0% found this document useful (0 votes)
687 views2 pages

Girt Design Calculation for C230x20

This document provides a summary of design calculations for a C230x20 girt section subjected to wind loading. It includes assumptions, code references, material properties, load calculations, and checks of the girt for flexure and deflection. The conclusion is that the girt section is adequate to resist the applied forces based on ratios of calculated to code limit values being less than 1.

Uploaded by

wudongxiao3953
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
687 views2 pages

Girt Design Calculation for C230x20

This document provides a summary of design calculations for a C230x20 girt section subjected to wind loading. It includes assumptions, code references, material properties, load calculations, and checks of the girt for flexure and deflection. The conclusion is that the girt section is adequate to resist the applied forces based on ratios of calculated to code limit values being less than 1.

Uploaded by

wudongxiao3953
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Project : 0

Eng : DW

Job No : 0

Chk : ZM

Doc No : 0

Calculation Sheet

Date : 2015-09-10

Subject : Building Purlin C12X20.7 - 2 Tie Rod

Rev : 0
1 of 2

GIRT DESIGN - C CHANNEL

Girt design based on

Code Abbreviation

CSA-S16-09 Limit States Design of Steel Structures

CSA-S16-09

AISC Design Guide 7: Industrial Buildings-Roofs to Anchor Rods 2nd Ed

AISC Design Guide 7

Assumptions

Code Reference

1. Girt is simply supported at building column grids


2. Girt exterior flange is laterally fully supported by wall cladding when cladding is subjected
to pressure load

AISC Design Guide 7

3. Sag rods are assumed to provide lateral restraint against buckling when cladding is subjected

page 17

to suction load
4. Girt and wall caldding self-weight are supported by sag rods hanging from roof eave strut beam
and thus no minor axis bending is considered in girt design

Input
Building importance category

Normal

Wind pressure q 1/50

q = 0.40

[kPa]

NBC10 Comment I

Reference height

h = 2.000

[m]

Fig I-7 Note (5)

For open terrain

NBC10 4.1.7.1 (5)

For importance category Normal building

NBC10 Table 4.1.7.1

Ce = 0.90
Iw = 1.00

NBC10 Comment I
Building category - internal pressure
Internal pressure coefficient
Internal gust factor

Girt size
Girt span

Category 3
- Cpi = -0.70

Page I-22 Para. 31


+ Cpi = 0.70

Cgi = 2.0

NBC10 4.1.7.1 (6)(c.)

C230x20
L = 7.620

No of sag rod in the span

ngrt = 2

Girt spacing

Sgrt = 1.981

[m]

[m]

Conclusion

[The Girt Section Is Adequate for Applied Force]

ratio = 0.65

001

Project : 0

Eng : DW

Job No : 0

Chk : ZM

Doc No : 0

Calculation Sheet

Date : 2015-09-10

Subject : Building Purlin C12X20.7 - 2 Tie Rod

Rev : 0
2 of 2

Design Check

Code Reference

External Surface Pressure


Tributary area

NBC10 Comment I
A = L x Sgrt

= 15.10

External pressure

+CpCg = 1.75 - 0.26487 log A

= 1.44

External suction

-CpCg = -2.10 + 0.35312 log A

= -1.68

[m ]

Fig I-8

Internal Surface Pressure


Internal pressure

+CpiCgi =

= 1.40

Internal suction

-CpiCgi =

= -1.40

Page I-22 Para. 31

Case 1 girt on windward side (external pressure + internal suction)


Wind pressure on cladding

p = Iw q Ce [ +CpCg - (-CpiCgi) ]

= 1.02

[kPa]

Linear load on girt

w = p x Sgrt

= 2.02

[kN/m]

= 20.6

[kNm]

Factored moment

Mfx = (1.4w) x L2 / 8

Girt exterior flange is laterally fully supported by wall cladding when cladding is subjected to pressure load
Lu =
Girt flexure

Girt deflection

= 0.0
C230x20

ratio = 0.44

[m]
OK

ULS = (5 w L4) / (384 E Ix )

= 22.4

[mm]

NBC 05

SLS = ULS / Iw (ULS) x Iw (SLS)

= 16.8

[mm]

Table 4.1.7.1

= 42.3

[mm]

a = L / 180

ratio = 0.40

OK

Case 2 girt on leeward side (external suction + internal pressure)


Wind pressure on cladding

p = Iw q Ce [ -CpCg - (+CpiCgi) ]

= -1.11

[kPa]

Linear load on girt

w = p x Sgrt

= 2.20

[kN/m]

= 22.3

[kNm]

Factored moment

Mfx = (1.4w) x L2 / 8

Sag rods are assumed to provide lateral restraint against buckling when cladding is subjected to suction load
Girt unsupported length
Girt flexure

Girt deflection

Lu = L / (ngrt +1)
C230x20

= 2.540
ratio = 0.65

[m]
OK

ULS = (5 w L4) / (384 E Ix )

= 24.4

[mm]

NBC 05

SLS = ULS / Iw (ULS) x Iw (SLS)

= 18.3

[mm]

Table 4.1.7.1

= 42.3

[mm]

a = L / 180

ratio = 0.43

OK