Valvula Solenoide VZ5000
Valvula Solenoide VZ5000
Series VZ5000
How to Order VK
r
so
VZ
es
pr
up
es
ag
ize
VF
n
olt
de
io
ts
ry
ev
at
ge
rri
or
nt
tu
rg
pe
n
ve
ta
le
)p
tio
/su
ac
ty
l
lo
vo
ca
(B
op
VFR
ht
of
ad
ua
n
tr i
/2
lig
ed
io
dy
e
re
ec
an
A)
ith
pt
at
p
Bo
Th
Ty
El
4(
M
W
O
R
Thread type
3 Nil Rc
F G
PE port
3(R) port N NPT
T NPTF
3 position exhaust center
4
Rated voltage 4(A), 2(B) port size
1 100 VAC, 50/60 Hz 01 Rc 1 8
2 200 VAC, 50/60 Hz C6 One-touch fitting for ø6
3 position pressure center
3∗ 110 VAC, 50/60 Hz C8 One-touch fitting for ø8
4∗ 220 VAC, 50/60 Hz Note) P, R1, R2 port: Rc 1/8
5 5∗ 24 VDC
6 12 VDC
9∗ Other Manual override
∗ Option
Nil: Non-locking B: Locking type B C: Locking type C
Electrical entry
push type (Slotted) (Manual)
Grommet L plug connector M plug connector DIN terminal
G: Lead wire L: With lead wire M: With MN: Without D: With connector
length (Length 300 mm) lead wire lead wire
300 mm (Length 300 mm)
H: Lead wire LN: Without LO: Without MO: Without DO: Without
length lead wire connector connector connector
600 mm Light/Surge voltage suppressor
Nil None
Z∗ With light/surge voltage suppressor
S With surge voltage suppressor
∗ Type “LN”, “MN”: With 2 sockets. ∗ Not available for “GZ”, “HZ” and “DOZ”
3-3-53
Series VZ5000
Specifications
Applicable for cylinder Fluid Air
actuation (up to ø50). Operating pressure
2 position single 0.15 to 0.7
2 position double 0.1 to 0.7
range (MPa)
Compact size 3 position 0.15 to 0.7
(Width: 18 mm) Ambient and fluid temperature (°C) –10 to 50°C (No freezing. Refer to page 3-13-4.)
Response time (ms) (1) 2 position single, double 20 or less
Low power consumption: (at the pressure of 0.5 MPa) 3 position 50 or less
1.8 W DC Max. operating 2 position single, double 10
frequency (Hz) 3 position 3
Effective area Refer to the table below.
Manual override (2) Non-locking push type, Locking slotted type, Locking lever type
Pilot exhaust method Individual pilot exhaust type, Common exhaust (pilot and main valve) type
Lubrication Not required
Mounting orientation Unrestricted
Impact/Vibration resistance (m/s2 )(3) 300/50
Enclosure Dustproof
Note 1) Based on dynamic performance test, JIS B 8375-1981. (Coil temperature: 20°C, at
rated voltage, without surge suppressor)
Note 2) When operating the locking type manually, apply torque of 0.2 N·m or less.
Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the
axial direction and at the right angles to the main valve and
armature in both energized and de-energized states every once for
each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000
Hz. Test was performed at both energized and de-energized states
in the axial direction and at the right angles to the main valve and
armature. (Values at the initial period)
3-3-54
5 Port Solenoid Valve
Body Ported Series VZ5000
Flow Characteristics/Weight
Port size Flow characteristics Note)
Weight (g)
Valve model Type of actuation 1, 5, 3 4, 2 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv Grommet
2 Single 120
position 2.2 0.36 0.58 2.4 0.34 0.63
Double 160
3 Closed center Rc 1/8 Rc 1/8 1.8 0.37 0.45 2.0 0.35 0.49
VZ520--01 position Exhaust center 1.2 0.50 0.34 3.0[1.3] 0.35[0.52] 0.73[0.39] 160
Pressure center 3.0 [0.83] 0.37[0.50] 0.78[0.25] 1.8 0.37 0.45
2 Single 120
position 1.6 0.33 0.4 2.2 0.32 0.53
Double C6 160 VK
Closed center Rc 1/8 (One-touch 1.4 0.27 0.35 1.9 0.33 0.49
3
VZ520--C6 Exhaust center fitting for ø6) 1.1 0.37 0.27 2.5[1.3] 0.32[0.54] 0.61[0.38] 160
position
Pressure center 1.8 [0.78] 0.36[0.40] 0.45[0.22] 1.6 0.30 0.39
VZ
2 Single 120
position Double C8
2.0 0.39 0.52 2.3 0.34 0.61
160 VF
Closed center Rc 1/8 (One-touch 1.7 0.35 0.42 2.0 0.29 0.49
3
VZ520--C8 position Exhaust center fitting for ø8) 1.2 0.38 0.33 2.6[1.3] 0.35[0.49] 0.67[0.38] 160 VFR
Pressure center 1.9 [0.86] 0.57[0.46] 0.59[0.25] 1.7 0.39 0.42
Note) [ ]: Denotes the normal position. Exhaust center: 4/2 5/3, Pressure center: 1 4/2 VP4
VZS
Use as a guide for selection.
