and directives complied with VDI/VDE 2862 page 2, DIN EN ISO 9001

Type designation SCS 3450 UP SCS 3600 UP

● Standard features ○ Optional — Not available


1) At nominal AC voltage, nominal AC power decreases in the same proportion 9) A short-circuit ratio of < 2 requires a special approval from SMA
2) Efficiency measured without internal power supply 10) Max. power values (S/P/Q) can be requested based on project specific design
3) AC apparent power at higher dc voltages on request 11) Earlier temperature-dependent de-rating and reduction of DC open-circuit voltage
4) Self-consumption at rated operation 12) Battery short circuit disconnection has to be done on the battery side with ultra rapid battery
5) Self-consumption at < 75% Pn at 25°C string or group fuses, e.g. fuse type aR/aBat & DC time constant Tau (L/R) <=1ms
6) Self-consumption averaged out from 5% to 100% Pn at 25°C 13) Depending on the ratio of reactive power (cos φ), an extended power derating may occur
7) Sound pressure level at a distance of 10 m 14) Please check the manual for further information
8) Values apply only to inverters. Permissible values for SMA MV solutions from 15) fused DC input equipped with optional 750 A, 900 A or 1250 A fuses
SMA can be found in the corresponding data sheets

Technical Data SCS 3800 UP SCS 3950 UP

Battery side (DC)


Operating DC voltage range VDC 962 V to 1500 V 1003 V to 1500 V
Max. DC current IDC, max 4750 A
Fuse characteristic for battery connection - pre-arcing integral limit single DC busbar /
10.75 MA²s / 8.0 MA²s
split DC busbar 12) 14)
Single DC busbar 36 connections per pole / split DC busbar 12/12/12 connections per
●/○/○
pole / fused single DC busbar 22 connections per pole 15)
DC connection with terminal lug
Grid side (AC)
Nominal AC power at 1200 Vdc and cos φ =1.0 (at 25°C) 3800 kW 3960 kW
AC apparent power at 1200 Vdc (at 25°C / at 40°C / at 50°C)3) 13) 3800 kVA / 3455 kVA / 3230 kVA 3960 kVA / 3610 kVA / 3365 kVA
Max. AC current IAC, max (at 25°C / at 40°C / at 50°C) 3320 A / 3020 A / 2820 A 3320 A / 3020 A / 2820 A
Max. total harmonic distortion < 3% at nominal power
Nominal AC voltage / AC voltage range1) 8) 660 V / 528 V to 759 V 690 V / 552 V to 759 V
AC power frequency / range 50 Hz / 47 Hz to 53 Hz
60 Hz / 57 Hz to 63 Hz
Min. short-circuit ratio at the AC terminals9) >2
Cos Phi at rated power / displacement Cos Phi adjustable8) 10) 1 / 0.0 overexcited to 0.0 underexcited
AC connection with busbar system (three busbars, one per line conductor)
Efficiency
Max. efficiency2) 98.8%
Protective Devices
Input-side disconnection point DC load break switch
Output-side disconnection point AC circuit breaker
DC overvoltage protection Surge arrester, type I
AC overvoltage protection (optional) Surge arrester, class I
Lightning protection (according to IEC 62305-1) Lightning Protection Level III
Insulation monitoring ●
Degree of protection: electronics / air duct / connection area (as per IEC 60529) IP54 / IP34 / IP34
General Data
Dimensions (W / H / D) 2780 / 2318 / 1588 mm (109.4 / 91.3 / 62.5 inch)
Weight < 3700 kg / < 8200 lb
Self-consumption (max.4) / partial load5) / average6)) < 8100 W / < 1800 W / < 2000 W
Self-consumption (standby) < 370 W
Internal (8.4 kVA transformer) / external auxiliary power supply ●/○
Noise emission7) 65.0 dB(A)
Operating temperature range (optional)8) (−40°C) −25°C to 60°C / (−40°F) −13°F to 140°F
Temperature range (standby) −40°C to 60°C / −40°F to 140°F
Temperature range (storage) −40°C to 70°C / −40°F to 158°F
Max. permissible value for relative humidity (condensing / non-condensing) 95% to 100% (2 month/year) / 0% to 95%
Maximum operating altitude above MSL8) 1000 m / 2000 m11) ●/○
Fresh air consumption 6500 m³/h
Features
Grid forming / black start ready ○/○
Communication Ethernet, Modbus Master, Modbus Slave
Communication with SMA string monitor (transmission medium) Modbus TCP / Ethernet (FO MM, Cat-5)
Enclosure / roof color RAL 9016 / RAL 7004
Supply transformer for external loads ○ (2.5 kVA)
Standards and directives complied with CE, IEC / EN 62109-1 / -2, AR-N 4110 / 4120, Arrêté du 23/04/08
EMC standards IEC 61000-6-2, EN 55011, CISPR11, FCC Part 15 Class A
Quality standards and directives complied with VDI/VDE 2862 page 2, DIN EN ISO 9001

Type designation SCS 3800 UP SCS 3950 UP

● Standard features ○ Optional — Not available


SYSTEM DIAGRAM

SCS-UP-DS-en-16 Printed on FSC paper. All products and services described and all technical data are subject to change, even for reasons of country-specific deviations, at any time without notice. SMA assumes no liability for typographical or other errors. For current information, please visit www.SMA-Solar.com.
Grid-connected functions Compatible with energy management system functionalities

• Setpoints for active and reactive power • External static grid supporting functions
• Static grid support Q(U), P(f) • Ramp-rate control of PV power
• Dynamic grid support (FRT) • Peak shaving
• Active islanding detection (AID) • Energy shifting
• High compatibility with different battery types • Genset optimization control
• Reducing necessary spinning reserve of gensets
• Battery start-up and stop sequence
• Operates the battery within optimal operation window
• Grid Forming
• Black Start