Project : 0
Eng : DW
Job No : 0
Chk : ZM
Doc No : 0
Calculation Sheet
Date : 2015-09-10
Subject : Building Purlin C12X20.7 - 2 Tie Rod
Rev : 0
1 of 2
GIRT DESIGN - C CHANNEL
Girt design based on
Code Abbreviation
CSA-S16-09 Limit States Design of Steel Structures
CSA-S16-09
AISC Design Guide 7: Industrial Buildings-Roofs to Anchor Rods 2nd Ed
AISC Design Guide 7
Assumptions
Code Reference
1. Girt is simply supported at building column grids
2. Girt exterior flange is laterally fully supported by wall cladding when cladding is subjected
to pressure load
AISC Design Guide 7
3. Sag rods are assumed to provide lateral restraint against buckling when cladding is subjected
page 17
to suction load
4. Girt and wall caldding self-weight are supported by sag rods hanging from roof eave strut beam
and thus no minor axis bending is considered in girt design
Input
Building importance category
Normal
Wind pressure q 1/50
q = 0.40
[kPa]
NBC10 Comment I
Reference height
h = 2.000
[m]
Fig I-7 Note (5)
For open terrain
NBC10 4.1.7.1 (5)
For importance category Normal building
NBC10 Table 4.1.7.1
Ce = 0.90
Iw = 1.00
NBC10 Comment I
Building category - internal pressure
Internal pressure coefficient
Internal gust factor
Girt size
Girt span
Category 3
- Cpi = -0.70
Page I-22 Para. 31
+ Cpi = 0.70
Cgi = 2.0
NBC10 4.1.7.1 (6)(c.)
C230x20
L = 7.620
No of sag rod in the span
ngrt = 2
Girt spacing
Sgrt = 1.981
[m]
[m]
Conclusion
[The Girt Section Is Adequate for Applied Force]
ratio = 0.65
001
Project : 0
Eng : DW
Job No : 0
Chk : ZM
Doc No : 0
Calculation Sheet
Date : 2015-09-10
Subject : Building Purlin C12X20.7 - 2 Tie Rod
Rev : 0
2 of 2
Design Check
Code Reference
External Surface Pressure
Tributary area
NBC10 Comment I
A = L x Sgrt
= 15.10
External pressure
+CpCg = 1.75 - 0.26487 log A
= 1.44
External suction
-CpCg = -2.10 + 0.35312 log A
= -1.68
[m ]
Fig I-8
Internal Surface Pressure
Internal pressure
+CpiCgi =
= 1.40
Internal suction
-CpiCgi =
= -1.40
Page I-22 Para. 31
Case 1 girt on windward side (external pressure + internal suction)
Wind pressure on cladding
p = Iw q Ce [ +CpCg - (-CpiCgi) ]
= 1.02
[kPa]
Linear load on girt
w = p x Sgrt
= 2.02
[kN/m]
= 20.6
[kNm]
Factored moment
Mfx = (1.4w) x L2 / 8
Girt exterior flange is laterally fully supported by wall cladding when cladding is subjected to pressure load
Lu =
Girt flexure
Girt deflection
= 0.0
C230x20
ratio = 0.44
[m]
OK
ULS = (5 w L4) / (384 E Ix )
= 22.4
[mm]
NBC 05
SLS = ULS / Iw (ULS) x Iw (SLS)
= 16.8
[mm]
Table 4.1.7.1
= 42.3
[mm]
a = L / 180
ratio = 0.40
OK
Case 2 girt on leeward side (external suction + internal pressure)
Wind pressure on cladding
p = Iw q Ce [ -CpCg - (+CpiCgi) ]
= -1.11
[kPa]
Linear load on girt
w = p x Sgrt
= 2.20
[kN/m]
= 22.3
[kNm]
Factored moment
Mfx = (1.4w) x L2 / 8
Sag rods are assumed to provide lateral restraint against buckling when cladding is subjected to suction load
Girt unsupported length
Girt flexure
Girt deflection
Lu = L / (ngrt +1)
C230x20
= 2.540
ratio = 0.65
[m]
OK
ULS = (5 w L4) / (384 E Ix )
= 24.4
[mm]
NBC 05
SLS = ULS / Iw (ULS) x Iw (SLS)
= 18.3
[mm]
Table 4.1.7.1
= 42.3
[mm]
a = L / 180
ratio = 0.43
OK
002