Cylinder Speed Chart Please confirm the actual conditions with SMC Sizing Program. VFS
Bore size
Series CJ2
Average Pressure 0.5 MPa
Series CM2
Pressure 0.5 MPa
Series MB, CA1 Note)
Pressure 0.5 MPa
VS4
Series speed Load factor 50%
Load factor 50% Load factor 50%
(mm/s) Stroke 60 mm
Stroke 300 mm Stroke 500 mm VQ7
ø6 ø10 ø16 ø20 ø25 ø32 ø40 ø40 ø50 ø63 ø80 ø100
800
700 605
749
610
Perpendicular, EVS
600 560 558 upward actuation
500 475 487 Horizontal actuation
VZ5120-01 400 286 310
398 364 360
301
379 386 VFN
300 214 204 235 252 252
200 130 157 103
159
100
0
∗ It is when the cylinder is extending that is meter-out controlled by speed controller which is directly connected with cylinder, and its needle valve
with being fully open.
∗ The average velocity of the cylinder is what the stroke is divided by the total stroke time.
∗ Load factor: ((Load weight x 9.8)/Theoretical force) x 100%
Note) The Series CA1 has been changed to the Series CA2.
Conditions
Body ported Series CJ2 Series CM2 Series MB
Tube bore x Length ø6 x 1 m ø6 x 1 m ø12 x 1 m
VZ5120-01 Speed controller AS2301F-06 AS3301F-06 AS4001F-12
Silencer AN110-01 AN200-02
3-3-55
Series VZ5000
Construction
2 position single 2 position double
De-energized
De-energized
De-energized De-energized
3-3-56
5 Port Solenoid Valve
Body Ported Series VZ5000
2 Position Single
VK
Manual override
(Mounting hole for manifold) (Non-locking)
VZ
G: 300 mm
H: 600 mm
(Mounting hole)
VFR
VP4
VZS
VFS
VS4
(PE port)
VQ7
EVS
VFN
(Piping port)
≅300
(Lead wire length)
≅300
MAX. 10
C6: MAX. 6
2-One-touch fitting
(A, B port)
Applicable tubing model
Applicable cable O.D. C6: T0604
C8: T0806
ø3.5 to ø7
3-3-57
Series VZ5000
2 Position Double
VZ5220
Manual
override
(Mounting hole for manifold) (Non-locking)
(PE port)
(Piping port)
≅300
(Lead wire length)
≅300
C8
C6: MAX. 6
MAX. 10
2-One-touch fitting
(A, B port)
Applicable tubing model
C6: T0604
C8: T0806
3-3-58
5 Port Solenoid Valve
Body Ported Series VZ5000
3 Position Closed Center/Exhaust Center/Pressure Center
VZ5320
VZ5420
VK
VZ
VF
G: 300 mm
H: 600 mm
(Mounting hole)
VP4
VZS
VFS
VS4
VQ7
(PE port)
EVS
VFN
(Piping port)
3 3
VZ5 4 20-L-01 VZ5 4 20-M-01
5 5
≅300
(Lead wire length)
≅300
2-One-touch fitting
Applicable cable O.D. (A, B port)
ø3.5 to ø7 Applicable tubing model
C6: T0604
C8: T0806
3-3-59
Series VZ5000/Body ported
Manifold Specifications
Manifold Standard
Manifold Specifications
Model Type 20 Type 21
Manifold type Single base/B mount
P(SUP)/R(EXH) Common SUP/Common EXH
Valve stations 2 to 15 stations 2 to 20 stations
4(A), 2(B) port location Valve
1(P), 3/5(R) port Rc 1 8 Rc 1 4
Port size
4(A), 2(B) port Rc 1 8 , C6, C8
Flow Characteristics
Port size Flow characteristics
Manifold 1(P), 5/3(R) 2(B), 4(A) 1 4/2 (P A/B) 4/2 5/3 (A/B R)
port port 3
C [dm /(s·bar)] b Cv C [dm3/(s·bar)] b Cv
VV5Z5-20-01 1/8 1/8 2.2 0.35 0.57 2.3 0.26 0.55
VV5Z5-20-C6 1/8 C6 1.4 0.32 0.37 2.0 0.25 0.49
VV5Z5-20-C8 1/8 C8 1.7 0.38 0.45 2.1 0.25 0.51
VZ52
VV5Z5-21-01 1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
VV5Z5-21-C6 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
VV5Z5-21-C8 1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Note) Value at manifold base mounted, 2 position single operating
Rated voltage 100 VAC 50/60 Hz, 110 VAC 50/60 Hz, 24 VDC, 12 VDC
Note) Withstand voltage specification of wiring unit part is equivalent to JIS C 0704 class 1.
Flow Characteristics
Port size Flow characteristics
Manifold 1(P), 5/3(R) 2(B), 4(A) 1 4/2 (P A/B) 4/2 5/3 (A/B R)
port port C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv
VV5Z5-21P-01 1/4 1/8 2.1 0.36 0.55 2.3 0.26 0.54
VV5Z5-21P-C6 VZ523 1/4 C6 1.4 0.32 0.36 2.1 0.24 0.50
VV5Z5-21P-C8 1/4 C8 1.8 0.37 0.50 2.1 0.20 0.50
Note) Value at manifold base mounted, 2 position single operating
3-3-60
5 Port Solenoid Valve
Body Ported Series VZ5000
Common SUP/Common EXH
Type 20 How to Order
4(A), 2(B) port
VV5Z5 20 05 1
Stations P, R port
1(P) port 02 2 stations thread type
···
···
Rc 1/8 Nil Rc
Applicable solenoid
15 15 stations 00F G
3/5(R) port valve
Rc 1/8 00N NPT G 01 VK
00T NPTF VZ52- LM - C6
D C8
Note) For more than 6 stations, supply air to both sides of P port and exhaust air from both sides of R port.
Applicable blanking plate VZ
assembly
Type 21 How to Order
DXT199-22-1A VF
Applicable individual EXH
4(A), 2(B) port
VV5Z5 21 05 1 spacer assembly
DXT199-29-1A VFR
Stations P, R port
1(P) port
02 2 stations thread type VP4
···
···
Nil Rc
Rc 1/4 20 20 stations 00F
00N
G
NPT
VZS
3/5(R) port 00T NPTF
Rc 1/4 VFS
Note) For more than 10 stations, supply air to both sides of P port and exhaust air from
both sides of R port.
VS4
Flat Ribbon Cable Type 21P How to Order Applicable solenoid
valve
1
VQ7
01
VV5Z5 21P 05 VZ523- 35 MOZ-C6
6 C8
EVS
Applicable blanking plate
Stations P, R port assembly
4(A), 2(B) port 03 3 stations thread type DXT199-22-3A VFN
···
···
3-3-61
Series VZ5000
Option
Combinations of Solenoid Individual EXH Spacer Assembly Installation of the VZ500 Valve
Valve, Manifold Gasket and DXT199-29-1A on the VZ5000 Manifold
Manifold Base • Use of an adaptor plate makes it possible
to mount Series VZ500 on the manifold
Round head base of Series VZ5000.
Round head combination screw combination screw • The mounting direction is shown in the
diagram below. Mount the solenoid so that
(With springM3washer
x 31
) (M3
With spring washer)
x 47
it will be on the same side as the single
solenoid of the Series VZ5000.
Gasket (M3
With spring washer )
x 31
Individual
EXH spacer
Gasket
Round head
combination screw
Applicable base
VV5Z5-20
VV5Z5-21 (With springM3washer
x 10
)
Note) Please contact SMC when using an Adapter plate
individual EXH spacer assembly,
an individual or an adapter plate
assembly on VV5Z5-21P.
O-ring
(M3 (M3
With spring washer )
x8
With spring washer )
x8
Gasket
Dust cap
Caution
Applicable base Mounting Screw Tightening Torques
VV5Z5-21P M3: 0.8 N·m
3-3-62
5 Port Solenoid Valve
Body Ported Series VZ5000
Type 20 Manifold
VV5Z5-20- Station 1
2n-Rc 1/8
(4(A), 2(B) port)
Grommet (G), (H)
(Pitch)
4-ø4.5
(Mounting hole)
VK
VZ
VF
Manual override
VZS
G: 300 mm
(Non-locking) H: 600 mm
VFS
(Lead wire length)
VS4
VQ7
EVS
VFN
(mm)
Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15
L1 59 78 97 116 135 154 173 192 211 230 249 268 287 306
L2 47 66 85 104 123 142 161 180 199 218 237 256 275 294
L plug connector (L) M plug connector (M) DIN terminal (D) Built-in One-touch fittings
MAX. 10
(Lead wire length)
C6: MAX. 6
≅300
2n-One-touch fitting
(4(A), 2(B) port)
Applicable tubing model
C6: T0604
C8: T0806
3-3-63
Series VZ5000
Type 21 Manifold
VV5Z5-21- Station 1
2n-Rc 1/8
Grommet (G), (H) (4(A), 2(B) port)
(Pitch)
(Mounting hole)
6-Rc 1/4
(1(P), 3/5(R) port)
PE port
(mm)
Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388
L plug connector (L) M plug connector (M) DIN terminal (D) Built-in One-touch fittings
MAX. 10
(Lead wire length)
≅300
C6: MAX. 6
≅300 C8: MAX. 6.5
(Lead wire length)
Applicable cable O.D.
ø3.5 to ø7
2n-One-touch fitting
(4(A), 2(B) port)
Applicable tubing model
C6: T0604
C8: T0806
3-3-64
5 Port Solenoid Valve
Body Ported Series VZ5000
Type 21P Manifold
VV5Z5-21P- Station
VV5Z5-21P- Station
VK
Manual override VZ
(Non-locking)
2n-Rc 1/8
(4(A), 2(B) port)
VF
(Pitch) VFR
(Mounting hole)
6-Rc 1/4
VP4
(1(P), 3/5(R) port)
VZS
VFS
VS4
VQ7
(Station n)···························(Station 1)
C6: MAX. 6
C8: MAX. 6.5
2n-One-touch fitting
(4(A), 2(B) port)
Applicable tubing model
C6: T0604
C8: T0806
3-3-65
For details about certified products
conforming to international standards,
visit us at [Link].
Series VZ5000
How to Order VK
or
VZ
ss
re
pp
su
n
e
VF
e
io
ag
d
ry
at
ge
rri
lt
nt
vo
tu
ve
lta
le
tio
ac
ge
lo
vo
e
ca
op
ur
iz
of
ua
VFR
tri
/S
ed
s
dy
e
ec
an
of without indicator light.
ht
rt
p
at
Bo
Po
Lig
Ty
El
M
R
Note)
VZ5 1 4 3 5 F Z
pe
Plug-in VP4
ty
d
a
re
Th
VZS
Non plug-in VZ5 1 4 0 5 L
VFS
Type of actuation Thread type
2 position single solenoid Nil Rc VS4
F G
1 N NPT VQ7
T NPTF
Port size
Body option
0: Individual exhaust Nil: Without 01: Rc 1 8
EVS
2 position double solenoid for the pilot valve sub-plate With sub-plate Note)
VFN
2
5∗
0 0
24 VDC
5 6 12 VDC
9∗ Other
∗ Option Manual override/Non plug-in type
Electrical entry Nil: Non-locking B: Locking type B C: Locking type C
Grommet L plug connector M plug connector DIN terminal push type (Slotted) (Manual)
G: Lead wire L: With lead wire M: With MN: Without D: With connector
length (Length 300 mm) lead wire lead wire
300 mm (Length 300 mm)
H: Lead wire LN: Without LO: Without MO: Without DO: Without
length lead wire connector connector connector
600 mm
Light/Surge voltage suppressor
Nil None
Z∗ With light/surge voltage suppressor
S With surge voltage suppressor
∗ Type “LN”, “MN”: With 2 sockets. ∗ Not available for “GZ”, “HZ” and “DOZ”
3-3-67
Series VZ5000
Specifications
Applicable for cylinder Fluid Air
2 position single 0.15 to 0.7
actuation (up to ø50). Operating pressure
2 position double 0.1 to 0.7
range (MPa)
Compact size 3 position 0.15 to 0.7
Ambient and fluid temperature (°C) –10 to 50°C (No freezing. Refer to page 3-13-4.)
(Width: 18 mm) Response time (ms)(1) 2 position single, double 20 or less
Low power consumption: (at the pressure of 0.5 MPa) 3 position 50 or less
Max. operating 2 position single, double 10
1.8 W DC frequency (Hz) 3 position 3
Effective area Refer to the table below.
Non-locking push type, Locking slotted type,
Manual override (2) Locking lever type
Individual pilot exhaust, Common exhaust (pilot and main valve)
Pilot exhaust
Common exhaust port for the pilot and main valve
Lubrication Not required
Mounting orientation Unrestricted
Impact /Vibration resistance (m/s2 )(3) 300/50
Enclosure Dustproof
Note 1) Based on dynamic performance test, JIS B 8374-1981. (Coil temperature: 20°C, at
rated voltage, without surge suppressor)
Note 2) When operating the locking type manually, apply torque of 0.2 N·m or less.
Note 3) Impact resistance: No malfunction occurred when it is tested with a drop tester in the
axial direction and at the right angles to the main valve and
armature in both energized and de-energized states every once for
each condition. (Values at the initial period)
Vibration resistance: No malfunction occurred in a one-sweep test between 45 and 2000
Hz. Test was performed at both energized and de-energized states
in the axial direction and at the right angles to the main valve and
armature. (Values at the initial period)
Solenoid Specifications
Grommet (G)/(H), L plug connector (L),
Electrical entry
M plug connector (M), DIN terminal (D)
AC 50/60 Hz 100, 200, 24∗, 48∗, 110∗, 220∗
Coil rated voltage (V)
DC 24, 6∗, 12∗, 48∗
Allowable voltage fluctuation (%) –15 to +10% of rated voltage
Power consumption (W) (1) 1.8 (With indicator light 2.1)
[Current mA] DC
[24 VDC: 75 (With indicator light 87.5)]
3-3-68
5 Port Solenoid Valve
Base Mounted Series VZ5000
Flow Characteristics/Weight
Port size Flow characteristics (1)
Weight (g) (2)
Valve model Type of actuation 1, 5, 3 4, 2 1 4/2 (P A/B) 4/2 5/3 (A/B EA/EB)
(P, EA, EB) (A, B) C [dm3/(s·bar)] b Cv C [dm3/(s·bar)] b Cv Grommet
2 Single 200(120)
2.3 0.45 0.57 2.8 0.37 0.71
position Double 240(160)
VZ540--01 Closed center Rc 1/8 Rc 1/8 1.9 0.36 0.48 2.1 0.46 0.57
3
Exhaust center 1.2 0.48 0.35 3.4[1.3] 0.36[0.57] 0.86[0.41] 240(160)
position
Pressure center 3.3[0.85] 0.43[0.54] 0.78[0.25] 2.1 0.45 0.56
2 Single 200(120)
2.3 0.41 0.61 2.9 0.35 0.74
position Double 240(160) VK
VZ540--02 Closed center Rc 1/4 Rc 1/4 1.9 0.46 0.50 2.2 0.44 0.60
3
position Exhaust center 1.3 0.45 0.35 3.7[1.4] 0.27[0.56] 0.87[0.43] 240(160)
Pressure center 3.6[0.83] 0.23[0.55] 0.84[0.25] 2.1 0.47 0.58
VZ
Note 1) [ ]: Denotes the normal position. Exhaust center: 4/2 5/3, Pressure center: 1 4/2
Note 2) ( ): Without sub-plate. VF
VFR
Use as a guide for selection.
Cylinder Speed Chart Please confirm the actual conditions with SMC Sizing Program.
VP4
Bore size
Series CA1 Note) The CA1 series has been changed to the CA2 series.
VZS
Average
Series speed Pressure 0.5 MPa
(mm/s) Load factor 50% VFS
Stroke 500 mm
ø40 ø50 ø63 ø80 ø100 VS4
800 Perpendicular,
700 upward actuation
600 Horizontal actuation
VQ7
VZ514--02 500
(Piping: ø6 x 1 m) 400 EVS
300
200 VFN
100
800
Perpendicular,
700 upward actuation
600 Horizontal actuation
500
VZ514--02
400
(Piping: ø8 x 1 m)
300
200
100
800
Perpendicular,
700 upward actuation
600 Horizontal actuation
500
VZ514--02
400
(Piping: ø10 x 1 m)
300
200
100
800
Perpendicular,
700 upward actuation
600 Horizontal actuation
500
VZ514--02
400
(Piping: ø12 x 1 m)
300
200
100
3-3-69
Series VZ5000
Construction
2 position single 2 position double
3-3-70
5 Port Solenoid Valve
Base Mounted Series VZ5000
2 Position Single
VZ5140
VK
Manual override (Mounting hole)
(Non-locking) VZ
VF
VFR
VP4
(Lead wire length)
VZS
G: 300 mm
H: 600 mm
3-3-71
Series VZ5000
2 Position Double
VZ5240
Manual override
(Non-locking) (Mounting hole)
(Lead wire length)
G: 300 mm
H: 600 mm
(PE port)
≅300
≅300
3-3-72
5 Port Solenoid Valve
Base Mounted Series VZ5000
3 Position Closed Center/Exhaust Center/Pressure Center
VZ5340
VZ5440
VK
VZ
Manual override (Mounting hole)
(Non-locking)
VF
VZ5540 VFR
VP4
VZS
VFS
VS4
VQ7
(PE port)
EVS
2-Rc 1/4
3-Rc 1/8, 1/4
(3(R1), 5(R2) port)
(1(P), 4(A), 2(B) port) VFN
L plug connector (L) M plug connector (M)
3 3
VZ5 4 40-L- 01
02 VZ5 4 40-M-01
02
5 5
(Lead wire length)
≅300
≅300
3-3-73
Series VZ5000/Base Mounted
Manifold Specifications
Manifold Standard
Manifold Specifications
Model Type 40 Type 41 Type 42
Manifold type Single base/B mount
P(SUP), R(EXH) Common SUP and EXH
Valve stations 2 to 20
4(A), 2(B) port Position Base Base
porting specifications Direction Bottom Side
1(P), 3/5(R) port Rc 1/4
01(Rc 1/8)
C6 (One-touch fitting for ø6)
Port size
4(A), 2(B) port Rc 1/8 C8 (One-touch fitting for ø8)
B7 (One-touch fitting for 1/4")
C9 (One-touch fitting for 5/16")
Flow Characteristics
Port size Flow characteristics
Manifold 1(P), 5/3(R) 2(B), 4(A) 1 4/2 (P A/B) 4/2 5/3 (A/B R)
port port 3
C [dm /(s·bar)] b Cv C [dm3/(s·bar)] b Cv
VV5Z5-40 1/4 1/8 2.1 0.28 0.51 2.5 0.23 0.59
VV5Z5-41 1/4 1/8 2.0 0.30 0.50 2.2 0.30 0.55
VZ54
VV5Z5-42-C6 1/4 C6 1.5 0.32 0.38 2.2 0.23 0.52
VV5Z5-42-C8 1/4 C8 1.9 0.24 0.46 2.2 0.26 0.53
Note) Value at manifold base mounted, 2 position single operating
Flow Characteristics
Port size Flow characteristics
Manifold 1(P), 5/3(R) 2(B), 4(A) 1 4/2 (P A/B) 4/2 5/3 (A/B R)
port port 3
C [dm /(s·bar)] b Cv C [dm3/(s·bar)] b Cv
VV5Z5-45 C10 C6 1.5 0.31 0.38 2.2 0.17 0.52
VZ54
C10 C8 2.1 0.26 0.51 2.2 0.15 0.52
Note) Value at manifold base mounted, 2 position single operating
3-3-74
5 Port Solenoid Valve
Base Mounted Series VZ5000
Common SUP/Common EXH
Type 40 How to Order
1(P) port
Rc 1/4
VV5Z5 40 05 2 01
4(A), 2(B) P, R port
Stations Port size thread type
02 2 stations 01 Rc 1 8
Nil Rc
···
···
3/5(R) port F G
20 20 stations
Rc 1/4 N NPT
4(A), 2(B) port Note) For more than 10 stations, supply air to both
Rc 1/8 sides of 1(P) port and exhaust air from both
sides of 3 and 5(R) port.
T NPTF VK
Applicable solenoid
Type 41 How to Order valve VZ
G
VV5Z5 41 05 1 01 VZ54- LM
D VF
4(A), 2(B) P, R port Applicable blanking plate
Stations Port size thread type assembly
1(P) port
02 2 stations 01 Rc 1 8 Nil Rc DXT199-22-1A
VFR
Rc 1/4
···
···
F G Applicable individual EXH
4(A), 2(B) port 20 20 stations N NPT spacer assembly VP4
Rc 1/8 3/5(R) port Note) For more than 8 stations, supply air to both sides of T NPTF DXT199-29-2A
P port and exhaust air from both sides of R port. Applicable individual SUP
Rc 1/4
spacer assembly
VZS
DXT199-35-1A
Type 42 How to Order
Applicable interface VFS
VV5Z5 42 05 1 C6 regulator
ARBZ5000-00-P
P, R port
VS4
Stations A, B port size
thread type
1(P) port
02 2 stations C6 One-touch fitting for ø6
Nil Rc
VQ7
C8
···
···
Stations
SUP/EXH block 4 (A), 2 (B) D
02 2 stations port size Applicable blanking plate
mounting position
···
···
assembly
Symbol Position Applicable stations One-touch
20 20 stations C6 VZ5000-65-2A
U U side 2 to 10 stations fitting for ø6
D D side 2 to 10 stations One-touch DIN rail length specified
C8
B Both sides 2 to 20 stations fitting for ø8 Nil Standard length
Special Special Mixed M∗ 3 For 3 stations (Specify a longer
M∗ specifications ∗ In the case of mixed
specifications
···
···
fitting for ø8
02 2 stations
SUP/EXH block mounting position M∗ 20 For 20 stations standard length.)
Mixed
For 2 to 10 stations : One side ∗ In the case of mixed specifications
···
···
20 20 stations Nil (Same as direction of connector mount) (M), indicate separately on the
For 11 to 20 stations: Both sides manifold specification sheet.
B For 2 to 10 stations: Both sides
M∗ Special specifications
∗ For special specifications, indicate
separately by the manifold specification
sheet.
3-3-75
Series VZ5000
Option/Standard Manifold
Combinations of Solenoid Individual EXH Spacer Assembly Installation of the VZ500 Valve
Valve, Manifold Gasket and DXT199-29-2A on the VZ5000 Manifold
Manifold Base • Use of an adaptor plate makes it possible
Round head Round head to mount Series VZ500 on the manifold
combination screw combination screw base of Series VZ5000.
• The mounting direction is shown in the
(With springM3washer
x 31
) (M3
With spring washer )
x 47 diagram below. Mount the solenoid so that
it will be on the same side as the single
solenoid of the Series VZ5000.
• In the case of base mounting, 2(A) port of
3 port valve should be 2(B) port of manifold
base.
Blanking plate
Round head
Gasket
Interface Regulator combination
(P port regulation) screw
Gasket
Individual
SUP spacer Before Applicable base
using, refer VV5Z5-40
Gasket to page VV5Z5-41
3-3-8. VV5Z5-42
Rc 1/8 Caution
(SUP port) Mounting Screw Tightening Torques
Applicable base M3: 0.8 N·m
VV5Z5-40
VV5Z5-41
VV5Z5-42
3-3-76
5 Port Solenoid Valve
Base Mounted Series VZ5000
Option/DIN Rail Manifold
Blanking Plate Assembly Combination of Solenoid Valve, Gasket and Manifold Base
VZ5000-65-2A
Round head
Round head combination screw
Round head combination screw combination screw
( With springM3washer
x 31
) ( With springM3washer
x 31
)
( With spring washer
M3 x 8
)
Blanking plate VK
VZ
Manifold gasket
VF
Manifold gasket Manifold gasket
VFR
Applicable base
VV5Z5-45 Applicable base
VP4
Applicable base
VV5Z3-45
VV5Z5-45F
VZS
VFS
VZ5000-65-1A SUP Block Disk EXH Block Disk
Round head By installing a SUP block disk in the By installing an EXH block disk in the VS4
combination screw pressure supply passage of a manifold exhaust passage of a manifold valve, it is
valve, it is possible to supply two or more possible to divide the valve’s exhaust so that
VQ7
(With spring washer
M3 x 8
) different high and low pressures to one
manifold.
it does not affect another valve.
Blanking plate
VZ5000-68-1A VZ5000-68-1A EVS
VFN
Manifold gasket
Applicable base
VV5Z5-45F
Caution
Mounting Screw Tightening Torques
M2.5: 0.32 N·m
(For stacking type manifold)
3-3-77
Series VZ5000
Exploded View/DIN Rail Manifold
Type 45 Manifold r
U side q
(1) Loosen (both) bolts (a), which are securing the manifold onto the
DIN rail, 1 to 2 turns.
(To remove the manifold base from the DIN rail, loosen the bolts 4
Fig. (1)
to 5 turns.)
(2) Press lever (b) to disconnect the manifold block assembly at the
location in which you wish to place an additional manifold block
assembly. (However, there are no levers between q and r or (a) Bolt (Both sides)
between e and r. They can be disconnected by merely pulling
them apart.)
(b) Lever
3-3-78
5 Port Solenoid Valve
Base Mounted Series VZ5000
Exploded View/DIN Rail Manifold
Type 45F Manifold u
e i
t
VK
U side
q VZ
(b)
Lever
y VF
VFR
w
VP4
Location of addition
(a)
Bolt VZS
r (Both sides)
VFS
Replacement Parts (b) Lever
No. Description Part no. Note VS4
Manifold block C6 C6: A, B port with One-touch fitting for ø6
q VZ5000-50A-1- C8
assembly C8: A, B port with One-touch fitting for ø8 (a)
Bolt (Both sides)
VQ7
SUP/EXH block For D side, With D-sub connector and
w VZ5000-51A-1D
assembly P/R port with One-touch fitting for ø10 D side EVS
SUP/EXH block For U side, With D-sub connector and DIN rail
e VZ5000-51A-1U
assembly P/R port with One-touch fitting for ø10
r End block assembly VZ5000-52A-2D For D side, set with w
VFN
t End block assembly VZ5000-52A-1U For U side
y End block assembly VZ5000-52A-1D For D side
u End block assembly VZ5000-52A-2U For U side, set with e
SUP/EXH block Without D-sub connector, For indicated location
i VZ5000-51A-1M
assembly P/R port with One-touch fitting for ø10
To add a manifold block assembly, add it to the U side so that the terminal number of the
How to Increase Manifold Base D-sub connector and the valve link position will be in accordance with the circuit diagram.
(1) Loosen (both) bolts (a), which are securing the manifold onto the Housing cover
DIN rail, 1 to 2 turns. (To remove the manifold base from the DIN
rail, loosen the bolts 4 to 5 turns.) Hook this part on
to the DIN rail
and press down
until a click is
heard.
(2) Using a flat screwdriver, press lever (b) to disengage the link of Fig. (1)
the manifold block assembly on the U side or the D side from the
SUP/EXH block assembly or from the end block assembly. Lead
Fig. (2) Terminal wire
no.
(However, there are no levers between t and q. They can be color
(b) Lever B side coil
Black
disconnected by merely pulling them apart.) Connector 1 station A side coil
D-sub terminal no. (11 stations) White
Black connector B side coil
Black
(3) Remove the housing cover from the D-sub connector portion of White
2 station A side coil
(12 stations) White
the SUP/EXH block assembly. (Refer to Fig. (1).) B side coil
3 station Black
A side coil
(13 stations) White
(4) Following the procedure shown in Fig. (2), mount the manifold block B side coil
4 station Black
assembly to be added onto the DIN rail. As shown in Fig. (3), insert (14 stations)
A side coil
White
the pin of the lead wire assembly into the D-sub connector, and 5 station
B side coil
Black
Lead A side coil
attach the round crimped terminal to the screw that connects the wire (15 stations) White
wires. ass'y B side coil
Black
Hook 6 station A side coil
Pin (16 stations) White
B side coil
(5) Press the block assemblies and tighten the bolts (a) to fix them to After inserting the pin, U side 7 station Black
A side coil
the DIN rail. lightly pull on the lead (17 stations) White
B side coil
wire to verify the lock. 8 station Black
A side coil
Note) When there are 10 or fewer manifold block assemblies, (18 stations) White
and more are added to make a total of 11 or more, a Fig. (3) How to insert lead 9 station
B side coil
Black
A side coil
supply/exhaust block assembly must also be added. wire assembly pin Stations (19 stations) White
Housing side D side B side coil
10 station Black
A side coil
(20 stations) White
Red
Red
3-3-79
Series VZ5000
Type 40 Manifold: Bottom Ported
VV5Z5-40- Station 2-01
6-Rc 1/4
(1(P), 3/5(R) port)
PE port
(Pilot EXH)
2n-Rc 1/8
(4(A), 2(B) port)
(Pitch)
(mm)
Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 66 85 104 123 142 161 180 199 218 237 256 275 294 313 332 351 370 389 408
L2 46 65 84 103 122 141 160 179 198 217 236 255 274 293 312 331 350 369 388
MAX. 10
≅300
≅300
3-3-80
5 Port Solenoid Valve
Base Mounted Series VZ5000
Type 41 Manifold: Side Ported
VV5Z5-41- Station 1-01
Manual override PE port
(Non-locking)
(Pilot EXH)
Grommet (G), (H)
6-Rc 1/4
(1(P), 3/5(R) port)
VK
VZ
VF
≅300
≅300
MAX. 10
3-3-81
Series VZ5000
Type 42 Manifold: Side Ported
VV5Z5-42- Station 1- C6
C8
Manual override
(Non-locking)
PE port
Grommet (G), (H) (Pilot EXH)
6-Rc 1/4
(1(P), 3/5(R) port)
(Pitch)
(mm)
Stations 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
L1 77 96 115 134 153 172 191 210 229 248 267 286 305 324 343 362 381 400 419
L2 49 68 87 106 125 144 163 182 201 220 239 258 277 296 315 334 353 372 391
≅300
≅300
MAX. 10
3-3-82
5 Port Solenoid Valve
Base Mounted Series VZ5000
Type 45 DIN Rail Manifold (Non Plug-in): Side Ported
DIN rail
Manual
override G: 300 Stations 2 3 4 5 6 7 8 9 10 EVS
(Non- H: 600 L1 148 160.5 185.5 198 223 235.5 260.5 273 298
holding screw locking) (Lead wire length)
(Rail mounting hole pitch 12.5)
L2 137.5 150 175 187.5 212.5 225 250 262.5 287.5 VFN
L3 116 135 154 173 192 211 230 249 268
L4 16 13 16 12.5 15.5 12.5 15.5 12 15 (mm)
MAX. 10
≅300
≅300
(Lead wire length)
(mm)
Stations 2 3 4 5 6 7 8 9 10
L1 123 148 160.5 185.5 198 223 235.5 260.5 273
Applicable cable O.D. ø3.5 to ø7 L2 112.5 137.5 150 175 187.5 212.5 225 250 262.5
L3 97 116 135 154 173 192 211 230 249
L4 13 16 13 16 12.5 15.5 12.5 15.5 12
3-3-83
Series VZ5000
Type 45F DIN Rail Manifold (Plug-in): Side Ported
U side D side
DIN rail
DIN rail
holding screw
Manual override Terminal no. 1
(Non-locking) {JIS-X-5101
∗Applicable connector D-SUB MIL-C-24308 }
(Rail mounting hole pitch 12.5)
D side (mm)
(Station n)············(Station 1) connector Stations 2 3 4 5 6 7 8 9 10
L1 123 148 160.5 185.5 198 223 235.5 260.5 273
L2 112.5 137.5 150 175 187.5 212.5 225 250 262.5
L3 97 116 135 154 173 192 211 230 249
L4 13 16 13 16 12.5 15.5 12.5 15.5 12
C6C
Separation
VV5Z5-45FU
D- Station B- C8C (2 to 10 stations)
lever
(Push type) C6C
VV5Z5-45FB- Station - C8C (11 to 20 stations)
VV5Z5-45FU- Station - C6C
C8C (Pitch) (Pitch)
(mm) (mm)
Stations 2 3 4 5 6 7 8 9 10 Stations 2 3 4 5 6 7 8 9 10
L1 123 148 160.5 185.5 198 223 235.5 260.5 273 L1 148 160.5 185.5 198 223 235.5 260.5 273 298
L2 112.5 137.5 150 175 187.5 212.5 225 250 262.5 L2 137.5 150 175 187.5 212.5 225 250 262.5 287.5
L3 97 116 135 154 173 192 211 230 249 L3 116 135 154 173 192 211 230 249 268
L4 13 16 13 16 12.5 15.5 12.5 15.5 12 L4 16 13 16 12.5 15.5 12.5 15.5 12 15 (mm)
Stations 11 12 13 14 15 16 17 18 19 20
L1 310.5 335.5 348 373 385.5 410.5 423 448 473 485.5
L2 300 325 337.5 362.5 375 400 412.5 437.5 462.5 475
L3 287 306 325 344 363 382 401 420 439 458
L4 12 15 11.5 14.5 11.5 14.5 11 14 17 14
3-3-84
Series VZ
Made to Order Specifications:
Please contact SMC for detailed specifications, dimensions, and delivery.
3-3-85